Superior 32" Direct Vent Gas Fireplace Insert, NG DRI2032TEN

SKU / Model: DRI2032TEN

Free Fast Shipping
In-stock items are processed in 1–2 business days.

$3,149.00

Black Friday Savings applied in your cart

YOUR SPECIAL OFFER IS AVAILABLE

This product qualifies for an exclusive special offer.

Complete your selections and add this product to your cart to unlock the eligible offer.

Offer eligibility and final promotional pricing are confirmed in the cart. Accessories qualify separately. Offers may change.

Product overview

The Superior DRI2032 is the 32-inch model in the DRI2000 Series of direct vent gas fireplace inserts from Innovative Hearth Products. It turns an existing wood-burning masonry or zero-clearance fireplace into an efficient, sealed gas heater that lights at the touch of a remote or switch, with no wood, ash or chimney draft to manage.

The traditional look pairs a detailed ceramic fiber log set and glowing embers with a black painted interior behind ceramic glass. A required full front facade (41 x 25 in. or 43 x 32 in.) finishes the opening and carries the safety barrier, and the 4-sided trimmable surround can frame the medium facade.

On natural gas it runs from 28,000 down to 16,000 BTU/hr, and on propane from 25,000 to 14,000 BTU/hr, with a factory-installed 140 CFM variable-speed blower to move the heat into the room. Electronic ignition with an IPI/CPI switch and four AA backup batteries keeps it lighting in a power outage. It vents through two 3 in. flex liners up the existing chimney, and is approved for bedrooms and manufactured homes in the US.

Key features

  • Fits existing fireplaces: approved for zero-clearance and masonry fireplaces with a front opening of at least 32 in. wide x 19-1/2 in. high, 22 in. rear width and 16 in. depth.
  • Two sizes: 27 and 32-inch heat-circulating models (this is the 32-inch).
  • 28,000 BTU/hr pan burner: 28,000 / 16,000 BTU/hr on natural gas, 25,000 / 14,000 on propane, with adjustable flame height.
  • Efficiency: 70% AFUE natural gas / 67% propane; P.4.1 57% / 61%.
  • Factory-installed blower: 140 CFM variable speed; the fireplace runs without it.
  • Electronic ignition with battery backup: IPI/CPI switch; four AA batteries run it (without the blower) in a power outage.
  • Traditional look: detailed ceramic fiber logs with glowing embers, black painted interior, ceramic glass for heat transfer.
  • Full front facades with barrier: one required (41 x 25 or 43 x 32 in.); optional 46 x 38 in. trimmable 4-sided surround.
  • Optional Ecoflow controls: EF-BRCK basic remote or EF-WWRCK wireless wall switch.
  • 20-year limited warranty: IHP Superior gas fireplace, stove and insert warranty, with labor paid up to five years.

Specifications

Model DRI2032TEN (natural gas, electronic ignition); field-convertible to propane
Series Superior DRI2000 direct vent gas insert
Type Direct vent gas fireplace insert, front view, traditional
Unit dimensions 31-5/8" W x 19-3/8" H x 15-7/8" D; 21" wide at the back (manual Fig. 2: D front width, A height, B depth, E back width). Facades: 41" W x 25" H (FP4125-BDVI32) or 43" W x 32" H (FP4332-BDVI32)
Minimum fireplace opening 32" front width (held for 3" into the firebox) x 19-1/2" H; 22" rear width; 16" deep (manual p.13)
Viewing area 25-3/4" W x 15-3/8" H front opening (manual Fig. 2: H and G)
Clearances to combustibles Combustible mantel 32" minimum (A) with mantel depth 10" (C); side wall 4" (B); hearth protection 10" in front of the insert when its base is at hearth level, or 0" when the base is 4" or more above the hearth extension, using 1/2" thick non-combustible material (k 0.84) or equivalent (manual Fig. 4, p.14)
Input, natural gas (high / low) 28,000 / 16,000 BTU/hr (0-2,000 ft)
Input, propane (high / low) 25,000 / 14,000 BTU/hr (0-2,000 ft)
Efficiency 70% AFUE NG / 67% LP; P.4.1 57% NG / 61% LP (manual p.12)
Gas supply Minimum inlet 5.0 in. WC NG, 10.5 in. WC LP; manifold 3.5 / 1.2 in. WC NG, 10.0 / 3.2 in. WC LP
Orifice (0-2,000 ft) #38 (0.101 in.) NG; #53 (0.0595 in.) LP
Ignition Electronic, IPI/CPI switch, battery backup (4 AA)
Electrical 120 VAC, 60 Hz, less than 2 A; three-prong plug, power cord included
Blower 140 CFM variable speed, factory installed
Venting Direct vent, vertical only: two 3" flex liners (UL1777 exhaust; UL181 or UL1777 intake), 10 ft minimum to 35 ft maximum from the base of the insert
Controls Optional EF-BRCK basic remote (on/off, IPI/CPI) or EF-WWRCK wireless wall switch (on/off, high/low)
Shipping weight 96 lb (manual p.35)
Certification ANSI Z21.88/CSA 2.33, CGA 2.17-M91 and UL 307B (manufactured homes), USA and Canada (report 16-204)
Warranty 20-year limited

Included components

  • Insert body with factory-installed variable-speed blower and black interior panels
  • Ceramic fiber log set and bag of embers
  • Power cord
  • Literature package with warning labels and hardware kit (four 1/4-20 x 2.5 in. leveling bolts, facade screws, washers and nuts)

Required components

  • One full front facade (includes the safety barrier): FP4125-BDVI32 3-sided, 41 x 25 in. (F3133) or FP4332-BDVI32 3-sided, 43 x 32 in. (F3134)
  • Venting, complete kit: DuraVent 46DVA-CL33 co-linear kit (two 3 in. x 35 ft flex liners, appliance adaptor, chimney-top flashing and termination cap)
  • Or venting as separate parts: 2 x DuraVent 3DFA-35 3 in. x 35 ft flex liner (one exhaust, one combustion-air intake)
  • With separate parts: DuraVent 46DVA-GK chimney-top adaptor with flashing
  • With separate parts: one termination cap, DuraVent 46DVA-VCH high-wind cap with 46DVA-VWG vertical windguard, or DuraVent 46DVA-VC low-profile cap
  • Also approved: Selkirk 4DT-VT termination cap, 4DT-CTB vent adaptor and 3 in. liners AF35-03, AF25-03 or AF15-03 (35, 25 or 15 ft)
  • Vent limits: vertical only, up an existing non-combustible chimney; 10 ft minimum to 35 ft maximum from the base of the insert; the chimney is sealed around the cap, so no storm collar is used; no horizontal termination is listed (manual p.15-16)
  • 120 VAC grounded outlet and gas supply line (by the installer)

Optional accessories

  • FP4638-4S-MPDVI32 4-sided trimmable surround, 46 x 38 in. (F2311) - fits the FP4125-BDVI32 medium facade only
  • EF-BRCK basic remote control, on/off, IPI/CPI (F2687)
  • EF-WWRCK wireless wall switch, on/off, high/low (F2660)
  • Gas conversion kits: BI32-CK-NG to LP (F3125) and BI32-CK-LP to NG (F3124)

Installation and safety notes

⚠ Important: Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This insert must be installed and serviced by a qualified professional following the Superior DRI2027/DRI2032 installation manual (P/N 900787-04 Rev. H). If you ever smell gas, do not light any appliance or touch electrical switches; leave the building and call your gas supplier from outside.

Safety and listing

  • Never operate the insert with the glass removed, cracked or broken; the barrier supplied with the required facade must be installed (pp.2, 5).
  • Listed to ANSI Z21.88/CSA 2.33 as a vented gas fireplace heater; approved for bedrooms and for aftermarket, permanently located manufactured homes (USA only) where local codes allow (pp.1, 12).
  • Massachusetts: licensed plumber or gas fitter, T-handle shutoff, 36 in. maximum flexible connector (p.11).

Gas, altitude and electrical

  • Ships for natural gas; only IHP conversion kits may convert it (BI32-CK-NG to LP / BI32-CK-LP to NG) (pp.12, 35).
  • Above 2,000 ft (4,500 ft in Canada) the orifice is derated 4% per 1,000 ft (p.10).
  • The blower needs 120 VAC through the three-prong plug; the burner runs on four AA backup batteries in an outage (pp.12, 21).

Fireplace and clearances

  • The existing fireplace and chimney must be clean, in good working order and built of non-combustible materials; remove or lock the damper so both liners pass. In a factory-built fireplace whose damper will not pass both liners, the insert may not be installed (p.16).
  • Minimum fireplace opening 32 in. front width (held for 3 in. into the firebox) x 19-1/2 in. high, 22 in. rear width, 16 in. deep (p.13).
  • Mantel 32 in. (A) with 10 in. mantel depth (C); side wall 4 in. (B); hearth protection 10 in. in front at hearth level, or 0 in. with the base 4 in. above the hearth extension, 1/2 in. non-combustible, k 0.84 (Fig. 4, p.14).
  • Level the insert with the four adjustable corner legs (1/4 in. wrench) (p.14).

Venting

  • Two 3 in. listed flex liners: exhaust UL1777 only; intake UL181 or UL1777. Keep the liners vertical, avoid bends and do not let them sag; seal the chimney around the listed direct-vent cap (pp.15-16).
  • Vertical height 10 ft minimum to 35 ft maximum, measured from the base of the unit to the end of the liner; at maximum height use the standing (CPI) pilot (p.15; spec sheet).
  • Flue restrictor (0 open, 3 closed): natural gas position 1 up to 25 ft, 2 above 25 ft; propane 0 at 10-15 ft, 1 at 15-25 ft, 2 above 25 ft; factory setting 1 (spec sheet).

Logs, operation and maintenance

  • Place the logs on their notches and tabs and spread the embers as shown in the log diagrams (pp.18-19).
  • Adjust the air shutter (left opens, right closes) gradually if soot forms (p.21).
  • Have the insert inspected and cleaned by a qualified technician; wear gloves and safety glasses for maintenance, and use only doors certified for the appliance (pp.25-28).

Warranty

  • IHP Superior brand gas fireplaces, stoves and inserts 20-year limited warranty (P/N 900223-00), from the date of purchase (or first occupancy in new construction, no later than 24 months after shipment).
  • IHP repairs or replaces covered components found defective in materials or workmanship, and pays its labor rates for up to five years; installation in the USA or Canada per the instructions and codes is required, and the warranty is non-transferable.

Downloads

Configuration and Controls

This DRI2032TEN insert is supplied for natural gas with electronic ignition. Select one full-front facade. The FP4638-4S-MPDVI32 trimmable surround fits only the FP4125-BDVI32 (F3133) facade. The blower, logs and black interior panels are included. EF-BRCK and EF-WWRCK controls are optional.

California Proposition 65

WARNING: This product can expose you to chemicals including Carbon Black, which is known to the State of California to cause cancer, and Carbon Monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

Flames and flame colors on the website may appear differently in real life.

Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.

Frequently asked questions — DRI2032

What size fireplace does the DRI2032 fit?

The existing fireplace opening must be at least 32 in. wide at the front (held for 3 in. into the firebox), 19-1/2 in. high, 22 in. wide at the back and 16 in. deep. The insert body is 31-5/8 in. wide x 19-3/8 in. high x 15-7/8 in. deep, and it works in masonry and zero-clearance fireplaces.

What venting does it use?

Two 3 in. flex liners run up the existing chimney, one exhaust (UL1777) and one combustion-air intake (UL181 or UL1777), to a listed direct-vent cap: for example the DuraVent 46DVA-CL33 co-linear kit. The vertical height must be 10 ft to 35 ft from the base of the insert; there is no horizontal option.

Can it be converted to propane?

Yes. It ships for natural gas and converts with the IHP BI32-CK-NG to LP kit (F3125). On propane it runs from 25,000 to 14,000 BTU/hr.

Does it work in a power outage?

Yes. Four AA batteries keep the electronic ignition and burner working; the blower needs 120 V household power.

Is a remote included?

No. Choose the optional EF-BRCK basic remote (on/off, IPI/CPI) or the EF-WWRCK wireless wall switch (on/off, high/low).

How high must a mantel be?

A combustible mantel needs 32 in. minimum clearance with a 10 in. mantel depth, and a combustible side wall needs 4 in. Hearth protection must extend 10 in. in front when the insert sits at hearth level, or 0 in. when its base is 4 in. or more above the hearth extension.

Loading component details…

Add to cart to see your price.

Call for best price

Similar Products