Napoleon Luxuria 62 Direct Vent Gas Fireplace LVX62NX-1

SKU / Model: LVX62NX-1

Free Fast Shipping
In-stock items are processed in 1–2 business days.

$13,749.00

Black Friday Savings applied in your cart

YOUR SPECIAL OFFER IS AVAILABLE

This product qualifies for an exclusive special offer.

Complete your selections and add this product to your cart to unlock the eligible offer.

Offer eligibility and final promotional pricing are confirmed in the cart. Accessories qualify separately. Offers may change.

Product overview

The Napoleon Luxuria 62 (LVX62NX-1) is a built-in, direct vent natural gas linear fireplace with a 66 1/8" wide, unobstructed viewing area. It is a single-sided model designed for feature walls, media walls and great rooms. Napoleon designed the Luxuria around safe placement of TVs and art above the fireplace, which makes it one of the most practical large linear fireplaces for modern homes.

The Divinity flame pattern rises from a tube-style burner across the full width of the firebox. Choose Oak, Driftwood or Birch high-definition log sets, or optional glass media and media enhancement kits, to set the look. MIRRO-FLAME porcelain reflective radiant panels multiply the flame, and an ember bed with multi-coloured LED lights plus the NIGHT LIGHT system lets the fireplace glow even when the flame is off.

Gas input on natural gas is up to 44,000 BTU/h with a turn-down to 32,000 BTU/h (the propane model is rated 35,000 to 28,000 BTU/h). Napoleon's patented Dynamic Heat Control is included: it moves heat away from the wall above the fireplace and out into the room through a vented enclosure, which lowers wall temperatures, lets combustible framing and finishes come right up to the opening in most configurations, and needs no extra fans, ducts or wiring.

The included premium safety barrier is a safe-to-touch, triple-paned glass guard system, so the front stays cool enough for homes with children and pets. The eFIRE controller and remote control are included, and the fireplace can be run from the eFIRE app on your phone. A battery back-up control system keeps it working during a power outage.

The Luxuria vents through 5" x 8" direct vent pipe from Wolf Steel, Metal-Fab, BDM, Simpson DuraVent or Selkirk, with horizontal runs up to 20 ft and vertical runs up to 40 ft, and approved flexible venting is allowed. An optional indoor/outdoor kit is available. Compared with Napoleon's Vector series, the Luxuria adds Dynamic Heat Control and the cool-touch glass guard as standard; compared with the Tall Bay Luxuria it has a lower, wider opening. It is built in Ontario, Canada, and covered by Napoleon's President's Limited Lifetime Warranty.

Key features

  • Up to 44,000 BTU/h: natural gas input; turn-down to 32,000 BTU/h
  • Premium safety barrier included: safe-to-touch, triple-paned glass guard system
  • Tube-style burner
  • Divinity flame pattern: a tall, lively flame across the full width
  • Dynamic Heat Control included: moves heat away from the wall above; combustible finishes up to the opening in most configurations (manual p.9)
  • Designed for TVs: reduced temperatures above the opening for a TV, soundbar or artwork
  • Oak, Driftwood or Birch high-definition log sets: choose your media in the configurator
  • Optional media enhancement kits
  • Optional glass media
  • MIRRO-FLAME porcelain reflective radiant panels included
  • Ember bed with multi-coloured LED lights
  • NIGHT LIGHT system: ambient glow with the flame off
  • eFIRE controller and remote control included: also works with the eFIRE mobile app
  • ProFlame II electronic ignition with pilot-on-demand: manual pp.52-53
  • Battery back-up control system: operates during a power failure (manual p.45)
  • Flame and heat adjustment
  • Easy-access air control
  • Firestop / vent shield: firestop spacer assembly W010-4178 supplied (manual p.38)
  • Stainless steel flex connector
  • Optional indoor/outdoor kit
  • Optional heat management grill and trim kits: decorative trim/grill kit for the DHC air outlet (manual p.65)
  • Single-sided design: for feature walls and media walls
  • Approved for bedrooms, bathrooms and bed-sitting rooms; mobile home certified: manual pp.5, 12
  • Certified to CSA 2.22 / ANSI Z21.50: vented decorative gas appliance
  • Made in Ontario, Canada
  • President's Limited Lifetime Warranty

Specifications

Model LVX62NX-1 (natural gas, electronic ignition)
Unit dimensions 77 5/16" W cabinet (81 5/16" W including side flanges) × 32 3/4" H cabinet (41 3/16" H including top stand-offs) × 17 11/16" D (manual pp.13-14)
Framing dimensions 77 13/16" (197.6 cm) W × 39 15/16" (101.4 cm) H × 18" (45.7 cm) D (21" / 53.5 cm maximum depth); minimum enclosure height 91" (231.1 cm) measured from the bottom of the appliance, kept unobstructed (manual pp.55-58, spec sheet)
Viewing area 66 1/8" W × 18 5/8" H
Clearances to combustibles Stand-offs and base: 0"; inside the enclosure: 6" (152 mm) minimum, including 6" at the top for horizontal vent; vertical vent: 1" (25 mm) all round; outside the enclosure: 3" (76 mm) top, 2" (51 mm) sides and bottom; non-combustible finishing such as brick or stone: 0"; TVs, frames and wall decor: at least 6" below the air outlet and 6" above the finishing flange; combustible mantel: up to 4" projection at 0" from the projection to the finishing flange, deeper mantels must sit higher above the opening (manual pp.35-36, 63-64)
Fuel Natural gas (propane is a separate model)
Gas input, natural gas 44,000 BTU/h max / 32,000 BTU/h min (manual p.6)
Gas input, propane model 35,000 BTU/h max / 28,000 BTU/h min (manual p.6)
Inlet gas pressure NG 4.5" w.c. min, 7" w.c. max; LP 11" min, 13" max; never above 13" w.c. (manual p.6)
Manifold pressure NG 3.5" w.c.; LP 10" w.c. (manual p.6)
Electrical 115 V, 60 Hz, less than 12 A; hard-wire the junction box when framed in (manual pp.11, 45)
Venting Direct vent, 5" exhaust / 8" intake (manual p.15)
Viewing Single-sided
High altitude Above 4,500 ft reduce input 4% per 1,000 ft (manual p.5)

BTU figures are gas input ratings, not delivered heat output.

Dimensions and clearances

  • Dynamic Heat Control air outlet (front or rear opening): at least 160 sq in free area, outlet height (Q) 2" to 3", centred and no more than 1 1/2" below the top of the enclosure (manual pp.30-31)
  • Non-combustible protrusions up to 4" (10 cm); for each extra 1" of projection add 2" of side and top clearance (manual p.63)
  • Recessed installs (single-sided): recess (M) 3" (76 mm), up to 4" max with a protrusion; recess facing must be non-combustible (manual pp.56, 62)

What's included

  • Premium safety barrier: safe-to-touch triple-paned glass guard (GGA-1)
  • Dynamic Heat Control system
  • eFIRE controller and remote control (3 AAA)
  • Battery holder / wall switch (4 AA)
  • MIRRO-FLAME porcelain reflective radiant panels
  • Ember bed multi-coloured LED lights and NIGHT LIGHT system
  • Stainless steel flex connector
  • Firestop spacer assembly W010-4178 (wall passage)
  • Lifting handles and hardware kit (manual p.12)

Required components

  • Media: choose an Oak, Driftwood or Birch high-definition log set, or glass media, in the configurator
  • 5" x 8" direct vent system from one approved manufacturer: Wolf Steel, Metal-Fab SureSeal, BDM Pro-Form, Simpson DuraVent DirectVent Pro or Selkirk Direct Temp; never mix brands or combine rigid and flex (manual p.15)
  • Matching starter adapter where required: Metal-Fab 5NDA, DuraVent W175-0170, Selkirk 5DT-AAN, Olympia Ventis VDV-NA05-58F (manual p.15)
  • Wall or roof termination for the chosen vent system
  • Ceiling firestop W500-0028 for vertical runs through a ceiling (not supplied)
  • Ventilated enclosure built to the Dynamic Heat Control planning options (manual pp.27-32)
  • Propane installs: vertical termination only (manual pp.25-26)

Optional accessories

  • Media enhancement kits
  • Glass media
  • Indoor/outdoor kit
  • Decorative trim/grill kit for the Dynamic Heat Control air outlet (front or rear)
  • Dynamic Heat Management front grill kits

Downloads

Product video

Installation and safety notes

⚠ Important: Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This fireplace must be installed and serviced by a qualified professional following Napoleon's installation manual. Keep children, pets, furniture and decor clear of the fireplace and the heat outlet, and always keep the glass guard in place.

General information (pp.5-12)

  • Install and service by a qualified installer, service agency or gas supplier; in Massachusetts a licensed plumber or gas fitter (p.5).
  • Never run the fireplace without the safety barrier / glass guard installed (pp.5, 7).
  • Certified to CSA 2.22 / ANSI Z21.50; approved for bathrooms, bedrooms and bed-sitting rooms; mobile home certified to 24 CFR Part 3280 / CAN/CSA Z240 MH (pp.5, 12).
  • Ratings: 44,000 / 32,000 BTU/h natural gas; propane model 35,000 / 28,000 BTU/h (p.6).
  • Above 4,500 ft, reduce input 4% for every 1,000 ft unless the local authority says otherwise (p.5).
  • Dynamic Heat Control needs a ventilated enclosure with a minimum opening area at a set height and position (p.9).

Dimensions (pp.13-14)

  • Finishing flange opening 66 1/8"; cabinet width 77 5/16"; width with flanges 81 5/16"; height 41 3/16".
  • Never extend framing or finishing materials inside the finishing flange (p.13).

Venting requirements (pp.15-26)

  • 5" exhaust / 8" intake from Wolf Steel, Metal-Fab, BDM, Simpson DuraVent or Selkirk Direct Temp only; do not mix brands or combine rigid and flexible pipe (p.15).
  • Horizontal run up to 20 ft; vertical up to 40 ft; practical minimum vertical rise 6 ft (pp.15-18).
  • Flexible vent: up to two connections horizontal or three vertical; keep the liner taut; pipe marked "Wolf Steel Approved Venting" or "E2" (pp.16, 41).
  • Roof terminal at least 16" above the highest roof penetration point (pp.19, 42).
  • Propane: vertical termination only, horizontal portion no more than 52 1/2" (pp.25-26).
  • Two 45° elbows count as one 90° (pp.25-26).

Installation planning and framing (pp.27-37)

  • Four enclosure options: open enclosure, front opening, rear opening, open enclosure with hard combustible valance; front/rear openings need at least 160 sq in free area (pp.27-32).
  • Rear openings need direct air communication with the next room, or airflow can reverse and overheat (p.31).
  • Minimum framing width 77 13/16" (197.6 cm); minimum enclosure height 91" (231.1 cm); framing depth 18" (21" max) (pp.34, 55-58).
  • 0" to standoffs and base; 6" inside the enclosure; 3" top and 2" sides outside; 1" around vertical vent (pp.35-36).
  • The enclosure must be finished on all four sides with a complete floor; extra air inlets are not acceptable (p.61).

Venting installation (pp.38-44)

  • Firestop spacer W010-4178 is supplied for wall passages; ceiling firestop W500-0028 is not supplied (p.38).
  • Vertical installs may need restricting if the flame is too active (pp.43, 78).
  • Install the vent shield as shown (p.44).

Electrical (pp.45-50)

  • Hard-wire and ground the junction box when the fireplace is permanently framed in (p.45).
  • Mount the battery holder/switch in a standard switch box within 8 ft of the side of the appliance (p.46).
  • Do not wire 110 V to the valve or wall switch; do not remove the grounding prong (p.45).
  • Keep wiring at least 22" from the centre of the vent pipe (p.59).

Gas (p.51)

  • 1/2" gas supply with the flex connector (3/8" without) (p.51).
  • Disconnect the fireplace before pressure-testing the line above 1/2 psig (p.51).
  • Leak-test with a sniffer, leak fluid or soap solution, never a flame (p.51).

Finishing (pp.54-77)

  • Combustible finishes are allowed with Dynamic Heat Control except in recessed installs; keep the air outlet out of reach and unobstructed (p.62).
  • No fastener may penetrate the appliance more than 3/4" (p.60).
  • Fit the glass guard before finish framing, then remove and store it during finishing; it takes two people (p.66).
  • Use only the supplied amount of media, keep it off the burner ports and out of the pilot area, and check ignition across the burner (p.77).

Maintenance (pp.80-85)

  • Annual service by a qualified technician: clean, replace batteries, inspect vent, burner, media, gaskets and relief system, and leak-test (p.81).
  • Let the firebox cool before service; never vacuum hot embers (p.81).

Building code information (pp.5, 45, 51)

Warranty

  • Napoleon President's Limited Lifetime Warranty (Luxuria installation manual W415-2035, section 17.0, p.93).
  • Lifetime, for as long as the original purchaser owns it: combustion chamber, heat exchanger, steel burner, PHAZER logs and embers, rocks, ceramic glass (thermal breakage only), gold-plated parts (tarnishing), porcelain enamel and aluminum trim.
  • Electrical (110 V and millivolt) components and wearable parts: free replacement in the first year.
  • Labour for warranty repairs: covered in the first year with Napoleon's prior approval (gas log sets excluded).
  • Years 1 to 10: Napoleon repairs or replaces defective lifetime-covered parts at its discretion; from 10 years to life, replacement parts at 50% of current retail.
  • Who is covered: the original purchaser, bought through an authorized Napoleon dealer; non-transferable.
  • Conditions: installed by a licensed, authorized installer following the manual and all applicable codes, and operated normally.
  • Key exclusions: misuse, lack of maintenance, accidents, alteration, third-party parts; scratches, dents, corrosion or discolouration from heat or cleaners; porcelain chipping; mechanical breakage of PHAZER logs; overfiring, downdrafts, negative pressure and venting conditions; water or weather damage; shipping, travel and diagnostic charges.

California Proposition 65

WARNING: This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

Flames and flame colors on the website may appear differently in real life.

Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.

Frequently asked questions — LVX62NX-1

What size framing does the LVX62NX-1 need?

The framing is 77 13/16" wide, 39 15/16" high and 18" deep (21" maximum depth). The enclosure must be at least 91" tall measured from the bottom of the fireplace.

What venting does it use, and how far can it run?

It uses 5" x 8" direct vent pipe from Wolf Steel, Metal-Fab, BDM, Simpson DuraVent or Selkirk, never mixing brands or combining rigid and flexible pipe. Horizontal runs go up to 20 ft and vertical runs up to 40 ft.

Can a TV go above it?

Yes. The Luxuria is designed for a TV, soundbar or artwork above. Keep electronics and frames at least 6" above the finishing flange and at least 6" below the air outlet.

Does it work in a power outage?

Yes. The battery back-up control system keeps the fireplace running during a power failure.

Is a remote included?

Yes. The eFIRE controller and remote control come with the fireplace, and it also works with Napoleon's eFIRE app.

What's the warranty?

Napoleon's President's Limited Lifetime Warranty covers the combustion chamber, heat exchanger, burner, PHAZER logs and embers, rocks and ceramic glass (thermal breakage) for life. Electrical components, wearable parts and labour are covered for the first year.

Loading component details…

Add to cart to see your price.

Call for best price

Similar Products