Kingsman FDV350 Bay Direct Vent Gas Stove FDV350

SKU / Model: FDV350N

Free Fast Shipping
In-stock items are processed in 1–2 business days.

$2,741.03

Early Black Friday Savings applied in your cart

YOUR SPECIAL OFFER IS AVAILABLE

This product qualifies for an exclusive special offer.

Complete your selections and add this product to your cart to unlock the eligible offer.

Offer eligibility and final promotional pricing are confirmed in the cart. Accessories qualify separately. Offers may change.

Product overview

The Kingsman FDV350 Bay is a freestanding direct vent gas stove with a bay-window front: heat-radiating ceramic glass on three sides gives a panoramic view of the fire from across the room. It brings a traditional stove look to living rooms, cottages, basements and additions with no chimney, and it is approved for bedrooms, bed-sitting rooms and (as a direct vent stove) mobile homes.

A dual burner lights a realistic fire on the LOGF35 fibre split oak log set with embers, under a black louver. The front is completed with the F35DB black door frame and ceramic glass, and the optional F35RL brick liner adds a masonry look inside.

Input is 37,000 BTU/h on natural gas and 35,000 BTU/h on propane, with Hi/Lo flame and heat adjustment and a fireplace efficiency of up to 67.9% (NG) and 70.10% (LP). A millivolt valve needs no house power and IPI ignition has battery backup, so it keeps heating in a power outage; E2 models include a Proflame 2 remote. It vents through the wall or roof from a 4"/7" collar, or into an existing chimney or B-vent with the F35BVC converter.

Key features

  • Freestanding direct vent stove: sealed combustion; outside air for the fire.
  • Millivolt or IPI valve: operates during a power failure with Hi/Lo heat and flame adjustment.
  • Proflame 2 remote (E2 models): flame, fan, thermostat and smart thermostat control, with battery backup.
  • Dual burner: with a realistic flame pattern.
  • Heat-radiating ceramic glass: Robax or coated Neoceram, 5 mm.
  • Log set: LOGF35 Fibre Split Oak log set with ember chunks (ordered separately).
  • Safety screen barrier: F350CSS black-frame safety screen, listed as required for each unit.
  • Heat output: 37,000 / 29,000 BTU/h natural gas; 35,000 / 27,000 BTU/h propane (max/min).
  • Efficiency: FE 66.63% MV / 67.9% IPI (NG); 67.64% / 70.10% (LP).
  • Approvals: mobile home approved (direct vent only); bedroom and bed-sitting room approved.
  • Fan kit (optional): F45FK heat activated with variable speed control.
  • Wall thermostat (optional): Z2MT millivolt or Z80PT programmable.
  • Remote control (optional, millivolt): on/off, thermostatic, thermostatic modulating.
  • Refractory brick liner (optional): F35RL.
  • Black door frame with ceramic glass (required, sold separately): F35DB completes the stove front.
  • B-vent adapter (optional): F35BVC converts the stove to an existing 4" B-vent or lined chimney.
  • Field conversion: kits 350DV-CKLP / -CKNG (millivolt) and 350DV-CKLPI / -CKNGI / -CKLPI2 / -CKNGI2 (IPI).
  • Certification: CSA/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.

Specifications

Models FDV350N / FDV350LP (millivolt); FDV350NE2 / FDV350LPE2 (IPI Proflame 2 with remote)
Type Freestanding direct vent gas stove
Unit dimensions Not published by the manufacturer
Framing dimensions None required (freestanding). Alcove installation: at least 30" deep, 55-1/2" high and 52-1/2" wide
Viewing area Not published by the manufacturer (ceramic glass on three sides)
Clearances to combustibles Front 36"; sides 12"; back 3"; corner (45°) 3"; top of a 90° elbow 4"; top of horizontal pipe 2-1/2"; vertical venting 1"; all other existing pipes 1". Floor: may sit directly on carpet, tile or other combustible flooring; a hearth is recommended over luxury vinyl flooring
Input, natural gas (max / min) 37,000 / 29,000 BTU/h
Input, propane (max / min) 35,000 / 27,000 BTU/h
Fireplace efficiency (FE) 66.63% MV / 67.9% IPI (NG); 67.64% / 70.10% (LP)
Glass Ceramic, 5 mm
Venting Direct vent, 4"/7" flue collar. Rigid DuraVent DirectVent Pro 4" x 6-5/8" pipe with the Kingsman ZDVDKA stove adapter (horizontal or vertical termination); optional 4" B-vent with F35BVC
Ignition Millivolt or IPI Proflame 2
Gas inlet 3/8" NPT
Certification CSA/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017

Included components

  • Stove with dual burner and black louver, set up for the selected fuel and ignition
  • Ember chunks
  • Proflame 2 remote (FDV350NE2 / FDV350LPE2 only)

Required components

  • LOGF35 fibre split oak log set with embers (required for each unit)
  • F35DB door frame and ceramic glass, black (required for each unit)
  • F350CSS safety screen, black frame (listed by Kingsman as required for each unit)
  • Direct vent pipe from the 4"/7" collar: Kingsman (Z-Flex) venting components labelled for this stove, or DuraVent DirectVent Pro 4" x 6-5/8" rigid pipe; BDM Pro Form, Ameri-Vent, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp direct vent systems are also approved
  • ZDVDKA DuraVent hard-pipe stove adapter (required with rigid DuraVent pipe)
  • One termination: FDVHSQ or FDVHT horizontal, FDVVT40 vertical, or Z47ST24 / Z47ST36 snorkel
  • Vertical installs: ZDVFS firestop spacer (required through floors and ceilings), ZDVAIS attic insulation shield and ZDV7SC storm collar
  • Or, instead of direct vent pipe: F35BVC B-vent converter into an existing 4" B-vent or lined chimney, 12 ft minimum to 60 ft maximum (not allowed in mobile homes)
  • Gas supply with manual shutoff (3/8" NPT)
  • 120 VAC grounded receptacle for the fan or IPI models
  • Four AA batteries for IPI battery backup

Optional accessories

  • F35RL refractory brick liner
  • F45FK fan kit with variable speed control (millivolt / Proflame 1 models)
  • F45FK2 fan kit (Proflame 2 models)
  • F7DBC decorative black collar, 7"
  • F7DTP decorative black wall trim plate
  • Z2MT millivolt wall thermostat
  • Z80PT programmable digital millivolt wall thermostat
  • GFRC on/off remote (millivolt / IPI)
  • GTRC thermostat remote (millivolt)
  • GTMRCN thermostat / modulating remote, natural gas (millivolt)
  • GTMRCP thermostat / modulating remote, propane (millivolt)
  • GTFRCN / GTFRCP thermostat / modulating remote with fan control (millivolt)
  • WMBH wall mount battery holder (IPI models)
  • ZDVSSLR vinyl siding shield

Downloads

Installation and safety notes

⚠ Important: this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (FDV350 installation and operating manual (350-MAN19), safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.

Product and safety information (pp.1–9)

  • Certified to CSA/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).
  • Mobile home approved (direct vent only; not when converted to B-vent); approved for bedrooms and bed-sitting rooms.
  • In Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).

Location, clearances and floor (pp.10)

  • Clearances: front 36", sides 12", back 3"; corner (45°) 3"; top of a 90° elbow 4"; horizontal pipe top 2-1/2" (p.10).
  • Alcove: at least 30" deep, 55-1/2" high and 52-1/2" wide (p.10).
  • Install on a hard, stable surface; carpet and tile are fine, a hearth is recommended over vinyl.

Accessories, liners and logs (pp.11–15)

  • F45FK fan: variable speed control, needs a grounded 120 VAC receptacle.
  • Log set: LOGF35 Fibre Split Oak log set with ember chunks (ordered separately); follow the placement diagram and keep the pilot clear.
  • Replacement glass must be 5 mm Robax or coated Neoceram; substitute glass voids the warranty.

Gas, maintenance and conversion (pp.16–19)

  • Natural gas supply 5.5" min / 7" normal / 9" max w.c.; manifold 3.5" high / 1.6" low w.c. (p.16).
  • Propane supply 11" min / 11" normal / 12" max w.c.; manifold 10" high / 6.3" low w.c. (p.16).
  • 3/8" NPT inlet; minimum 3/8" iron pipe for natural gas with at least 4.5" w.c. at the meter; 1/2" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1/2 psig (p.16).
  • Orifices are sized for 0–4,500 ft elevation (p.16). Field conversion between natural gas and propane uses Kingsman kits 350DV-CKLP / -CKNG (millivolt) and 350DV-CKLPI / -CKNGI / -CKLPI2 / -CKNGI2 (IPI) (p.17), installed by a qualified agency (pp.17–19).
  • Have the burner, pilot and venting inspected every year by a qualified technician.

Controls and ignition (pp.20–39)

  • Millivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.20–39).
  • IPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.
  • Proflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).

Venting (pp.40–49)

  • Venting: Direct vent, 4"/7" flue collar. Rigid DuraVent DirectVent Pro 4" x 6-5/8" pipe with the Kingsman ZDVDKA stove adapter (horizontal or vertical termination); optional 4" B-vent with F35BVC.
  • Minimum vertical 4-1/2 ft (stove 4" from the wall); maximum vertical 40 ft; maximum horizontal 20 ft with one 90° elbow and 7 ft of vertical; 1/4" rise per 12" of run.
  • Each extra 90° elbow takes 36" off the horizontal run and each 45° takes 18"; propane horizontal runs need 1 ft more vertical rise.
  • B-vent conversion with F35BVC into an existing 4" B-vent or lined chimney, 12–60 ft.

First fire and everyday use

  • Break-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).
  • After turning it off, wait at least 60 seconds before relighting (p.5).
  • The glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).
  • Never burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).
  • Install carbon-monoxide detectors on every level and near bedrooms (p.7).

Building code information

Warranty

  • Coverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (FDV350 installation and operating manual (350-MAN19), p.53).
  • Basic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.
  • Limited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.
  • Not covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.
  • Who is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.
  • Proof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.
  • How to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.
  • Key exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.

California Proposition 65

WARNING: This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to www.P65Warnings.ca.gov.

Flames and flame colors on the website may appear differently in real life.

Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.

Frequently asked questions — FDV350

What do I need to order to complete the FDV350?

Kingsman lists three parts as required for each unit: the LOGF35 fibre split oak log set with embers, the F35DB black door frame with ceramic glass, and the F350CSS black-frame safety screen. You also need the venting (or the F35BVC B-vent converter) and a 3/8" NPT gas supply.

Does the FDV350 need framing or a hearth?

No framing is needed; it is a freestanding stove. In an alcove the space must be at least 30" deep, 55-1/2" high and 52-1/2" wide. It can sit directly on carpet, tile or other combustible flooring; a hearth is recommended over luxury vinyl. Clearances are 36" in front, 12" at the sides, 3" at the back and 3" in a 45° corner.

What venting does it use, and how far can it run?

It is direct vent from a 4"/7" collar to an FDVHSQ or FDVHT horizontal, FDVVT40 vertical, or Z47ST24 / Z47ST36 snorkel termination. The vertical rise can be up to 40 ft, and the horizontal run up to 20 ft with one 90° elbow and 7 ft of vertical; the shortest setup is 4-1/2 ft vertical with the stove 4" from the wall. Each extra 90° elbow takes 36" off the horizontal run.

Can it vent into an existing chimney or B-vent?

Yes, with the F35BVC B-vent converter: 12 ft minimum to 60 ft maximum, with at least 57-1/4" to the top of the elbow. A masonry clay-lined chimney needs a liner if it is wider than 5" inside, and a wood-burning or B-vent chimney if wider than 6". A stove converted to B-vent cannot be installed in a mobile home.

Can the FDV350 be converted between natural gas and propane?

Yes, with Kingsman kits 350DV-CKLP / -CKNG (millivolt) or 350DV-CKLPI / -CKNGI / -CKLPI2 / -CKNGI2 (IPI), installed by a qualified agency. Input is 37,000 / 29,000 BTU/h on natural gas and 35,000 / 27,000 BTU/h on propane (max/min).

Does it work in a power outage?

Yes. Millivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in an outage; the optional fan does not run on battery.

Loading component details…

Add to cart to see your price.

Call for best price