  • Maximum input: Natural gas 24,000; propane 24,000 BTU/h. Minimum input, millivolt only: natural gas 18,000; propane 19,000 BTU/h.

Features

  • Viewing area: 30-1/2 inches wide × 24-7/8 inches high
  • Venting: 4 x 6 5/8 Top Vent Only (Refer to manual for venting requirements)
  • Framing: 47-1/4 inches high × 38 inches wide × 17-5/8 inches deep; follow the manual before construction.

Includes

  • Barrier

Requires

  • Log Set

 

Verified model and configuration

The Empire DVCP36BP is a traditional clean-face direct-vent gas fireplace. Select the exact natural-gas or propane model and millivolt or intermittent-pilot ignition configuration. The installation manual covers DVCP36BP30K and DVCP36BP70K revisions; verify the complete rating-plate model for service and conversion parts. Fuel conversion requires the certified kit for that exact model and control system.

Technical dimensions and fuel ratings

Maximum input, natural gas / propane24,000 / 24,000 BTU/h
Minimum input, millivolt only, natural gas / propane18,000 / 19,000 BTU/h
Face width × height37-7/16 × 38-1/4 inches, excluding nailing flanges and standoffs
Appliance depth17-1/2 inches
Viewing width × height30-1/2 × 24-7/8 inches
Framing width × height × depth38 × 47-1/4 × 17-5/8 inches
Gas connection1/2-inch NPT
Top direct vent4-inch exhaust / 6-5/8-inch intake

Included and required

The appliance includes a protective glass barrier, which must be installed. The manufacturer requires the correct ceramic-fiber log assembly to complete the fireplace interior; do not operate without it. Install the logs and any approved additional decorative media according to the accessory instructions. A rock selection is not a substitute for the required log assembly.

A complete approved direct-vent system and the correctly configured gas supply are required. Venting brings combustion air from outdoors and expels exhaust outdoors; this is not a vent-free appliance and must not burn solid fuel.

Optional finishes and equipment

The manual lists DVP36FAB aged-brick, DVP36FCB cottage-brick and DVP36FRB rustic-brick ceramic-fiber liners, plus DVP36NKR black-reflective liner. FBB10 automatic variable-speed blower and LK6 120-volt lighting are optional. Remotes and thermostats must match the chosen ignition system; RVKN-1 and RVKP-1 are listed for natural-gas and propane intermittent-pilot configurations respectively.

Venting and installation planning

Choose the vent route and termination before framing. The manual lists DVVK-4TSP for 4-1/2 to 6-inch walls, DVVK-4TP for 8 to 12-inch walls, DVVK-4VP for vertical venting and DVVK-4F horizontal flex. Flex kits require the specified SD46DVA-FCFX7 adapter. These are installation alternatives, not a requirement to purchase every kit.

Horizontal vent requires at least 3 inches of clearance above and 2 inches at the sides and bottom. Follow the full vent-length and elbow tables for the selected route. Allow at least 24 inches from the framing edge to the chase top. Finish the black appliance face only with the specified noncombustible materials, and do not obstruct air openings. Framing dimensions do not replace the manual’s mantel, wall-finishing and combustible-clearance diagrams.

Manufacturer documentation

Exact DVCP36 installation manual: pages 8–10 cover ratings, accessories and dimensions; pages 22–23 cover framing, log installation and vent clearance. Retain the homeowner instructions supplied for the chosen ignition system. A qualified installer must follow all manufacturer instructions and applicable codes.

Specifications

SKU: DVCP36BP
Condition: New

Empire Hearth

Empire Hearth 36" Tahoe Premium Clean Face Direct Vent Traditional Fireplace DVCP36BP

Write a Review
Expert Help Available (844) 545-7995
SKU: DVCP36BP
Condition: New
$2,319.00 - $2,589.00
BUY WITH CONFIDENCE Product expertise from selection to delivery.
CONFIGURE YOUR FIREPLACE

Build Your Fireplace

Complete the required selections first, then add only the compatible options your fireplace and installation need.

1 Required selections
2 Customize options
3 Review & order
Expert Help (844) 545-7995

Fireplace

Complete the required product selections for this fireplace.

Required
  • Empire Hearth 32"/36" Ceramic Fiber 6 piece Log Set LS3236FF
  • Empire Hearth 36" Aged Brick Liner DVP36FAB
  • Empire Hearth 36" Rustic Brick Liner DVP36FRB
  • Empire Hearth 36" Black Porcelain Liner (Replaces DVP36LKR) DVP36NKR
  • Empire Hearth On/Off Remote with Battery Receiver (Millivolt Only) FRBC
  • Empire Hearth Thermostatic Remote Control with Battery Back-up Receiver (Millivolt Only) FRBTC2
  • Empire Hearth On/Off Remote control with Electric battery back-up Receiver (Millivolt Only) FREC
  • Empire Hearth Programmable Touchscreen Remote Control with Battery Receiver (Millivolt Only) FRBTPS
  • Empire Hearth On/Off Wall Switch (Used with Millivolt Only) FWS1
  • Empire Hearth Reed Switch Wall Thermostat (Millivolt Only) TMV
  • Empire Hearth Wireless Wall Thermostat (Millivolt Only) TRW
  • Empire Hearth Variable Flame Remote Control Kit for Natural Gas RVKN
  • Empire Hearth Variable Flame Remote Control Kit for Propane RVKP
  • Empire Hearth Variable Speed Thermostatic Blower FBB10
  • Empire Hearth 24" Stainless Steel Flex Gas Line GF24
  • Empire Hearth Platinum Embers PE20
  • Empire Hearth Ember Kit EK1
  • Empire Hearth 120 V Lighting Kit LK6
  • Empire Hearth Natural Gas to Propane Millivolt Conversion Kit - MV 31770
  • Empire Hearth Propane to Natural Gas Millivolt Conversion Kit - MV 31771
  • Empire Hearth Propane to Natural Gas Intermittent Pilot Conversion Kit - IP 32877
  • Empire Hearth Natural Gas to Propane Intermittent Pilot Conversion Kit - IP 32876
  • Duravent 4"- 6 5/8" Double Wall 6" Galvalume Vent Pipe 46DVA-06
  • Duravent 4"- 6 5/8" Double Wall 9" Galvalume Vent Pipe 46DVA-09
  • Duravent 4" - 6-5/8" Double Wall Galvanized 12" Vent Pipe 45DVA-12
  • Duravent 4"- 6 5/8" Double Wall 18" Galvalume Vent Pipe 46DVA-18
  • Duravent 4"- 6 5/8" Double Wall 24" Galvalume Vent Pipe 46DVA-24
  • Duravent 4"- 6 5/8" Double Wall 36" Galvalume Vent Pipe 46DVA-36
  • Duravent 4"- 6 5/8" Double Wall 48" Galvalume Vent Pipe 46DVA-48
  • Duravent 4"- 6 5/8" Double Wall 60" Galvalume Vent Pipe 46DVA-60
  • Duravent 4"- 6 5/8" Double Wall 8 1/2" Pipe Extension Galvalume Vent Pipe (3" - 7") 46DVA-08A
  • Duravent 4"- 6 5/8" Double Wall 11" - 14-5/8" Pipe Extension Galvalume Vent Pipe (9-1/2" - 15-1/2") 46DVA-17TA
  • Duravent 4"- 6 5/8" Double Wall 17" - 24" Pipe Extension Galvalume Vent Pipe (15-1/2" - 22-1/2") 46DVA-24TA
  • Duravent 4"- 6 5/8" Double Wall 36" Concentric Flex Galvalume Vent 46DVA-36FF
  • Duravent 4"- 6 5/8" Double Wall 60" Concentric Flex Galvalume Vent 46DVA-60FF
  • Duravent 4"- 6 5/8" Double Wall 120" Concentric Flex Galvalume Vent 46DVA-120FF
  • Duravent 4"- 6 5/8" Double Wall 30 Degree Galvalume Elbow 46DVA-E30
  • Duravent 4"- 6 5/8" Double Wall 45 Degree Galvalume Elbow 46DVA-E45
  • Duravent 4"- 6 5/8" Double Wall 60 Degree Galvalume Elbow 46DVA-E60
  • Duravent 4"- 6 5/8" Double Wall 90 Degree Galvalume Elbow 46DVA-E90
  • Duravent 4" - 6-5/8" Wall/Ceiling Thimble Cover 46DVA-DC-GAS
  • Duravent 4" - 6-5/8" Wall Thimble 46DVA-WT
  • Duravent 4" - 6-5/8" Wall Thimble – Reduced (use w/ round horizontal & sconce cap only) 46DVA-WTS
  • Duravent 4" - 6-5/8" Wall Thimble – Universal 46DVA-WTU
  • Duravent 4" - 6-5/8" Wall Firestop 46DVA-WFS
  • Duravent 4" - 6-5/8" Wall Strap 46DVA-WS
  • Duravent 4" - 6-5/8" Roof Support 46DVA-RS
  • Duravent 4" - 6-5/8" Cathedral Ceiling Support Box 46DVA-CS
  • Duravent 4" - 6-5/8" Ceiling Firestop 46DVA-FS
  • Duravent 4" - 6-5/8" Attic Insulation Shield 46DVA-IS
  • Duravent 4" - 6-5/8" Vinyl Siding Standoff (Sized for 46DVA-HC) 46DVA-VSS
  • Duravent 4" - 6-5/8" Vinyl Siding Standoff Kit (4-pc. sized for 46DVA-HC) 46DVA-VSK
  • Duravent 4" - 6-5/8" Vinyl Siding Standoff Kit V46DVA-VSKS
  • Duravent 4" - 6-5/8" Storm Collar 46DVA-SC
  • Duravent 4" - 6-5/8" Flashing - 0/12-6/12 Pitch 46DVA-F6
  • Duravent 4" - 6-5/8" Flashing - 7/12-12/12 Pitch 46DVA-F12
  • Duravent 4" - 6-5/8" Flashing - Flat 46DVA-FF
  • Duravent 4" - 6-5/8" Dead Soft Flashing - 7/12-12/12 Pitch for Metal Roofs 46DVA-F12DS
  • Duravent 4" - 6-5/8" Dead Soft Flashing - 0/12-6/12 Pitch for Metal Roofs 46DVA-F6DS
  • DuraVent Rubber Boot Flashing Kit - Max 12/12 Pitch, for Metal Roofs 200275
  • Duravent DuraTech 6" Diameter Snow Splitter 6"-10" 6DT-SP
  • Duravent 4" - 6-5/8" Square High Wind (Alum) 46DVA-HC
  • Duravent 4" - 6-5/8" Sconce High Wind (Alum) 46DVA-HSCH
  • Duravent 4" - 6-5/8" Snorkel Termination Cap 14” 46DVA-SNK14
  • Duravent 4" - 6-5/8" Snorkel Termination Cap 36” 46DVA-SNK36
  • Duravent 4" - 6-5/8" Round Cap w/ Square Base 46DVA-HRCS
  • Duravent 4" - 6-5/8" Horizontal Windguard 46DVA-WG
  • Duravent 4" - 6-5/8" High Wind Termination Cap 46DVA-VCH
  • Duravent 4" - 6-5/8" Low Profile Termination Cap 46DVA-VC
  • Duravent 4" - 6-5/8" Vertical Windguard 46DVA-VWG
Hurry up! Current stock:
Available to order
READY TO ORDER

Your Fireplace Configuration

Review your selections, then add your configured fireplace to cart.

Configuration Calculator
Fireplace —
Selected Components $0.00
Selected Accessories $0.00
Configured Total —
Need help before ordering? Talk to a Product Expert (844) 545-7995
  • product-security-image-1.jpg
  • product-security-image-2.jpg
  • product-security-image-3.jpg
  • product-security-image-4.jpg
30-Day Returns Eligible items; authorization and exclusions apply

Request a return within 30 calendar days after delivery for eligible new, unused, unassembled and uninstalled items in original packaging. Written authorization is required. Read the Returns Policy for conditions, fees and exclusions.

Return Window 30 Days
Return Support Email Our Team
Shipping & Delivery Clear delivery expectations and tracking

Most in-stock items are released for shipment within 1–2 business days after payment and order review. Carrier transit is additional. Parcel transit commonly takes 3–7 business days; freight commonly takes 5–10 business days after shipment. Special-order and backordered items may take longer. Shipping details, exclusions and damage reporting.

Most In-Stock Items: Processing 1–2 Business Days After Review
Standard Shipping Eligible Contiguous U.S. Orders

Overview

Empire Hearth 36" Tahoe Premium Clean Face Direct Vent Traditional Fireplace DVCP36BP

Ceramic Fiber Liner options for Clean-Face Premium models include a traditional Aged Brick with smoky highlights, and an old-world Cottage Brick. Or choose the deep black polished porcelain-steel liner that reflects the flames for a luxurious effect.

The available lighting kit draws attention to the intricate details in the log set and brick liner – even when no fire is burning. You can enhance heat distribution with the optional variable-speed blower. Both the light and blower include dimmer controls.

Clean-Face Premium models are available in Millivolt and in Green Earth Preferred Intermittent Pilot.

  • Maximum input: Natural gas 24,000; propane 24,000 BTU/h. Minimum input, millivolt only: natural gas 18,000; propane 19,000 BTU/h.

Features

  • Viewing area: 30-1/2 inches wide × 24-7/8 inches high
  • Venting: 4 x 6 5/8 Top Vent Only (Refer to manual for venting requirements)
  • Framing: 47-1/4 inches high × 38 inches wide × 17-5/8 inches deep; follow the manual before construction.

Includes

  • Barrier

Requires

  • Log Set

 

Verified model and configuration

The Empire DVCP36BP is a traditional clean-face direct-vent gas fireplace. Select the exact natural-gas or propane model and millivolt or intermittent-pilot ignition configuration. The installation manual covers DVCP36BP30K and DVCP36BP70K revisions; verify the complete rating-plate model for service and conversion parts. Fuel conversion requires the certified kit for that exact model and control system.

Technical dimensions and fuel ratings

Maximum input, natural gas / propane24,000 / 24,000 BTU/h
Minimum input, millivolt only, natural gas / propane18,000 / 19,000 BTU/h
Face width × height37-7/16 × 38-1/4 inches, excluding nailing flanges and standoffs
Appliance depth17-1/2 inches
Viewing width × height30-1/2 × 24-7/8 inches
Framing width × height × depth38 × 47-1/4 × 17-5/8 inches
Gas connection1/2-inch NPT
Top direct vent4-inch exhaust / 6-5/8-inch intake

Included and required

The appliance includes a protective glass barrier, which must be installed. The manufacturer requires the correct ceramic-fiber log assembly to complete the fireplace interior; do not operate without it. Install the logs and any approved additional decorative media according to the accessory instructions. A rock selection is not a substitute for the required log assembly.

A complete approved direct-vent system and the correctly configured gas supply are required. Venting brings combustion air from outdoors and expels exhaust outdoors; this is not a vent-free appliance and must not burn solid fuel.

Optional finishes and equipment

The manual lists DVP36FAB aged-brick, DVP36FCB cottage-brick and DVP36FRB rustic-brick ceramic-fiber liners, plus DVP36NKR black-reflective liner. FBB10 automatic variable-speed blower and LK6 120-volt lighting are optional. Remotes and thermostats must match the chosen ignition system; RVKN-1 and RVKP-1 are listed for natural-gas and propane intermittent-pilot configurations respectively.

Venting and installation planning

Choose the vent route and termination before framing. The manual lists DVVK-4TSP for 4-1/2 to 6-inch walls, DVVK-4TP for 8 to 12-inch walls, DVVK-4VP for vertical venting and DVVK-4F horizontal flex. Flex kits require the specified SD46DVA-FCFX7 adapter. These are installation alternatives, not a requirement to purchase every kit.

Horizontal vent requires at least 3 inches of clearance above and 2 inches at the sides and bottom. Follow the full vent-length and elbow tables for the selected route. Allow at least 24 inches from the framing edge to the chase top. Finish the black appliance face only with the specified noncombustible materials, and do not obstruct air openings. Framing dimensions do not replace the manual’s mantel, wall-finishing and combustible-clearance diagrams.

Manufacturer documentation

Exact DVCP36 installation manual: pages 8–10 cover ratings, accessories and dimensions; pages 22–23 cover framing, log installation and vent clearance. Retain the homeowner instructions supplied for the chosen ignition system. A qualified installer must follow all manufacturer instructions and applicable codes.

Customers Also Viewed