Product overview

The Superior WCT4920 is a compact, high-efficiency wood-burning fireplace from Innovative Hearth Products for homeowners who want the sound, smell and glow of a real wood fire with heat they can use. It is an EPA-certified, non-catalytic, combustion-controlled wood heater in a zero-clearance body, suited to family rooms, dens and smaller living spaces without the size, weight or cost of masonry.

You choose the look from three facades and three doors: arched (louvered arch-open facade with a smooth-steel or cast-iron arched door) or square (louvered or Clean Face square-open facade with the steel square-pane door). White smooth refractory panels frame the fire, and an air wash keeps the glass clear. It shares its framing, firebox and performance with the WCT6920; pick the WCT4920 for more square and arched looks and smooth white refractory, or the WCT6920 for brick-style stacked refractory.

Superior rates it at up to 55,000 BTU and about 1,500 square feet, depending on the home, insulation, climate and wood. A heat-activated blower and an outside air kit come included, and HeatFlo or forced-air kits can carry warm air further.

Key features

  • Circulating design: facade, square or arch doors and ceramic glass for optimum heat transfer, with a durable high-temperature paint finish.
  • EPA certified, non-catalytic: variable-rate certified high-efficiency wood heater (EPA cert. 403-25), 1.5 g/hr, 61% estimated efficiency (HHV); clean burning with no combustor to replace.
  • Insulated firebox: 2.0 cu ft (Superior; 2.19 cu ft overall per the manual) that accepts logs up to 19 in.; 16-17 in. pieces burn best.
  • Smooth white refractory panels: with an integrated ash lip and steel log retainer.
  • Air combustion control and air wash: one control sets variable heat output, with an air boost for faster wood ignition during start-up; the air-wash system keeps the glass clean.
  • Heat output: 55,000 BTU and heats up to about 1,500 sq ft per Superior (approximate); EPA test range 14,500-81,000 BTU/hr.
  • Blower and outside air included: factory-installed, heat-activated 200 CFM variable-speed blower for time-delayed heat distribution; insulated outside air kit included and required for use.
  • Square or arched looks: three facades (louvered arch, louvered square, Clean Face square) and three doors (steel square pane, smooth-steel arched, cast-iron arched), with a heat-resistant door handle that stays cool to the touch.
  • HeatFlo and forced-air options: EPA-HEATFLO-KIT convection kit (two 8 in. ducts to wall louvers; mandatory with the Clean Face facade) and/or the thermostatically controlled forced-air kit BISFWK-1 (three outlets maximum).
  • Approved, listed and warranted: mobile and manufactured home approved (solid fuel only); UL 127 and ULC-S610 factory-built fireplace (report 14-199); 20-year limited warranty on the product body and firebox.

Specifications

Model WCT4920 (store SKU WCT4920WS; current manual covers WCT4920WSS, unit F5120)
Type EPA-certified non-catalytic wood-burning fireplace, front view, zero clearance
Unit dimensions 37-1/4" W x 38" H x 25-1/8" D (spec sheet 901490-00 product table; width measured to the standoffs, 36" across the fireplace face)
Framing dimensions 37-1/4" W x 56" H x 25-1/8" D rough framing (depth for flush framing installations), 2x3 lumber minimum; the rough framing face dimension includes any finish material inside the framing (spec sheet 901490-00; manual p.11). Corner installation: 79-1/4" across the front and 39-5/8" from the front to the corner. Leave 8" minimum beside the unit for the outside air kit.
Viewing area 22-5/8" W x 10-7/8" H firebox opening, as dimensioned on the spec sheet 901490-00 front view (bottom of the opening 12-7/8" above the base)
Clearances to combustibles Back and sides 0" to the standoffs; bottom 0"; side wall 24" from the firebox opening; ceiling 6 ft 8 in. minimum from the fireplace base; chimney 2"; nothing but the wood framing may fill the space above the fireplace; mantel non-combustible only, 39-1/2" minimum above the base, 16" maximum depth; non-combustible hearth extension 16" deep (US) / 18" (Canada), 39" wide and 8" past each side of the opening (manual p.9)
Heat output EPA test 14,500-81,000 BTU/hr; 55,000 BTU per Superior
Efficiency 61% estimated (HHV, CSA B415.1)
Emissions 1.5 g/hr (40 CFR Part 60)
Heating area Up to about 1,500 sq ft (approximate, per Superior)
Firebox volume 2.0 cu ft (Superior); 2.19 cu ft overall, 1.52 cu ft EPA usable (manual)
Log length Up to 19 in. (Superior); optimal 16-17 in. pieces (manual)
Flue 6 in. diameter
Chimney US: IHP 6 in. Snap-Pak (UL 103HT); Canada: Security Secure Temp ASHT+ or S2100+, or DuraVent DuraTech Canada / DuraTech Premium
Blower Heat-activated 200 CFM variable-speed blower, factory installed; 120 VAC, 60 Hz
Outside air Included: 4 in. insulated flex (up to 10 ft) and 4 in. adaptor
Unit weight 330 lb (manual p.28)
Shipping weight (estimated) 363 lb
Listing UL 127 / ULC-S610, report 14-199
Warranty 20-year limited (body and firebox)

Dimensions and clearances

  • Unit: 38 in. high x 37-1/4 in. wide x 25-1/8 in. deep; weight 330 lb (manual p.28).
  • Viewing: 22-5/8 in. wide x 10-7/8 in. high firebox opening on the spec sheet front view; 36 in. across the fireplace face.
  • Corner installation: 79-1/4 in. across the front and 39-5/8 in. from the front to the corner (spec sheet 901490-00).
  • Framed opening: 37-1/4 in. wide x 56 in. high x 25-1/8 in. deep for a flush install, framed with 2x3 lumber minimum; headers only where needed to carry facing and mantel (p.11).
  • Clearances to combustibles: 0 in. at the back and sides (to the standoffs) and bottom; 2 in. around the chimney; side wall 24 in. from the firebox opening; ceiling 6 ft 8 in. from the fireplace base. Nothing but wood framing may fill the space above the fireplace, and the fireplace must not touch insulation or loose fill (p.9).
  • Hearth extension: non-combustible, at least 16 in. deep in the US (18 in. in Canada), at least 39 in. wide and 8 in. beyond each side of the firebox opening, with the safety metal strip across the full width (p.9).
  • Mantel: non-combustible only, at least 39-1/2 in. above the base of the unit, 16 in. maximum depth (p.9).

What's included

  • Fireplace with white smooth refractory panels, integrated ash lip and steel log retainer
  • Factory-installed heat-activated 200 CFM variable-speed blower
  • Insulated outside air kit (4 in. insulated flex, up to 10 ft, and 4 in. adaptor)

Required (sold separately)

  • Facade (required, choose one): louvered arch open black FLVAOBLK (F4781), Clean Face square open black FCFSOBLK (F4782; requires the HeatFlo kit EPA-HEATFLO-KIT), or louvered square open black FLVSOBLK (F4783)
  • Door (required, matched to the facade): arched facade - smooth-steel arched black BTCECBK (F1849) or cast-iron arched black BTCECBKC (F1851); square facades - steel square-pane black DSSPBLK (F4780)
  • Chimney: IHP 6 in. Snap-Pak in the US (Canada: Security ASHT+/S2100+ or DuraVent DuraTech Canada / DuraTech Premium), at least 12 ft (15 ft with offsets), with rain cap 6SPC, roof flashing (6SPFF, 6SPF5 or 6SPF10 by pitch) and storm collar 6SPSC, firestop 6SPFS at each floor or ceiling, and chimney lengths 6SPS24 / 6SPS36 / 6SPS48
  • Attic insulation shield 6SPIS where the chimney passes an insulated attic
  • Non-combustible hearth extension material (by the installer)
  • 120 VAC electrical supply for the blower (by a qualified electrician)

Optional accessories

  • HeatFlo convection kit EPA-HEATFLO-KIT (F3790); mandatory with the Clean Face facade
  • Central forced-air kit BISFWK-1 with 5 in. flex 5FLEX15 (15 ft) or 5FLEX25 (30 ft)
  • Heating/cooling thermostat HCTW
  • Variable speed control VRUW (not stocked here)
  • Snap-Pak supports and bands: adjustable support 6SPAS, support band 6SPSB, wall band 6SPWB, roof brace 6SPRB, wall firestop 6SPWF
  • Outside air duct UZI and adaptor UZIAD (extra lengths)

Product video

Official Superior videos for the WCT4920:

Installation and safety notes

⚠ Important: A wood fireplace that is installed, operated or maintained incorrectly can cause a house fire or carbon-monoxide exposure. This fireplace must be installed by a qualified professional following the Superior installation manual (WCT4920WSS, P/N 901489-00), with only the listed chimney components, and inspected by your local building official where required.

Product and safety information

  • Listed to UL 127 and ULC-S610 (report 14-199) as a factory-built fireplace; EPA certified (cert. 403-25) to 40 CFR Part 60, 1.5 g/hr (pp.2, 28, 30).
  • Required parts: a facade and a matching door; optional equipment is listed on p.2 and p.27.
  • Do not alter the fireplace, and never install a gas log set or insert in it (pp.3-5).
  • Install smoke and carbon-monoxide detectors in the home (p.5).

Mobile or manufactured homes

  • Approved with solid fuel only, per HUD (US) or CMHC (Canada) requirements. Fasten the fireplace to the floor through the tabs at the bottom of both sides, keep the structure intact, provide inspection access in built-in enclosures, place the vapor barrier close to the chimney penetration, fit an attic radiation shield under a flat roof, and never install it in a sleeping room (p.3).

Fuel, operation and first fires

  • Burn only solid, dry, seasoned natural wood (11-20% moisture; softwood seasoned 6-18 months, hardwood 12-24 months); never garbage, treated or painted wood, plywood, particleboard, cardboard, plastic, coal or salt-water driftwood (pp.4, 6).
  • Use the combustion control to set heat output; do not overfire (p.4).
  • Break-in: remove plastic wrap, labels and glue residue, then keep the first five or six fires small, about 30-60 minutes each, to cure the refractory; expect some odor and smoke and ventilate the room (p.2).
  • Keep the door closed while burning. Surfaces get very hot and stay hot after the fire dies: supervise children and pets (pp.3, 5).

Maintenance

  • Have the fireplace and chimney inspected and cleaned regularly to control creosote, and know what to do in a chimney fire (p.6).
  • Remove ashes only when cold and store them in a closed metal container away from combustibles (p.7).
  • Care for the door finish and glass as described (pp.7, 10).

Refractory, doors and facade

  • Install the refractory panels, then the chosen door, and adjust the door; install the facade before finishing (pp.8-9).
  • Cold climates: follow the cold-climate guidance for exterior walls and chases (p.8).

Framing, facing, hearth and mantel

  • Framed opening 37-1/4 x 56 x 25-1/8 in. (flush), 2x3 lumber minimum; 6 ft 8 in. minimum ceiling height from the base; attach through the nailing flanges (pp.9, 11, 14).
  • Clearances: 0 in. back, sides and bottom to standoffs; 24 in. side wall from the opening; 2 in. at the chimney (p.9).
  • Non-combustible hearth extension 16 in. deep (US) / 18 in. (Canada), 39 in. wide, 8 in. past each side of the opening. The manual text asks for 1/2 in. thick material while the label allows 3/8 in. or equivalent, so plan on 1/2 in. Raised hearths use field-supplied "Z" metal strips overlapping at least 1 in. (p.9 and label).
  • Mantel: non-combustible only, 39-1/2 in. minimum above the base, 16 in. maximum depth (pp.9, 14).

Blower and electrical

  • The heat-activated blower runs on 120 VAC, 60 Hz, single phase; a qualified electrician wires it at the junction box on the right side before the finishing materials go on. An optional VRUW speed control wires in line with the supply (pp.15-16).

Outside air kit

  • The included outside air kit is mandatory. Use up to 20 ft of 4 in. insulated flex (5 in. up to 30 ft, 6 in. up to 40 ft); the intake must draw outdoor air (not attic, basement or garage air) and sit no more than 10 ft above the fireplace base; wall hole 4-1/4 in. (p.16).

HeatFlo convection kit

  • The EPA-HEATFLO-KIT uses two 8 in. ducts, both outlets connected, 10 ft maximum each; louver center at least 68 in. above the base, 11 in. from ceilings and side walls; 13 x 13 in. wall penetration with a firestop and 1 in. clearance; grilles point down; never connect it to a central heating system. It is mandatory with the Clean Face facade (pp.17-19).

Chimney system

  • Use only 6 in. IHP Snap-Pak components in the US, or Security Secure Temp ASHT+/S2100+ or DuraVent DuraTech Canada/DuraTech Premium in Canada (pp.20-21, 25).
  • Minimum chimney height 12 ft (15 ft with offsets); add 18 in. for every 2,000 ft above sea level (p.20).
  • Termination: at least 3 ft above the roof contact point and 2 ft above any roof or wall within 10 ft (the ten-foot rule); a rain cap is required (pp.20, 24).
  • Offsets: up to two offsets (four elbows), 15 or 30 degree, no more than 30 degrees from vertical (pp.20, 23).
  • The fireplace carries up to 9 ft of chimney; use supports above that (p.20).
  • Above the roof, the manual asks for extra support once the chimney extends more than 4 ft (p.24; p.20 says 5 ft) - plan on bracing above 4 ft: roof brace for 4-8 ft, guy wires for 8-20 ft.
  • Keep 2 in. clearance from the chimney to combustibles; use a firestop spacer at every floor or ceiling (p.21). Install the roof flashing and storm collar per p.23.
  • In a chase, terminate at least 18 in. above the chase top; separate multiple terminations by at least 16 in. horizontally and 18 in. vertically (p.25).
  • Masonry chimneys need a stainless liner listed to UL 1777 (US) or ULC-S635/S640 (Canada), rated 2100°F (p.26).

Installation accessories

  • Facades FLVAOBLK / FCFSOBLK / FLVSOBLK, doors DSSPBLK / BTCECBK / BTCECBKC, outside air UZI / UZIAD, HeatFlo kit EPA-HEATFLO-KIT, forced-air kit BISFWK-1 with 5FLEX15 / 5FLEX25, thermostat HCTW (p.27).

Building code information

Warranty

  • Coverage: Superior wood-burning fireplace 20 Year Limited Warranty, printed in the installation manual (P/N 901489-00 Rev. NC, p.31).
  • Product body and firebox: 20 years from installation. Ceramic glass: thermal breakage only.
  • Removable air tubes: 7 years (IHP labor rates in years 1-5). Refractory, side shields and screens: 2 years (hairline cracks excluded). Gold and nickel plating: 2 years (tarnishing excluded).
  • Air tubes, baffles, brick retainers, cast-iron parts, gaskets and electrical components: 1 year. Optional glass doors: 90 days. Fuel grates: 90 days (defects only). Parts not listed: 90 days.
  • Vent components, trim, paint and applied stains are not covered.
  • Labor: paid at IHP's prevailing rates during each component's warranty period, up to five years.
  • Who is covered: the original owner only (not transferable), bought from a listed IHP supplier with proof of purchase, installed in the US or Canada.
  • Conditions: installed and repaired by a licensed, IHP-approved contractor to codes, using only the chimney components specified in the manual, burning approved fuels, and operated and maintained per the instructions.
  • Exclusions: normal wear; accident, fire or flood; abuse, negligence or alteration; unapproved fuels (driftwood, coal, plywood, binder-based products); lack of maintenance; faulty installation; draft or smoking problems from HVAC, chimney height, trees, buildings or wind; utility costs; incidental damages.
  • Claims: contact the selling dealer; if that is not possible, notify IHP in writing within 90 days of the failure. Replacement parts are generally available for 10 years after the last manufacture date.

Downloads

California Proposition 65

WARNING: This product can expose you to chemicals including carbon black, which is known to the State of California to cause cancer, and carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

Flames and flame colors on the website may appear differently in real life.

Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.

Frequently asked questions — WCT4920

What size framing does the WCT4920 need?

Frame a rough opening 37-1/4 in. wide x 56 in. high x 25-1/8 in. deep (the depth is for flush framing) with 2x3 lumber minimum. The rough framing face dimension includes any finish material inside the framing. A corner installation needs 79-1/4 in. across the front and 39-5/8 in. from the front to the corner. Keep a 6 ft 8 in. minimum ceiling height from the fireplace base. The fireplace itself is 37-1/4 in. wide x 38 in. high x 25-1/8 in. deep.

What chimney does it use, and how tall must it be?

A 6 in. IHP Snap-Pak chimney in the US, or Security Secure Temp ASHT+ / S2100+ or DuraVent DuraTech Canada / DuraTech Premium in Canada. The minimum system height is 12 ft (15 ft with offsets), plus 18 in. for every 2,000 ft above sea level. Offsets use 15 or 30 degree elbows, and the top must end at least 3 ft above the roof and 2 ft above anything within 10 ft, with a rain cap.

How many square feet does it heat?

Superior rates it at up to about 1,500 sq ft and 55,000 BTU, depending on the home, insulation, climate and wood. The EPA test heat output range is 14,500 to 81,000 BTU/hr, with 61% estimated efficiency (HHV).

Which facade and door do I need?

One facade and a matching door are required and sold separately. For an arched look use the louvered arch open facade FLVAOBLK with the smooth-steel arched door BTCECBK or the cast-iron arched door BTCECBKC. For a square look use the louvered square open facade FLVSOBLK or the Clean Face square open facade FCFSOBLK with the steel square-pane door DSSPBLK. The Clean Face facade also requires the HeatFlo kit EPA-HEATFLO-KIT.

What hearth and mantel does it need?

A non-combustible hearth extension at least 16 in. deep in the US (18 in. in Canada), 39 in. wide and 8 in. beyond each side of the opening; the manual text asks for 1/2 in. thick material. A mantel must be non-combustible, at least 39-1/2 in. above the base of the unit and no deeper than 16 in.

What is the warranty?

20 years on the product body and firebox from installation; ceramic glass is covered for thermal breakage only. Removable air tubes are covered for 7 years, refractory, side shields and screens for 2 years, cast-iron parts, gaskets and electrical components for 1 year, and optional glass doors for 90 days. Coverage is for the original owner only.