Napoleon Tall Vector 62 See-Through Gas Fireplace TLV62LN2
SKU / Model: TLV62LN2
Fireplace only$17,249.00
Black Friday Savings applied in your cart
Unlock an exclusive offer on this product.
Product overview
The Napoleon Tall Linear Vector 62 See-Through with Luminous Logs (TLV62LN2) is a built-in, direct vent natural gas fireplace with a tall, frameless 62-inch linear opening. Its Luminous Log technology makes the flames rise straight out of the logs, so the fire looks and moves like real wood burning, and its see-through design, viewable from two rooms, makes it a centrepiece for a great room, a room divider, or a kitchen-to-living-room wall.
Inside, Napoleon's Woodland log kit is included with splinters, rocks, charcoal, glass and vermiculite, and you choose the Luminous log set that suits your room: Oak, Driftwood or Birch. Top accent lighting and an electric modulating ember bed glow on their own, so the fireplace looks good in every season, even with the flame off or turned low. The opening can be finished frameless for a clean architectural look, or framed with Napoleon's optional four-piece finishing trim.
Gas input is up to 44,000 BTU/h on natural gas (turn-down to 25,000 BTU/h); the propane version of this model is rated 38,000 to 21,000 BTU/h. A Hi/Lo split-flow burner lets you run a lower, more economical flame for ambience or full input when you want heat. Napoleon's optional heat management kits (DHC and DHM) move heat away from the wall above, which reduces clearances to combustibles and makes the unit well suited to a TV above.
The fireplace comes with a remote and also works with the eFIRE app on your phone. The battery back-up control system keeps it running during a power outage. It vents through 5" x 8" direct vent pipe from Wolf Steel, Metal-Fab, BDM, Simpson DuraVent or Selkirk, with horizontal runs up to 20 ft and vertical runs up to 40 ft, and flexible vent is allowed on natural gas installations. That gives designers and installers real flexibility for residential and commercial projects.
Compared with the standard Tall Linear Vector, the Luminous Logs version adds flame that comes out of the logs themselves and the glowing ember bed. Compared with the regular Vector series, the Tall models give a taller viewing area for a bigger, more dramatic fire. Napoleon builds it in Ontario, Canada, and covers it with the President's Limited Lifetime Warranty.
Key features
- Luminous Log technology: flames emerge directly from the logs for a true wood-fire look
- Choice of Oak, Driftwood or Birch Luminous logs: pick the log style that matches your room (selected in the configurator)
- Woodland log kit included: with splinters, rocks, charcoal, glass and vermiculite
- Up to 44,000 BTU/h natural gas input: propane version 38,000 BTU/h
- Hi/Lo split-flow burner: lower gas use for ambience, full input for heat (true four-season use)
- Top light illumination: accent lighting in the firebox
- Electric modulating ember bed: glowing embers that work with or without the flame
- Remote control included: or use the eFIRE mobile app
- ProFlame II and eFIRE controller: electronic ignition with pilot-on-demand
- Battery back-up control system: keeps the fireplace working in a power outage
- Frameless design: clean, architectural finish; optional 4-piece finishing trim available
- Optional heat management (DHC & DHM): reduces clearances to combustibles; designed for TVs above
- MIRRO-FLAME porcelain reflective radiant panels
- Heat-radiating ceramic glass with black premium safety barrier: barrier included and must always be installed (manual p.5)
- Stainless steel flex connector
- Easy-access air control
- Firestop / vent shield
- See-through design: enjoy the fire from two rooms at once
- Approved for bedrooms, bathrooms and bed-sitting rooms; mobile home certified: manual p.5
- Certified to CSA 2.22 / ANSI Z21.50: vented decorative gas appliance (manual cover, p.10)
- Ideal for residential and commercial projects
- Made in Ontario, Canada
- President's Limited Lifetime Warranty
Specifications
| Model | TLV62LN2 (natural gas, electronic ignition) |
|---|---|
| Unit dimensions | 75 5/16" W cabinet (77 5/16" W including side flanges) × 41" H cabinet (49 7/16" H including top stand-offs) × 16 3/16" D (manual section 2) |
| Framing dimensions | 77 13/16" (1976 mm) W × 16 3/16" (411 mm) D see-through framing; minimum enclosure/ceiling height 91" (2311 mm) measured from the bottom of the appliance; the appliance does not need to be raised above the floor (manual section 4, spec sheet) |
| Viewing area | 64 9/16" W × 26 13/16" H (1639 × 681 mm) finishing flange opening, viewable from both sides |
| Clearances to combustibles | Back and side stand-offs: 0"; floor/bottom of appliance: 0"; top: 3" (76 mm) outside the enclosure and 6" (152 mm) inside the enclosure above the vent pipe; sides: 2" (51 mm) outside the enclosure; vertical vent sections: 1" (25 mm) all around; no combustible finishing within 15 5/8" (397 mm) above or 7" (178 mm) either side of the opening; front: keep furniture and objects 4 ft (1.22 m) away; mantel: no single minimum is published, the required height above the opening increases with mantel depth (manual sections 4.1.1, 11.2-11.4) |
| Fuel | Natural gas (propane model is a separate SKU; conversion only with a certified kit) |
| Gas input, natural gas | 44,000 BTU/h max / 25,000 BTU/h min (manual p.6) |
| Gas input, propane model | 38,000 BTU/h max / 21,000 BTU/h min (manual p.6) |
| Inlet gas pressure | NG 4.5" w.c. min, 7" w.c. max (13" absolute max); LP 11" min, 13" max (manual p.6) |
| Manifold pressure | NG 3.5" w.c.; LP 10" w.c. (manual p.6) |
| Electrical | 115 V, 60 Hz, less than 12 A; hard-wire when framed in (manual pp.10, 40) |
| Venting | Direct vent, 5" exhaust / 8" intake (manual p.14) |
| Viewing | See-through |
| High altitude | Above 4,500 ft reduce input 4% per 1,000 ft (manual p.5) |
| Installation | Built-in, direct vent |
BTU figures are gas input ratings, not delivered heat output.
Dimensions and clearances
- Venting runs that need more vertical rise need a taller enclosure than the 91" minimum (manual p.28).
- Vertical vent: the first 30" is shielded (manual pp.29-30)
- Non-combustible finishing width (Q): 78 9/16" (manual p.54)
- Non-combustible protrusions up to 4" (10 cm); beyond that add 2" of side and top clearance for every 1" of projection (manual p.54)
- Recessed installs: recess (M) 3" (76 mm), can only be increased to 4" max by building a protrusion (manual p.49)
- TV above, without a heat management kit: at least 6" from the top of the finishing flange to the bottom of the TV, and at least 2.5" between a mantel and the bottom of the TV (manual section 11.5). The DHC and DHM heat management kits are designed for TVs above.
What's included
- Woodland log kit with splinters, rocks, charcoal, glass and vermiculite
- Remote control (eFIRE app compatible) and ProFlame II / eFIRE controller
- Black premium safety barrier
- MIRRO-FLAME porcelain reflective radiant panels
- Top accent lighting and electric modulating ember bed
- Stainless steel flex connector
- Firestop / vent shield
- Restrictor plate and mounting plate (RP5 / W500-0973) for vertical vent tuning (manual parts list)
Required components
- Luminous log kit for the 62: choose Birch, Oak or Driftwood in the configurator
- 5" x 8" direct vent system from one approved manufacturer (Wolf Steel, Metal-Fab SureSeal, BDM Pro-Form, Simpson DuraVent DirectVent Pro or Selkirk Direct Temp; do not mix brands) with the matching starter adapter: Metal-Fab 5NDA, DuraVent W175-0170, Selkirk 5DT-AAN, Ventis VDV-NA05-58F (manual p.14)
- Wall or roof termination (e.g. Napoleon GD422R-2 / ST58U-1 wall, GD410 / GD411 / GD412 roof, GD401 periscope)
- Propane installs: rigid vent only (manual pp.25-26)
- Non-combustible finishing material (not supplied, manual p.54)
Optional accessories
- 4-piece finishing trim
- Heat management kits DHC and DHM (reduce clearances; for TVs above)
- Napoleon flex vent kits GD420 (5 ft) / GD430 (10 ft), natural gas only
Downloads
Product video
Installation and safety notes
⚠ Important: Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This fireplace must be installed and serviced by a qualified professional following Napoleon's installation manual. The glass gets very hot, so keep children, pets and furniture away and always use the safety barrier.
Product and safety information (pp.5-11)
- Install and service by a qualified installer, service agency or gas supplier; in Massachusetts a licensed plumber or gas fitter (p.9).
- Never run the fireplace without the safety barrier; the glass door is a pressure-relief device, so keep the area around it clear (pp.5, 53, 58).
- Certified to CSA 2.22 / ANSI Z21.50; approved for bedrooms, bathrooms and bed-sitting rooms; mobile home certified per 24 CFR Part 3280 / CSA Z240 MH (pp.5, 10-11).
- On carpet, vinyl tile or other combustible flooring (other than wood), install on a metal or wood panel the full width and depth (p.9).
- Above 4,500 ft, reduce input 4% for every 1,000 ft unless the local authority says otherwise (p.5).
- Remote takes 3 AAA batteries; wall switch takes 4 AA (p.5).
Dimensions and framing (pp.12-13, 27-31)
- Framing width 77 13/16" (1976 mm); framing dimension E 16 3/16".
- 0" clearance to back and side standoffs and to the floor; 3" top / 2" sides outside the enclosure for horizontal venting; 6" inside the enclosure above the vent pipe.
- Do not screw into the restricted area of the appliance; fasteners may not penetrate more than 3/4" (p.53).
Venting (pp.14-26, 32-39)
- 5" exhaust / 8" intake direct vent from Wolf Steel, Metal-Fab, BDM, Simpson DuraVent or Selkirk; never mix brands (p.14).
- Horizontal run up to 20 ft; vertical up to 40 ft; minimum practical rise 6 ft; air terminal at least 16" above the roof (pp.15-22).
- Up to three 90° elbows in the example layouts; two 45° count as one 90° (pp.20-21).
- Flexible vent (GD420/GD430) allowed on natural gas; propane is rigid only (pp.25-26).
- Vertical runs may need the restrictor (3 positions for 62/74 models; not recommended for short vertical runs) (p.38).
Electrical (pp.40-44)
- 115 V, 60 Hz, under 12 A; hard-wire and ground the appliance when it is permanently framed in (p.40).
- Wire to NEC ANSI/NFPA 70 or CSA C22.1; do not connect 110 V to the control valve or wall switch (pp.2, 40-42).
- Battery holder lets the fireplace operate during a power failure; set the switch to the middle position (p.5).
Gas (pp.45-47)
- Use the gas type on the rating plate; conversion only with a certified Napoleon kit (p.5).
- NG inlet 4.5"-7" w.c. (13" max), manifold 3.5"; LP inlet 11"-13", manifold 10" (p.6).
- Pilot-on-demand and split-flow burner operation are explained on pp.46-47.
Finishing (pp.48-62)
- Non-combustible finishing in the 15 5/8" zone above and 7" each side of the opening (p.53).
- Protrusions up to 4"; add 2" clearance per extra inch (p.54).
- Mantel: the required height above the opening increases with mantel depth (p.56). TV above without a heat management kit: at least 6" from the top of the finishing flange to the bottom of the TV, and at least 2.5" between a mantel and the bottom of the TV (p.57).
- Place logs exactly as shown; keep media off the pilot and burner ports and use only the supplied amount (pp.60-62).
Maintenance (pp.65-71)
- Have the fireplace inspected and serviced by a qualified technician; colours of logs and embers settle during the first burns (p.62).
- Never run with cracked, scratched or missing glass (p.58).
Building code information (pp.9-11, 40, 45)
- US: local codes, or the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
- Canada: CSA B149.1 Natural Gas and Propane Installation Code and CSA C22.1 Canadian Electrical Code (CSA Group).
- Electrical (US): National Electrical Code, ANSI/NFPA 70.
- Manufactured homes: HUD 24 CFR Part 3280 (or ANSI/NFPA 501A where it does not apply); Canada CAN/CSA Z240 MH.
- Massachusetts: licensed plumber or gas fitter, T-handle gas shutoff, flexible connector max 36", CO detector required (p.9).
Warranty
- Napoleon President's Limited Lifetime Warranty (Napoleon Tall Linear Vector Series with Luminous Logs installation manual W415-4127, section 16.0, pp.82-83).
- Lifetime, for as long as the original purchaser owns it: combustion chamber, heat exchanger, stainless/steel burner, logs and embers, rocks, ceramic glass (thermal breakage only) and gold-plated parts against tarnishing.
- Electrical (110 V and millivolt) components and wearable parts (blowers, gas valves, thermal switches, switches, wiring, remote controls, ignitors, gaskets, pilot assemblies): free replacement in year one.
- Labour for warranty repairs: covered in year one (gas log sets excluded).
- After year one the warranty is parts-only per the manual; from 10 years to life Napoleon supplies replacement parts at 50% of current retail.
- Who is covered: the original purchaser, bought through an authorized Napoleon dealer; non-transferable; starts at original installation. Registration is not required, but keep proof of purchase with the model and serial number.
- Conditions: installed by a licensed, authorized technician or contractor following the manual and local and national codes.
- Key exclusions: misuse, poor maintenance, accidents, alteration, other manufacturers' parts, heat or chemical discolouration, overfiring, downdrafts or venting conditions, water or weather damage, and travel, diagnostic and shipping charges.
California Proposition 65
WARNING: This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Frequently asked questions — TLV62LN2
What size framing does the TLV62LN2 need?
The framing is 77 13/16" wide and 16 3/16" deep for this see-through model, with a minimum enclosure or ceiling height of 91" measured from the bottom of the fireplace. It can sit directly on the floor.
What venting does it use, and how far can it run?
It uses 5" x 8" direct vent pipe from Wolf Steel, Metal-Fab, BDM, Simpson DuraVent or Selkirk, without mixing brands. Horizontal runs go up to 20 ft and vertical runs up to 40 ft. Flexible vent is allowed on natural gas; propane installs use rigid vent only.
Can the TLV62LN2 be converted to propane?
Yes, with a certified Napoleon conversion kit. On propane it is rated 38,000 BTU/h maximum and 21,000 BTU/h minimum, compared with 44,000 and 25,000 BTU/h on natural gas.
Does it work in a power outage?
Yes. The battery back-up control system keeps the fireplace running during a power failure.
Is a remote included?
Yes. A remote control comes with the fireplace, and it also works with Napoleon's eFIRE app on your phone.
What's the warranty?
Napoleon's President's Limited Lifetime Warranty covers the combustion chamber, heat exchanger, burner, logs and embers, rocks and ceramic glass (thermal breakage) for life. Electrical components, wearable parts and labour are covered for the first year.
Loading component details…
Add to cart to see your price.