The Superior DRT4245 is the 45-inch model in the DRT4200 Series, a full-size traditional direct vent gas fireplace from Innovative Hearth Products. It suits buyers who want the classic look of a wood fire with the convenience of gas, and it comes with a factory-installed six-speed blower, six-setting interior lighting and a Proflame II full-function remote as standard.
The 21-inch-deep firebox holds a high-definition ceramic fiber log set on a heavy-duty grate, with volcanic stone and glowing embers. You choose two required finishing parts: an interior liner (black reflective porcelain, or Blackstone, Greystone or Blended Brown ceramic fiber) and a facade (the inside-fit Vista, or a Reflection or Craftsman overlap facade in black or warm chestnut).
On natural gas it runs from 42,000 down to 25,000 BTU/hr (propane 41,000 to 22,000 BTU/hr), with a P4 efficiency of 62.7%. Four AA batteries keep the fire working in a power outage; the blower needs household power. It vents from the top with Superior SV4.5 or SF4.5 direct vent pipe, up to 60 ft vertical, and is approved for bedrooms and US manufactured homes.
Key features
- Full-size 45-inch model: a 21-inch-deep firebox for a larger interior and log arrangement (the DRT4200 Series comes in 40 and 45-inch sizes).
- Dedicated top vent: Superior SV4.5 rigid or SF4.5 flex 4-1/2 x 7-1/2 in. direct venting, up to 60 ft vertical.
- Electronic ignition with seamless battery backup: Proflame II IPI keeps working in a power outage on 4 AA batteries; continuous pilot is disabled per the IHP addendum (manual p.9).
- Factory-installed blower and lighting: six blower speeds and six interior lighting settings.
- Full-function remote included: thermostat, flame height, blower and lighting.
- Ceramic glass with protective screen: optimum heat transfer and outstanding heating efficiency; meets ANSI Z21.50/Z21.88 barrier requirements.
- High-definition ceramic fiber log set: with heavy-duty grate, volcanic stone and glowing embers.
- Required finishing choices: a Vista inside-fit or Designer overlap facade (Reflection or Craftsman) and a black reflective porcelain or ceramic fiber liner; durable textured powder-coat finish.
- Approved locations: bedrooms and manufactured homes (manual p.8; manufactured homes US only, p.12); no hearth extension required (p.16).
- Certified, with a 20-year limited warranty: ANSI Z21.88/CSA 2.33 and CSA 2.17 (PFS TECO report 16-120); 20 years on the product body, firebox and barrier.
Specifications
| Models | DRT4245TEN-E natural gas (catalog F5017); DRT4245TEP-E propane (catalog F5018) |
|---|---|
| Series | Superior DRT4200-E traditional direct vent |
| Type | Traditional top-vent direct vent gas fireplace, front view |
| Unit dimensions | 45-1/4" W x 37-1/8" H x 21" D overall; 42-7/8" wide at the base (dimensions E, A, J and H, manual Table 12, p.18) |
| Framing dimensions | 45-7/8" W x 41-1/4" H x 23" D (depth with 1/2" drywall); corner installation 61" along each back wall, 85-7/8" across the front between the back walls and 40-1/2" from the front to the corner, with 45-7/8" front framing width; minimum height for top vent installations 55-3/4" (spec sheet 901277-01 framing table; manual p.18). Framing figures do not apply to flexible venting. |
| Viewing area | 39-1/4" W x 24-1/2" H glass viewing area (dimensions D and C, manual Table 12, p.18) |
| Clearances to combustibles | Back 1-1/2" and sides 1/2" to the wrapper, 0" at the spacers; top standoffs 0"; floor 0"; 64" minimum from the unit base to the ceiling; vent pipe 3" above and 1" at the sides and bottom; 36" service clearance in front; top-vent shelf height 68" with a Secure Vent rigid elbow or 70" with a Secure Flex elbow (manual p.15); combustible mantels 8" above the hood at 2" deep, up to 18" above at 12" deep (spec sheet mantel chart) |
| Input, natural gas (high / low) | 42,000 / 25,000 BTU/hr |
| Input, propane (high / low) | 41,000 / 22,000 BTU/hr |
| Efficiency (P4) | NG 62.7%; LP 62.4% |
| Minimum unit base to ceiling | 64 in. |
| Ignition | Proflame II electronic ignition (IPI), battery backup (4 AA) |
| Gas supply | NG 5.0-10.5 in. WC; LP 11.0-13.0 in. WC |
| Manifold pressure | NG 3.5 in. WC; LP 10.0 in. WC |
| Orifices | NG rear #35, front #52; LP rear #52, front #61 |
| Altitude | 0-4,500 ft standard; derate above |
| Electrical | 120 VAC, 60 Hz, single-phase, grounded |
| Venting | Top vent, Superior SV4.5 / SF4.5 4-1/2 x 7-1/2 in. direct vent |
| Blower | Factory installed, six speeds |
| Lighting | Interior lighting, six settings |
| Remote | Proflame II full-function remote included |
| Media included | Ceramic fiber log set on grate, volcanic stone, glowing embers |
| Shipping weight | 223 lb (spec sheet 901277-01) |
| Certification | ANSI Z21.88/CSA 2.33, CSA 2.17 (PFS TECO report 16-120) |
Dimensions and clearances
- Framing: 45-7/8 in. wide x 41-1/4 in. high x 23 in. deep (with 1/2 in. drywall); corner installation 61 in. along each back wall, 85-7/8 in. across the front and 40-1/2 in. to the corner; minimum height for top vent installations 55-3/4 in. (spec sheet framing table; manual p.18). Framing figures do not apply to flexible venting.
- Unit: 45-1/4 in. wide x 37-1/8 in. high x 21 in. deep overall, 42-7/8 in. wide at the base (manual Table 12, p.18).
- Glass viewing area: 39-1/4 in. wide x 24-1/2 in. high (dimensions D and C, manual Table 12, p.18); firebox 21 in. deep (spec sheet).
- Minimum 64 in. from the bottom of the unit to the ceiling (p.15).
- Clearances to combustibles: back 1-1/2 in. and sides 1/2 in. to the wrapper, 0 in. to spacers; top standoffs and floor 0 in.; 3 in. above and 1 in. beside and below horizontal vent pipe; 36 in. service clearance in front (p.15).
- Shelf height with a top-vent 90-degree elbow: 68 in. with a Secure Vent rigid elbow, 70 in. with a Secure Flex elbow (includes 3 in. clearance; p.15).
- Mantels: a combustible mantel 2 in. deep may sit 8 in. above the hood, and each extra 2 in. of depth needs 2 in. more height, up to 12 in. deep at 18 in. above (spec sheet mantel clearance chart); combustible mantel legs may project up to 3-1/2 in. from the fireplace face at its side edge, plus 1 in. more for each inch farther out (a 45-degree line), up to the 6 in. line where a combustible side wall may extend any length (Fig. 5); non-combustible mantels may be at any height above the opening but nothing may hang below the hood (pp.15-16).
- TV or shelf above: do not insulate the space between the fireplace and the shelf; high-temperature paint rated 175°F or more is recommended under a mantel (pp.15-16).
- No hearth extension is required; if one is used, it must not block the lower control compartment door (p.16).
What's included
- Fireplace with burner, Proflame II electronic controls, factory-installed six-speed blower and interior lighting
- High-definition ceramic fiber log set (J8303) with heavy-duty grate, volcanic stone and glowing embers
- Ceramic glass
- Proflame II full-function remote and wall switch / battery holder (4 AA backup batteries)
- Non-combustible fireboard and standoffs
Required (sold separately)
- One interior liner (required): black porcelain BPLK45-DVA, or ceramic fiber Blackstone FLK4045BLK, Greystone FLK4045GREY or Blended Brown FLK4045BB
- One facade (required): Vista black FVFBK45T (includes barrier screen), Reflection black FRBK45T or warm chestnut FRWC45T, or Craftsman black FCBK45T or warm chestnut FCWC45T
- Superior SV4.5 / SF4.5 4-1/2"x7-1/2" direct vent system: a vertical termination (SV4.5GV-1 or SV4.5CGV-1 with roof flashing) or a horizontal termination (SV4.5HT-2, SV4.5TK90HT2, SF4.5HT-2 or an SFKIT flex kit), plus pipe, elbows and firestops for the route
- Propane installs on a natural gas unit: conversion kit GCKSIT4245ENP (propane back to natural gas: GCKSIT4245EPN)
- 120 VAC electrical supply and gas supply line (by the installer)
Optional accessories
- Stainless steel surrounds: four-sided SURR45-SS4S-B or three-sided SURR45-SS3S-B
- Stone stop kit, 45 in. (catalog F4053)
- Termination guards (87L02, H5820) and elbow heat shield (F4066)
- Touch-up paint: firebox interior SCITPSAB, powder-coat exterior SCTPSAB
Product video
Official Superior videos for the DRT4200 Series:
Installation and safety notes
⚠ Important: Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This fireplace must be installed and serviced by a qualified professional following the Superior DRT4000-E/DRT4200-E installation manual (P/N 901277-00 Rev. B). If you ever smell gas, do not light any appliance or touch electrical switches; leave the building and call your gas supplier from outside.
Product and safety information
- Listed by PFS TECO (report 16-120) to ANSI Z21.88/CSA 2.33 and CSA 2.17 as a vented gas fireplace heater; approved for bedrooms and manufactured homes (p.8). Manufactured homes: US only, where local codes allow (p.12).
- Natural gas or propane from the factory; it cannot be converted without the certified kit. Never connect to private wellhead gas (pp.7-8).
- High altitude: standard orifices cover 0-4,500 ft; derate above that (p.10).
- Massachusetts installations must follow 248 CMR 4.00-8.00 (p.11).
- The fireplace is heavy: use help when moving it (p.4).
Location and clearances
- Back 1-1/2 in. and sides 1/2 in. to the wrapper, 0 in. at spacers, standoffs and floor; 64 in. from the unit base to the ceiling; 36 in. service clearance in front (p.15).
- Top-vent shelf height 68 in. (rigid elbow) or 70 in. (flex elbow) (p.15).
- Combustible mantels: 8 in. above the hood at 2 in. deep, up to 18 in. above at 12 in. deep (2 in. higher for each extra 2 in. of depth); do not insulate between the fireplace and a shelf (pp.15-16).
Framing
- Frame 45-7/8 in. wide x 41-1/4 in. high x 23 in. deep with 1/2 in. drywall; for a corner install, frame 61 in. along each back wall, 85-7/8 in. across the front and 40-1/2 in. from the front to the corner (p.18).
- The flush-mount bracket kit F3695 is available for flush installations (p.21).
Venting
- Use Superior Secure Vent SV4.5 or Secure Flex SF4.5 (or Z-Flex GA listed to UL 1777/ULC S635) 4-1/2 x 7-1/2 in. components only (p.8).
- Vertical runs up to 60 ft; horizontal runs follow the venting tables, for example up to 25 ft horizontal with two 90-degree elbows or 20 ft with three (pp.31-32).
- DRT4200 models need at least 1 ft of vertical pipe off the fireplace before the first elbow (p.26).
- Set the restrictor as the tables require for longer vertical rises (pp.24, 36-37).
- Terminations: vertical SV4.5CGV-1 or horizontal SV4.5HT-2; termination clearances follow the manual (pp.21, 34-35).
- Use the attic insulation shield (H3907) where the vent passes through an insulated attic (p.28).
Gas
- Inlet pressure NG 5.0-10.5 in. WC, LP 11.0-13.0 in. WC; manifold NG 3.5 in. WC, LP 10.0 in. WC (p.9).
- Conversion kits: GCKSIT4245ENP (natural gas to propane) and GCKSIT4245EPN (propane to natural gas), installed per their own instructions (p.55).
- Leak-test every joint with a non-corrosive solution, never a flame.
Electrical
- Run a 120 VAC, 60 Hz, single-phase, three-wire grounded supply to the junction box; on the DRT4200 the outlet must be wired directly to the breaker box (pp.41-43).
- Wire to local codes or the National Electrical Code ANSI/NFPA 70 (CSA C22.1 in Canada) (p.8).
- Four AA batteries in the receiver keep the fireplace working in an outage, except the blower; replace them before each season (pp.8, 58-59).
Finishing and facades
- Install the chosen facade and barrier before operating the fireplace (pp.49-51).
- Non-combustible surrounds may cover the face but never the glass or the control compartment; combustible materials may come down only to the top of the fireboard (p.16).
- Use high-temperature sealant (Mill-Pac 10K81, rated 700°F) where the manual calls for it (p.11).
Liners, logs and media
- Install the firebox liner first; a liner is required on DRT4200-E models (pp.47, 59-61).
- Place the seven-piece log set J8303 on the grate pins exactly as shown; spread volcanic stone and glowing embers without covering burner ports (pp.62-64).
- Replace the glowing embers every year (p.64).
Operation, first fire and maintenance
- Initialize the Proflame II remote to the receiver; the remote controls on/off and six flame levels plus the thermostat, light and blower functions (pp.46, 71).
- Expect odor and haze while paint cures on the first burns; ventilate the room, do not run the blower during break-in, and keep the glass clean so the film does not bake on (p.58).
- Have a qualified technician inspect and clean the burner, logs, pilot, controls and vent every year before the season; clean the glass two or three times a season (pp.67-69).
- Never operate with the glass removed, cracked or broken; the glass gets very hot, so supervise children and pets (pp.5, 7).
Accessories named in the manual
- Vista facade F5027 (45 in.), Reflection and Craftsman facades, premium barrier F3667, liners F4322-F4324 and black porcelain F2915, stone stop F4053, flush-mount kit F3695, termination guards 87L02/H5820, elbow heat shield F4066, wall switch kits, touch-up paint F1881/F1882 (pp.53-54, 59-61, 70-72).
Building code information
- Install to local codes or, where none apply, the current National Fuel Gas Code, ANSI Z223.1/NFPA 54 (p.8).
- In Canada: CSA B149.1 Natural Gas and Propane Installation Code (p.8).
- Electrical: National Electrical Code, ANSI/NFPA 70, or CSA C22.1 Canadian Electrical Code in Canada (p.8).
- Flex venting listings: UL 1777 and ULC S635 (p.8).
- Massachusetts: 248 CMR 4.00-8.00 (p.11).
Warranty
- Coverage: Innovative Hearth Products Superior Brand Gas Fireplaces, Stoves and Inserts Limited Warranty (P/N 900223-00 Rev. C), printed in the installation manual (pages after p.81).
- Product body, firebox and barrier: 20 years. Ceramic glass: 20 years against thermal breakage only.
- Burner, gas components and gaskets: 1 year. Tempered glass: 1 year. Logs: 1 year, thermal breakage only.
- Optional blowers and remote controls: 1 year. Optional glass doors: 90 days. Parts not otherwise listed: 90 days.
- Labor: paid at IHP's prevailing rates during each component's warranty period, up to five years.
- Vent components, trim and paint are not covered by the 20-year term.
- Who is covered: the original owner only (not transferable); bought from an IHP-listed supplier, with proof of purchase.
- Conditions: installed in the US or Canada by an IHP-approved licensed contractor to local codes, and operated and maintained per the instructions.
- Exclusions: normal wear; accident, fire or flood; abuse, misuse or alteration; lack of maintenance; faulty installation; burning wood, coal or other solid fuel; draft problems caused by HVAC, the vent configuration or building conditions.
- Claims: contact the selling dealer; if that is not possible, notify IHP in writing within 90 days of the failure. Replacement parts are generally available for 10 years after the last manufacture date.
Downloads
- Installation and Operation Manual (DRT4000-E/DRT4200-E, P/N 901277-00)
- Specification Sheet (DRT4000-E/DRT4200-E, P/N 901277-01)
- Superior Full-Size Direct Vent Gas Brochure
- DRT4200 Smart Sheet
California Proposition 65
WARNING: This product can expose you to chemicals including carbon black and carbon monoxide, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Frequently asked questions — DRT4245
What size framing does the DRT4245 need?
Frame the opening 45-7/8 in. wide x 41-1/4 in. high x 23 in. deep (depth with 1/2 in. drywall), with 2x4 or larger lumber. For a corner installation, the framing runs 61 in. along each back wall, 85-7/8 in. across the front between the back walls and 40-1/2 in. from the front to the corner. Top vent installations need at least 55-3/4 in. of framed height. These framing figures apply to rigid venting, not flexible venting.
What venting does it use, and how far can it run?
It is a dedicated top-vent unit for Superior Secure Vent SV4.5 rigid or Secure Flex SF4.5 4-1/2 x 7-1/2 in. direct vent pipe. Vertical runs go up to 60 ft; horizontal runs follow the venting tables, for example up to 25 ft horizontal with two 90-degree elbows or 20 ft with three. At least 1 ft of vertical pipe is needed off the fireplace before the first elbow.
Can it be converted between natural gas and propane?
Yes, with the certified kit only: GCKSIT4245ENP converts natural gas to propane and GCKSIT4245EPN converts propane to natural gas.
Does it work in a power outage?
Yes. Four AA batteries in the receiver keep the electronic ignition and fire working during an outage. The blower needs household power.
Is a remote included?
Yes. The Proflame II full-function remote is included and controls the fire on and off, six flame levels, a room thermostat, the blower and the interior lighting.
What is the warranty?
20 years on the product body, firebox and barrier, and 20 years on the ceramic glass against thermal breakage. The burner, gas components and gaskets are covered for 1 year, logs for 1 year against thermal breakage, and the blower and remote for 1 year. Coverage is for the original owner.