Majestic Mercury 32" Direct Vent Gas Fireplace MERC32IN
SKU / Model: MERC32IN
Fireplace only$2,209.00
Black Friday Savings applied in your cart
Unlock an exclusive offer on this product.
Product overview
The Majestic Mercury 32" (MERC32IN) is a compact, traditional direct vent gas fireplace with a six-piece log set, glowing embers and lava rock behind tempered glass. Its small footprint and flexible venting make it an easy fit for bedrooms, dens, basements and other rooms where a full-size fireplace will not fit.
It ships with its decorative front and angled hood (SRV2401-021), so the look is complete out of the box; 550-TRIM3-BK-B and 550-TRIM4-BK-B trims add a finished border.
Input is 13,500-19,100 BTU/h on natural gas (14,500-19,100 BTU/h on propane with the LPK-3732 kit), sized for zone heating of a single room. The optional GFK-160A fan helps move the heat, and a Heat-Zone kit can send warm air to another room.
IntelliFire intermittent pilot ignition runs on a 3 VAC transformer or two D-cell batteries, so it works in a power outage. Add the RCT-MLT-HHT remote, SMART-STAT-HHT thermostat remote or WSK-21-W wall switch.
Venting is very flexible: top or rear with DVP or SLP rigid pipe, SLP-FLEX flex, or a LINK-DV30B co-linear kit in an existing masonry chimney, with top-vent runs up to 60 ft vertical. It is the smallest traditional Majestic direct vent fireplace in the line.
Key features
- Direct vent: Sealed combustion using outside air.
- IntelliFire IPI ignition: 3 V control valve; transformer or two D-cell batteries (pp.45-46).
- Log set: Six-piece LOGS-MERC32 with embers and lava rock (pp.51-55).
- Decorative front included: Front and angled hood SRV2401-021; integral barrier (p.55).
- Tempered glass: ANSI Z97.1 / CPSC 16 CFR 1202.
- Flexible venting: DVP, SLP, SLP-FLEX, SLP-FLEX7 (Canada) or LINK-DV30B with DV-46DVA-GCL; top or rear (pp.13-30).
- Optional fan: GFK-160A (2026 book).
- Optional controls: RCT-MLT-HHT remote, SMART-STAT-HHT thermostat remote, WSK-21-W wall switch (2026 book).
- Trim kits: 550-TRIM3-BK-B and 550-TRIM4-BK-B (2026 book).
- Heat-Zone: Optional Heat-Zone gas kit (manual sect. 6.B).
- Propane conversion: LPK-3732 kit (owner's manual parts list).
- Manufactured homes: OEM installation allowed (HUD 24 CFR 3280).
- Certification: UL listed direct vent heater, CSA/ANSI Z21.88-2019 / CSA 2.33-2019 (p.4).
Specifications
| Model | MERC32IN (natural gas) |
|---|---|
| Type | Traditional direct vent gas fireplace, zero clearance |
| Input, natural gas | 13,500-19,100 BTU/h (0-2,000 ft) |
| Input, propane | 14,500-19,100 BTU/h with LPK-3732 |
| Ignition | IntelliFire IPI, 3 V; D-cell battery backup |
| Glass | Tempered |
| Overall width / depth | 36 in. / 18-1/16 in. (Fig. 3.1) |
| Vent size | 6-5/8 in. collar |
| Venting | DVP / SLP / SLP-FLEX, top or rear; co-linear option |
| Electrical | 110-120 VAC unswitched to the junction box |
| Certification | CSA/ANSI Z21.88-2019 / CSA 2.33-2019 |
Dimensions and clearances
- Overall width 36 in., depth 18-1/16 in.; decorative front 29 in. high x 30-15/16 in. wide (Figs. 3.1-3.2). Framing values are in Fig. 3.5; check the printed figure before framing.
- Clearances: 1/2 in. sides, 0 in. rear; 36 in. from heat-discharge openings (p.8+).
- Mantel legs and projections: combustible up to 3 ft each side, or unlimited on one side at least 5-7/8 in. from the opening; non-combustible unlimited (sect. 10).
- Combustible facing up to 1/2 in. thick allowed on the top and sides; finishing materials rated 190 F.
What's included
- Mercury 32 firebox and burner
- LOGS-MERC32 six-piece log set
- Embers and lava rock
- Decorative front and angled hood (SRV2401-021)
- Tempered fixed glass with barrier
- 3 VAC transformer
- Installation and owner's manuals
Required components
- Unit is complete — no required options needed.
- Mercury 32 requires a direct vent (DVP or SLP) venting system, not included with purchase.
Optional accessories
- GFK-160A fan kit
- 550-TRIM3-BK-B or 550-TRIM4-BK-B trim
- RCT-MLT-HHT remote, SMART-STAT-HHT thermostat remote, WSK-21-W wall switch
- Heat-Zone gas kit
- LPK-3732 propane conversion kit
- RF6 / RF12 or SLP-RF6 / SLP-RF12 roof flashing
Downloads
- Mercury 32 installation manual 2401-980, Rev U 11/25
- Mercury owner's manual and warranty 2401-981, Rev W 5/24
Installation and safety notes
⚠ Important: this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Majestic requires installation and service by a qualified installer, service agency or gas supplier, following the installation manual and local codes (installation manual 2401-980, p.1). If you ever smell gas, do not light any appliance, do not use electrical switches or phones in the building, leave the building and call your gas supplier from a neighbor's phone.
Product & safety information
- UL listed direct vent heater to CSA/ANSI Z21.88-2019 / CSA 2.33-2019; supplemental heat (pp.4-5).
- High altitude: U.S. reduce input 4% per 1,000 ft above 2,000 ft; Canada no reduction to 4,500 ft.
- Tempered glass; the supplied barrier must be installed; remove the splatter guard before the first fire.
Getting started
- Plan the vent route, gas and electrical first (pp.6-7); wall temperatures above the unit run about 100-150 F (Fig. 2.1).
Framing & clearances
- Frame per Fig. 3.5; 1/2 in. to combustibles at the sides, 0 in. rear; seal gaps with 300 F caulk (pp.8-12).
Termination location & vent information
- DVP or SLP rigid, SLP-FLEX (total horizontal reduced 25%, support every 4 ft) or SLP-FLEX7 with SLP-FLEX7A (Canada); never mix brands (pp.13-30).
- Top vent: up to four 90-degree elbows, horizontal up to 15 ft with one elbow, vertical up to 60 ft, V+H up to 40 ft; rear vent: up to three 90s, very short horizontal runs (24 in. with no elbow). Exhaust restrictor for 15-60 ft vertical.
- Co-linear: LINK-DV30B with DV-46DVA-GCL in an existing non-combustible chimney, 10-40 ft vertical. Caps: DVP-TRAP1/TRAP2, DVP-TRAPK1/K2, DVP-HPC1/HPC2.
- Termination clearances include 12 in. above grade, 9 in. (U.S.) / 12 in. (Canada) to opening windows, 18 in. under soffits, 30 in. under vinyl soffits, 3 ft to meters and mechanical air inlets (U.S.), 7 ft above walkways.
Vent clearances & framing
- Firestops and clearances per the vent tables; attic shield of 26-gauge steel 2 in. above insulation; elbow heat shield when V1 is under 1-1/2 ft (pp.31-33).
Appliance preparation
- Set the vent direction and any Heat-Zone preparation before installing (pp.34-38).
Venting & chimneys
- Seal and support the pipe per the manual; slope horizontal caps 1/4 in. down (pp.39-44).
Electrical
- Unswitched 110-120 VAC to the junction box, GFCI where required; 3 VAC transformer or two D-cell batteries; never wire line voltage to the valve or switch (pp.45-46).
Gas
- Natural gas inlet 5.0-10.0 in. w.c. (7.0 recommended), manifold 3.5; propane inlet 11.0-13.0 (12.0 recommended), manifold 10.0 (pp.47-48).
- Above 1/2 psig damages the valve; 1/2 in. T-handle shutoff and flex connector.
Finishing
- Finishes rated 190 F; combustible facing up to 1/2 in. on the top and sides; follow the mantel-leg limits (pp.49-50).
Appliance setup
- Place logs 1-6 in order on their pins, embers near (not on) the ports, no more than 3 lb of lava rock and none on the burner; hang the front and hood (pp.51-55).
Everyday use
- Break-in: windows open, 3-4 hours on high, cool, clean the glass, repeat if odors persist (owner's manual).
- Hot glass causes burns: keep children away and use a child lockout on remotes.
Building code information
- Gas installation: follow local codes or, where none apply, the current National Fuel Gas Code, ANSI Z223.1/NFPA 54 (U.S.) or the CSA B149.1 Natural Gas and Propane Installation Code (Canada)
- Electrical: wire and ground to local codes or, where none apply, the National Electrical Code, ANSI/NFPA 70 (U.S.) or the CSA C22.1 Canadian Electrical Code (Canada)
- Manufactured (mobile) homes: OEM installation to the Manufactured Home Construction and Safety Standard, Title 24 CFR Part 3280 (U.S.) or CAN/CSA Z240 MH Series (Canada)
- Massachusetts: installation by a licensed plumber or gas fitter under the Massachusetts fuel gas code (248 CMR); side-wall vents under 7 ft need a hard-wired CO detector with battery backup meeting NFPA 720 and ANSI/UL 2034
- Non-combustible materials are defined by ASTM E136 (published by ASTM International)
- Attic insulation shield where the vent passes an insulated attic, per the International Fuel Gas Code (ICC)
Warranty
- Coverage is the Hearth & Home Technologies (HHT) limited warranty, form 4021-645N (12/23), printed in the Mercury owner's manual 2401-981, Rev W 5/24, pp.1-2 of the warranty form. Majestic is an HHT brand.
- All parts and material, including handles and external enameled components: 1 year parts and labor (subject to the warranty conditions and exclusions).
- Electrical components (modules, remotes and wall switches, valves, pilots, blowers, junction boxes, wire harnesses, transformers and lights, excluding bulbs): 2 years.
- Cement refractory panels and glass liner panels: 2 years.
- Burners, logs and metal/fiber refractory components of HHT-manufactured fireplaces: 10 years parts, 1 year labor.
- Firebox and heat exchanger: 20 years parts, 3 years labor.
- Purchased replacement parts and optional accessories: 1 year parts, no labor.
- Who is covered: products bought from an HHT authorized dealer or distributor. Coverage transfers to later owners while the product stays at its original installation site, but the period is not extended. Valid only in the country where the selling dealer is authorized.
- When coverage starts: on the date of installation (new construction: six months after the final sale invoice, and no later than 24 months after HHT ships the product).
- How service works: warranty service is arranged through the installing dealer or distributor. Travel and parts-shipping charges are not covered.
- Key exclusions: normal wear items (paint, gaskets, firebricks, grates, flame guides, batteries, glass discoloration), normal finish color changes, noise from normal expansion and contraction, and damage from improper installation, operation or maintenance, code violations, negative pressure or inadequate ventilation, power interruptions, unauthorized modifications, non-HHT venting or a fuel other than the one specified. HHT does not guarantee heating capacity for a given space.
- The warranty is void if the product is over-fired, operated in a chlorine- or fluorine-contaminated atmosphere, or damaged by prolonged dampness, condensation or water from improper venting.
California Proposition 65
WARNING: This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Loading component details…
Add to cart to see your price.
