Napoleon Galaxy 62 Outdoor Gas Fireplace GSS62NE
SKU / Model: GSS62NE
Fireplace only$5,139.00
Black Friday Savings applied in your cart
Unlock an exclusive offer on this product.
Product overview
The Napoleon Galaxy 62 (GSS62NE) is a built-in outdoor natural gas fireplace for patios, covered porches, outdoor kitchens and backyard living spaces. Its 304 stainless steel firebox is 66 9/16" wide, 40 1/8" high and 15 15/16" deep, and it builds into a combustible-framed outdoor enclosure behind a finishing flange, with a gas inlet on either side.
A 62 1/16" x 20" opening shows a long, linear ribbon of flame over the clear glass embers that come in the box. Coloured glass embers and beads, the Woodland media kit, High Definition Birch, Oak or Driftwood log sets and MIRRO-FLAME black porcelain panels change the look, and built-in lights add a glow after dark.
Maximum input is 60,000 BTU/h. Electronic ignition runs from the supplied wall-mount switch, so there is no pilot to light by hand. Options include an outdoor timer kit (GSOTK), a heat and exhaust management kit (GSOHEM) and a see-through conversion kit (GSS62STC, ordered with the fireplace). It suits covered outdoor rooms that keep at least 30% of the perimeter permanently open, and carries Napoleon's 5 year limited warranty on stainless steel components.
Key features
- 60,000 BTU/h natural gas input: installation manual p.8
- 304 stainless steel construction: built for durable outdoor use
- Clear glass embers included: optional glass embers and beads in six colours
- Optional High Definition log sets: Birch, Oak or Driftwood
- Optional Woodland media kit: WLKL: rocks, glowing embers, charcoal, shale, glass and vermiculite
- Optional MIRRO-FLAME porcelain panels: reflective black panels that multiply the flame
- Integrated lights: fireplace and lights run from the same control
- External wall-mount control switch: supplied with a 20 ft wire (manual p.23)
- Electronic ignition: lights the pilot automatically; no manual lighting
- Finishing flange and nailing tabs: for a clean built-in finish
- Glass wind guard: helps keep the flame steady outdoors (manual p.29)
- Hot-glass safety barrier: premium safety mesh W565-10000573
- See-through conversion kit: GSS62STC, must be chosen at purchase
- Optional outdoor timer kit: GSOTK
- Optional heat and exhaust management kit: GSOHEM
- Optional premium screen kit: GSS62SK, 1" stainless steel surround
- Optional brushed stainless steel cover: GSS62WC, protects the unit when not in use
- Two gas inlet locations: one on either side of the firebox
- Propane conversion available: kit W175-10003379
- Certified to ANSI Z21.97 / CSA 2.41: outdoor decorative gas appliance
- 5 year limited warranty
Specifications
| Model | GSS62NE (natural gas, electronic ignition) |
|---|---|
| Unit dimensions | 66 9/16" W x 40 1/8" H x 15 15/16" D; 17 1/2" overall depth (manual p.10) |
| Framing dimensions | Minimum framing 67" (1702 mm) wide x 40 1/2" (1029 mm) high x 17" (432 mm) deep, or 15 15/16" (405 mm) deep with the see-through kit; enclosure top at least 72" (1829 mm) above the appliance bottom, 84" (2134 mm) with a TV recess (manual pp.16-18, 20) |
| Viewing area | 62 1/16" W x 20" H fireplace opening, set by the finishing flange (manual p.10) |
| Clearances to combustibles | Framing 0" to the stand-offs (sides only), with a combustible header at the top and combustible studs at both sides; combustible finishing 1" (25 mm) to the back (0" with the see-through kit) and 1/4" (6 mm) to the sides; non-combustible finishing 14" (356 mm) above the opening and 3 1/4" (83 mm) at the sides when finishing over the front face; side wall at least 6" (152 mm) from the appliance; non-combustible facing may project up to 4" (102 mm) from the opening face, with 2" (51 mm) more clearance at the sides and top for every extra 1"; combustible mantel, measured up from the line Napoleon marks as the top of the appliance, 28 1/8" above the appliance base: 10" above for a 2" deep mantel, 12" for 4", 14" for 6", 16" for 8" and 18" for 10"; with the premium screen kit 20", 22", 24", 26" and 28"; ceiling at least 72" (1829 mm) above the appliance bottom; keep the space around and above the appliance clear and keep objects at least 48" (121.9 cm) from the front (manual pp.9, 16, 21-22) |
| Fuel | Natural gas; propane with conversion kit W175-10003379 (manual p.39) |
| Gas input | 60,000 BTU/h (manual p.8) |
| Orifice | NG #26, LP #44 (manual p.37) |
| Inlet gas pressure | Minimum NG 5.5" (14 mb) w.c., LP 11" (27 mb) w.c.; maximum 13" (32 mb) w.c. (manual p.8) |
| Manifold pressure | NG 3.5" w.c.; LP 10" w.c. (manual p.8) |
| Electrical | 120 V hard-wired, grounded; 115 V, 60 Hz, under 12 A (manual pp.9, 24) |
| Ignition | Electronic, with external wall-mount switch |
| Venting | None required (outdoor appliance); optional heat and exhaust management kit GSOHEM |
| Construction | 304 stainless steel |
| Certification | ANSI Z21.97 / CSA 2.41 |
| High altitude | Above 4,500 ft reduce input 4% per 1,000 ft (manual p.6) |
Dimensions, BTU and pressures from the installation manual W415-10003415. BTU figures are gas input ratings, not delivered heat output.
Included components
- 304 stainless steel firebox with finishing flange
- Clear glass embers (manual p.29)
- Glass wind guard (manual p.29)
- Hot-glass safety barrier (premium safety mesh W565-10000573)
- Wall-mount control switch with 20 ft wire (manual p.23)
- 3 V AC adaptor W707-0002 (manual p.25)
- Nailing tabs (in the manual bag, manual p.21)
Required components
- Natural gas supply line with an accessible manual shut-off valve, sized and installed by a qualified gas fitter (manual section 7.0)
- Dedicated, grounded 120 V hard-wired electrical supply (manual p.24)
- Outdoor enclosure framed to the minimum framing and enclosure dimensions above, with non-combustible finish where required (manual section 5.0)
- For propane: conversion kit W175-10003379 installed by a qualified installer, and a correctly mounted and ventilated cylinder outside the structure (manual pp.26-27, 39)
Optional accessories
- See-through conversion kit GSS62STC (order with the fireplace)
- Outdoor timer kit GSOTK
- Prestige heat and exhaust management kit GSOHEM
- Premium screen kit GSS62SK (1" stainless steel surround)
- Brushed stainless steel cover GSS62WC
- High Definition log sets: Birch BLKTLV62, Oak OLKTLV62, Driftwood DLKTLV62
- MIRRO-FLAME porcelain panels PRPGS62; see-through panels PRPGSST
- Woodland media kit WLKL
- Glass embers MKGA / MKGK / MKGB / MKGC / MKGR / MKGT and glass beads MKBA / MKBK / MKBB / MKBC / MKBT
- Propane conversion kit W175-10003379 (LP to NG W175-10003380)
- Door handle N325-0049-SER
Downloads
Product video
Installation and safety notes
⚠ Important: Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This outdoor appliance must be installed and serviced by a qualified professional following Napoleon's installation manual, and it must never be installed indoors. The glass and surrounding surfaces get very hot, so keep children, pets, furniture and clothing well away.
General information (pp.6-9)
- Install and service by a qualified installer, service agency or gas supplier.
- Certified to ANSI Z21.97 / CSA 2.41 as an outdoor decorative gas appliance; for outdoor patio or yard use only, never inside a building or its warm air envelope (p.6).
- Rating: 60,000 BTU/h maximum input; minimum inlet pressure NG 5.5" w.c., LP 11" w.c.; maximum 13" w.c. (p.8).
- Above 4,500 ft reduce the input 4% for every 1,000 ft unless the local authority says otherwise (p.6).
- A sheltered spot is strongly recommended: direct wind causes an erratic flame and can put the burner out (p.6).
- The unit deflects some water but is not waterproof; protect logs from rain and snow.
Location (p.12)
- Allowed: an overhead cover with no more than two side walls; three walls with an overhead cover if at least 30% of the perimeter is permanently open; or walls on all sides with a permanent ground-level opening and no overhead cover.
- At least 30% of the outdoor living space perimeter must be open and unobstructed.
Heat and exhaust management venting, optional (pp.13-14)
- Used only with the optional GSOHEM kit: vertical rise 36" minimum to 40 ft maximum, support every 3 ft, 1" clearance to combustibles around the pipe.
- Terminate at least 24" above anything within 10 ft horizontally (p.13).
- Fireplace location clearances (p.14): 12" from opening windows or doors (24" with vinyl); 36" from an unventilated or ventilated soffit and 60" from a vinyl soffit or below electrical service; inside corner 6" (non-vinyl siding one side), 9" (non-vinyl alcove) or 48" (vinyl siding or windows); outside corner 6"; 36" from a service regulator vent outlet and either side of a gas meter or regulator; 12" from non-mechanical air supply or combustion air inlets; 72" in Canada or 36" in the USA from a mechanical air supply inlet or exhaust; 72" under a veranda, porch, deck, balcony or overhang and 72" from vinyl or composite, both measured from the appliance base.
Framing and clearances (pp.15-23)
- Minimum framing 67" (1702 mm) wide x 40 1/2" high x 17" deep; minimum enclosure height 72", 84" with a TV recess.
- Combustible framing to the stand-offs; non-combustible finish within 14" above the opening when finishing over the front face.
- Combustible mantels, measured up from the line Napoleon marks as the top of the appliance, 28 1/8" above the appliance base: 10" above for a 2" deep mantel, 12" for 4", 14" for 6", 16" for 8" and 18" for 10"; with the premium screen kit 20", 22", 24", 26" and 28" (p.22); mantels may get hot to the touch and need heat-resistant paint or lacquer.
- Mount the wall control switch with its 20 ft wire; never wire 120 V to the valve or wall switch (p.23).
Electrical (pp.24-25)
- Hard-wire to a grounded 120 V supply per local codes, CSA C22.1 or NFPA 70.
- A 3 V AC adaptor plugs into the junction box to power the controls (p.25).
Gas installation (pp.26-27)
- Use the gas type on the rating plate and leak-test every joint with soap solution, never a flame.
- Propane cylinders must meet DOT / CAN/CSA-B339, sit outside the structure, and any cylinder enclosure needs upper and lower vents (20 lb: 20 in² upper, 10 in² lower; 30 lb: 30 in² upper, 15 in² lower) and at least 2" clearance above ground (pp.26-27).
Operation (p.28)
- The ignition device lights the pilot automatically; never light it by hand.
- Check for gas smell around the unit and near the floor before lighting; the first firing may give off an odour for a few hours.
Finishing (pp.29-30)
- Install the glass wind guard, then spread the glass embers over the tray and burner; never run the fireplace without them.
- Keep embers off the ignition area; logs must not cover burner ports or the pilot housing (p.30).
Adjustments and maintenance (pp.31-34)
- A qualified technician sets the venturi and checks the pressures (pp.31-32).
- Turn off the gas and power before service; inspect before use and at least once a year, clean the burner, pilot and control compartment yearly; no abrasive cleaners on the glass (p.33).
Building code information
- US: local codes, or where none apply the latest National Fuel Gas Code, ANSI Z223.1/NFPA 54.
- Canada: CSA B149.1 Natural Gas and Propane Installation Code and CSA C22.1 Canadian Electrical Code (CSA Group).
- Electrical (US): National Electrical Code, ANSI/NFPA 70.
- Propane cylinders: US DOT specifications and CAN/CSA-B339 (manual p.26).
Warranty
- Napoleon 5 Year Limited Warranty (Galaxy installation manual W415-10003415, section 15.0, p.42).
- Stainless steel components: 5 years against defects.
- First year: defective parts repaired or replaced, with labour covered, when the unit has been installed and operated as instructed; electrical (110 V) components and wear parts such as gas valves, logs and gasketing are covered for the first year.
- After the first year: Napoleon may, at its discretion, refund the wholesale price of defective parts; labour and reinstallation are not covered.
- Who is covered: the original purchaser, at the original installation site in Canada or the USA; non-transferable; coverage starts on the date of original installation.
- Key exclusions: misuse, lack of maintenance, alterations, other makers' parts, damage from weather, prolonged dampness, condensation or harsh chemicals, heat or chemical damage to finishes; travel, diagnostic and shipping costs.
California Proposition 65
WARNING: This product can expose you to chemicals including lead and lead compounds, which are known to the State of California to cause cancer, and chemicals including BBP and DEHP, which are known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Frequently asked questions — GSS62NE
What size framing does the GSS62 need?
Minimum framing is 67" wide x 40 1/2" high x 17" deep, or 15 15/16" deep with the see-through kit. The top of the enclosure must be at least 72" above the bottom of the appliance, or 84" with a TV recess, and framing may meet the stand-offs at the sides.
Does it need a vent?
No. It is an outdoor decorative gas appliance with no vent required. The optional GSOHEM heat and exhaust management kit adds a vertical vent of 36" to 40 ft, with 1" clearance to combustibles around the pipe.
Can it be installed under a covered patio?
Yes. Napoleon allows an overhead cover with no more than two side walls, three walls with an overhead cover when at least 30% of the perimeter is permanently open, or walls on all sides with a permanent ground-level opening and no overhead cover. It must never be installed indoors.
Can it be converted to propane?
Yes. NG to LP conversion kit W175-10003379 (LP to NG W175-10003380) is fitted by a qualified installer. Maximum input is 60,000 BTU/h on either gas.
Can a TV go above it, and how high must a mantel be?
A TV recess needs an enclosure at least 84" high. Napoleon states that TV temperatures must be validated at installation and recommends the optional GSOHEM kit with a TV above. Combustible mantels are measured up from the line Napoleon marks as the top of the appliance, 28 1/8" above the appliance base: 10" above for a 2" deep mantel, 12" for 4", 14" for 6", 16" for 8" and 18" for 10"; with the premium screen kit 20", 22", 24", 26" and 28".
What is the warranty?
Napoleon's 5 Year Limited Warranty: stainless steel components for 5 years; electrical components, wear parts and labour in the first year. It covers the original purchaser at the original installation site in Canada or the USA and is not transferable.