Superior 48" Linear Direct Vent Gas Fireplace DRL6048TEN
SKU / Model: DRL6048TEN
Fireplace only$7,179.00
Black Friday Savings applied in your cart
Unlock an exclusive offer on this product.
Product overview
The Superior DRL6048TEN is the 48-inch model in the DRL6000 Series, a fully featured, clean-face linear direct vent gas fireplace from Innovative Hearth Products, also made in 60, 72 and 84-inch sizes. It suits contemporary and transitional rooms, and comes with a factory-installed blower, floor lighting and a full-function remote as standard.
An expansive ceramic glass opening frames flames rising through platinum crushed glass over a black porcelain liner that mirrors the fire. Floor lighting glows through the media with or without a fire, in six levels. Reflective black or blue glass, ice rock, river rock or driftwood media and a black linear trim kit can change the look, and it is the only DRL6000 size offered with indoor see-through and indoor/outdoor see-through kits.
On natural gas it runs from 35,000 down to 23,500 BTU/hr through six flame settings, and it converts to propane (31,000 to 25,500 BTU/hr). Electronic ignition has four AA batteries as backup. It vents with Secure Vent SV4.5 or Secure Flex SF4.5 up to 40 ft vertically, or with the optional PVK-PF2-SV4.5 power vent.
Key features
- 48-inch linear model: the DRL6000 Series also comes in 60, 72 and 84-inch sizes.
- See-through options: indoor see-through kit STK-DVLIN48, and indoor/outdoor kit OSTK-LIN48 (48-inch only).
- Six flame settings: 35,000 to 23,500 BTU/hr on natural gas, up to a 30% turn-down.
- Electronic ignition with battery backup: IPI with selectable CPI; four AA batteries keep it lighting in an outage.
- Factory-installed blower and floor lighting: six blower speeds and six light levels (blower not used with see-through installs).
- Black porcelain liner and platinum crushed glass: two 5 lb bags included, with optional colors and media.
- Multi-function remote included: flame, blower, lighting and a thermostat with Smart mode.
- Clean-face design: integrated tile stops and ceramic glass with a protective screen meeting ANSI Z21.50/Z21.88.
- Flexible venting: SV4.5 / SF4.5 direct vent, horizontal or vertical, or the PVK-PF2-SV4.5 power vent; HeatFlo kit option.
- Certified and convertible, 20-year limited warranty: ANSI Z21.88/CSA 2.33 and CSA 2.17 (report F22-797); bedrooms and manufactured homes; propane kit GCK-SM-6048NP.
Specifications
| Model | DRL6048TEN (natural gas, electronic ignition; catalog F4847) |
|---|---|
| Series | Superior DRL6000 linear direct vent |
| Type | Clean-face linear direct vent gas fireplace, front view (see-through with kit) |
| Unit dimensions | 54-1/4 in. W (57-7/16 in. across the side tabs) x 39 in. H (base to the top of the standoffs; 32-7/8 in. to the top of the case, 33-5/8 in. to the top of the flue collar) x 20 in. D (spec sheet 901227-02, top, front and side views) |
| Framing dimensions | 55-5/8 in. W x 39-1/8 in. H x 19-1/2 in. D one-sided; 18-1/2 in. deep see-through; 84 in. minimum from the fireplace base to the ceiling; 1-1/2 in. minimum from the framed opening to the ceiling (manual p.12; spec sheet 901227-02) |
| Viewing area | 46 in. W x 14-1/2 in. H glass (spec sheet 901227-02, front view) |
| Clearances to combustibles | Back 3/4 in. and sides 1/2 in. to the wrapper; 0 in. at spacers, top of standoffs and floor; 84 in. minimum from the unit bottom to the ceiling; 36 in. in front of the viewing area; vent pipe 1 in. around vertical runs, 3 in. above and 1 in. at the sides and bottom of horizontal runs; combustible side walls 8-1/4 in. from the opening for up to a 12 in. projection, or 14 in. for any length (manual Table 1 p.11; Fig. 39 p.36) |
| Drawing dimensions (as lettered on Superior's drawing) | A 54-1/4 in (overall width, top view) · B 27-1/8 in (side to vent centre, top view) · C 46 in (glass width) · D 50-3/8 in (width of the front frame, front view) · E 57-7/16 in (width across the side tabs, front view) (manual Fig. 11, p.16; spec sheet 901227-02) |
| Input, natural gas (max / min) | 35,000 / 23,500 BTU/hr |
| Input, propane after conversion (max / min) | 31,000 / 25,500 BTU/hr |
| Efficiency testing | CSA P.4.1 (P4/EnerGuide) |
| Minimum base-to-ceiling height | 84 in. |
| Ignition | SIT Proflame electronic ignition, IPI with selectable CPI, battery backup (4 AA) |
| Gas supply | NG 5.0-10.5 in. WC (5.5-7.0 recommended); LP 11.0-13.0 in. WC |
| Manifold pressure | NG 1.6 low / 3.5 high in. WC; LP 6.3 low / 10.0 high in. WC |
| Orifice | #36 (0.1065 in.) NG; #52 (0.0635 in.) LP |
| Electrical | 120 VAC, 60 Hz, unswitched, grounded |
| Venting | Superior SV4.5 / SF4.5 4-1/2 x 7-1/2 in. direct vent or PVK-PF2-SV4.5 power vent |
| Blower | Factory installed, six speeds |
| Lighting | Floor lighting, six levels |
| Remote | Multi-function remote included |
| Media included | 2 x 5 lb platinum reflective crushed glass |
| Unit weight | 293 lb (spec sheet 901227-02) |
| Shipping weight (estimated) | 323 lb |
| Certification | ANSI Z21.88/CSA 2.33, CSA 2.17 (PFS TECO report F22-797) |
Dimensions and clearances
- Framing (one-sided): 55-5/8 in. wide x 39-1/8 in. high x 19-1/2 in. deep; see-through framing depth 18-1/2 in. (manual p.12).
- Corner framing: 54-1/4 x 93-15/16 in. with a 47 in. face (manual p.16).
- Minimum 84 in. from the fireplace base to the ceiling; enclosure height 60 in. with a vertical vent (no elbows inside) or 84 in. with a horizontal vent (Table 1, p.11).
- Clearances to combustibles: back 3/4 in. and sides 1/2 in. to the wrapper; spacers, standoff tops and floor 0 in. (Table 1, p.11).
- Front: keep furniture and combustibles 36 in. from the glass (p.11).
- Vent pipe: 1 in. around vertical runs; 3 in. above and 1 in. at the sides and bottom of horizontal runs (p.11).
- Mantels: combustible mantel legs may extend beside the opening only within the side-wall safe zone (Fig. 39); non-combustible mantels are allowed (p.12).
- Side walls: a combustible side wall may project 12 in. at 8-1/4 in. from the opening, or any length at 14 in. (Fig. 39, p.36).
- TV above: at least 12 in. above the opening on a flush wall (TV 3 in. below the vent opening; vent opening 4 in. below the ceiling), or 18 in. in a recessed pocket up to 3-1/2 in. deep (pp.13-15).
What's included
- Fireplace with burner and SIT Proflame electronic controls
- Ceramic glass with protective barrier screen
- 2 x 5 lb bags of platinum reflective crushed glass
- Non-combustible fireboard set (top, bottom and two sides) and 1 in. self-drilling screws
- Battery holder with 4 AA batteries for backup operation
- Black porcelain liner, factory-installed blower and floor lighting
- Multi-function hand-held remote with 3 AAA batteries
Required (sold separately)
- Superior SV4.5 / SF4.5 4-1/2"x7-1/2" direct vent system: a horizontal termination (SV4.5HT-2, SV4.5TK90HT2, SF4.5HT-2 or an SFKIT flex kit) or a vertical termination (SV4.5GV-1 with roof flashing SV4.5F, SV4.5FA or SV4.5FB, or SFVT30/SFVT45 for flex), plus pipe, elbows and firestops for the route; or the PVK-PF2-SV4.5 power vent kit
- Indoor see-through installs: see-through conversion kit STK-DVLIN48 (the factory blower must be removed or disabled)
- Indoor/outdoor see-through installs: conversion kit OSTK-LIN48
- Propane installs: conversion kit GCK-SM-6048NP (propane back to natural gas: GCK-SM-6048PN)
- 120 VAC electrical supply and gas supply line (by the installer)
Optional accessories
- HeatFlo convection kit (catalog F4453) and HeatFlo flex extension (F4578)
- Black linear trim kit TRMK-BLK-LIN48
- Reflective black glass liner kit CGLK-BLK-LIN48 (not for see-through)
- High-definition driftwood log set DRFTWD-LOGDV48 (not for see-through)
- Driftwood pieces and rock media kit DRFTWD-ROCK-KIT
- River rock, 25-piece kit (F3775)
- Crushed glass, 5 lb bags (order two): reflective black CRSHGL-RBLK, reflective blue CRSHGL-RBLU, platinum CRSHGL-P
- Ice rock media, 5 lb (order two; F3507-F3509)
- Touch-up paint: firebox interior SCITPSAB, powder-coat exterior SCTPSAB
Product video
Official Superior videos for the DRL6048TEN:
Installation and safety notes
⚠ Important: Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This fireplace must be installed and serviced by a qualified professional following the Superior DRL4048/DRL6048 installation manual (P/N 901227-00 Rev. D). If you ever smell gas, do not light any appliance or touch electrical switches; leave the building and call your gas supplier from outside.
Product and safety information
- Listed by PFS TECO (report F22-797) to ANSI Z21.88/CSA 2.33 and CSA 2.17 as a vented gas fireplace heater for the US and Canada; approved for bedrooms and manufactured homes (p.8).
- Natural gas from the factory; propane only with the certified conversion kit. Never connect to private wellhead gas (pp.6, 28).
- High altitude: approved for 0-4,500 ft (0-1,372 m) above sea level with the standard burner orifices. Above 4,500 ft the input must be reduced, either with gas derated by the gas company or with a smaller burner orifice as set by the local authority and NFPA 54/ANSI Z223.1; in Canada, a high-altitude conversion is carried out by a manufacturer's authorized representative to CSA 2.17 (p.10).
- Massachusetts: 248 CMR 4.00-8.00 applies, including a licensed gas fitter, a T-handle shutoff and a hard-wired CO detector when a horizontal termination is under 7 ft (p.9).
- Manufactured homes: do not cut or weaken cross members; ground to the chassis (p.10).
Pre-installation and framing
- Frame 55-5/8 x 39-1/8 x 19-1/2 in. (18-1/2 in. see-through) with 84 in. minimum to the ceiling (p.12).
- Clearances: back 3/4 in., sides 1/2 in. to the wrapper, 0 in. at spacers, standoffs and floor; 36 in. in front of the glass. Do not pack insulation around the fireplace (p.11).
- The blower kit and reflective glass liner are not compatible with the see-through kits (p.12).
Installing a TV above the fireplace
- Flush wall: 12 in. minimum above the opening, 3 in. below the vent opening, with the vent opening 4 in. below the ceiling. Recessed pocket: 18 in. above the opening, 3-1/2 in. maximum depth (pp.13-15).
- IHP gives these TV clearances as guidance only (p.13); the optional HeatFlo kit (F4453) sends heat out through vents above the fireplace.
Termination location and venting
- Use Superior Secure Vent SV4.5, Secure Flex SF4.5 or Z-Flex Model GA 4-1/2 x 7-1/2 in. components only; never common-vent (p.18).
- Vertical 2 ft minimum to 40 ft maximum; combined vertical and horizontal up to 55 ft with up to three elbows; set the restrictor to the run (pp.20-23).
- Slope horizontal runs 1/4 in. per foot rise toward the termination and support every 4 ft; never run the vent downward (pp.18-20).
- Flex: up to 40 ft in total, minimum 5 in. bend radius, supported every 2 ft; flex may not pass through ceilings, attics or walls (pp.20, 24).
- Walls 6 to 9-1/4 in. thick use the termination kit alone; a 12-1/8 in. square wall opening is needed (p.19).
- Horizontal termination clearances (manual Table 2, p.17): 12 in. above grade, a veranda, porch, deck or balcony; 9 in. (US) or 12 in. (Canada) from a window or door that opens and from a non-mechanical air inlet, at this model's 35,000 BTU/hr input; 9 in. (US) or 12 in. (Canada) recommended from a fixed window; 18 in. below a ventilated soffit within 18 in. horizontally; 12 in. below an unventilated soffit (30 in. below vinyl); 5 in. from an outside corner and 2 in. from an inside corner; 36 in. each side of a meter or regulator within 15 ft above it and from a regulator vent; 36 in. above a mechanical air inlet within 10 ft (US) or 72 in. (Canada); 84 in. above a public sidewalk or driveway; 12 in. under a veranda, porch, deck or balcony; alcoves at most 72 in. deep and at least 36 in. wide, 6 in. to the termination and 18 in. to combustibles above.
- Vertical terminations above the roof (Table 4, p.22): flat to 6/12 pitch 1 ft; 6/12-7/12 1.25 ft; 7/12-8/12 1.5 ft; 8/12-9/12 2 ft; 9/12-10/12 2.5 ft; 10/12-11/12 3.25 ft; 11/12-12/12 4 ft; 12/12-14/12 5 ft; 14/12-16/12 6 ft; 16/12-18/12 7 ft; 18/12-20/12 7.5 ft; 20/12-21/12 8 ft.
- Power vent: the PVK-PF2-SV4.5 kit is approved for this model with no adapter (manual p.26; kit instructions 901163-00, Table 2).
Gas
- Use 1/2 in. or larger gas pipe; supply NG 5.5-10.5 in. WC (5.5-7.0 recommended), LP 11-14 in. WC from an external regulator (pp.28-29).
- Propane conversion uses kit GCK-SM-6048NP; propane back to natural gas uses GCK-SM-6048PN (Table 8, p.57).
- Leak-test every joint with a non-corrosive solution, never a flame.
Electrical
- Run a 120 VAC, 60 Hz, single-phase, unswitched, grounded supply to the junction box on the left side (p.34).
- Four AA batteries keep the fireplace lighting in an outage; the blower and lighting need household power (p.41).
Fireplace installation and media
- Spread both 5 lb bags of glass evenly over the burner and media tray, finishing at the pilot; keep the pilot cover opening clear and never substitute other media (p.33).
- Optional logs and river rock follow their own kit instructions (p.33).
- Never run the fireplace with the glass removed, cracked or broken; keep the barrier screen in place.
Finishing
- Install the supplied 1/2 in. non-combustible fireboard and do not cover it with drywall or plywood; tile stops project 5/8 in. (pp.36-38).
- Facing must not block the louvers or overhang the glass; use sealants rated 300°F and 100% acrylic latex paint (p.38).
- Combustible side walls: 8-1/4 in. from the opening for up to a 12 in. projection, or 14 in. for any length (Fig. 39, p.36).
Operation and maintenance
- IPI is the default; switch to CPI (standing pilot) under the access cover for cold climates (p.41).
- Have a qualified technician inspect the burner, controls and vent before each season and replace the batteries; clean the firebox and glass after the season (p.54).
- The glass and surrounding surfaces get very hot: supervise children and pets and keep furniture 36 in. away.
Accessories named in the manual
- See-through kits STK-DVLIN48 (F4853) and OSTK-LIN48 (F4869), blower (F4868), remote (F3835), HeatFlo (F4453/F4578), glass liner CGLK-BLK-LIN48 (F4850), trim TRMK-BLK-LIN48 (F4852), driftwood logs DRFTWD-LOGDV48 (F4855), driftwood and rock (F4908), river rock (F3775), glass and ice rock media, touch-up paint, power vent kit (F4776) (pp.63-64).
Building code information
- Install to local codes or, where none apply, the current National Fuel Gas Code, ANSI Z223.1/NFPA 54 (pp.8-9).
- In Canada: CSA B149.1 Natural Gas and Propane Installation Code (pp.8-9).
- Electrical: National Electrical Code, ANSI/NFPA 70, or CSA C22.1 Canadian Electrical Code in Canada (pp.7, 9).
- Flex venting listings: UL 1777 and ULC S635 (p.18).
- Massachusetts: 248 CMR 4.00-8.00, with CO detection to NFPA 720 / UL 2034 (p.9).
Warranty
- Coverage: Innovative Hearth Products Superior Brand Gas Fireplaces, Stoves and Inserts Limited Warranty (P/N 900223-00 Rev. C), printed in the installation manual (p.65).
- Product body, firebox and barrier: 20 years. Ceramic glass: 20 years against thermal breakage only.
- Burner, gas components and gaskets: 1 year. Tempered glass: 1 year. Logs: 1 year, thermal breakage only.
- Optional blowers and remote controls: 1 year. Optional glass doors: 90 days. Parts not otherwise listed: 90 days.
- Labor: paid at IHP's prevailing rates during each component's warranty period, up to five years.
- Vent components, trim and paint are not covered by the 20-year term.
- Who is covered: the original owner only (not transferable); bought from an IHP-listed supplier, with proof of purchase.
- Conditions: installed in the US or Canada by an IHP-approved licensed contractor to local codes, and operated and maintained per the instructions.
- Exclusions: normal wear; accident, fire or flood; abuse, misuse or alteration; lack of maintenance; faulty installation; burning wood, coal or other solid fuel; draft problems caused by HVAC, the vent configuration or building conditions.
- Claims: contact the selling dealer; if that is not possible, notify IHP in writing within 90 days of the failure. Replacement parts are generally available for 10 years after the last manufacture date.
Downloads
- Installation and Operation Manual (DRL4048/DRL6048, P/N 901227-00)
- Specification Sheet (DRL4048/DRL6048, P/N 901227-02)
- DRL6000 Brochure
- DRL6000 Smart Sheet
- Power Vent Kit PVK-PF2-SV4.5 Instructions
California Proposition 65
WARNING: This product can expose you to chemicals including carbon black and carbon monoxide, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Frequently asked questions — DRL6048TEN
What size framing does the DRL6048TEN need?
Frame the opening 55-5/8 in. wide x 39-1/8 in. high x 19-1/2 in. deep for a front-view install, or 18-1/2 in. deep for see-through, with at least 84 in. from the fireplace base to the ceiling. Clearances are 3/4 in. at the back and 1/2 in. at the sides to the wrapper, and 0 in. at the spacers, standoff tops and floor.
What venting does it use, and how far can it run?
Superior Secure Vent SV4.5 rigid or Secure Flex SF4.5 4-1/2 x 7-1/2 in. direct vent pipe. Vertical runs go from 2 ft up to 40 ft, and combined vertical and horizontal runs up to 55 ft with up to three elbows; flex is limited to 40 ft in total. The PVK-PF2-SV4.5 power vent kit is approved for down-and-out routes with no adapter.
Can it be converted to propane?
Yes. It ships for natural gas and converts with Superior kit GCK-SM-6048NP. On propane it runs 31,000 BTU/hr high and 25,500 BTU/hr low.
Does it work in a power outage?
Yes. Four AA batteries keep the fireplace lighting during an outage. The blower and floor lighting need household power.
Can it be installed as a see-through or indoor/outdoor fireplace?
Yes. The indoor see-through kit is STK-DVLIN48 and the indoor/outdoor kit is OSTK-LIN48; the 48-inch size is the only DRL6000 model offered with the indoor/outdoor kit. For see-through installs the factory blower must be removed or disabled, and the reflective glass liner and driftwood log set cannot be used.
What's the warranty?
Superior's 20-year limited warranty covers the product body, firebox and barrier, and the ceramic glass against thermal breakage. The burner, gas components and gaskets are covered for 1 year, and labor is paid at IHP's rates during each component's term, up to five years. Coverage is for the original owner.
Loading component details…
Add to cart to see your price.