Napoleon Haliburton Direct Vent Gas Stove GDS28

SKU / Model: GDS28-1NE

Free Fast Shipping
In-stock items are processed in 1–2 business days.

$3,749.00

Black Friday Savings applied in your cart

YOUR SPECIAL OFFER IS AVAILABLE

This product qualifies for an exclusive special offer.

Complete your selections and add this product to your cart to unlock the eligible offer.

Offer eligibility and final promotional pricing are confirmed in the cart. Accessories qualify separately. Offers may change.

Product overview

The Napoleon Haliburton (GDS28) is a compact cast-iron direct vent gas stove on a pedestal base, made for smaller rooms that still need serious heat. Its rounded traditional shape fits cottages, dens, bedrooms, basements and family rooms, and the brochure describes it as "compact design ideal for smaller spaces". The manual approves it for bedrooms, bed-sitting rooms and permanently located manufactured or mobile homes.

Behind the heat-radiating ceramic glass, a four-piece PHAZER log set (back log, front log and two cross-over logs) sits on glowing and charcoal embers and produces Napoleon's YELLOW DANCING FLAMES. The door is chosen separately and is required: metallic black (GS328K-1) or satin chrome (GS328S-1). Add the satin chrome accent bar (AR28SS) or ornamental trivet (GS200-SS) to dress it up, and the standard safety barrier keeps hands away from the hot glass.

On natural gas the Haliburton is rated up to 30,000 BTU/h input and 25,500 BTU/h output; on propane 26,000 BTU/h input and 22,360 BTU/h output (manual p.5). That is a lot of heat for a stove only 22 1/2" wide, enough to zone-heat a large room or open area. The brochure notes built-in blowers to spread the heat; per the manual the blower is thermally activated, starting about 15 to 30 minutes after lighting and running about 30 to 45 minutes after shut-off.

Two ignition choices are offered. The electronic GDS28-1NE uses intermittent pilot ignition (IPI) with a continuous pilot (CPI) mode for cold weather and a seven-day timer, and keeps working in a power failure on its AA battery back-up. The millivolt GDS28-1NSB lights with a push-button igniter and needs no electricity at all for the burner. Both work with an optional wall switch, the F45 on/off remote, the F60 thermostatic remote or the W660-0160 wall control, and the 100% SAFE GUARD gas control system adds peace of mind.

Venting is 4" / 7" direct vent, with runs up to 20 ft horizontally or 40 ft vertically, periscope terminations for below-grade walls, and the option of venting up an existing masonry chimney with a 3" co-linear aluminium liner. Compared with the smaller Bayfield (GDS25), the Haliburton gives more output in a similarly compact footprint, with a choice of millivolt or electronic ignition, and it carries Napoleon's President's Limited Lifetime Warranty.

Key features

  • Up to 30,000 BTU/h: natural gas input, 25,500 BTU/h output; propane 26,000 / 22,360 BTU/h (manual p.5)
  • Compact design for smaller spaces: 22 1/2" W x 26 3/4" H x 18 1/2" D (spec sheet; brochure)
  • Cast-iron stove on a pedestal base: gas line access hole in the pedestal (spec sheet)
  • Heat-radiating ceramic glass: one-piece 15" x 11 3/8" or two-piece 4 3/4" x 11 3/8" glass (spec sheet)
  • YELLOW DANCING FLAMES: brochure
  • PHAZER log set and embers included: back, front and two cross-over logs with glowing and charcoal embers (manual pp.29-30)
  • Door required, two finishes: GS328K-1 metallic black or GS328S-1 satin chrome (2026 price book: mandatory door)
  • Standard safety barrier included: brochure; manual p.27
  • Flame and heat adjustment
  • Built-in blower: thermally activated: on about 15-30 min after lighting, off 30-45 min after shut-down (brochure; manual p.40)
  • Electronic or millivolt ignition: GDS28-1NE IPI with CPI mode and 7-day timer; GDS28-1NSB millivolt with push-button igniter (manual pp.34-35)
  • No electricity required (millivolt model): brochure
  • Battery back-up (electronic model): four AA batteries keep it running in a power failure (manual p.32)
  • Remote and wall-control options: F45 on/off remote, F60 thermostatic remote, W660-0160 wall control, W660-0081 wall thermostat (2026 price book)
  • 100% SAFE GUARD gas control system
  • Direct vent, 4" / 7": up to 20 ft horizontal / 40 ft vertical; existing-chimney option with 3" co-linear liner (manual pp.9-10, 18)
  • Firestop included
  • Approved for bedrooms and mobile homes: manual pp.5, 7
  • Field convertible to propane: W175-0720 kit for the electronic model (2026 price book)
  • President's Limited Lifetime Warranty: manual p.52

Specifications

Models GDS28-1NE (natural gas, electronic IPI); GDS28-1NSB (natural gas, millivolt). Propane versions GDS28-1PE / GDS28-1PSB per manual p.5
Unit dimensions 22 1/2" W x 26 3/4" H x 18 1/2" D; front projection 1 3/4" (spec sheet)
Framing dimensions None required (freestanding stove)
Viewing area Ceramic glass 15" x 11 3/8" one-piece or 4 3/4" x 11 3/8" two-piece (spec sheet)
Clearances to combustibles Flat against a back wall beside a side wall: stove back 2" and vent 4" from the back wall, stove side 7" and vent 14 3/4" from the side wall. In an alcove: 7" from each side wall and 2" from the back wall. Across a corner (set at 45°): the stove's rear corner 1" from the side wall and the vent 9 1/2" from the side wall; at 1" from the wall, access to the blower switch, on/off switch or blower cord may not be practical (manual p.19 figure); at least 20" from the stove top to the ceiling; vent pipe: horizontal runs 2" top and 1" bottom and sides, vertical runs 1" all round; mantels and shelves must keep these clearances; front: keep furniture and other objects at least 48" away (manual p.6); floor: over carpet, vinyl or other combustible flooring (other than wood), a metal or wood panel the full width and depth of the stove (manual pp.6, 19)
Max input NG 30,000 BTU/h; LP 26,000 BTU/h (manual p.5)
Max output NG 25,500 BTU/h; LP 22,360 BTU/h (manual p.5)
Inlet gas pressure NG 4.5" w.c. min / 7" max; LP 11" w.c. min / 13" max (manual p.5)
Manifold pressure NG 3.5" w.c.; LP 10" w.c. (manual p.5)
Gas connection 1/2" supply with flex connector (3/8" without); manual shut-off valve included (manual p.26)
Electrical Electronic model: 6 V battery pack with four AA batteries for back-up; never connect 110 V to the control valve (manual pp.3, 32). Millivolt model: no electricity needed
Venting Direct vent, 4" exhaust / 7" intake (manual p.9)
High altitude Rated 0-4,500 ft; above 4,500 ft reduce input 4% per 1,000 ft (manual p.5)
Certification CSA 2.22 / ANSI Z21.50 (manual cover)

BTU figures are gas input ratings unless stated as output.

Dimensions and clearances

  • Stove: 22 1/2" wide x 26 3/4" high x 18 1/2" deep (spec sheet; dimension figure manual p.8)
  • Clearances to combustibles (manual p.19 figure): against a back wall beside a side wall, stove back 2" and vent 4" from the back wall, stove side 7" and vent 14 3/4" from the side wall; in an alcove, 7" from each side wall and 2" from the back wall; across a corner at 45°, the stove's rear corner 1" and the vent 9 1/2" from the side wall. At the 1" corner minimum, the blower switch, on/off switch and blower cord may be hard to reach.
  • Ceiling: at least 20" from the top of the stove (manual p.19)
  • Vent pipe clearances: horizontal 2" top, 1" bottom and sides; vertical 1" all round (manual p.19)
  • Mantels and shelves must keep the clearances to combustibles (manual)
  • Floor: over carpet, vinyl or other combustible flooring (other than wood) install on a metal or wood panel the full width and depth of the stove (manual pp.6, 19)
  • Keep furniture and other objects at least 48" from the front (manual p.6)

What's included

  • Haliburton cast-iron stove body on pedestal base
  • Heat-radiating ceramic glass
  • PHAZER log set: back, front and two cross-over logs (manual p.29)
  • Glowing embers and charcoal embers (manual p.30)
  • Standard safety barrier (manual p.27)
  • Built-in blower (brochure; manual p.40)
  • Firestop
  • Manual gas shut-off valve (manual p.26)
  • Logo (manual p.30)

Required components

  • Door, choose one (mandatory per the 2026 price book): GS328K-1 metallic black or GS328S-1 satin chrome
  • 4" / 7" direct vent system from one approved manufacturer: Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Metal-Fab; never mix systems (manual p.9)
  • Starter adaptor where the vent brand needs one: GDS924N (DuraVent), 4DSC-N2 (Amerivent), 4DT-AAN (Direct Temp) or 4DNA (Metal-Fab SuperSeal) (manual p.9)
  • A Wolf Steel termination: wall terminal GD175, roof terminal GD-110 (1/12-7/12), GD111 (8/12-12/12) or GD-112 (flat), or periscope GD-180 (manual p.9)
  • Vent supports every 3 ft (W010-0067 support ring or equivalent) (manual p.9)
  • Floor panel where installed over carpet or vinyl (manual p.6)

Optional accessories

  • AR28SS accent bar, satin chrome
  • GS200-SS ornamental trivet, satin chrome
  • F45 remote control, on/off with digital screen
  • F60 thermostatic remote control with digital screen
  • W660-0160 wall mount control
  • W660-0081 wall mount digital thermostat
  • W361-0239-BULK ambient-glow embers
  • W175-0720 natural gas to propane conversion kit (electronic ignition)
  • Millivolt wall switch or thermostat (manual p.26)

Downloads

Installation and safety notes

⚠ Important: Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This appliance must be installed and serviced by a qualified professional following Napoleon's installation manual. The glass gets very hot, so keep children, pets and furniture away and always use the safety barrier.

General information (manual pp.5-8)

  • Install and service by a qualified installer, service agency or gas supplier; for indoor use only (pp.2, 6).
  • Certified to CSA 2.22 / ANSI Z21.50.
  • Approved for bedrooms and bed-sitting rooms; for permanently located manufactured or mobile homes where local codes allow, and the stove must be fastened in place (pp.5, 7).
  • Massachusetts: licensed plumber or gas fitter, T-handle gas shut-off, flex connector no longer than 36" and a CO detector are required (p.6).
  • Rated 0-4,500 ft; above 4,500 ft reduce input 4% per 1,000 ft (p.5).
  • Use only the certified conversion kit to change gases.

Venting (manual pp.9-18)

  • 4" / 7" vent; up to 20 ft horizontal and 40 ft vertical; at most two horizontal or three vertical flex connections (pp.9-10).
  • Minimum vertical rise is critical to burner start-up: 29" to 55 3/4" depending on the configuration (p.10).
  • Support the vent every 3 ft; seal joints with red high-temperature RTV (W573-0002) and the flue collar with black Mill Pac (W573-0007) (pp.9, 19).
  • Terminal clearances include 12" above grade, 9" (US) / 12" (Canada) from opening windows or doors, 7 ft above public walkways, 16" above the roof (p.12).
  • Periscope GD-180: bottom air slot at least 12" above grade, maximum 8 ft of vent on a stove (p.11).
  • Existing masonry chimney: 3" aluminium co-linear flex the full chimney length with a vent adaptor off the appliance (p.18).
  • Never connect to a flue that serves a solid-fuel appliance (p.4).

Installation and clearances (manual pp.19-25)

  • Keep the clearances to combustibles listed in the specifications (for example 7" from a side wall and 2" from the back wall, or 1" at the rear corner in a 45° corner install) and at least 20" to the ceiling (p.19).
  • Over carpet or vinyl, use a full-size metal or wood floor panel (p.19).

Gas and controls (manual p.26)

  • 1/2" supply with flex connector (3/8" without); leak-test all joints.
  • Optional millivolt wall switch or thermostat: maximum lead length 100 ft at 14 AWG, 60 ft at 16 AWG, 40 ft at 18 AWG.

Finishing (manual pp.27-30)

  • Fit the safety screen and the certified door; only doors and fronts certified with this stove may be used (pp.3, 27-28).
  • Place the PHAZER logs and embers exactly as shown; use only certified PHAZER logs and embers (pp.29-30).
  • Never run the stove with the glass removed, cracked or broken (p.4).

Operation (manual pp.31-35)

  • Electronic model: IPI or CPI pilot mode set with the ACS switch or remote, seven-day timer, four AA battery back-up (pp.32-34).
  • Millivolt model: pilot lit with the push-button igniter (p.35).
  • Open or remove the glass door when lighting the pilot for the first time or after the gas has run out (p.3). Do not operate below 32°F (0°C) (p.3).

Maintenance (manual pp.38-40)

  • Have the stove and venting inspected by a qualified service person at least once a year; keep the air intake terminal clear (p.9).
  • Blower service is through the rear panel (p.40).
  • Do not use the stove if any part has been under water (p.4). Keep children and pets away from the hot glass and fit a CO detector nearby.

Building code information

Warranty

  • Napoleon President's Limited Lifetime Warranty (Haliburton installation and operation manual W415-2339 rev. D, pp.52-53).
  • Lifetime, for as long as the original purchaser owns it: combustion chamber, heat exchanger, steel burner, PHAZER logs and embers, rocks, ceramic glass (thermal breakage only), gold-plated parts (tarnish), porcelain enamel components and aluminum extrusion trim.
  • Electrical (110 V and millivolt) components and wear parts (blowers, gas valves, thermal switches, switches, wiring, remote controls, igniters, gaskets, pilot assemblies): replacement parts free in the first year.
  • Labour for warranty repairs: free in the first year, with prior approval through an authorized dealer, at Napoleon's set rate schedule (gas log sets excluded).
  • Years 1 to 10: defective lifetime-covered parts repaired or replaced free at Napoleon's discretion; from 10 years on, replacement parts at 50% of the current retail price.
  • Who is covered: the original purchaser, bought through an authorized Napoleon dealer and installed by a licensed, authorized technician per the instructions and local codes; non-transferable; starts at original installation; proof of purchase with model and serial number needed.
  • Key exclusions: misuse, neglect, lack of maintenance, accidents, alteration, other makers' parts, heat or chemical damage to finishes, chipped porcelain, mechanical breakage of PHAZER logs, overfiring, downdrafts, venting or negative-pressure problems, water, weather or condensation damage; shipping, travel and diagnostic charges.

California Proposition 65

WARNING: This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

Flames and flame colors on the website may appear differently in real life.

Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.

Frequently asked questions — GDS28-1NE

What venting does it use, and how far can it run?

4" exhaust / 7" intake direct vent, up to 20 ft horizontally or 40 ft vertically, with a minimum vertical rise of 29" to 55 3/4" depending on the configuration. It can also vent up an existing masonry chimney with a 3" aluminium co-linear liner the full length of the chimney.

Can it be converted to propane?

Yes. The W175-0720 natural gas to propane conversion kit converts the electronic-ignition model. On propane it is rated 26,000 BTU/h input and 22,360 BTU/h output.

Does it work in a power outage?

Yes. The GDS28-1NE keeps running in a power failure on its battery back-up of four AA batteries (6 V pack).

Is a remote included?

No remote is included. Napoleon offers the F45 on/off remote, the F60 thermostatic remote, the W660-0160 wall control and the W660-0081 wall thermostat as options.

How much heat does it give?

On natural gas it is rated up to 30,000 BTU/h input and 25,500 BTU/h output, and a thermally activated built-in blower spreads the heat.

What's the warranty?

Napoleon's President's Limited Lifetime Warranty: lifetime coverage on the combustion chamber, heat exchanger, burner, PHAZER logs and embers and ceramic glass (thermal breakage), with electrical parts, wear parts and labour covered in the first year.

Loading component details…

Add to cart to see your price.

Call for best price

Similar Products