Kingsman Fibre Split Oak Log Set LOGF35
SKU / Model: LOGF35
Base price$469.35
Early Black Friday Savings applied in your cart
Unlock an exclusive offer on this product.
Product overview
The LOGF35 is a fibre split oak log set for the Kingsman FDV350 bay stove and the IDV34 fireplace insert. Fibre logs are light, very durable and hold a natural split-oak colour with crisp bark detail.
Four logs locate on pins in the log pan with a rear log holder, so the set goes together quickly and always lands where the flame was engineered to meet it. A bag of ember chunks spread one layer deep glows across the front burner.
It is the required log set for the FDV350 and one of the media choices for the IDV34 (the other is the RSP10 glass platform).
Key features
- Fibre split oak: lightweight ceramic-fibre logs with a natural split-oak finish
- Pin-located: logs A to D sit on locating pins and a rear log holder for repeatable placement (350-MAN19 p.14; 34IDV-MAN19-4 p.30)
- Glowing ember chunks: ember bag included; spread one layer deep on the front burner and log pan
- Two appliances: listed for the FDV350 stove and IDV34 insert
Specifications
| Part number | LOGF35 |
|---|---|
| Kingsman description | Log Set - Fiber Split Oak |
| Pieces | 4 logs, rear log holder, 4 log pins, ember chunks |
| Material | ceramic fibre |
| Fits | Kingsman FDV350, IDV34 |
| Shipping weight | 12 lb |
Compatible fireplaces
- Kingsman FDV350 stove: required (Kingsman price list: Log Set (Required))
- Kingsman IDV34 insert: one of the required media/trim choices (Kingsman price list: Log Set or Glass Support (Required for Each Unit))
What's included
- Logs A, B, C and D
- Rear log holder
- Four log pins
- Bag of ember chunks
Required components
- A Kingsman FDV350 stove or IDV34 insert
Optional accessories
- F35RL brick liner (FDV350)
- IDV33RL brick or IDV33PRL porcelain liner (IDV34)
Downloads
- FDV350 installation and operating manual (350-MAN19)
- IDV34 installation and operating manual (34IDV-MAN19-4)
Installation and safety notes
⚠ Important: this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (350-MAN19, 34IDV-MAN19-4). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.
Product and safety information
- Incorrect placement can cause sooting (350-MAN19 p.14; 34IDV-MAN19-4 p.30).
- Use only the media the appliance manual approves, in the quantities it lists. Parts not approved for the appliance can cause sooting, delayed ignition, property damage or injury.
Log installation (350-MAN19 p.14; 34IDV-MAN19-4 p.30)
- Log A: its two locating holes go over the two pins on the left of the mounting pan; log B over the two pins on the right.
- Log C: lower it just behind logs A and B, then pull it up against them; log D goes over the two pins on the left of log C.
- Spread the ember chunks on the front burner and log pan, no more than one layer deep.
Brick liner order (350-MAN19 p.13)
- If you add the F35RL brick liner, remove the rear log holder, fit the bricks, reinstall the holder, then the logs and door.
Use, care and maintenance
- Never cover the pilot or the pilot-to-burner crossover. You should always be able to see the pilot when lighting; if you cannot, the log or media placement is wrong.
- If sooting appears, turn the fireplace off, let it cool and reposition or remove the piece the flame is touching. Never alter the gas orifice.
- Logs, media and the glass get very hot. Only handle them when the fireplace is completely cool, and keep children and pets away from the glass.
- Have the logs, burner and pilot inspected and cleaned every year by a qualified service technician.
Building code information
- Install to local codes; where none exist, follow the current National Fuel Gas Code, ANSI Z223.1/NFPA 54, or in Canada CSA B149.1 (350-MAN19 p.7; 34IDV-MAN19-4 p.8).
- Any fan or light kit wiring: National Electrical Code, ANSI/NFPA 70, or CSA C22.1 in Canada.
- Manufactured-home installations follow the Manufactured Home Construction and Safety Standard, 24 CFR Part 3280 where the appliance is approved for them.
- Massachusetts: a licensed plumber or gas fitter must install the appliance, and CO detectors are required (NFPA 720).
Warranty
- The log set / media is a Kingsman component of the fireplace it is installed in. Kingsman prints its Limited Lifetime Warranty in each appliance manual (350-MAN19 p.53; 34IDV-MAN19-4 p.76).
- Basic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and are done by an authorized Kingsman dealer.
- Who is covered: the original owner, for an appliance that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada, installed and operated following the manual and local codes. Keep your installation records; without them coverage starts 30 days after the date of manufacture.
- How to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.
- Key exclusions: accident, abuse, misuse or negligence, faulty installation, unauthorized alteration, lack of maintenance, corrosive atmospheres, installation or removal costs and incidental or consequential damages.
California Proposition 65
WARNING: This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Loading component details…
Add to cart to see your price.

