The Superior DRL3555 is the 55-inch model in the DRL3500 Series, a clean-face linear direct vent gas fireplace from Innovative Hearth Products with a low-profile design for contemporary and transitional spaces. It shares its features with the 35 and 45-inch models, so choose by wall width; compared with the DRL2000 Series it adds a factory-installed blower and a remote as standard.
A wide tempered-glass opening with a protective screen shows a ribbon of flame rising through platinum crushed glass over a black painted interior, with six-setting floor lighting for mood with or without fire. Personalize it with a porcelain liner, other glass colors, river rock or driftwood logs, and finish with a decorative surround or tile up to the integrated tile stops.
It runs from 28,000 down to 19,000 BTU/hr on natural gas (propane 27,000 to 21,000) and a six-speed blower moves the warmth into the room. The optional HeatFlo kit HTFLO-DV55 vents heat above the fireplace for art or a TV. Four AA batteries keep the fire lighting in a power outage. It vents with Superior SV4.5 or SF4.5 pipe, horizontally or vertically up to 60 ft, and is approved for bedrooms and US manufactured homes.
Key features
- 55-inch linear model: the DRL3500 Series comes in 35, 45 and 55-inch widths.
- Clean-face design: integrated tile stops for easy finishing; optional black matte or stainless decorative surround.
- Tempered glass with protective screen: meets ANSI Z21.88 barrier requirements.
- Platinum crushed glass and black painted interior: standard, with an optional black porcelain liner, other glass colors, river rock or driftwood logs.
- Factory-installed blower and floor lighting: six blower speeds to fine-tune your heat and six lighting settings.
- Multi-function remote included: on/off, thermostat, flame height, blower and lighting.
- Electronic ignition with battery backup: continued operation in the event of a power outage; outstanding heating efficiency (62.4% NG / 63.4% LP P.4.1).
- HeatFlo kit option: directs heat above heat-sensitive wall hangings (45 and 55-inch only); HTFLO-DV55 for this size.
- Flexible venting and fuel: Superior SV4.5 / SF4.5 direct venting, rigid or flex, horizontal or vertical; natural gas or propane, field-convertible with GCK-S-L3555NP / GCK-S-L3555PN.
- Approved, certified and warranted: bedrooms and manufactured homes (US) (manual pp.8, 12); ANSI Z21.88/CSA 2.33 and CAN/CGA-2.17 vented gas fireplace heater (PFS TECO report F19-008); 20-year limited warranty on the product body, firebox and barrier.
Specifications
| Model | DRL3555TEN (natural gas) / DRL3555TEP (propane), electronic ignition; catalog F4237 / F4904 |
|---|---|
| Series | Superior DRL3500 linear direct vent |
| Type | Clean-face linear direct vent gas fireplace, front view |
| Unit dimensions | 55-1/2" W x 24-3/4" H x 17" D overall (dimensions E, A and J, manual Table 11, p.18) |
| Framing dimensions | 55-7/8" W x 29" H x 18" D, framed with 2x4 or larger lumber (manual framing Table 10, p.18). Framing values do not apply to flex-vent kits, which have their own requirements. |
| Viewing area | 50" W x 16-3/4" H glass viewing area (dimensions D and C, manual Table 11, p.18) |
| Clearances to combustibles | Back and sides 1/2" to the wrapper, 0" to the spacers; top 0" to the standoffs; floor 0" (6" with the optional surround); 52" minimum from the fireplace base to the ceiling; vent pipe 3" above and 1" at the sides and bottom; 36" front service clearance; shelf height with a top vent and one 90-degree elbow 62" (Secure Vent rigid) or 64" (Secure Flex) (manual Tables 8-9, p.15) |
| Input, natural gas (high / low) | 28,000 / 19,000 BTU/hr |
| Input, propane (high / low) | 27,000 / 21,000 BTU/hr |
| Efficiency (P.4.1) | 62.4% NG / 63.4% LP (AFUE 67.7% / 61%) |
| Ignition | SIT Proflame electronic intermittent pilot (IPI), battery backup (4 AA) |
| Gas supply | NG 5.0-10.5 in. WC; LP 11.0-13.0 in. WC |
| Manifold pressure | NG 3.5 in. WC; LP 10.0 in. WC |
| Orifice (0-4,500 ft) | #40 (0.098 in.) NG; #53 (0.0595 in.) LP |
| Electrical | 120 VAC, 60 Hz, single phase |
| Venting | Superior SV4.5 / SF4.5 4-1/2 x 7-1/2 in. direct vent (or Z-Flex Model GA) |
| Blower | Factory installed, six speeds |
| Lighting | Floor lighting, six settings |
| Remote | Multi-function remote included |
| Media included | Platinum crushed glass (7.5 lb installed) |
| Shipping weight | 143 lb (manual replacement parts list) |
| Certification | ANSI Z21.88/CSA 2.33, CAN/CGA-2.17 (PFS TECO report F19-008) |
| Warranty | 20-year limited (body, firebox and barrier) |
Dimensions and clearances
- Unit: 55-1/2 in. wide x 24-3/4 in. high x 17 in. deep overall; glass viewing area 50 in. wide x 16-3/4 in. high (manual Table 11, p.18).
- Framing: 55-7/8 in. wide x 29 in. high x 18 in. deep (Superior DRL3500 page; manual framing Table 10, p.18), framed with 2x4 or larger lumber. Framing values do not apply to flex-vent kits, which have their own requirements (p.18).
- Clearances to combustibles: back and sides 1/2 in. to the wrapper and 0 in. to the spacers; top 0 in. to the standoffs; floor 0 in. (6 in. with the optional surround); 52 in. minimum from the fireplace base to the ceiling; 36 in. front service clearance (Table 8, p.15).
- Vent pipe: 3 in. above any horizontal or inclined vent component, 1 in. at the sides and bottom (Table 8, p.15).
- Shelf height with a top vent and one 90-degree elbow: 62 in. with Secure Vent rigid, 64 in. with Secure Flex (Table 9, p.15).
- The fireplace is approved for zero clearance to the spacers but cannot be recessed; a side wall flush with one side must not extend past the front edge (p.15).
- Mantels: a combustible mantel 2 in. deep must be at least 6 in. above the hood, and each extra 2 in. of depth needs 2 in. more height, up to 12 in. deep at 16 in. above (Fig. 5A); with the HeatFlo kit the chart runs from 2 in. deep at 2 in. above to 12 in. deep at 12 in. above (Fig. 5B, p.16); non-combustible mantels may be at any height, but nothing may hang below the hood. Combustible side walls need 6 in. minimum side clearance (Fig. 5C).
- TV above: flush wall - at least 12 in. above the opening, 3 in. below the vent opening, vent opening 4 in. below the ceiling; recessed pocket - 18 in. above the opening, 3-1/2 in. maximum depth; follow the TV maker's temperature limits (Figs. 6/6A, pp.19-20).
- HeatFlo installs: framed opening 55-7/8 in. wide x 18 in. high above the fireplace, 3-1/2 in. maximum recess (Table 12, p.19).
What's included
- Fireplace with burner, SIT Proflame electronic controls, factory-installed blower and floor lighting
- Tempered glass with protective barrier screen (F4250)
- Platinum crushed glass media (7.5 lb)
- Multi-function remote control
- Non-combustible front fireboard standoff, header shield, wall heat shield
- Two U-shaped vent restrictors and a minimal vent run baffle
- Battery holder for 4 AA backup batteries; 15 ft of two-conductor wire
Required (sold separately)
- Superior SV4.5 / SF4.5 4-1/2"x7-1/2" direct vent system: a horizontal termination (SV4.5HT-2, SV4.5TK90HT2, small-square SV4.5 options, SF4.5HT-2 or an SFKIT flex kit) or a vertical termination (SV4.5GV-1 with roof flashing SV4.5F, SV4.5FA or SV4.5FB, or SFVT30/SFVT45 for flex), plus pipe, elbows and firestops for the route
- Attic insulation shield where the vent passes blown or loose-fill insulation (manual H3907; store SV4.5RSA)
- Wall heat shield extension kit F3694 for walls thicker than 12 in. (installer)
- 120 VAC electrical supply and gas supply line (by the installer)
Optional accessories
- Gas conversion kit: natural gas to propane GCK-S-L3555NP, propane to natural gas GCK-S-L3555PN (Table 26, p.54)
- Decorative surround: black matte DS-BLK-RNCL55 (F4242) or stainless DS-SS-RNCL55 (F4243)
- Black porcelain liner kit PLK-BLK-RNCL55 (F4246)
- Driftwood log set DWLS-RNCL55 (F4442)
- River rock, 25-piece kit RIVROCK-25PK (F3775)
- Crushed glass, 5 lb bags (two bags; use 7.5 lb): reflective black CRSHGL-RBLK, reflective blue CRSHGL-RBLU, platinum CRSHGL-P
- HeatFlo convection kit HTFLO-DV55 (F4453) and HeatFlo flex extension HTFLO-EK-4.5 (F4578, 60 in.)
- Termination guards: SV4.5HGS (deluxe) or SV4.5HGS-1 (small square)
- Touch-up paint: firebox interior SCITPSAB, powder-coat exterior SCTPSAB
Product video
Official Superior videos for the DRL3500 Series:
Installation and safety notes
⚠ Important: Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This fireplace must be installed and serviced by a qualified professional following the Superior installation manual (DRL2000/DRL3500, P/N 900994-00 Rev. N). If you ever smell gas, do not light any appliance or touch electrical switches; leave the building and call your gas supplier from outside.
Safety and your fireplace
- Listed by PFS TECO (report F19-008) to ANSI Z21.88/CSA 2.33 and CAN/CGA-2.17 as a vented gas fireplace heater (pp.6, 8).
- The barrier screen (F4250) must be in place before operating; never run the fireplace with the glass removed, cracked or broken (p.6).
- Never connect to private wellhead gas; doing so voids the warranty (p.6).
- The glass and surrounding surfaces get very hot: supervise children and pets and keep furniture and combustibles away from the front.
Gas pressure and high altitude
- Inlet: NG 5.0-10.5 in. WC, LP 11.0-13.0 in. WC; manifold NG 3.5 in. WC, LP 10.0 in. WC; test ports on the valve (p.9).
- Orifices for 0-4,500 ft: NG #40 (0.098 in.), LP #53 (0.0595 in.) (Table 5, p.10). Above 4,500 ft derate per the gas supplier or local authority; flame size drops about 4% per 1,000 ft (p.10).
- Disconnect the fireplace from the gas line when pressure-testing above 1/2 psi (p.10).
Massachusetts, cold climates and manufactured homes
- Massachusetts: 248 CMR 4.00-8.00 applies - licensed installer, 36 in. maximum flex connector, T-handle shutoff and extra CO detector rules for horizontal vents under 7 ft (p.11).
- Cold climates: follow the manual's cold-climate insulation guidance for exterior walls and chases (p.11).
- Manufactured homes (US only, where local codes allow): ground the fireplace to the chassis and do not weaken structural members (p.12).
Location and vent termination clearances
- Termination clearances (Table 7, p.14), for example: 12 in. above grade, decks or balconies; 9 in. from an opening window or door (10,000-50,000 BTU/hr); 18 in. below a ventilated soffit; 36 in. horizontally from a gas meter or regulator; 84 in. above a public sidewalk or driveway.
- Vertical terminations must clear the roof by the pitch table (Table 6, p.13): 1 ft up to 6/12, rising to 8 ft at 21/12.
- Keep terminations above the expected snow line, away from roof runoff, and fit a guard where people could touch them (pp.33-36).
Minimum clearances to combustibles
- Back and sides 1/2 in. to the wrapper, 0 in. to spacers; top 0 in. to standoffs; floor 0 in. (6 in. with the optional surround); 52 in. base to ceiling; vent 3 in. above and 1 in. at the sides and bottom (Table 8, p.15).
- A fully supported base is required; combustible flooring other than wood needs a metal or wood panel under the fireplace (p.15).
Wall finishes, surrounds and mantels
- Combustible wall finishes and surrounds may not encroach on the fireplace face; non-combustible trim up to 6 in. deep may overlap the face but must not cover the removable glass or block barrier removal (p.16).
- Combustible mantels: 6 in. above the hood at 2 in. deep, up to 16 in. above at 12 in. deep (2 in. to 12 in. above with the HeatFlo kit, Figs. 5A-5B); paint the underside of a combustible mantel with paint rated 175°F or higher. Non-combustible mantels may be at any height (p.16).
Installation: framing, gas and electrical
- Frame the opening (55-7/8 in. wide) with 2x4 or larger lumber and build a solid platform when the fireplace is raised (pp.17-18).
- Fit the top spacers, the non-combustible front fireboard standoff and the header shield; route the gas line and rough in the electrical supply before placing and securing the fireplace (pp.21-23).
- Route a 3-wire, 120 VAC, 60 Hz, single-phase supply to the fireplace junction box; ground per code (pp.8, 41).
Vent system
- Use only Superior Secure Vent SV4.5, Secure Flex SF4.5 or Z-Flex Model GA 4-1/2 x 7-1/2 in. components (UL 1777 / ULC S635); do not mix brands (p.8).
- Straight vertical runs: 6 ft minimum, 60 ft maximum; with two 90-degree elbows up to 25 ft horizontal, with three elbows up to 20 ft horizontal (Tables 17-18, pp.31-32).
- Install the U-shaped restrictor on any run with more than 6 ft of vertical rise, and the minimal vent run part listed for this model in Table 13 (pp.23-24).
- 55-inch models need 1 ft of vertical rise directly off the fireplace before an elbow (p.15).
- Wall terminations: walls up to 9-1/4 in. with the termination kit alone, up to 20 in. with extra sections and a telescopic section (Table 19, p.36); the wall heat shield keeps 1-1/4 in. clearance to the pipe (p.34).
- Support vertical runs every 8 ft and horizontal runs every 5 ft; never join separate sections of concentric flex pipe (pp.29-31).
Remote, interior options and finishing
- Initialize the remote to the receiver before first use (p.46).
- Spread the platinum glass media evenly (7.5 lb maximum for this size); install the optional porcelain liner panels before the media (pp.47, 58-59).
- Reinstall the hood and barrier screen; finishing materials must keep the required clearances and must not block the glass or barrier (pp.49-50).
Operation, burn-in and maintenance
- Follow the burn-in instructions for the first fires and ventilate the room while the finish cures (p.57).
- Four AA batteries keep the ignition working in a power outage; the blower needs household power (p.8).
- Have a qualified technician inspect the burner, controls, glass gasket and vent system at least once a year, following the maintenance schedule (pp.62-64).
Accessories named in the manual
- Surrounds F4242/F4243, porcelain liner F4246, driftwood logs F4442, glass media H8412/H8424/H8413, river rock F3775, touch-up paint F1881/F1882, HeatFlo F4453 with extension F4578, termination guards H5820/87L02/17M52 (pp.52-53, 64-66).
Building code information
- Install to local codes or, where none apply, the current National Fuel Gas Code, ANSI Z223.1/NFPA 54.
- In Canada: CSA B149.1 Natural Gas and Propane Installation Code.
- Electrical: National Electrical Code, ANSI/NFPA 70, or CSA C22.1 Canadian Electrical Code in Canada.
- Propane tank sizing: NFPA 58 Liquefied Petroleum Gas Code.
- Vent listings: UL 1777 and ULC S635 (p.8).
- Massachusetts: 248 CMR 4.00-8.00, with CO detection to NFPA 720 / UL 2034 (pp.10-11).
Warranty
- Coverage: Innovative Hearth Products Superior Brand Gas Fireplaces, Stoves and Inserts Limited Warranty (P/N 900223-00 Rev. C), printed in the installation manual (manual p.75).
- Product body, firebox and barrier: 20 years. Ceramic glass: 20 years against thermal breakage only.
- Burner, gas components and gaskets: 1 year. Tempered glass: 1 year. Logs: 1 year, thermal breakage only.
- Optional blowers and remote controls: 1 year. Optional glass doors: 90 days. Parts not otherwise listed: 90 days.
- Labor: paid at IHP's prevailing rates during each component's warranty period, up to five years.
- Vent components, trim and paint are not covered by the 20-year term.
- Who is covered: the original owner only (not transferable); bought from an IHP-listed supplier, with proof of purchase.
- Conditions: installed in the US or Canada by an IHP-approved licensed contractor to local codes, and operated and maintained per the instructions.
- Exclusions: normal wear; accident, fire or flood; abuse, misuse or alteration; lack of maintenance; faulty installation; burning wood, coal or other solid fuel; draft problems caused by HVAC, the vent configuration or building conditions.
- Claims: contact the selling dealer; if that is not possible, notify IHP in writing within 90 days of the failure. Replacement parts are generally available for 10 years after the last manufacture date.
Downloads
- Installation and Operation Manual (DRL2000/DRL3500, P/N 900994-00)
- Specification Sheet (DRL2000/DRL3500, P/N 900994-01)
- DRL3500 Brochure
- DRL3500 Smart Sheet
- HeatFlo Kit Instructions
- HeatFlo Extension Kit Instructions
California Proposition 65
WARNING: This product can expose you to chemicals including carbon black and carbon monoxide, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Frequently asked questions — DRL3555
What size framing does the DRL3555 need?
Frame the opening 55-7/8 in. wide x 29 in. high x 18 in. deep with 2x4 or larger lumber. The fireplace itself is 55-1/2 in. wide x 24-3/4 in. high x 17 in. deep. These framing values do not apply to flex-vent kits, which have their own requirements.
What venting does it use, and how far can it run?
Superior Secure Vent SV4.5 rigid, Secure Flex SF4.5 or Z-Flex Model GA 4-1/2 x 7-1/2 in. direct vent pipe, through a wall or the roof. Straight vertical runs go from 6 ft up to 60 ft; with two 90-degree elbows it can run up to 25 ft horizontally, or 20 ft with three. 55-inch models need 1 ft of vertical rise directly off the fireplace before an elbow.
Can it be converted between natural gas and propane?
Yes. It ships as DRL3555TEN for natural gas or DRL3555TEP for propane, and converts in the field with kit GCK-S-L3555NP (natural gas to propane) or GCK-S-L3555PN (propane to natural gas).
Does it work in a power outage?
Yes. Four AA batteries keep the electronic ignition and fire working during an outage. The blower and lights need household 120 VAC power.
Can a TV go above it?
Yes. On a flush wall, the TV must be at least 12 in. above the opening and 3 in. below the vent opening, with the vent opening 4 in. below the ceiling. In a recessed pocket, it must be 18 in. above the opening with a 3-1/2 in. maximum depth. The optional HeatFlo kit HTFLO-DV55 sends heat out above the fireplace, away from the TV. Follow the TV maker's temperature limits.
What is the warranty?
20 years on the product body, firebox and barrier, and 20 years on the ceramic glass against thermal breakage only. The burner, gas components, gaskets and tempered glass are covered for 1 year, and optional blowers and remotes for 1 year. Coverage is for the original owner only.