Product overview

The DVP-HVS is the horizontal pipe support for the HHT DVP 5" x 8" direct-vent system. HHT lists it as "support du conduit" in its Approved Vent Components guide and as a "Horizontal vent support" on its venting components sheet. It is a vent component, not a fireplace.

Specifications

Manufacturer part number DVP-HVS
Component Horizontal vent support
Vent system HHT DVP, 5" inner x 8" outer
Horizontal support spacing Every 5 ft (4033-215 p.6)

Installation and safety notes

Support horizontal runs every 5 ft and vertical runs every 8 ft after the 25 ft maximum unsupported rise (4033-215 p.6). HHT also allows a plumber's strap for vertical support.

Horizontal runs must rise toward the termination as specified in your appliance manual. Clearances to combustibles are set by the appliance installation manual; keep insulation and combustibles out of the air space around the vent (4033-215 p.1).

Exact-model manuals and downloads

HHT Approved Vent Components (Composants de l'évacuation approuvés, French edition), 2583-983BFR, 11/23: page 2, Fig. 1 lists DVP-HVS.

HHT DVP Venting System Installation Instructions, 4033-215 Rev H, 9/24: page 6 gives support spacing.

HHT Gas Venting Components sheet, HHT-1028U-0209: lists DVP-HVS "Horizontal vent support".

Frequently asked questions — DVP-HVS

How often must horizontal DVP pipe be supported?

Every 5 ft per HHT 4033-215.

What about vertical runs?

Vertical pipe is supported every 8 ft after the 25 ft maximum unsupported rise, using a vent support or plumber's strap.

Is the DVP-HVS for SLP pipe?

It is listed in the DVP (5" x 8") component diagrams.

Compatibility

Majestic lists this part by part number in the installation manuals of these appliances sold on our store:

If your appliance is not listed, check its installation manual or contact us before ordering.