Majestic Products 32" Quartz Direct Vent Gas Fireplace QUARTZ32IFT is identified by model/SKU QUARTZ32IFT. Key product details include BTU: 21,000 (NG); 18,500 (LP); Size: 27-3/16 x 18-1/16".
Find your fit with the Quartz Series gas fireplace. In two models, it inspires cozy comfort and relaxation in a slim profile that preserves living space but warms spaces. Choose from traditional or modern styles to express your vision. For more ambiance, more heat and bigger flames, upgrade to the Quartz Platinum.
Features
- 11,250–21,000 Btu/Hour Input (NG)
- 10,000–18,500 Btu/Hour Input (LP)
- 5" x 8" rear vent collar
- 4" x 6 5/8" top vent collar
- 8 ceramic fiber logs
- Full firescreen front and hood
- Tempered glass
- Glowing embers
- Battery backup
- 12' control wire
- Convertible to contemporary
- IntelliFire Touch ignition
Special Considerations:
- Note: to change contemporary media color requires 2 bags
The standard decorative barrier front and log assembly are included. Correct fuel selection, approved venting and installation provisions are required separately.
- Requires SLP series or SLP-Flex series pipe when venting off top of unit.
- Requires DVP series pipe when venting off rear of unit.
- Approved for use with PVLP-SLP, PVI-SLP-B and PVV-SLP with power vent wire harness (order separately) and IFT-RC400
remote. See venting section of manual.
Specifications
| Model | Quartz 32 w/ IFT |
|---|---|
| Framing Width | 37" |
| Framing Depth | 16-1/4" |
| Framing Height | 34-3/4" |
| BTU/hr Input | 21,000 (NG); 18,500 (LP) |
| Viewing Area | 27-3/16 x 18-1/16" |
Service Parts
Architect Guides
CAD Drawings
Accessory Manuals
Model-specific specifications
| Base model / fuel variants | QUARTZ32IFT / QUARTZ32IFTN natural gas / QUARTZ32IFTL propane |
|---|---|
| Natural-gas input at 0–2,000 ft | 11,250–21,000 BTU/hr |
| Propane input at 0–2,000 ft | 10,000–18,500 BTU/hr |
| Ignition | IntelliFire Touch intermittent pilot |
| Glass | Tempered safety glass |
| Standard rough opening | 37 inches W × 34-3/4 inches H × 16-1/4 inches D; allow additional depth for rear-vent elbows and adjust for interior sheathing |
| Standard installation clearances | 1/2 inch behind and at sides; 36 inches in front; 32 inches to ceiling measured as shown in installation Figure 3.4. Mantel projections and vent clearances have separate requirements. |
| Electrical supply | Unswitched 110–120 VAC; minimum 14-2 AWG with ground |
| Emergency battery backup | Four AA batteries, not included; emergency use only |
| Appliance type | Direct-vent gas heater for supplemental use; not a primary heat source |
Included equipment and required installation
The standard log assembly, fixed glass assembly, decorative barrier front and hood provide the traditional fireplace configuration. The included barrier must remain installed during operation; a second optional front or remote is not a mandatory base purchase. Select the exact natural-gas or propane variant to match the installation. Fuel conversion requires a certified model-specific kit and qualified service. Approved venting, gas supply, electrical supply, framing and finishing must be provided separately.
Optional choices and controls
Approved brick or reflective-glass refractory liners, fan, heat-management systems and IntelliFire Touch controls are optional. The IFT-RC400 touchscreen remote, IFT-RC150 wireless wall switch and IFT-WFM Wi-Fi module are optional upgrades. Features depend on the accessories actually installed; a remote does not include a fan, light kit or power vent.
An approved contemporary conversion kit is available for this size. Follow that kit’s exact media and placement instructions; decorative glass is not required for the standard log configuration.
Venting and installation planning
The sealed direct-vent system takes combustion air from outdoors and exhausts outdoors. The manual approves HHT DVP and SLP systems and specified SLP flex systems, with model- and route-specific diagrams. Use the correct vent collar and adapters, follow permitted rise/run and termination clearances, and do not mix different manufacturers’ pipe or joining methods. SLP-FLEX configurations require the manual’s horizontal-run reduction. SLP-FLEX7 is Canada-only and requires its listed adapters. Each appliance requires its own vent.
Plan optional heat-management equipment while the appliance sides remain accessible. Rear venting with a 90-degree elbow adds depth beyond the standard rough opening. Mantels, television placement, vinyl flooring and combustible finishes require the detailed installation provisions, not just the base framing dimensions. Installation and service must follow the manufacturer documentation and applicable codes.
Operation, care and warranty
Use the fuel identified on the rating plate. The IntelliFire Touch system supports emergency battery operation, but AC-powered fans, lights and auxiliary functions are unavailable during an outage. Battery backup is not a long-term power source. Never operate with damaged or removed fixed glass or with the protective barrier removed. Have a qualified service technician verify log placement, gas tightness, glass sealing and controls before first use, and maintain the appliance under the owner manual.
HHT’s limited warranty provides component-specific coverage subject to authorized purchase, installation, maintenance, location and exclusions. Read the full schedule in the owner manual; do not assume all parts have identical coverage.