Description

Fire Magic 3092D One-Hour Automatic Gas Shut-Off Timer

The 3092D is an inline mechanical timer that stops gas flow when the selected cooking period ends. Its rotary dial provides up to one hour of operation. It is a secondary control installed downstream of a separate primary gas shut-off valve; it does not replace that required valve.

Key features and exact model

  • Exact model and MPN: 3092D
  • One-hour timer with dial markings at 20, 40 and 60 minutes
  • 1/2-inch NPT connections at both ends
  • Horizontal or vertical installation permitted
  • Gas-supply inlet identified by the IN marking
  • Manufacturer price-file product weight: 0.65 pound

Gas capacity and operating limits

  • Natural gas: 100,000 BTU capacity at 0.6 specific gravity and 7 inches water column
  • Propane: 100,000 BTU capacity at 1.53 specific gravity and 11 inches water column
  • Maximum working pressure: 1/2 PSIG
  • Ambient operating range: 0 to 175 degrees Fahrenheit

These are the timer's documented gas-flow conditions, not a promise of compatibility with every grill. Have the installer check the appliance demand, supply conditions and its current installation manual before selecting this control.

Included, required and optional items

This product is the 3092D timer shut-off valve. The gas appliance and separate primary shut-off valve are not part of the timer. The installation must retain an accessible primary gas shut-off upstream of the timer. Select any piping, adapters and appliance connection components to suit the verified installation rather than assuming a universal connection package.

Placement and installation

Install the timer in the supply line between the primary shut-off valve and the appliance, with the supply connected to the side marked IN. Locate it at least 18 inches from the appliance and no more than six feet away. If installed inside an appliance enclosure, it must remain easily accessible. Protect it from excessive heat and outdoor elements. The primary shut-off must also be within six feet of the appliance and upstream of the timer.

Use gas-resistant pipe joint compound on NPT connections, not on flare fittings, and leak-test all connections. Installation must follow the appliance instructions, manual C2-740 and applicable local codes, or the applicable National Fuel Gas Code ANSI Z223.1/NFPA 54 or CSA B149.1 when local codes do not apply.

Operation and ongoing checks

Turn the dial clockwise to the desired time. For a period shorter than 20 minutes, first turn past 20 minutes to activate the mechanism, then turn back to the desired setting. Positions between the marked increments are estimates. The dial returns counterclockwise and shuts off flow at OFF.

After every use, turn the appliance controls off, slowly turn an operating timer to OFF, and close the primary supply shut-off valve to completely shut off gas to the appliance. Test the timer at least monthly or more often when conditions warrant. Verify that no gas flows when it reaches OFF. If it does not shut off, have a gas professional replace it.

Documentation and warranty

The linked exact-model manual covers installation and use. It does not establish a warranty duration for this valve; confirm applicable manufacturer warranty terms before purchase if coverage duration is material. Overall dimensions and packaged shipping dimensions are not verified in the cited source and are not estimated here.

Manufacturer documents

Manufacturer installation and use instructions | Official product information

Specifications

SKU: 3092D
UPC: 619655083476

Fire Magic

Fire Magic 3092D One-Hour Automatic Gas Shut-Off Timer

Write a Review
Expert Help Available (844) 545-7995
SKU: 3092D
UPC: 619655083476
$120.00
BUY WITH CONFIDENCE Fireplace expertise from selection to delivery.
Shipping & Delivery Most in-stock items are released for shipment within 1–2 business days after payment and order review. Carrier transit is additional.
Free Shipping Eligible orders: free standard shipping to the contiguous U.S. Exclusions apply.
Best Price Guarantee Eligible identical products from authorized U.S. retailers; compare total delivered price before tax. Request before purchase or within 7 calendar days after purchase.
Contractor Pricing Trade professionals can contact us for project and volume pricing.
30-Day Returns Request a return within 30 days for eligible new, unused, uninstalled items. Authorization and exclusions apply.
Fireplace Experts Need help choosing? Talk to an expert before you order.
CONFIGURE YOUR FIREPLACE

Build Your Fireplace

Complete the required selections first, then add only the compatible options your fireplace and installation need.

1 Required selections
2 Customize options
3 Review & order
Expert Help (844) 545-7995
1

Fireplace

Complete the required product selections for this fireplace.

Required
Hurry up! Current stock:
Available to order
READY TO ORDER

Your Fireplace Configuration

Review your selections, then add your configured fireplace to cart.

Configuration Calculator
Fireplace
Selected Components $0.00
Selected Accessories $0.00
Configured Total
Need help before ordering? Talk to a Product Expert (844) 545-7995
  • product-security-image-1.jpg
  • product-security-image-2.jpg
  • product-security-image-3.jpg
  • product-security-image-4.jpg
30-Day Returns Eligible items; authorization and exclusions apply

Request a return within 30 calendar days after delivery for eligible new, unused, unassembled and uninstalled items in original packaging. Written authorization is required. Read the Returns Policy for conditions, fees and exclusions.

Return Window 30 Days
Return Support Email Our Team
Shipping & Delivery Clear delivery expectations and tracking

Most in-stock items are released for shipment within 1–2 business days after payment and order review. Carrier transit is additional. Parcel transit commonly takes 3–7 business days; freight commonly takes 5–10 business days after shipment. Special-order and backordered items may take longer. Shipping details, exclusions and damage reporting.

Most In-Stock Items: Processing 1–2 Business Days After Review
Standard Shipping Eligible Contiguous U.S. Orders

Fire Magic 3092D One-Hour Automatic Gas Shut-Off Timer

The 3092D is an inline mechanical timer that stops gas flow when the selected cooking period ends. Its rotary dial provides up to one hour of operation. It is a secondary control installed downstream of a separate primary gas shut-off valve; it does not replace that required valve.

Key features and exact model

  • Exact model and MPN: 3092D
  • One-hour timer with dial markings at 20, 40 and 60 minutes
  • 1/2-inch NPT connections at both ends
  • Horizontal or vertical installation permitted
  • Gas-supply inlet identified by the IN marking
  • Manufacturer price-file product weight: 0.65 pound

Gas capacity and operating limits

  • Natural gas: 100,000 BTU capacity at 0.6 specific gravity and 7 inches water column
  • Propane: 100,000 BTU capacity at 1.53 specific gravity and 11 inches water column
  • Maximum working pressure: 1/2 PSIG
  • Ambient operating range: 0 to 175 degrees Fahrenheit

These are the timer's documented gas-flow conditions, not a promise of compatibility with every grill. Have the installer check the appliance demand, supply conditions and its current installation manual before selecting this control.

Included, required and optional items

This product is the 3092D timer shut-off valve. The gas appliance and separate primary shut-off valve are not part of the timer. The installation must retain an accessible primary gas shut-off upstream of the timer. Select any piping, adapters and appliance connection components to suit the verified installation rather than assuming a universal connection package.

Placement and installation

Install the timer in the supply line between the primary shut-off valve and the appliance, with the supply connected to the side marked IN. Locate it at least 18 inches from the appliance and no more than six feet away. If installed inside an appliance enclosure, it must remain easily accessible. Protect it from excessive heat and outdoor elements. The primary shut-off must also be within six feet of the appliance and upstream of the timer.

Use gas-resistant pipe joint compound on NPT connections, not on flare fittings, and leak-test all connections. Installation must follow the appliance instructions, manual C2-740 and applicable local codes, or the applicable National Fuel Gas Code ANSI Z223.1/NFPA 54 or CSA B149.1 when local codes do not apply.

Operation and ongoing checks

Turn the dial clockwise to the desired time. For a period shorter than 20 minutes, first turn past 20 minutes to activate the mechanism, then turn back to the desired setting. Positions between the marked increments are estimates. The dial returns counterclockwise and shuts off flow at OFF.

After every use, turn the appliance controls off, slowly turn an operating timer to OFF, and close the primary supply shut-off valve to completely shut off gas to the appliance. Test the timer at least monthly or more often when conditions warrant. Verify that no gas flows when it reaches OFF. If it does not shut off, have a gas professional replace it.

Documentation and warranty

The linked exact-model manual covers installation and use. It does not establish a warranty duration for this valve; confirm applicable manufacturer warranty terms before purchase if coverage duration is material. Overall dimensions and packaged shipping dimensions are not verified in the cited source and are not estimated here.

Manufacturer documents

Manufacturer installation and use instructions | Official product information