Napoleon Tall Bay Luxuria 50 Gas Fireplace TLVX50LBN
SKU / Model: TLVX50LBN
Fireplace only$14,289.00
Black Friday Savings applied in your cart
Unlock an exclusive offer on this product.
Product overview
The Napoleon Tall Bay Luxuria 50 (TLVX50LBN) is a built-in, direct vent natural gas fireplace with a tall 56 1/8" wide opening that can be installed three ways: as a three-sided bay fireplace, as a corner fireplace, or single-sided. That flexibility makes it a striking choice for open-plan homes, peninsulas, room ends and feature walls where a standard linear unit would not fit the design.
It burns with Napoleon's Luminous Log technology: the flame rises straight out of the logs, and a modulating electric ember bed glows underneath, so the fire looks like a real wood fire from every side. Choose Oak, Driftwood or Birch high-definition luminous logs. Porcelain reflective radiant panels, top accent lighting and the NIGHT LIGHT feature finish the look, and the slim border keeps the face clean and modern.
Gas input on natural gas is up to 36,000 BTU/h with a turn-down to 19,000 BTU/h through a split-flow burner (the propane model is rated 31,500 to 15,000 BTU/h). Napoleon's Dynamic Heat Control is included: it moves heat away from the wall above and circulates it through a ventilated enclosure, so combustible framing and finishes can come close to the opening and the wall above stays cooler for a TV, sound bar or artwork. Ducted Dynamic Heat Management is optional when you want to route heat elsewhere.
Heat-safe glass means there is no screen in front of the view. The ProFlame II remote and eFIRE controller are included, so you can run the fireplace from the remote or the eFIRE app, and the battery back-up control system keeps it working in a power outage.
The fireplace vents through 5" x 8" direct vent pipe from Wolf Steel, Metal-Fab, BDM, Simpson DuraVent or Selkirk, with vertical runs up to 40 ft; propane installs need rigid vent or a power vent. Compared with the standard Luxuria, the Tall Bay version gives a taller fire, Luminous Logs and multi-sided viewing. It is built in Ontario, Canada, and covered by Napoleon's President's Limited Lifetime Warranty.
Key features
- Up to 36,000 BTU/h: natural gas input; turn-down to 19,000 BTU/h
- Three-sided, corner or single-sided installation: corner and ledge kits for three-sided installs
- Luminous Log technology: flames rise directly out of the logs
- Oak, Driftwood or Birch high-definition luminous logs: required selection, chosen in the configurator
- Modulating electric ember bed: lifelike glowing embers
- NIGHT LIGHT feature
- Top accent lighting
- Sleek face with slim border
- Porcelain reflective radiant panels included: MIRRO-FLAME
- ProFlame II remote and eFIRE controller included: eFIRE app control
- Split-flow burner with pilot-on-demand: manual pp.41-42
- Dynamic Heat Control included: passive heat distribution; DHC Plus and ducted DHM optional
- Designed for TVs above: reduced temperatures above the opening (manual p.20)
- Heat-safe glass, no screen needed: heat-radiating inner ceramic glass with glass guard
- Battery back-up control system: works during a power failure
- Stainless steel flex connector
- Easy-access air control
- Firestop / vent shield: first 30" of vertical vent shielded (manual p.28)
- Approved for bedrooms, bathrooms and bed-sitting rooms; mobile home certified: manual p.5
- Certified to CSA 2.22 / ANSI Z21.50
- Made in Ontario, Canada
- President's Limited Lifetime Warranty
Specifications
| Model | TLVX50LBN (natural gas, electronic ignition) |
|---|---|
| Unit dimensions | 56 1/8" W x 51 13/16" H (including top stand-offs; cabinet 46" at the side) x 20 1/4" D (including the 2 1/8" front projection) (manual p.11) |
| Framing dimensions | Flush framing: 56 9/16" (1437 mm) W x 88" (2235 mm) minimum enclosure height x 20 1/2" (521 mm) D; maximum enclosure height 10 ft; maximum framing member depth 3 1/2"; bottom of appliance to ledge board 50" (1270 mm); 7 1/2" (191 mm) from the top of the appliance to side framing. Overhang framing: 64 1/8" (1629 mm) W x 24 3/16" D with a 21 15/16" framing opening (manual pp.27-28, 43-44) |
| Viewing area | 56 1/8" W x 21" H (portal); three-sided, corner or single-sided |
| Clearances to combustibles | 0" to the back standoffs and the bottom of the appliance; 6" (152 mm) minimum inside the enclosure; outside the enclosure 3" (76 mm) at the top and 1" (25 mm) at the sides and bottom; 1" all round the vertical vent, with the first 30" of vertical vent shielded; combustible protrusions (mantels) up to 12" (305 mm) from the glass guard, and for deeper projections 2" more side and top clearance for every extra 1" of depth, up to 36" (manual pp.28, 46-47) |
| Fuel | Natural gas (propane is a separate model; conversion kits W175-0862 / W175-0864) |
| Gas input, natural gas | 36,000 BTU/h max / 19,000 BTU/h min (manual p.6) |
| Gas input, propane model | 31,500 BTU/h max / 15,000 BTU/h min (manual p.6) |
| Inlet gas pressure | NG 4.5" w.c. min, 7" w.c. max; LP 11" min, 13" max; never above 13" w.c. (manual p.6) |
| Manifold pressure | NG 3.5" w.c.; LP 10" w.c. (manual p.6) |
| Electrical | 115 V, 60 Hz, less than 12 A; hard-wired and grounded (manual pp.9, 36) |
| Venting | Direct vent, 5" exhaust / 8" intake (manual p.12) |
| Viewing | Three-sided, corner or single-sided |
| High altitude | Above 4,500 ft reduce input 4% per 1,000 ft (manual p.5) |
BTU figures are gas input ratings, not delivered heat output.
Dimensions and clearances
- Dynamic Heat Control front or rear air outlet: at least 80 sq in, centred and no more than 1 1/2" below the top of the enclosure (manual pp.23-24)
- Use high-temperature construction adhesive within 2" above and beside the opening and 8" below it; no fastener may penetrate the appliance more than 3/4" (manual p.45)
What's included
- Heat-safe glass with glass guard and view deflectors
- ProFlame II remote control (3 AAA) and eFIRE controller
- Battery holder / wall switch (4 AA)
- Modulating electric ember bed and top accent lighting
- Porcelain reflective radiant panels
- Corner and ledge kits for three-sided installs
- Dynamic Heat Control system
- Stainless steel flex connector
- Firestop spacer and vent shield
- Lifting handles and hardware kit (manual p.10)
Required components
- Luminous log kit for the 50: Driftwood DLKTLV50L, Oak OLKTLV50L or Birch BLKTLV50L (manual p.51)
- 5" x 8" direct vent system from one approved manufacturer: Wolf Steel, Metal-Fab SureSeal, BDM Pro-Form, Simpson DuraVent DirectVent Pro, Selkirk Direct Temp (also Olympia Ventis, ICC EXCELDirect); never mix brands or combine rigid and flex (manual pp.12-13)
- Matching starter adapter: Metal-Fab 5NDA, DuraVent W175-0170, Selkirk 5DT-AAN, Olympia VDV-NA05-58F (manual p.12)
- Wall terminal (GD422R-2 or ST58U-1), roof kit (GD410 / GD411 / GD412) or periscope GD401 (manual p.13)
- Ventilated enclosure built to one of the four Dynamic Heat Control options (manual pp.20-25)
- Propane installs: rigid vent or power vent only (manual p.66)
Optional accessories
- Dynamic Heat Control Plus (DHCP) grill kit
- Ducted Dynamic Heat Management (DHM)
- Napoleon flex vent kits GD420 / GD430 (natural gas)
- Propane conversion kit (W175-0862 for 50, W175-0864 for 62)
Downloads
- Installation manual (W415-10008679)
- Product manual
- Brochure / feature cards
- Product support downloads
Installation and safety notes
⚠ Important: Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This fireplace must be installed and serviced by a qualified professional following Napoleon's installation manual. Keep children, pets, furniture and decor clear of the fireplace and its heat outlet.
General information (pp.5-10)
- Install and service by a qualified installer, service agency or gas supplier; in Massachusetts a licensed plumber or gas fitter (pp.5, 8).
- Never operate without the glass guard in place (pp.5, 49).
- Certified to CSA 2.22 / ANSI Z21.50; approved for bathrooms, bedrooms and bed-sitting rooms; mobile home certified to 24 CFR Part 3280 / CAN/CSA Z240 MH (pp.1, 5, 9).
- Ratings: 36,000 / 19,000 BTU/h natural gas; propane model 31,500 / 15,000 BTU/h (p.6).
- Above 4,500 ft, reduce input 4% for every 1,000 ft unless the local authority says otherwise (p.5).
Dimensions (p.11)
- Appliance width 56 1/8"; height 51 13/16"; depth 20 1/4".
Venting (pp.12-19, 29-35)
- 5" exhaust / 8" intake from approved brands only; do not mix brands or combine rigid and flexible pipe (p.12).
- Horizontal run up to 20 ft; vertical up to 40 ft; V + H no more than 40 ft; practical minimum rise 6 ft (pp.13, 15, 17).
- Flexible vent: up to two connections horizontal or three vertical; keep the 1 1/4" air gap; do not clamp flex pipe (pp.13, 29).
- Roof terminal top at least 16" above the highest roof penetration point; periscope needs 18" from an inside corner (pp.16, 33).
- Corner venting layout is in section 3.2 (p.14); a vent restrictor may be needed on vertical runs (pp.34, 52).
Installation planning (pp.20-25)
- Four enclosure options: open enclosure, front opening, rear opening, open enclosure with combustible valance; front/rear openings need at least 80 sq in (pp.22-25).
- Rear openings need direct air communication with the adjoining room, or airflow can reverse (p.24).
Rough framing and clearances (pp.26-28)
- Framing width 56 9/16" (1437 mm); depth 20 1/2"; minimum enclosure height 88" (2235 mm).
- 0" to back standoffs and floor; 6" inside the enclosure; 3" top and 1" sides outside; 1" around vertical vent (p.28).
Electrical (pp.36-39)
- Hard-wire, connect and ground per local codes (p.36).
- Do not wire 110 V to the valve or wall switch; do not modify the grounding plug (p.38).
Gas and operation (pp.40-42)
- Use the gas type on the rating plate; conversion only with the certified Napoleon kit (p.68).
- Pilot-on-demand and split-flow operation explained on p.42.
Finish framing and finishing (pp.43-51)
- Flush or overhang framing per pp.43-44; maximum enclosure height 10 ft.
- Follow fastener restrictions (p.45) and the mantel clearance chart (pp.46-47).
- Fit glass guard panes with gaskets and the 3 view deflectors (p.49).
- Lay media on the media tray only, never on the burner or pilot; place logs exactly as the leaflet shows (pp.50-51).
Maintenance (pp.55-61)
- Inspect appliance and venting before use and at least annually by a qualified technician (p.55).
- Turn off gas and power and let the unit cool before service; do not paint the pilot assembly (pp.55-56).
Building code information (pp.5, 8-9, 36, 40)
- US: local codes, or the latest National Fuel Gas Code, ANSI Z223.1/NFPA 54.
- Canada: CAN/CSA B149.1 and CSA C22.1 (CSA Group).
- Electrical (US): National Electrical Code, ANSI/NFPA 70.
- Manufactured homes: HUD 24 CFR Part 3280; Canada CAN/CSA Z240 MH.
- Massachusetts: licensed plumber or gas fitter, T-handle gas shutoff, flexible connector max 36", CO detector required (p.8).
Warranty
- Napoleon President's Limited Lifetime Warranty (Tall Luxuria Bay installation manual W415-10008679, section 17.0, pp.72-73).
- Lifetime, for as long as the original purchaser owns it: combustion chamber, heat exchanger, steel burner, PHAZER logs and embers, rocks, ceramic glass (thermal breakage only), gold-plated parts (tarnishing), porcelain enamel and aluminum trim.
- Electrical and millivolt components and wear parts (blowers, valves, switches, wiring, remotes, igniters, gaskets, pilot assemblies): free replacement in the first year.
- Labour: covered in the first year (gas log sets excluded).
- Years 1 to 10: repair or replacement of lifetime-covered parts free at Napoleon's discretion; from 10 years to life, parts at 50% of current retail.
- Who is covered: the original purchaser; non-transferable; starts at original installation; keep proof of purchase with model and serial number.
- Conditions: installed by an authorized installer following the manual and codes.
- Key exclusions: misuse, lack of maintenance, alteration, third-party parts, heat or cleaner damage, mechanical breakage of PHAZER logs, water or condensation damage, overfiring, downdrafts and inadequate venting or air supply; shipping, travel and diagnostic charges.
California Proposition 65
WARNING: This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Frequently asked questions — TLVX50LBN
What size framing does the TLVX50LBN need?
Flush framing is 56 9/16" (1437 mm) wide and 20 1/2" (521 mm) deep, with an enclosure at least 88" (2235 mm) tall and no more than 10 ft. Overhang framing is 64 1/8" (1629 mm) wide and 24 3/16" deep. The enclosure must be ventilated using one of the four Dynamic Heat Control options, with a front or rear air outlet of at least 80 sq in.
What venting does it use, and how far can it run?
It uses 5" x 8" direct vent pipe from one approved maker: Wolf Steel, Metal-Fab SureSeal, BDM Pro-Form, Simpson DuraVent DirectVent Pro, Selkirk Direct Temp, Olympia Ventis or ICC EXCELDirect, without mixing brands. Horizontal runs go up to 20 ft and vertical runs up to 40 ft, with vertical plus horizontal no more than 40 ft. Propane installs need rigid vent or a power vent.
Can it be converted to propane?
Yes, with Napoleon propane conversion kit W175-0862. On propane it is rated 31,500 BTU/h max and 15,000 BTU/h min.
Does it work in a power outage?
Yes. It is hard-wired at 115 V, 60 Hz (under 12 A), and the battery back-up control system (battery holder / wall switch, 4 AA batteries) keeps it working during a power failure.
Is a remote included?
Yes. The ProFlame II remote (3 AAA batteries) and the eFIRE controller are included, so you can also run the fireplace from the eFIRE app.
What is the warranty?
Napoleon's President's Limited Lifetime Warranty for the original purchaser. The combustion chamber, heat exchanger, burner, logs and embers, glass (thermal breakage) and porcelain and aluminum trim are covered for life, free in years 1 to 10 and at 50% of retail after that. Electrical components, wear parts and labour are covered in the first year.