Product overview
The Superior DRL4060TEN-B is the 60-inch model in the DRL4000 Series, a clean-face linear direct vent gas fireplace made by Innovative Hearth Products. It brings the long, low ribbon of flame that defines a modern fireplace to contemporary and transitional rooms at a lower entry price than the fully equipped DRL6000, and it suits buyers who want a sleek linear look and like to choose only the extras they need.
The design is wide and uncluttered. An expansive ceramic glass opening gives an exceptional view of gently dancing flames rising through reflective black crushed glass, set against a black painted interior. You can personalize it with reflective blue or platinum crushed glass, large Onyx, Diamond or Sapphire glass, a five-piece reflective black glass liner, a high-definition driftwood log set or river rock, and a black linear trim kit.
Input is 40,000 BTU/hr at the high setting on natural gas, turning down to 28,000 BTU/hr, and the fireplace is field-convertible to propane with the Superior conversion kit. Add the optional two-piece heat-circulating blower to move warm air into the room, or the optional HeatFlo kit to send heat out through vents above the fireplace so art or a TV can hang above it with less heat reaching the wall.
Electronic ignition runs on household power, and a four-AA battery backup keeps the fire lighting during a power outage. A selectable continuous pilot (CPI) helps in cold weather and reduces glass condensation, while the intermittent pilot (IPI) setting saves fuel in warmer months. Add the optional Superior remote kit for on/off and thermostat control from across the room, or wire a wall switch or thermostat.
Installation is flexible. The fireplace vents through Superior 6DVL 6"x9" direct vent pipe, horizontally through a wall or vertically through the roof, with up to 40 ft of vertical rise. Its clean-face design with integrated tile stops makes finishing easy, and an indoor see-through conversion kit lets the same fireplace be enjoyed from two rooms. Compared with the DRL6000, the DRL4000 shares the same sizes, framing and venting but makes the blower and remote optional and uses a black painted interior instead of a porcelain liner with floor lighting.
Key features
- Linear configured models: available in 48, 60, 72 and 84-inch sizes; this is the 60-inch model.
- Indoor see-through option: the see-through conversion kit allows viewing from two living spaces (blower use is not compatible with see-through).
- HeatFlo kit option: directs heat above heat-sensitive wall hangings.
- Electronic ignition with battery backup: continued operation in the event of a power outage (blower does not run on battery).
- Selectable IPI/CPI pilot: intermittent pilot for savings or a continuous pilot for cold-climate use.
- Clean-face design: integrated tile stops for easy finishing.
- Ceramic glass with protective screen: optimum heat transfer, with a barrier screen that complies with ANSI Z21.88 barrier requirements.
- Black painted interior: standard, with an optional five-piece reflective black glass liner.
- Reflective black crushed glass included: 3 five-pound bags supplied, with several optional colors to customize the look.
- Optional blower: two-piece, heat-activated blower kit FBK-LIN-B (one-sided installations only).
- Optional remote control: Superior remote kit OTRK-LIN for on/off and thermostat operation.
- Superior 6DVL direct venting: horizontal or vertical termination, up to 40 ft vertical.
- Natural gas, field-convertible to propane: with the Superior conversion kit.
- Certified: listed to ANSI Z21.88/CSA 2.33 and CSA 2.17 as a vented gas fireplace heater.
- 20-year limited warranty: on the product body, firebox and barrier.
Specifications
| Model | DRL4060TEN-B (natural gas, electronic ignition) |
|---|---|
| Series | Superior DRL4000 linear direct vent |
| Type | Direct vent gas fireplace, clean-face, front view (see-through with kit) |
| Unit dimensions | 74 in. W (76-5/8 in. across the side nailing flanges) x 48-1/4 in. H (base to the top of the fireboard nailing flange) x 20-1/8 in. D (spec sheet 901060-00, top, front and side views) |
| Framing dimensions | 74-1/4 in. W x 48-1/2 in. H x 19-1/2 in. D one-sided; 18-1/2 in. deep see-through (manual p.12) |
| Viewing area | 56-5/8 in. W x 15-5/8 in. H glass (spec sheet 901060-00, front view) |
| Clearances to combustibles | Back and sides 1 in. to the outer wrapper, 0 in. at spacers; top of fireboard nailing flange 0 in.; floor 0 in.; 84 in. minimum from the unit bottom to the ceiling; 36 in. in front of the viewing area; vent pipe 1 in. around vertical runs, 3 in. above and 1 in. at the sides and bottom of horizontal runs; combustible side walls 8-1/4 in. from the opening for up to a 12 in. projection, or 14 in. for any projection (manual Table 1 p.11; Fig. 41 p.34) |
| Drawing dimensions (as lettered on Superior's drawing) | A 74 in (overall width, top view) · B 37 in (side to vent centre, top view) · C 56-5/8 in (glass width) · D 61-1/2 in (front view, between the inner edges of the side panels) · E 76-5/8 in (width across the side nailing flanges) (manual Fig. 11, p.16; spec sheet 901060-00) |
| Input, natural gas (max / min) | 40,000 / 28,000 BTU/hr |
| Input, propane after conversion (max / min) | 40,000 / 30,000 BTU/hr |
| Efficiency | P4 55.1% NG / 54.0% LP; AFUE 52.6% NG / 52.6% LP |
| Minimum base-to-ceiling height | 84 in. |
| Ignition | SIT Proflame electronic ignition (PF1), selectable IPI/CPI, battery backup (4 AA) |
| Gas supply | NG 5.5-10.5 in. WC (recommended 5.5-7.0); LP 11-13 in. WC |
| Manifold pressure | NG 1.6 low / 3.5 high in. WC; LP 6.4 low / 10.0 high in. WC |
| Orifice | #31 (.120") NG / #49 (.073") LP |
| Electrical | 120 VAC, 60 Hz, unswitched, grounded |
| Venting | Superior 6DVL 6 x 9 in. direct vent only |
| Blower | Optional FBK-LIN-B (not with see-through) |
| Media included | 3 x 5 lb reflective black crushed glass |
| Unit weight | 470 lb (213 kg) (spec sheet 901060-00 Rev. G) |
| Certification | ANSI Z21.88/CSA 2.33, CSA 2.17; efficiency to CSA P.4.1 |
Dimensions and clearances
- Framing (one-sided): 74-1/4 in. wide x 48-1/2 in. high x 19-1/2 in. deep; see-through framing depth 18-1/2 in. (manual p.12).
- Minimum height from the fireplace base to the ceiling, and minimum enclosure height: 84 in. (pp.11-12).
- Clearances to combustibles: back 1 in., sides 1 in., spacers 0 in., top nailing flange 0 in., floor 0 in. (p.11).
- Keep furniture and combustibles at least 36 in. from the front of the viewing area (p.11).
- Vent pipe clearance: 1 in. around vertical runs; 3 in. above and 1 in. at the sides and bottom of horizontal runs (p.11).
- TV above the fireplace: IHP recommends at least 12 in. above the opening on a flush wall and 18 in. for a recessed TV, or add the HeatFlo kit (pp.13-15).
What's included
- Fireplace with burner, black painted interior and SIT Proflame electronic control system
- Ceramic glass with protective barrier screen
- 3 x 5 lb bags of reflective black crushed glass media
- Battery holder with 4 AA batteries for backup operation
- 15 ft of two-conductor wire for an optional wall switch or thermostat
Required (sold separately)
- Superior 6DVL 6"x9" direct vent system: pipe, elbows and a horizontal (6DVLHT) or vertical (6DVLVT) termination, plus roof flashing (6DVLFF, 6DVLF5 or 6DVLF12) and firestops as the route requires
- Indoor see-through installs: see-through conversion kit STK-LIN60-B (F4410)
- Propane installs: conversion kit GCK-M-4060BNP (F4414) and an external LP regulator (not supplied)
- 120 VAC unswitched electrical supply and gas supply line (by the installer)
Optional accessories
- Blower kit FBK-LIN-B (F4580), two-piece, heat-activated (not for see-through)
- Remote kit OTRK-LIN (F3835), on/off and thermostat
- HeatFlo convection kit HTFLO-LIN60 (F3780)
- Reflective black glass liner kit, 5-piece CGLK-BLK-LIN60 (F3776) (not for see-through)
- Black linear trim kit TRMK-BLK-LIN60 (F3778)
- High-definition driftwood log set DRFTWD-LOG60 (F3774)
- Crushed glass, 5 lb bags (order 3): reflective black CRSHGL-RBLK, reflective blue CRSHGL-RBLU, platinum CRSHGL-P
- Large glass, 5 lb bags (order 3): Onyx GLO-BLACK, Diamond GLO-CRYSTAL, Sapphire GLO-SAPPHIRE
- River rock kit RIVROCK-25PK; driftwood and rock media kit DRFTWDROCK-KIT
- Touch-up paint: firebox interior and powder-coat exterior SCTPSAB
Product video
Official Superior videos for the DRL4000 Series:
Installation and safety notes
⚠ Important: Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This fireplace must be installed and serviced by a qualified professional following the Superior DRL4000 installation manual (P/N 901080-00 Rev. K).
Product and safety information
- Listed to ANSI Z21.88/CSA 2.33 and CSA 2.17 as a vented gas fireplace heater for the US and Canada (p.8).
- High altitude: approved for installation from 0 to 4,500 ft (0-1,372 m) above sea level (p.10). In the USA, input is reduced 4% for each 1,000 ft above sea level; in Canada no input reduction is needed up to 4,500 ft (1,370 m), and any high-altitude conversion is carried out by a manufacturer's authorized representative to CSA 2.17 (pp.10, 25).
- Manufactured homes: approved for aftermarket, permanently located manufactured homes (USA only). Cross members must not be cut or weakened, the floor, wall and ceiling/roof structure must stay intact, and the fireplace must be grounded to the home's chassis to local codes (p.10).
- Massachusetts installations must meet 248 CMR, including CO detection (p.9).
- Cold-climate installs: insulate an outside chase cavity between the studs and under the floor, and seal cracks around the fireplace with non-combustible material, using caulking rated for at least 300°F continuous exposure. Do not use loose or blown-in insulation in the cavity around the fireplace, and do not insulate the space between the fireplace and the area above it (pp.9-11).
Planning and framing
- Frame the opening to 74-1/4 x 48-1/2 in. with 19-1/2 in. depth (18-1/2 in. see-through); minimum 84 in. from the base to the ceiling (p.12).
- Clearances: 1 in. back and sides, 0 in. at spacers, nailing flange and floor; 36 in. in front of the glass (p.11).
- Framing closer than the minimum clearances must be non-combustible (p.11).
- TV above: 12 in. minimum flush, 18 in. recessed (p.13).
Gas
- Natural gas unit; propane requires conversion kit GCK-M-4060BNP (F4414) (LP back to NG: GCK-M-4060BPN (F4582)) and an external LP regulator (pp.27-28, 47).
- Supply pressure at the connection: NG 5.5-10.5 in. WC (recommended 5.5-7.0), LP 11-14 in. WC from the external regulator (pp.27-28).
- Leak-test with a non-corrosive solution, never a flame; pressures above 1/2 psig can damage the regulator, so isolate the fireplace during line tests (p.29).
- Air shutter: 1/8 in. open on NG, 1/4 in. on LP (p.33).
Electrical
- Run a 120 VAC, 60 Hz, single-phase, unswitched, grounded supply to the junction box (pp.32-33).
- Optional wall switch, thermostat or remote connect on the low-voltage circuit; 15 ft of two-conductor wire is supplied (p.32).
- Battery backup (4 AA) keeps the fireplace lighting in an outage; the blower does not run on battery (p.38).
Venting
- Use only Superior 6DVL 6 x 9 in. direct vent components (p.18, Table 4 p.25); the manual lists no power vent option for this model.
- Minimum vertical rise 2 ft; maximum vertical 40 ft; up to 60 ft combined vertical and horizontal, with up to 3 elbows depending on the configuration; two 45° elbows count as one 90° elbow (Fig. 17A, p.21).
- Slope horizontal runs 1/4 in. per foot toward the termination (p.18).
- Up to two 4 ft flex sections (6DVL48F); other flex combinations are limited to a 40 ft total run (p.21).
- Horizontal termination clearances (Table 2, p.17): 12 in. above grade, a deck or a balcony; 9 in. from a window or door that opens and from a non-mechanical air inlet (12 in. in Canada); 9 in. recommended from a fixed window to prevent condensation (12 in. in Canada); 18 in. below a ventilated soffit within 18 in. horizontally; 12 in. below an unventilated soffit (30 in. below vinyl); 5 in. from an outside corner and 2 in. from an inside corner; 36 in. to each side of a gas meter or regulator (within 15 ft above it) and from a regulator vent outlet; 36 in. above a mechanical air inlet within 10 ft (72 in. in Canada); 84 in. above a public sidewalk or driveway; 12 in. under a veranda, porch, deck or balcony that is open on at least two sides.
- Vertical termination height above the roof (Table 3, p.23): 1 ft for flat to 6/12, 1.25 ft to 7/12, 1.5 ft to 8/12, 2 ft to 9/12, 2.5 ft to 10/12, 3.25 ft to 11/12, 4 ft to 12/12, 5 ft to 14/12, 6 ft to 16/12, 7 ft to 18/12, 7.5 ft to 20/12 and 8 ft to 21/12.
- Damaged, modified or non-approved vent parts void the warranty (p.18).
Final installation: glass and media
- Spread the 3 bags of crushed glass over the burner as shown; never substitute other media (p.31).
- The barrier screen must be in place; never run the fireplace with the glass removed, cracked or broken.
- Reflective glass liner panels and the blower are not compatible with the see-through kit (pp.12, 31, 54).
- See-through installs: any blower must be removed or disabled (p.12).
Finishing
- Clean-face design: the factory tile stops protrude 3/4 in. from the unit for standard tile, and 1/2 in. wall sheathing aligns with the factory non-combustible material. The supplied non-combustible fireboard goes at the bottom, sides and top of the fireplace face and must not be substituted; no combustible wall finish, surround or trim may be installed on, in front of or overlapping the face, and any framing closer than the minimum clearances must be non-combustible (pp.34-35).
First fire and everyday use
- Lighting: switch off, wait five minutes and check for gas smell before lighting; then use the remote, switch or thermostat (p.38).
- CPI (continuous pilot) reduces glass condensation and helps in cold weather; IPI saves fuel in warm months (p.38).
- The glass and surrounding surfaces get very hot: supervise children and pets and keep them away.
- Keep furniture and combustibles 36 in. from the front of the fireplace (p.11).
- Have a qualified service technician inspect the fireplace and venting system before first use and at least once a year, before the burning season: valve and gas piping, pilot and flame sensor, flame pattern and the vent. Clean the glass two or three times per heating season, only when it is cool.
Accessories named in the manual
- See-through kit STK-LIN60-B (F4410), blower FBK-LIN-B, remote OTRK-LIN, HeatFlo HTFLO-LIN60 (F3780), glass liner CGLK-BLK-LIN60 (F3776), trim TRMK-BLK-LIN60 (F3778), driftwood logs DRFTWD-LOG60 (F3774), glass, large glass and rock media, touch-up paint (pp.53-54).
Building code information
- Install to local codes or, where none apply, the current National Fuel Gas Code, ANSI Z223.1/NFPA 54 (p.8).
- In Canada: CSA B149.1 Natural Gas and Propane Installation Code (p.8).
- Electrical: National Electrical Code, ANSI/NFPA 70, or CSA C22.1 Canadian Electrical Code in Canada.
- Massachusetts: 248 CMR 4.00-8.00, with CO detection to NFPA 720 / UL 2034 (p.9).
Warranty
- Coverage: Innovative Hearth Products Superior Brand Gas Fireplaces, Stoves and Inserts Limited Warranty (P/N 900223-00 Rev. C), printed in the installation manual, pp.55-56.
- Product body, firebox and barrier: 20 years. Ceramic glass: 20 years against thermal breakage only.
- Burner, gas components, gaskets and tempered glass: 1 year. Logs: 1 year, thermal breakage only.
- Optional blowers and remote controls: 1 year. Optional glass doors: 90 days. Parts not otherwise listed: 90 days.
- Labor: paid at IHP's prevailing rates during each component's warranty period, up to five years.
- Vent components, trim and paint are not covered by the 20-year term.
- Who is covered: the original owner only (not transferable); bought from an IHP-listed supplier, with proof of purchase.
- Conditions: installed in the US or Canada by an IHP-approved licensed contractor, and operated and maintained per the instructions. Coverage starts on the purchase date (new construction: first occupancy or six months after sale, whichever is earlier, and no later than 24 months after shipment).
- Exclusions: normal wear, accidents, misuse, burning wood or coal, lack of maintenance, faulty installation, and draft problems caused by HVAC or the vent configuration.
- Claims: notify in writing within 90 days of the failure. Replacement parts are offered, when practicable, for 10 years after the last manufacture date.
Downloads
- Installation and Operation Manual (DRL4000 60/72/84, P/N 901080-00)
- Specification Sheet (DRL4000/6000 60-72-84)
- DRL4000 Brochure
- DRL4000 Smart Sheet
- DRL4000 See-Through Smart Sheet
- See-Through Kit Instructions
- HeatFlo Kit Instructions (60/72/84)
California Proposition 65
WARNING: This product can expose you to chemicals including carbon black, which is known to the State of California to cause cancer, and carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Frequently asked questions — DRL4060TEN-B
What size framing does the DRL4060TEN-B need?
Frame the opening 74-1/4 in. wide x 48-1/2 in. high x 19-1/2 in. deep for a one-sided install, or 18-1/2 in. deep with the see-through kit, with at least 84 in. from the fireplace base to the ceiling. Clearances are 1 in. at the back and sides to the outer wrapper and 0 in. at the spacers, nailing flange and floor.
What venting does it use, and how far can it run?
Superior 6DVL 6 x 9 in. direct vent pipe only, horizontally through a wall or vertically through the roof. It needs at least a 2 ft vertical rise, allows up to 40 ft vertical and up to 60 ft of combined vertical and horizontal run, with up to 3 elbows depending on the layout. The manual lists no power vent option for this model.
Can it be converted to propane?
Yes. It ships for natural gas and converts with Superior kit GCK-M-4060BNP (F4414) plus an external LP regulator.
Does it work in a power outage?
Yes. A four-AA battery backup keeps the fireplace lighting during an outage. The optional blower does not run on battery.
Is a remote included?
No. The DRL4060TEN-B runs from an optional wall switch, thermostat or remote on its low-voltage circuit, and 15 ft of two-conductor wire is supplied. Superior's optional remote kit OTRK-LIN (F3835) adds on/off and thermostat control.
What's the warranty?
Superior's 20-year limited warranty covers the product body, firebox and barrier, and the ceramic glass against thermal breakage. The burner, gas components and gaskets are covered for 1 year, and labor is paid at IHP's rates during each component's term, up to five years. Coverage is for the original owner.