Product overview

The Superior WRT4550 is the 50-inch, largest of the three WRT4500 Series traditional open-hearth wood-burning fireplaces from Innovative Hearth Products, designed for large, custom applications and sharing its design and manual with the 36 and 42-inch models. It gives the crackle, smell and glow of a real wood fire in a factory-built, zero-clearance unit that installs in ordinary wood framing without the weight, cost and construction time of site-built masonry.

The look is pure masonry: a tall 30-inch opening and brick-to-face design leave no interior sheet metal in view, with white refractory in a stacked (WS) or herringbone (WH) pattern ending in an integrated ash lip. The clean face and textured powder-coat exterior take the stone, tile or other non-combustible facing of your choice.

Like any open hearth it is made for ambiance and supplemental heat rather than as a primary heater. Optional bi-fold glass doors add safety, and it is also approved for vented and vent-free gas logs. It vents through the IHP 12-inch 12DM chimney (12HT stainless in Canada), 16 to 50 ft tall. Choose the size by wall width and the scale of fire you want.

Key features

  • Three sizes: 36, 42 and 50-inch models; this is the 50-inch model, with a 50 in. wide x 30 in. tall opening.
  • Tall 30-inch opening with brick-to-face design: refractory extends to the front edge with no visible interior sheet metal.
  • Massive smoke dome: no visible smoke shelf, for a dependable draft and reliable operation.
  • Fully insulated firebox: increased performance in colder climates.
  • Refractory panels in two patterns with integrated ash lip: white stacked (WS) or white herringbone (WH).
  • Standard equipment: heavy-duty cast iron log grate with rugged forged andirons, mesh fire screens and an easy-access damper control at the top of the opening.
  • Optional glass doors and gas logs: black-trim bi-fold doors BD50 for improved safety; approved for vented (ANSI Z21.60/Z21.84) and vent-free (ANSI Z21.11.2) gas logs, with Superior's Granite Ridge, Silverstone Timber, Mossy Oak and Giant Timbers sets.
  • Dual outside air kits available: barometric dampers on both sides take left- and right-hand kits for maximum performance (two recommended).
  • Clean-face, zero-clearance design: durable textured powder-coat finish; installs in standard framing with 1-1/2 in. back and side clearance and 0 in. at the top spacers and floor, with a non-combustible hearth extension in front; IHP 12DM chimney, or 12HT stainless required for Canada.
  • Listed, 20-year limited warranty: UL 127 and CAN/ULC-S610 factory-built fireplace (PFS report F09-095); 20 years on the product body and firebox.

Specifications

Model WRT4550WS (white stacked) / WRT4550WH (white herringbone); catalog F0630 (WS) / F0631 (WH)
Series Superior WRT4500
Type Traditional open-hearth wood-burning fireplace, front view, factory-built (zero clearance), clean face
Unit dimensions 59-1/4" W x 67" H x 28-1/2" D overall (1505 x 1702 x 724 mm); 38-1/2" across the back (manual 126601-01 Fig. 3, p.6)
Framing dimensions 59-3/4" W x 67-1/8" H x 30-1/8" D (1518 x 1705 x 766 mm; manual Fig. 4, p.7; spec sheet 900737-00); corner: 71" (1804 mm) along each wall, 100" (2540 mm) across the front (Fig. 5, p.7)
Viewing area 50" W x 30" H fireplace opening (1270 x 762 mm), starting 7" above the base; refractory floor 50" wide at the front, 33-1/8" at the back, 23-1/4" deep (manual Fig. 3, p.6)
Clearances to combustibles Back and sides 1-1/2" (not required at the nailing flanges); top spacers 0"; floor 0"; ceiling 42"; front 48"; chimney outer pipe 2"; perpendicular side wall 18" from the opening; combustible trim or mantel 18" from the opening, projections over 1-1/2" at least 21" above the opening; mantel legs within the 33-degree safe zone: up to 11-1/2" projection at 18" from the side of the opening, nothing combustible over the 4-1/2" metal front face (Fig. 7); non-combustible hearth extension 74 x 20" (manual pp.6-8)
Hearth extension 74 x 20 in. minimum (manual pp.4-6)
Chimney IHP 12 in. 12DM double-wall (US); 12HT stainless (Canada)
Chimney height 16 ft minimum (22 ft with two offset sets); 50 ft maximum
Fuel Solid seasoned wood; approved for vented and vent-free gas logs
Included Refractory panels (WS or WH), cast iron grate with andirons, mesh screens, damper, ember protector
Shipping weight 630 lb (spec sheet 900737-00)
Listing UL 127 / CAN/ULC-S610, PFS report F09-095
Warranty 20-year limited (body and firebox)

Dimensions and clearances

  • Framing: 67-1/8 in. high x 59-3/4 in. wide x 30-1/8 in. deep (manual Fig. 4, p.7; spec sheet 900737-00).
  • Fireplace: 59-1/4 in. wide x 67 in. high x 28-1/2 in. deep, 38-1/2 in. across the back; opening 50 in. wide x 30 in. high, 7 in. above the base (manual Fig. 3, p.6).
  • Corner framing: 71 in. along each wall from the corner and 100 in. across the front between the walls (manual Fig. 5, p.7).
  • Clearances to combustibles: back and sides 1-1/2 in. (not required at the nailing flanges); top spacers 0 in.; floor 0 in.; ceiling 42 in.; 48 in. in front of the fireplace; chimney outer pipe 2 in.; a perpendicular side wall 18 in. from the opening. Do not pack the air spaces with insulation (p.7).
  • Hearth extension: non-combustible, at least 20 in. in front of the opening and 12 in. beyond each side (74 x 20 in. for this size), with a thermal conductivity (k) of 0.84 BTU-in/ft2-hr-°F or less at 1 in. thick; seal the gap to the fireplace with non-combustible material and use the supplied ember protector (pp.4-8).
  • Mantels and trim: combustible trim or a mantel projecting from the face must stay at least 18 in. from the opening; combustibles that project more than 1-1/2 in. must be at least 21 in. above the top of the opening; mantel legs may project up to 11-1/2 in. at 18 in. from the side of the opening, tapering along a 33-degree line toward it, and combustibles must not overlap the 4-1/2 in. metal front face (Fig. 7, p.8).
  • Combustible materials may reach the side edge of the black metal face but may not overlap the face; non-combustible facing may overlap if it blocks no openings, set with non-combustible mortar or adhesive only (pp.8, 15).

What's included

  • WRT4550 fireplace with fully insulated firebox and damper with easy-access control
  • White refractory panel set, stacked F3278 (WS) or herringbone F3281 (WH), with corner retainers
  • Heavy-duty cast iron log grate with forged andirons (J4345)
  • Mesh fire screens (J4340)
  • Ember protector J6906 for the hearth extension joint

Required (sold separately)

  • Chimney: IHP 12DM in the US (12HT stainless in Canada) - pipe sections for at least 16 ft (22 ft with two offset sets), a termination (round top RLT-12D, or square chase top STL-12D / STL-12DMP; Canada RLT-12HT), firestop spacers FS-10 at each floor or ceiling (with an FST10 thimble where the chimney enters an attic), and roof flashing V6F-10DM or V12F-10DM with storm collar SC2-1 when the chimney passes through a roof
  • Chimney support 12S-12DM (12S-12HT in Canada) when more than 20 ft of chimney would rest on the fireplace, and with offsets
  • Canada: cold air collar kit CAK-12 (also recommended in cold US regions)
  • Non-combustible hearth extension material (by the installer)

Optional accessories

  • 50 in. black-trim bi-fold glass doors BD50 (F1008)
  • Outside combustion air kits: AK4 (F1091, complete kit with collars, hood and 3 ft flex), AK4F (F1093, for floor venting), AK4X (collar and hood only) - two kits recommended
  • 30-degree offset and return with adapter 30E-12DM-B (F5169; Canada 30E-12HT-B)
  • Refractory stain kits, 1 qt: Creamer BSK-CR, Rust BSK-RT, Cappuccino BSK-CP (H8176-H8178)
  • Vented or vent-free gas log set listed for this fireplace (Superior Granite Ridge, Silverstone Timber, Mossy Oak or Giant Timbers)

No official Superior video is published for the WRT4500; we will add one if Superior releases it.

Installation and safety notes

⚠ Important: A wood fireplace that is installed, operated or maintained incorrectly can cause a house fire or carbon-monoxide exposure. This fireplace must be installed by a qualified professional following the Superior WRT4536/42/50 installation manual (P/N 126601-01 Rev. P), with only the listed IHP chimney components, and inspected by your local building official where required.

Safety

  • Listed to UL 127 and CAN/ULC-S610 (PFS report F09-095) as a factory-built fireplace for wood, vented gas logs and vent-free gas log heaters (p.1).
  • Never alter or modify the fireplace or its components; overfiring (scrap lumber, pine branches, cardboard, trash, treated wood) can permanently damage it and is not covered by the warranty (pp.1, 3).
  • Inspect the chimney at least twice each heating season and remove creosote once it reaches 1/8 in.; know the flu-like early signs of carbon monoxide (p.3).
  • Keep children and pets away from the hot opening and screen; the fireplace is for supplemental heat only (p.2).

Specifications

  • Framing 67-1/8 x 59-3/4 x 30-1/8 in.; hearth extension 74 x 20 in.; shipping weight 630 lb (pp.4-7; spec sheet).

Fireplace installation: location, framing and clearances

  • Clearances: back and sides 1-1/2 in., top spacers and floor 0 in., ceiling 42 in., front 48 in., chimney 2 in., 18 in. to a perpendicular side wall (p.7).
  • Non-combustible hearth extension at least 20 in. deep and 12 in. past each side of the opening; a raised platform needs a field-made Z-type ember protector of 28-gauge or heavier galvanized steel (p.8).
  • Mantels: combustible trim 18 in. from the opening; projections over 1-1/2 in. at least 21 in. above the opening (p.8).
  • Manufactured homes: keep the floor, wall and ceiling/roof structure intact, and never install in a sleeping room of a mobile home (p.10).

Venting installation: outside air and chimney

  • Two outside air kits are highly recommended; never terminate the air duct in an attic, and keep the air inlet no more than 3 ft below the chimney flue outlet (p.9).
  • Use only IHP 12DM (US) or 12HT stainless (Canada) chimney components; label visible sections with label 900599-01 (p.9).
  • Minimum system height 16 ft straight or with one elbow set, 22 ft with two; 50 ft maximum; a chimney supported only by the fireplace may not exceed 20 ft (pp.7, 9-10).
  • Offsets: 30-degree offset/return, a maximum of two offsets, 6 ft maximum angled run between supports, at least one 12S-12DM (12S-12HT) support; secure offset joints with two screws in the outer pipe only (pp.10, 27).
  • Firestop spacers at every floor penetration; a firestop and thimble where the chimney enters an attic to keep insulation away (p.11).
  • At the roof the chimney must extend at least 36 in. above the highest point where it passes through the roof and 30 in. above the roof cutout; use flashing V6F-10DM (0-6/12) or V12F-10DM (6/12-12/12) with storm collar SC2-1 (pp.11, 24).
  • 10-foot rule: the top must be at least 3 ft above the roof penetration and 2 ft above any roof surface within 10 ft (p.13).
  • Chases: shortest vertical side at least 30 in., 19 in. minimum inside; terminations in multiple chases at least 24 in. apart center to center and 18 in. offset vertically; never seal ventilation openings (pp.13-15).

Finishing the fireplace

  • Combustible materials may not overlap the face; non-combustible facing may overlap with non-combustible mortar or adhesive only (p.15).

Refractory panels installation

  • Install the refractory panels after the fireplace is in its permanent location, with the side-panel gas line knockouts facing down (p.16).
  • Replace the grate only with the Innovative Hearth Products grate listed in the parts list (p.16).

Optional gas line installation

  • Vented gas logs must be listed to ANSI Z21.60 or Z21.84 and installed per NFPA 54; vent-free gas log heaters must be listed to ANSI Z21.11.2 (p.17).
  • Use a 1/2 in. black iron gas line and leak-test with soapy water, never a flame; clean the firebox and chimney of soot, creosote and ash before converting to gas (p.17).
  • With vented gas logs the damper must be removed or locked fully open and the glass doors fully open; never run an unvented gas log with the chimney removed (pp.3, 17-18).

Operation and maintenance guidelines

  • Lock the damper fully open and open the glass doors before lighting; operate the doors only fully open or fully closed, let the glass warm slowly and never clean hot glass with cool water (p.18).
  • Burn only dry, seasoned solid wood under 20% moisture (softwood 6-18 months, hardwood 12-24 months); never gasoline, lighter fluid, treated wood or trash (pp.3, 27).
  • Appendix A gives draft and smoke guidelines: a draft reading of 0.04-0.08 in. W.C. and as few offsets as possible (pp.26-27).

Accessories

  • Glass doors BD50 (F1008), outside air kits AK4/AK4F, chimney parts 12DM/12HT, offsets 30E-12DM-B/30E-12HT-B, supports 12S-12DM/12S-12HT, firestop FS-10, thimble FST10, flashings V6F-10DM/V12F-10DM, storm collar SC2-1, terminations RLT-12D/RLT-12HT/STL-12D/STL-12DMP, refractory stain kits BSK (pp.23-24).

Important notices for Canada

  • Check with the authority having jurisdiction first; Canadian code requires a stainless chimney, so use the 12HT parts together with the CAK-12 cold air collar kit (AP-12HT anchor plate where called for) (pp.1, 9, 25).

Building code information

Warranty

  • Coverage: Superior wood-burning fireplace 20 Year Limited Warranty (P/N 900224-00 Rev. B), printed in the installation manual (p.29).
  • Product body and firebox: 20 years from installation. Ceramic glass: thermal breakage only.
  • Removable air tubes: 7 years. Refractory, side shields and screens: 2 years (hairline cracks excluded). Gold and nickel plating: 2 years (tarnishing excluded).
  • Air tubes, baffles, brick retainers, cast-iron parts, gaskets and electrical components: 1 year. Optional glass doors: 90 days. Fuel grates: 90 days (defects only). Parts not listed: 90 days.
  • Vent components, trim, paint and applied stains are not covered by the 20-year term.
  • Labor: paid at IHP's prevailing rates during each component's warranty period, up to five years.
  • Who is covered: the original owner only (not transferable), bought from a listed IHP supplier with proof of purchase, installed in the US or Canada.
  • Conditions: installed and repaired by a licensed, IHP-approved contractor to codes, using only the chimney components specified in the manual, and operated and maintained per the instructions.
  • Exclusions: normal wear; accident, fire or flood; abuse, negligence or alteration; overfiring and unapproved fuels; lack of maintenance; faulty installation; draft or smoking problems from HVAC, chimney height, trees, buildings or wind; incidental damages.
  • Claims: contact the selling dealer; if that is not possible, notify IHP in writing within 90 days of the failure.

Downloads

California Proposition 65

WARNING: This product can expose you to chemicals including Carbon Black, which is known to the State of California to cause cancer, and Carbon Monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

Flames and flame colors on the website may appear differently in real life.

Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.

Frequently asked questions — WRT4550

What size framing does the WRT4550 need?

Frame an opening 59-3/4 in. wide x 67-1/8 in. high x 30-1/8 in. deep, keeping 1-1/2 in. clearance at the back and sides (not needed at the nailing flanges). For a corner, the framing runs 71 in. along each wall and 100 in. across the front. The fireplace itself is 59-1/4 in. wide, 67 in. high and 28-1/2 in. deep.

What chimney does it use, and how tall must it be?

The IHP 12-inch 12DM double-wall chimney in the US, or 12HT stainless in Canada. The system must be at least 16 ft tall (22 ft with two offset sets) and no more than 50 ft.

What hearth extension does it need?

A non-combustible hearth extension at least 20 in. in front of the opening and 12 in. beyond each side, 74 x 20 in. for this size.

Can I burn gas logs in it?

Yes. It is approved for vented decorative gas logs (ANSI Z21.60/Z21.84) and vent-free gas log heaters (ANSI Z21.11.2). Superior offers Granite Ridge, Silverstone Timber, Mossy Oak and Giant Timbers sets for the series.

How high must a mantel be?

Combustible trim or a mantel must stay at least 18 in. from the opening, and anything projecting more than 1-1/2 in. must be at least 21 in. above the top of the opening. Mantel legs may project up to 11-1/2 in. at 18 in. from the side of the opening, tapering along a 33-degree line toward it, and combustibles must not overlap the metal front face.

What is the warranty?

A 20-year limited warranty on the product body and firebox, for the original owner.