Napoleon Havelock Elite Direct Vent Stove GDS50N-2

SKU / Model: GDS50N-2

Free Fast Shipping
In-stock items are processed in 1–2 business days.

$4,829.00

Black Friday Savings applied in your cart

YOUR SPECIAL OFFER IS AVAILABLE

This product qualifies for an exclusive special offer.

Complete your selections and add this product to your cart to unlock the eligible offer.

Offer eligibility and final promotional pricing are confirmed in the cart. Accessories qualify separately. Offers may change.

Product overview

The Napoleon Havelock Elite (GDS50N-2) is a traditional cast-look direct vent gas stove rated up to 40,000 BTU/h on natural gas. It suits large living rooms, great rooms, cottages and open-plan spaces, and it is approved for bedrooms, bathrooms and mobile homes. It vents through the top with 4" / 7" direct vent pipe, up to 20 ft horizontally or 40 ft vertically, or into an existing masonry chimney with a co-linear liner.

The look is classic Napoleon: square glass doors with a magnetic handle, realistic oak logs with glowing embers, and MIRRO-FLAME porcelain reflective panels that make the fire look deeper. Choose the PDGDS50 pedestal or FTGDS50 stove feet (one base is required), or add the optional ARCHGDS50 arched door.

Heat comes from Napoleon's heat exchanger, heat-radiating ceramic glass and a built-in blower, with a split-flow burner that turns down 50% for milder days and up to 74.3% efficiency (propane, CSA P.4.1-15). The included full-function remote runs the thermostat, flame height and blower, and the battery back-up keeps the stove working in a power failure. It is backed by the President's Limited Lifetime Warranty.

Key features

  • Up to 40,000 BTU/h: natural gas maximum input; propane 39,000 BTU/h (manual p.8)
  • Up to 74.3% efficiency: propane model, CSA P.4.1-15 (Napoleon)
  • Proven heat exchanger technology: captures and radiates heat for whole-room warmth
  • Split-flow burner: 50% turn-down for milder days
  • Built-in blower: thermally activated; starts 15-30 minutes after lighting (manual p.53)
  • Heat-radiating ceramic glass
  • Realistic oak logs and embers included: PHAZER logs (manual p.41)
  • MIRRO-FLAME porcelain reflective panels included
  • Full-function remote included: thermostat, flame height, blower and more
  • Pilot on demand: intermittent pilot with continuous pilot mode and 7-day timer (manual p.48)
  • Battery back-up control system: keeps the stove working in a power failure (manual p.45)
  • Pedestal or feet base: one base required: PDGDS50 pedestal or FTGDS50 feet
  • Square glass doors included: optional ARCHGDS50 arched glass door
  • Magnetic door handle included
  • Premium safety barrier included: must be installed (manual p.40)
  • 100% SAFE GUARD gas control system
  • Firestop included
  • Top venting, 4" / 7" direct vent: co-linear liner option for masonry chimneys (manual p.26)
  • Approved for bedrooms, bathrooms and mobile homes: manual p.7
  • Field convertible to propane: with kit W175-10011046 (2026 price book)
  • President's Limited Lifetime Warranty: manual p.65

Specifications

Model GDS50N-2 (natural gas, electronic ignition; manual covers GDS50-2NE / PE)
Unit dimensions 28 1/2" W x 34 3/4" H x 21 1/2" D (spec sheet W415-10011201)
Framing dimensions None required (freestanding stove); over carpet, vinyl tile or other combustible flooring other than wood, install on a metal or wood panel the full width and depth of the stove (manual pp.9, 27)
Viewing area 20 3/4" x 12 3/4" (Napoleon)
Clearances to combustibles Side wall 7 in. (178 mm) (A); back wall 2 in. (51 mm) (B); corner installation 2 in. (51 mm) (C) and 10 in. (254 mm) (F); D 18 in. (457 mm) and E 5 in. (127 mm) as marked in the manual clearance figure; at least 20 in. (508 mm) from the top of the stove to the ceiling; at 1 in. from the wall the blower switch, on-off switch and blower power cord may be hard to reach; vent pipe 2 in. at the top and 1 in. at the bottom and sides on horizontal runs, 1 in. all round on vertical runs; keep furniture and other objects at least 48 in. (1.22 m) from the front (manual pp.2, 8, 28)
Max input NG 40,000 BTU/h; LP 39,000 BTU/h (manual p.8)
Max steady-state output NG 39,071 BTU/h; LP 36,889 BTU/h (manual p.8)
Efficiency up to 74.3% (propane, CSA P.4.1-15; Napoleon)
Inlet gas pressure NG 4.5" w.c. min, 7" w.c. max; LP 11" min, 13" max (manual p.8)
Manifold pressure NG 3.5" w.c.; LP 10" w.c. (manual p.8)
Electrical 115 V, 60 Hz, under 12 A; battery back-up (manual pp.10, 45)
Venting Direct vent, 4" exhaust / 7" intake, top vent (manual p.13)
Base Pedestal PDGDS50 or feet FTGDS50 (required, sold separately)
Ignition Electronic, pilot on demand (IPI / CPI), remote control
High altitude 2,000-4,500 ft: 10% derate with certified kit; above 4,500 ft reduce 4% per 1,000 ft (manual p.7)
Certification CSA 2.33 / ANSI Z21.88 vented gas fireplace heater (manual cover)

BTU figures are gas input ratings unless stated as output.

Included components

  • Havelock Elite stove body with heat exchanger and built-in blower
  • Square glass doors with heat-radiating ceramic glass
  • Oak log set, embers and charcoal (manual pp.41-44)
  • MIRRO-FLAME porcelain reflective panels
  • Premium safety barrier (manual p.40)
  • Magnetic door handle (manual p.12)
  • Full-function remote control
  • Battery back-up holder (manual p.45)
  • Firestop
  • Vent insulation sleeve (manual p.16)

Required components

  • Base, choose one: PDGDS50 pedestal or FTGDS50 stove feet (mandatory per the 2026 price book)
  • 4" / 7" direct vent system from one approved manufacturer: Wolf Steel, Metal-Fab, BDM, Simpson DuraVent, Selkirk Direct Temp or ICC (manual p.13)
  • Wolf Steel terminations: GD-222R round wall terminal (the only approved wall terminal), GD-110 / GD-111 / GD-112 roof terminals, GD-180 periscope (manual pp.13-14)
  • Starter adapter for third-party vent: DuraVent GDS924N, Amerivent 4DSC-N2, Selkirk Direct Temp 4DT-AAN, Metal-Fab Super Seal 4DNA, ICC EXCELDirect or Ventis VDV-NA04-47F (manual p.14)
  • Floor panel where installed over carpet or vinyl (manual p.9)
  • High-altitude kit for installations from 2,000 to 4,500 ft (manual p.7)

Optional accessories

  • ARCHGDS50 arched glass door
  • W361-0239-BULK ambient-glow embers
  • W660-0160 wall mount control
  • W175-10011046 natural gas to propane conversion kit
  • Co-linear chimney kit: 3" aluminium liner (10 to 40 ft) with Simpson DuraVent or Selkirk co-linear to co-axial adapters (manual p.26)

Downloads

Installation and safety notes

⚠ Important: Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This appliance must be installed and serviced by a qualified installer, service agency or gas supplier. The glass gets very hot, so keep children, pets and furniture away and always use the safety barrier.

General information (manual pp.7-12)

  • Install and service by a qualified installer, service agency or gas supplier.
  • Certified as a vented gas fireplace heater (CSA 2.33 / ANSI Z21.88); approved for bathrooms, bedrooms and bed-sitting rooms, and for mobile homes when secured through the base (pp.7, 10). In Massachusetts, bedroom and bathroom installs need a sealed direct vent unit (p.9).
  • Ratings: NG 40,000 BTU/h, LP 39,000 BTU/h maximum input (p.8).
  • High altitude: 10% derate with the certified kit from 2,000 to 4,500 ft; above 4,500 ft reduce input 4% per 1,000 ft (p.7).
  • Do not operate below 32°F (0°C), and never run it with the glass removed (p.2).

Venting (manual pp.13-26)

  • 4" / 7" vent from one approved manufacturer; never mix brands. Support the vent every 3 ft (p.13).
  • Up to 20 ft horizontal and 40 ft vertical; at most two horizontal or three vertical flex connections; 1/4" per foot rise on horizontal flex runs (p.14).
  • Wall terminal: GD-222R round terminal only. Periscope: bottom air slot at least 12" above grade, 8 ft maximum on a stove (pp.13, 16).
  • Terminal clearances include 12" above grade, 9" (US) from opening windows, 3 ft (US) from a mechanical air inlet, 16" above the roof and 7 ft above a paved sidewalk or driveway (pp.17-18).
  • Masonry chimney: 3" co-linear aluminium liner, 10 to 40 ft, with approved co-linear to co-axial adapters (p.26).

Installation (manual pp.27-33)

  • Fit the pedestal or legs first; secure the base when installing in a mobile home (pp.10, 28).
  • Keep 7" to a side wall, 2" to the back wall, 2" and 10" in a corner installation, and at least 20" from the top of the stove to the ceiling (p.28).
  • Seal vent joints with red high-temperature RTV (W573-0002) or Mill-Pac (W573-0007) (pp.27, 31-33).
  • Install on a metal or wood floor panel over carpet or vinyl (p.27).

Gas (manual p.39)

  • Use the gas type on the rating plate; inlet NG 4.5-7" w.c., LP 11-13" w.c.
  • Disconnect the stove from the supply when pressure-testing above 1/2 psig (p.2).
  • Leak-test all connections with soap solution, never a flame.

Electrical (manual pp.9, 45)

  • Plug the blower into a properly grounded receptacle; never remove the ground prong.
  • Never wire 110 V to the gas valve.
  • Fit batteries in the back-up holder so the stove runs in a power failure (p.45).

Finishing (manual pp.40-44)

  • Install the safety barrier and door; the barrier must always be in place (p.40).
  • Place the oak logs, embers and charcoal on the burner (pp.41-44).

Operation and maintenance (manual pp.46-54)

  • Keep furniture and combustibles at least 48" from the front (p.8).
  • Have the stove and venting inspected before first use and at least once a year: clean the burner, pilot, flame sensor and igniter, check gaskets and the relief system, replace batteries (pp.51-52).
  • Clean the glass after the first 4 hours of use with an ammonia-free, non-abrasive cleaner (p.54).
  • Fit a carbon monoxide detector (pp.3-4).

Building code information

Warranty

  • Napoleon President's Limited Lifetime Warranty (Havelock Elite installation and operation manual W415-10010378 B-0, section 11.0, pp.65-66).
  • Lifetime, for as long as the original purchaser owns it: combustion chamber, heat exchanger, steel burner, PHAZER logs and embers, rocks, ceramic glass (thermal breakage only), gold-plated parts (tarnish), porcelain enamel components and aluminum extrusion trim.
  • Electrical (110 V and millivolt) components and wear parts (blowers, gas valves, thermal switches, switches, wiring, remote controls, igniters, gaskets, pilot assemblies): replacement parts free in the first year.
  • Labour for warranty repairs: free in the first year, with prior approval through an authorized dealer, at Napoleon's set rate schedule (gas log sets excluded).
  • Years 1 to 10: defective lifetime-covered parts repaired or replaced free at Napoleon's discretion; from 10 years on, replacement parts at 50% of the current retail price.
  • Who is covered: the original purchaser, bought through an authorized Napoleon dealer and installed by a licensed, authorized technician per the instructions and local codes; non-transferable; starts at original installation; proof of purchase with model and serial number needed.
  • Key exclusions: misuse, neglect, lack of maintenance, accidents, alteration, other makers' parts, heat or chemical damage to finishes, chipped porcelain, mechanical breakage of PHAZER logs, overfiring, downdrafts, venting or negative-pressure problems, water, weather or condensation damage; shipping, travel and diagnostic charges.

California Proposition 65

WARNING: This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

Flames and flame colors on the website may appear differently in real life.

Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.

Frequently asked questions — GDS50N-2

How close can it go to a wall?

7 in. from a side wall and 2 in. from the back wall; in a corner installation 2 in. and 10 in. The top of the stove needs at least 20 in. to the ceiling, and furniture should stay at least 48 in. from the front. At 1 in. from the wall the blower and on-off switches may be hard to reach.

What venting does it use, and how far can it run?

4" / 7" direct vent pipe through the top of the stove, from one approved brand (never mixed): up to 20 ft horizontally through a wall or 40 ft vertically through the roof. The only approved wall terminal is the GD-222R, and it can also vent into an existing masonry chimney with a 3" co-linear aluminium liner 10 to 40 ft long.

Can it be converted to propane?

Yes, with Napoleon conversion kit W175-10011046. On propane it is rated 39,000 BTU/h maximum input.

Does it work in a power outage?

Yes. With batteries in the back-up holder the battery back-up control system keeps the stove working during a power failure.

Is a remote included?

Yes. A full-function remote is included and runs the thermostat, flame height, blower and more.

What is the warranty?

The Napoleon President's Limited Lifetime Warranty: lifetime coverage on the combustion chamber, heat exchanger, burner, PHAZER logs and other listed parts for the original purchaser, with electrical components, wear parts and labour covered in the first year.

Loading component details…

Add to cart to see your price.

Call for best price

Similar Products