Real Fyre G9 20/24/30" Vent-Free Log Burner G9-20/24/30
SKU / Model: G9-20/24/30
Base price$778.00
Early Black Friday Savings applied in your cart
Unlock an exclusive offer on this product.
Product overview
The Real Fyre G9 is a vent-free burner system with dancing flames, a glowing ember bed and a reflective panel that radiates heat into the room. One G9-20/24/30 burner fits the 20", 24" and 30" Real Fyre G9 log sets, and the G9-2-24 is the see-thru version for two-sided fireplaces with a 24" see-thru set. Both are ANSI certified as unvented room heaters (Z21.11.2) and vented decorative appliances (Z21.60), with an ODS safety pilot.
The G9-20/24/30 produces 36,000 BTU/hr on natural gas or propane and comes with a manual valve, an on/off remote ("12"), the "12" valve without remote ("12M"), a variable remote ("15", down to 21,000 BTU/hr) or the "15" valve without remote ("15M"). The G9-2-24 see-thru burner produces 39,000 BTU/hr with the on/off "12" or "12M" valve. Glowing embers, Bryte Coals and lava granules are included; logs are sold separately: Golden Oak Designer (RD9), Split Oak (S9) and Meadow Oak (M9).
Key features
- Reflective panel. Radiates heat during operation and after shutoff.
- One burner, three log sizes. G9-20/24/30 fits 20", 24" and 30" sets.
- See-thru option. G9-2-24 burns on both faces of a two-sided fireplace.
- ODS safety pilot. Shuts the gas off before room oxygen drops below 18%.
- Embers, Bryte Coals and lava granules included.
- Natural gas or propane. Factory built for one gas; not field convertible.
Included components
- G9 burner with ODS pilot assembly, flex connector CK-7 (3/8" O.D. x 12"), damper clamp DC-1, glowing embers EM-9, Bryte Coals EMV-1 and lava granules LF-5 (G9-2: two packs of each)
- Manual models: manual valve with PR-2NAT / PR-1LP regulator and piezo igniter
- "12" models: SV-8 / SV-8P on/off valve with toggle switch and piezo, basic on/off remote (RR-1A) and heat shield HS-36 ("12M" ships without the remote kit)
- "15" models: SV-24 / SV-25 variable valve, basic variable remote (VR-1A) and heat shield HS-36 ("15M" ships without the remote kit)
Required components
- A Real Fyre G9 vent-free log set (sold separately): Golden Oak Designer (RD9), Split Oak (S9) and Meadow Oak (M9) in 20", 24" or 30" for the G9-20/24/30; the matching 24" see-thru set (RD9-2-24, S9-2-24 or M9-2-24) for the G9-2-24
- A solid-fuel masonry or UL-127 factory-built fireplace that meets the minimum dimensions below
- A 1/2" minimum gas supply with a shut-off valve, installed by a qualified gas professional
Control options
- Manual valve with ODS pilot: A manual control valve with pressure regulator and the ODS (oxygen depletion sensor) safety pilot, lit with the built-in piezo igniter and operated at the knob.
- On/off remote (12): Series "12" valve with an on/off toggle switch and a basic on/off remote (transmitter with 12V battery, receiver with 4 AA batteries). Can also be used with a Real Fyre wall switch or wall thermostat.
- On/off valve, remote not included (12M): The same series "12" on/off valve, supplied without the remote transmitter and receiver (R.H. Peterson book: "W/12M"). Add a Real Fyre remote or wall switch separately if wanted.
- Variable remote (15): Series "15" valve with ignition knob and a basic variable remote (12V transmitter battery, 4 AA in the receiver) to turn the fire on and off and raise or lower the flame.
- Variable valve, remote not included (15M): The same series "15" variable valve, supplied without the remote transmitter and receiver (R.H. Peterson book: "W/15M"). A Real Fyre variable remote (VR-1A / VR-2A) can be added separately.
Specifications
| Brand / series | Real Fyre by R.H. Peterson, G9 vent-free burner system |
|---|---|
| Appliance type | Vent-free (unvented) gas log burner with ODS, ANSI Z21.11.2; also certified as a vented decorative appliance (ANSI Z21.60); logs sold separately |
| Gas inlet pressure | Natural gas 5" to 10.5" w.c. (3.5" outlet on high); propane 11" to 13" w.c. (10" outlet on high) |
| Power | No house power needed: remote receiver 4 AA batteries, transmitter one 12V battery |
| Room size | Room volume (L x W x H) x 20 = maximum BTU allowed |
| Clearances | Sidewalls 6" from the opening; ceiling 42" from the top of the opening; 12" noncombustible above the opening without a hood (10" with a hood; heat-resistant material at least 5/8" thick); 12" noncombustible floor in front if the fireplace is less than 6" above the floor; ash lip no more than 3/4" (G9-2) |
| Elevation | Ratings to 2,000 ft; above that consult R.H. Peterson / the National Fuel Gas Code |
Sizes
| Burner | Log set | Heat input (NG and LP) | Minimum fireplace |
|---|---|---|---|
| G9-20/24/30 | 20" | 36,000 BTU/hr high; 21,000 low on "15" models | 28" x 24" x 14" x 17" (front x rear x depth x height) |
| G9-20/24/30 | 24" | 36,000 BTU/hr high; 21,000 low on "15" models | 32" x 24" x 14" x 17" (front x rear x depth x height) |
| G9-20/24/30 | 30" | 36,000 BTU/hr high; 21,000 low on "15" models | 36" x 28" x 14" x 17" (front x rear x depth x height) |
| G9-2-24 see-thru | 24" see-thru | 39,000 BTU/hr | 28" wide x 18" deep x 17" high |
Installation and safety notes
This is a vent-free (unvented) decorative appliance with an oxygen depletion sensor (ODS) that shuts the burner off before the oxygen level in the room falls below 18%. Size the room before you buy: the room volume (length x width x height) multiplied by 20 is the maximum BTU input allowed, so a 36,000 BTU burner needs at least 1,800 cubic feet. Do not install in a bedroom or bathroom (units over 10,000 BTU/hr may not be installed in bedrooms), never leave it burning unattended or while anyone sleeps, and never burn wood or other solid fuel in the fireplace. Glass doors must be fully open during operation. Check local codes: some areas restrict or prohibit vent-free appliances. Input ratings apply up to 2,000 ft elevation.
Indoor fireplaces only. Use only the gas type on the rating plate, place the logs exactly as the log placement instructions show, keep the damper clamp installed, and have the burner and ODS pilot inspected yearly. Massachusetts installations must follow 527 CMR and 248 CMR. Install per the R.H. Peterson manual, local codes and ANSI Z223.1 / NFPA 54.
Safety warnings and disclaimer
WARNING: Burning natural gas or propane in this decorative appliance produces combustion byproducts, including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information, visit www.p65warnings.ca.gov.
INSTALLATION SAFETY: For your safety, follow the manufacturer's installation and operating instructions exactly. An incorrect installation can lead to a fire, property damage or personal injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
DISCLAIMER: Flames and flame colors on the website may appear differently in real life.
Warranty summary
Real Fyre vent-free burners, valves and logs carry R.H. Peterson's limited warranty for the original purchaser; see the Real Fyre warranty page for current terms by component.
Manufacturer manuals and downloads
- G9 vent-free burner owner's manual (L-F2-068)
- Vent-free DOs and DON'Ts
- Real Fyre Vent-Free Catalog
- G9-2 see-thru vent-free burner owner's manual (L-F2-083)
- Golden Oak Designer and Split Oak log set instructions (F2-127)
- Golden Oak Designer and Split Oak see-thru log set instructions (F2-134)
Frequently asked questions — G9
Which logs fit the G9?
The Real Fyre Golden Oak Designer (RD9), Split Oak (S9) and Meadow Oak (M9) sets: 20", 24" or 30" on the G9-20/24/30, and the 24" see-thru versions (RD9-2-24, S9-2-24, M9-2-24) on the G9-2-24.
Is there a variable-flame see-thru G9?
No. The G9-2-24 see-thru burner is offered with the on/off "12" valve, with or without the remote kit ("12M").
Loading component details…
Add to cart to see your price.