Description

Empire 38500 propane-to-natural gas conversion kit

Manufacturer part 38500 is the specified fuel-conversion kit for the DVCT35CBN95 intermittent-pilot gas appliance. It changes the listed appliance from propane to natural gas; it does not change the fireplace size, ignition system or installation type.

Exact application

Manufacturer part number38500
Appliance model familyDVCT35CBN95
Control systemIntermittent pilot
Starting fuelpropane
Converted fuelnatural gas

Before ordering

Compare the complete appliance rating-plate model, revision, current fuel and ignition system with the manufacturer conversion table. This is not a universal Empire conversion kit. Similar model numbers, opposite conversion directions and different control systems do not establish compatibility. No fuel-conversion kit is needed when the appliance is already configured for the available gas supply.

Installation

A qualified service agency must perform the conversion with the certified kit and its instructions, then verify supply and manifold pressures, correct burner setup and safe operation. Do not substitute or improvise components. The conversion kit does not replace the appliance’s required logs, liner, barrier, vent system or other installation components.

Manufacturer documentation

DVCT35CBN95 manufacturer installation manual, conversion-kit table on page 7, explicitly identifies part 38500 and the fuel direction. Follow the kit instructions, appliance manual and applicable codes. Retain the documentation with the appliance.

Specifications

SKU: 38500
Condition: New

Empire Hearth

Empire Hearth Propane to Natural Gas Conversion Kit - MF 38500

Write a Review
Expert Help Available (844) 545-7995
SKU: 38500
Condition: New
$109.00
BUY WITH CONFIDENCE Product expertise from selection to delivery.
CONFIGURE YOUR FIREPLACE

Build Your Fireplace

Complete the required selections first, then add only the compatible options your fireplace and installation need.

1 Required selections
2 Customize options
3 Review & order
Expert Help (844) 545-7995

Fireplace

Complete the required product selections for this fireplace.

Required
Hurry up! Current stock:
Available to order
READY TO ORDER

Your Fireplace Configuration

Review your selections, then add your configured fireplace to cart.

Configuration Calculator
Fireplace —
Selected Components $0.00
Selected Accessories $0.00
Configured Total —
Need help before ordering? Talk to a Product Expert (844) 545-7995
  • product-security-image-1.jpg
  • product-security-image-2.jpg
  • product-security-image-3.jpg
  • product-security-image-4.jpg
30-Day Returns Eligible items; authorization and exclusions apply

Request a return within 30 calendar days after delivery for eligible new, unused, unassembled and uninstalled items in original packaging. Written authorization is required. Read the Returns Policy for conditions, fees and exclusions.

Return Window 30 Days
Return Support Email Our Team
Shipping & Delivery Clear delivery expectations and tracking

Most in-stock items are released for shipment within 1–2 business days after payment and order review. Carrier transit is additional. Parcel transit commonly takes 3–7 business days; freight commonly takes 5–10 business days after shipment. Special-order and backordered items may take longer. Shipping details, exclusions and damage reporting.

Most In-Stock Items: Processing 1–2 Business Days After Review
Standard Shipping Eligible Contiguous U.S. Orders

Empire 38500 propane-to-natural gas conversion kit

Manufacturer part 38500 is the specified fuel-conversion kit for the DVCT35CBN95 intermittent-pilot gas appliance. It changes the listed appliance from propane to natural gas; it does not change the fireplace size, ignition system or installation type.

Exact application

Manufacturer part number38500
Appliance model familyDVCT35CBN95
Control systemIntermittent pilot
Starting fuelpropane
Converted fuelnatural gas

Before ordering

Compare the complete appliance rating-plate model, revision, current fuel and ignition system with the manufacturer conversion table. This is not a universal Empire conversion kit. Similar model numbers, opposite conversion directions and different control systems do not establish compatibility. No fuel-conversion kit is needed when the appliance is already configured for the available gas supply.

Installation

A qualified service agency must perform the conversion with the certified kit and its instructions, then verify supply and manifold pressures, correct burner setup and safe operation. Do not substitute or improvise components. The conversion kit does not replace the appliance’s required logs, liner, barrier, vent system or other installation components.

Manufacturer documentation

DVCT35CBN95 manufacturer installation manual, conversion-kit table on page 7, explicitly identifies part 38500 and the fuel direction. Follow the kit instructions, appliance manual and applicable codes. Retain the documentation with the appliance.

Customers Also Viewed