DuraVent DuraChimney II 14" Chase Stabilizer 14DCA-ST
SKU / Model: 14DCA-ST
Base price$100.00
Unlock an exclusive offer on this product.
Product overview
The 14DCA-ST is the stabilizer for 14" DuraVent DuraChimney II chimney, the system listed for the Majestic Ashland 50 wood fireplace. It is used inside chase enclosures to keep the chimney vertical and centered and help maintain clearances. It is a venting support part, not a fireplace.
DuraVent notes the stabilizer does not support the chimney's weight; secure its legs with plumber's tape or guy wires.
Specifications
| Manufacturer part number | 14DCA-ST (DuraVent stock 810000832) |
|---|---|
| Listed dimension | 17-3/8" (A) |
| Use | Inside chase enclosures; not a weight support |
| Fireplace application | Majestic Ashland 50 (ASH50) per distributor catalog |
Installation and safety notes
In enclosures, use a wall strap or stabilizer at least every 8 ft. Supplementary supports are required if total height exceeds 50 ft.
Maintain at least a 2" air space to combustibles and never fill it with insulation (DuraChimney II instructions). The 14" size requires a 21" x 21" framed opening, and 10"–16" sizes are joined with four sheet metal screws per section.
Exact-model manuals and downloads
DuraVent DuraChimney II catalog, DV_DCII_CT-001E-10-24: page 7 lists 14DCA-ST
DuraVent DuraChimney II Installation Instructions, L180 / 820003154 (Rev 4.5.2017): pages 9 and 13 cover stabilizer use
Ray Murray 2026–27 Hearth Catalog, pp. 296–304: page 296 lists the Majestic Ashland 50 as using 14" DuraVent DuraChimney II
Frequently asked questions — 14DCA-ST
Which Majestic fireplace uses 14" DuraChimney II?
Ray Murray's 2026 catalog lists the Majestic Ashland 50 (ASH50) with 14" DuraVent DuraChimney II, and HHT's ASH50 service parts list includes 14DCA parts. Confirm in your fireplace's installation manual.
Does the stabilizer carry the chimney weight?
No. DuraVent says it keeps the chimney centered and vertical but does not support its weight.
How often is one needed?
In enclosures, use a wall strap or stabilizer at least every 8 ft, per DuraVent's instructions.
Where is it used versus the wall strap?
The stabilizer is for inside chase enclosures; the 14DCA-WS wall strap is required every 8 ft on building exteriors.
Compatibility
Majestic lists this part by part number in the installation manuals of these appliances sold on our store:
- Majestic 50" Ashland Wood Fireplace ASH50-B (listed in the Ashland 50 installation manual 4059-970 Rev J (8/26), p.15, 40)
- Majestic Castlewood 50 Outdoor Wood Burning Fireplace ODCASTLEWD-50 (listed in the Castlewood ODCASTLEWD-50 installation manual 4170-900 Rev J (8/26), p.16, 41)
If your appliance is not listed, check its installation manual or contact us before ordering.
Installation notes
- Install this part following the installation manual of the appliance it is used with (pages cited above) and the instructions packed with the part.
- Ashland 50 installation manual 4059-970 Rev J (8/26)
- Castlewood ODCASTLEWD-50 installation manual 4170-900 Rev J (8/26)
- United Fireplaces recommends that every appliance and its components be installed by a qualified professional installer.