Superior 84" Linear Direct Vent Gas Fireplace DRL6084TEN
SKU / Model: DRL6084TEN
Fireplace only$15,869.00
Black Friday Savings applied in your cart
Unlock an exclusive offer on this product.
Product overview
The Superior DRL6084TEN is the 84-inch model in the DRL6000 Series, a clean-face linear direct vent gas fireplace made by Innovative Hearth Products. It is built for contemporary and transitional rooms where a long, low flame is the focal point, and it suits homeowners who want real heat and a fully equipped fireplace without hunting for add-ons: a heat-circulating blower, floor lighting and a multi-function remote all come standard.
The look is wide and uncluttered. A large ceramic glass opening frames a ribbon of flame dancing over platinum crushed glass, set against a black porcelain liner that reflects the fire back into the room. Mood-enhancing floor lighting glows through the media with or without the burner on. You can change the character of the fire with optional reflective black or reflective blue crushed glass, large Onyx, Diamond or Sapphire glass, a high-definition driftwood log set, or a five-piece reflective black glass liner.
Heat output is 50,000 BTU/hr on natural gas, with six flame settings and up to a 30% turn-down for precise control. The factory-installed six-speed blower moves warm air into the room, and the optional HeatFlo kit can redirect heat out through vents above the fireplace, so you can hang art or a TV above it with less heat reaching the wall. Superior rates the series for outstanding heating efficiency and lower operating costs.
Control is simple. Electronic ignition (selectable intermittent or continuous pilot) runs on household power, with battery backup that keeps the fire working in a power outage. The included Proflame multi-function remote handles on/off, thermostat and smart-thermostat modes, six flame levels, six light levels and six blower speeds.
Installation is flexible. The fireplace vents through Superior 6DVL 6"x9" direct vent pipe, horizontally through a wall or vertically through the roof, with up to 40 ft of vertical rise. Where a standard vent route will not work, an optional power vent system allows down-and-out runs. A clean-face design with integrated tile stops makes finishing easy, and an indoor see-through conversion kit lets the same fireplace be viewed from two rooms. Compared with the DRL4000 Series, the DRL6000 adds the standard blower, floor lighting and multi-function remote as built-in features.
Key features
- Linear clean-face design: integrated tile stops let finish materials run right up to the opening for a modern, frameless look.
- 84-inch size: part of a family of 48, 60, 72 and 84-inch DRL6000 models.
- Indoor see-through option: the see-through conversion kit allows viewing from two living spaces (blower use is not compatible with see-through).
- HeatFlo kit option: directs heat above heat-sensitive wall hangings.
- Electronic ignition with battery backup: continued operation in the event of a power outage (blower and lights do not run on battery).
- Selectable IPI/CPI pilot: run an intermittent pilot for savings or a continuous pilot for cold-climate use.
- Six flame settings: up to a 30% turn-down for precise heat control.
- Outstanding heating efficiency: for increased comfort and lower operating costs.
- Ceramic glass with protective screen: optimum heat transfer, with a barrier screen that meets ANSI Z21.50/88 requirements.
- Factory-installed blower: six speed settings to fine-tune heat output.
- Black porcelain liner: a reflective view of the fire.
- Platinum crushed glass included: 5 five-pound bags supplied; optional reflective black, reflective blue and large Onyx/Diamond/Sapphire glass available.
- Floor lighting: six-level accent lighting enhances the interior with or without a fire.
- Multi-function remote included: on/off, IPI/CPI, thermostat and smart thermostat, flame height, blower and lights.
- Optional power vent: allows down-and-out vent installations.
- Natural gas, field-convertible to propane: with the Superior conversion kit.
- Certified: listed to ANSI Z21.88/CSA 2.33 and CSA 2.17 as a vented gas fireplace heater (report F18-195).
- 20-year limited warranty: on the firebox, product body and barrier.
Specifications
| Model | DRL6084TEN (natural gas, electronic ignition) |
|---|---|
| Series | Superior DRL6000 linear direct vent |
| Type | Direct vent gas fireplace, clean-face, front view (see-through with kit) |
| Unit dimensions | 98 in. W (100-5/8 in. across the side nailing flanges) x 48-1/4 in. H (base to the top of the fireboard nailing flange) x 20-1/8 in. D (spec sheet 901060-00, top, front and side views) |
| Framing dimensions | 98-1/4 in. W x 48-1/2 in. H x 19-1/2 in. D one-sided; 18-1/2 in. deep see-through (manual p.12) |
| Viewing area | 80-5/8 in. W x 15-5/8 in. H glass (spec sheet 901060-00, front view) |
| Clearances to combustibles | Back and sides 1 in. to the outer wrapper, 0 in. at spacers; top of fireboard nailing flange 0 in.; floor 0 in.; 84 in. minimum from the unit bottom to the ceiling; 36 in. in front of the viewing area; vent pipe 1 in. around vertical runs, 3 in. above and 1 in. at the sides and bottom of horizontal runs; combustible side walls 8-1/4 in. from the opening for up to a 12 in. projection, or 14 in. for any projection (manual Table 1 p.11; Fig. 41 p.34) |
| Drawing dimensions (as lettered on Superior's drawing) | A 98 in (overall width, top view) · B 49 in (side to vent centre, top view) · C 80-5/8 in (glass width) · D 85-1/2 in (front view, between the inner edges of the side panels) · E 100-5/8 in (width across the side nailing flanges) (manual Fig. 11, p.16; spec sheet 901060-00) |
| Input, natural gas (max / min) | 50,000 / 35,000 BTU/hr |
| Input, propane after conversion (max / min) | 47,000 / 35,250 BTU/hr |
| Efficiency | P4 55.4% NG / 63.1% LP; AFUE 51.1% NG / 56.7% LP |
| Minimum base-to-ceiling height | 84 in. |
| Ignition | SIT Proflame 2 electronic ignition, selectable IPI/CPI, battery backup (4 AA) |
| Gas inlet | 1/2 in. minimum; supply NG 5.5-10.5 in. WC (recommended 5.5-7.0), LP 11-13 in. WC |
| Manifold pressure | NG 1.6 low / 3.5 high in. WC; LP 6.4 low / 10.0 high in. WC |
| Orifice | #29 (.136") NG / #46 (.081") LP |
| Electrical | 120 VAC, 60 Hz, unswitched, grounded |
| Venting | Superior 6DVL 6 x 9 in. direct vent; optional power vent PVK-PF2-SV4.5 |
| Blower | Factory installed (two blower assemblies (F3866)), six speeds |
| Media included | 5 x 5 lb platinum crushed glass |
| Unit weight | 655 lb (297 kg) (spec sheet 901060-00 Rev. G) |
| Certification | ANSI Z21.88/CSA 2.33, CSA 2.17; CSA P.4.1 |
Dimensions and clearances
- Framing (one-sided): 98-1/4 in. wide x 48-1/2 in. high x 19-1/2 in. deep; see-through framing depth 18-1/2 in. (manual p.12).
- Minimum height from the fireplace base to the ceiling: 84 in. (p.12).
- Clearances to combustibles: back and sides 1 in. to the outer wrapper, spacers 0 in., top nailing flange 0 in., floor 0 in. (p.11).
- Keep furniture and combustibles at least 36 in. from the front of the viewing area (p.11).
- Vent pipe clearance: 1 in. on all sides of vertical runs; 3 in. above and 1 in. at the sides and bottom of horizontal runs (pp.11, 18).
- Combustible side walls: at 14 in. from the opening a side wall can project any distance; at 8-1/4 in. it can project up to 12 in. (p.34).
- TV above the fireplace: IHP guidance is at least 12 in. above the opening on a flush wall and 18 in. for a recessed TV (p.13).
- Corner framing (manual Fig. 10): 98-1/4, 135-7/8, 96-1/8 in. (p.16).
What's included
- Fireplace with burner, black porcelain liner and SIT Proflame 2 electronic control system
- Ceramic glass with protective barrier screen
- Factory-installed six-speed blower
- Floor (accent) lighting
- 5 x 5 lb bags of platinum crushed glass media
- Proflame multi-function remote with receiver/battery holder (4 AA)
Required (sold separately)
- Superior 6DVL 6"x9" direct vent system: pipe, elbows and a horizontal (6DVLHT) or vertical (6DVLVT) termination, with roof flashing and firestops as the route requires
- Or the optional power vent system: PVK-PF2-SV4.5 kit with the 6DVL4.5PVA power vent adapter
- Indoor see-through installs: see-through conversion kit STK-LIN84 (F4412)
- Propane installs: conversion kit GCK-SM-6084NP (F4417) and an external LP regulator (not supplied)
- 120 VAC unswitched electrical supply and gas supply line (by the installer)
Optional accessories
- HeatFlo convection kit HTFLO-LIN84 (F4409)
- Reflective black glass liner kit, 5-piece CGLK-BLK-LIN84 (F4404) (not for see-through)
- Black linear trim kit TRMK-BLK-LIN84 (F4407)
- High-definition driftwood log set DRFTWD-LOG84 (F4401) (not with the see-through kit)
- Crushed glass, 5 lb bags (order 5): reflective black CRSHGL-RBLK, reflective blue CRSHGL-RBLU, platinum CRSHGL-P
- Large glass, 5 lb bags (order 25 lb): Onyx GLO-BLACK, Diamond GLO-CRYSTAL, Sapphire GLO-SAPPHIRE
- Driftwood and rock media kit DRFTWDROCK-KIT; river rock kit RIVROCK-25PK
- Touch-up paint: firebox interior and powder-coat exterior
Product video
Official Superior burn videos for the DRL6000 Series (shown on the 48-inch model):
Installation and safety notes
⚠ Important: Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This fireplace must be installed and serviced by a qualified professional following the Superior DRL6000 installation manual (P/N 901077-00 Rev. L, 02/2025).
Product and safety information
- Listed to ANSI Z21.88/CSA 2.33 and CSA 2.17 as a vented gas fireplace heater for the US and Canada (p.8).
- Approved for 0-4,500 ft with standard orifices in Canada; in the US the input is reduced 4% per 1,000 ft above 2,000 ft (pp.10, 25).
- Do not install in a recreational vehicle (p.7). Approved for aftermarket, permanently located manufactured homes (USA only) and mobile homes: cross members must not be cut or weakened, and the fireplace must be grounded to the home's chassis to local codes (pp.1, 10).
- Massachusetts installations must meet 248 CMR, with a CO detector and a T-handle gas shutoff (p.9).
Planning and framing
- Frame the opening to 98-1/4 x 48-1/2 in. with 19-1/2 in. depth (18-1/2 in. see-through); minimum 84 in. from the base to the ceiling (p.12).
- Do not pack insulation or other material around the unit. For cold climates, insulate an outside chase cavity between the studs and under the floor, and seal cracks around the fireplace with non-combustible material, using caulking rated for at least 300°F continuous exposure; do not use loose or blown-in insulation in the cavity around the fireplace (pp.9-11).
- Clearances: 1 in. back and sides to the wrapper, 0 in. at spacers, nailing flange and floor; 36 in. in front of the glass (p.11).
- TV above: 12 in. minimum flush, 18 in. recessed (p.13).
Gas
- Natural gas unit; propane requires conversion kit GCK-SM-6084NP (F4417) (LP back to NG: GCK-SM-6084PN (F4660)) and an external LP regulator with its vent facing down (pp.27, 52).
- Supply pressure: NG 5.5-10.5 in. WC, LP 11-13 in. WC; use at least 1/2 in. black iron, steel or approved tinned copper line (pp.27-28).
- Leak-test with a non-corrosive solution, never a flame; disconnect the valve for tests above 1/2 psig (p.29).
- Air shutter: 1/8 in. open on NG, 1/4 in. on LP (p.33).
Electrical
- Run a 120 VAC, 60 Hz, unswitched, grounded supply to the junction box on the left side (p.32).
- Battery backup (4 AA) keeps the burner working in an outage; the blower and lights need household power (p.40).
Venting
- Use only Superior 6DVL 6 x 9 in. direct vent components; each fireplace needs its own vent (pp.18, 25).
- A 2 ft vertical rise is the minimum before a horizontal run; maximum vertical is 40 ft; combined vertical and horizontal runs may total up to 60 ft, with up to three elbows depending on the configuration; two 45° elbows count as one 90° elbow (Fig. 17A, p.21).
- Horizontal runs slope up 1/4 in. per foot toward the termination; support rigid pipe every 4 ft (p.18).
- Up to two 4 ft flex sections; no flex through ceilings, attics or walls, 6 in. minimum bend radius (pp.21, 24).
- Horizontal termination clearances (Table 2, p.17): 12 in. above grade, a deck or a balcony; 9 in. from a window or door that opens and from a non-mechanical air inlet (12 in. in Canada); 9 in. recommended from a fixed window to prevent condensation (12 in. in Canada); 18 in. below a ventilated soffit within 18 in. horizontally; 12 in. below an unventilated soffit (30 in. below vinyl); 5 in. from an outside corner and 2 in. from an inside corner; 36 in. to each side of a gas meter or regulator (within 15 ft above it) and from a regulator vent outlet; 36 in. above a mechanical air inlet within 10 ft (72 in. in Canada); 84 in. above a public sidewalk or driveway; 12 in. under a veranda, porch, deck or balcony that is open on at least two sides.
- Vertical termination height above the roof (Table 3, p.23): 1 ft for flat to 6/12, 1.25 ft to 7/12, 1.5 ft to 8/12, 2 ft to 9/12, 2.5 ft to 10/12, 3.25 ft to 11/12, 4 ft to 12/12, 5 ft to 14/12, 6 ft to 16/12, 7 ft to 18/12, 7.5 ft to 20/12 and 8 ft to 21/12.
- Do not recess or seal the termination (pp.18, 20).
- Power vent: PVK-PF2-SV4.5 with the 6DVL4.5PVA adapter and SV4.5/SF4.5 pipe (p.25, p.59).
Final installation: glass, media and lighting
- Spread the 5 bags of crushed glass in a single layer over the burner; never cover the pilot shield or substitute other media (p.31).
- The barrier screen must be in place; never run the fireplace with the glass removed, cracked or broken (pp.6, 30).
- Reflective glass liner panels and driftwood logs are not compatible with the see-through kit (pp.31, 59).
- See-through installs: the blowers must be removed or disabled (p.58).
Finishing
- Clean-face design: the factory tile stops protrude 3/4 in. from the unit, and the face is designed for 1/2 in. non-combustible fireboard, which is supplied and must not be substituted. Never install combustible material (wall finish, surround or trim) on, in front of or overlapping any part of the fireplace front face (pp.12, 34).
- Combustible side walls: 14 in. from the opening for any projection, 8-1/4 in. for up to 12 in. (p.34).
First fire and everyday use
- The first lighting takes a few minutes while air purges from the gas line (p.32).
- Condensation on the glass at start-up is normal and clears in about 10-20 minutes (p.8).
- Flame color settles during the first 30 minutes; the installer can adjust the air shutter (p.33).
- The glass and surrounding surfaces get very hot: supervise children and pets and keep them away (pp.2-3, 6).
- Know the signs of carbon monoxide (headache, dizziness, nausea); if they appear, get fresh air and have the fireplace serviced (p.7).
- Have the fireplace inspected annually by a qualified service technician (pp.4, 50).
Accessories named in the manual
- See-through kit STK-LIN84 (F4412), HeatFlo HTFLO-LIN84 (F4409), glass liner CGLK-BLK-LIN84 (F4404), trim TRMK-BLK-LIN84 (F4407), driftwood logs DRFTWD-LOG84 (F4401), glass and rock media, power vent kit PVK-PF2-SV4.5 (pp.58-59).
Building code information
- Install to local codes or, where none apply, the current National Fuel Gas Code, ANSI Z223.1/NFPA 54 (pp.8, 10).
- In Canada: CSA B149.1 Natural Gas and Propane Installation Code (p.8).
- Electrical: National Electrical Code, ANSI/NFPA 70, or CSA C22.1 Canadian Electrical Code in Canada (p.7).
- Massachusetts: 248 CMR 4.00-8.00, with CO detection to NFPA 720 / UL 2034 (p.9).
Warranty
- Coverage: Innovative Hearth Products Superior Brand Gas Fireplaces, Stoves and Inserts 20 Year Limited Warranty (P/N 900223-00 Rev. C), printed in the installation manual, pp.61-62.
- Product body, firebox and barrier: 20 years. Ceramic glass: 20 years against thermal breakage only.
- Burner, gas components and gaskets: 1 year. Logs: 1 year, thermal breakage only. Tempered glass: 1 year.
- Optional blowers and remote controls: 1 year. Optional glass doors: 90 days. Parts not otherwise listed: 90 days.
- Labor: paid at IHP's prevailing rates during each component's warranty period, up to five years.
- Vent components, trim and paint are not covered by the 20-year term.
- Who is covered: the original owner only (not transferable); the product must be bought from an IHP-listed supplier, with proof of purchase.
- Conditions: installed in the US or Canada by an IHP-approved licensed contractor, to code, and operated and maintained per the instructions. Coverage starts on the purchase date (new construction: first occupancy or six months after sale, whichever is earlier, and no later than 24 months after shipment).
- Exclusions: normal wear, accidents, fire, flood or acts of God; abuse, misuse or alteration; burning solid fuel; improper maintenance; faulty installation; draft problems from HVAC or vent configuration; utility costs.
- How to claim: contact the dealer or distributor you bought from; if they cannot be found, notify IHP in writing within 90 days of the failure.
Downloads
- Installation and Operation Manual (DRL6000 60/72/84, P/N 901077-00)
- Specification Sheet (DRL4000/6000 60-72-84)
- DRL6000 Brochure
- DRL6000 Smart Sheet
- DRL6000 See-Through Smart Sheet
- Power Vent Kit PVK-PF2-SV4.5 Instructions
- HeatFlo Kit Instructions (60/72/84)
California Proposition 65
WARNING: This product can expose you to chemicals including carbon black, which is known to the State of California to cause cancer, and carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Frequently asked questions — DRL6084TEN
What size framing does the DRL6084TEN need?
Frame the opening 98-1/4 in. wide x 48-1/2 in. high x 19-1/2 in. deep for a one-sided install, or 18-1/2 in. deep with the see-through kit, with at least 84 in. from the fireplace base to the ceiling. Clearances are 1 in. at the back and sides to the outer wrapper and 0 in. at the spacers, nailing flange and floor.
What venting does it use, and how far can it run?
Superior 6DVL 6 x 9 in. direct vent pipe, horizontally through a wall or vertically through the roof. It needs at least a 2 ft vertical rise, allows up to 40 ft vertical and up to 60 ft of combined vertical and horizontal run, and up to two 4 ft flex sections. Where a standard route will not work, the PVK-PF2-SV4.5 power vent with the 6DVL4.5PVA adapter allows down-and-out runs.
Can it be converted to propane?
Yes. It ships for natural gas and converts with Superior kit GCK-SM-6084NP (F4417) plus an external LP regulator. On propane it runs 47,000 BTU/hr high and 35,250 BTU/hr low.
Does it work in a power outage?
Yes. Four AA batteries keep the burner lighting and running without household power. The blower and floor lights need 120 VAC power.
Can a TV go above it?
IHP's guidance is at least 12 in. above the opening on a flush wall, or 18 in. for a recessed TV. The optional HeatFlo kit HTFLO-LIN84 sends heat out through vents above the fireplace to keep the wall above cooler.
What's the warranty?
Superior's 20-year limited warranty covers the product body, firebox and barrier, and the ceramic glass against thermal breakage. The burner, gas components and gaskets are covered for 1 year, and labor is paid at IHP's rates during each component's term, up to five years. Coverage is for the original owner.
Loading component details…
Add to cart to see your price.

