Napoleon Ascent X 36 Direct Vent Gas Fireplace BX36

SKU / Model: BX36NTRE

Free Fast Shipping
In-stock items are processed in 1–2 business days.

$3,629.00

Black Friday Savings applied in your cart

YOUR SPECIAL OFFER IS AVAILABLE

This product qualifies for an exclusive special offer.

Complete your selections and add this product to your cart to unlock the eligible offer.

Offer eligibility and final promotional pricing are confirmed in the cart. Accessories qualify separately. Offers may change.

Product overview

The Napoleon Ascent X 36 is a traditional built-in direct vent gas fireplace that pairs a classic split oak fire with a premium safety barrier, so you keep the full view of the flames while the family stays safe from the hot glass. It suits living rooms, family rooms, bedrooms and basements, and the manual approves it for bedrooms, bathrooms and mobile homes. Choose BX36NTRE natural gas electronic, BX36NTR natural gas millivolt, or BX36PTRE propane electronic.

Behind 30 11/16" x 23 11/16" of heat-radiating ceramic glass, hand-painted PHAZER split oak logs sit on a glowing ember bed with ember-bed lighting and a NIGHT LIGHT. Make it your own with optional MIRRO-FLAME porcelain or brick panels, Beach Fire, Shore Fire, Woodland or mineral rock media, Heritage or Zen fronts and 3" finishing trims.

The pan-style burner delivers 26,000 BTU/h maximum input (natural gas; propane 25,000 BTU/h, manual p.5) with flame and heat adjustment. The heat-circulating blower (AUB, variable speed with thermostatic control) and the F60 thermostatic remote are both included per the 2026 price book, and optional Universal Heat Management or the LHAD hot air distribution kit can move heat away from the wall above or into another room.

Ignition and controls: Electronic models: pilot on demand (IPI) with continuous pilot (CPI) mode; BX36NTR millivolt model uses a standing pilot with a fast-acting thermocouple (manual pp.50-51, 67). The optional eFIRE Bluetooth controller adds app control, and a USB power bank keeps the fireplace running during a power outage.

The Ascent X 36 uses 4" exhaust / 7" intake direct vent pipe, flex or rigid, up to 20 ft horizontal and 40 ft vertical, and shares its framing with the Ascent and Ascent Linear series for easy changeovers. Compared with the Ascent X 42, the 36 fits a smaller 35 1/2" wide framing, uses 4" / 7" vent and can run up an existing masonry chimney, and it is the one to choose if you want a millivolt version or a wrought-iron surround. It carries Napoleon's President's Limited Lifetime Warranty.

Key features

  • 26,000 BTU/h maximum input: natural gas; propane 25,000 BTU/h, manual p.5
  • Premium safety barrier included: keeps the full flame view (brochure)
  • Heat-radiating ceramic glass: 30 11/16" x 23 11/16"
  • PHAZER split oak logs included: GL-704 split oak log set, 6 logs, with glowing and charcoal embers (manual pp.59-61)
  • Ember-bed lighting and NIGHT LIGHT
  • Pan-style burner
  • Flame and heat adjustment
  • Heat-circulating blower included: AUB variable speed with thermostatic control (2026 price book: included)
  • F60 thermostatic remote included: 2026 price book: included
  • Ignition: Electronic models: pilot on demand (IPI) with continuous pilot (CPI) mode; BX36NTR millivolt model uses a standing pilot with a fast-acting thermocouple (manual pp.50-51, 67)
  • Battery back-up option: USB power bank (not supplied) runs the control board in a power failure (manual p.45)
  • Optional eFIRE app control: EFCN-PF0 (NG) / EFCP-PF0 (LP)
  • Flex or rigid venting: 4" exhaust / 7" intake
  • Optional heat management: UHM / UHMF Universal Heat Management, LHAD hot air distribution, GA-72 hot air exhaust with GD36 sensor
  • Same framing as Ascent and Ascent Linear: brochure
  • Approved for bedrooms, bathrooms and mobile homes: manual p.5
  • President's Limited Lifetime Warranty

Specifications

Models BX36NTRE natural gas electronic, BX36NTR natural gas millivolt, or BX36PTRE propane electronic
Unit dimensions 35" W x 34 5/8" H x 15 3/4" D (brochure; manual dimension figure)
Framing dimensions 35 1/2" W x 35" H x 16" D rough opening; allow for the finished floor and hearth thickness when setting the height (manual pp.29, 53; spec sheet). Corner install: 35 1/8" along each wall from the corner, 49 3/4" across the corner (manual p.29)
Viewing area 30 11/16" x 23 11/16" glass (spec sheet)
Clearances to combustibles Front: keep furniture and other objects at least 48" away; enclosure at least 50 1/2" high for top vent or 44" for rear vent, ceiling at least 54" (manual pp.30-31); vent pipe: 1" sides and bottom and 3" top on horizontal runs, 1" all round on vertical runs; combustible mantel without Universal Heat Management: 2" deep at 5", 4" at 7", 6" at 9", 8" at 11" above the reference line (ref. A 31 5/8"), deeper mantels allowed with UHM (manual section 10.4; spec sheet); non-combustible facing may project up to 4" from the barrier face, each extra 1" adding 2" to the side, top and bottom clearances
Max input 26,000 BTU/h maximum input, natural gas; propane 25,000 BTU/h, manual p.5
Inlet gas pressure NG 4.5" w.c. min, 7" w.c. max; LP 11" w.c. min, 13" w.c. max (manual p.5)
Manifold pressure NG 3.5" w.c.; LP 10" w.c. (manual p.5)
Electrical 115 V, 60 Hz, under 12 A; hardwired (manual)
Venting Direct vent, 4" exhaust / 7" intake, top or rear
High altitude Rated 0-4,500 ft; above 4,500 ft reduce input 4% per 1,000 ft (manual p.5)
Certification CSA 2.22 / ANSI Z21.50 (manual cover)

BTU figures are gas input ratings.

Dimensions and clearances

  • Fireplace: 35" wide x 34 5/8" high x 15 3/4" deep
  • Rough framing: 35 1/2" wide x 35" high x 16" deep; allow for the finished floor and hearth thickness when setting the height (spec sheet; manual pp.29, 34, 53)
  • Enclosure at least 50 1/2" high for top vent or 44" for rear vent; ceiling at least 54" (manual pp.30-31)
  • Vent clearances: horizontal runs 1" sides and bottom, 3" top; vertical runs 1" all round (manual)
  • Combustible mantel: Without UHM: 2" deep at 5", 4" at 7", 6" at 9", 8" at 11" above the reference line (ref. A 31 5/8"); with UHM much deeper mantels are allowed (manual section 10.4; spec sheet)
  • TV above: only with the Universal Heat Management kit in certain recessed layouts
  • Non-combustible facing may project up to 4" from the barrier face; each extra 1" adds 2" to the side, top and bottom clearances
  • Keep furniture and other objects at least 48" from the front

What's included

  • Ascent X 36 fireplace with ceramic glass door and premium safety barrier
  • GL-704 split oak log set, 6 logs, with glowing and charcoal embers (manual pp.59-61)
  • AUB heat-circulating blower (2026 price book: included)
  • F60 thermostatic remote with receiver (2026 price book: included)
  • Firestop spacers and insulated sleeve (spec sheet)
  • Nailing tabs and hood

Required components

  • 4" exhaust / 7" intake direct vent system from one approved manufacturer: Wolf Steel, Metal-Fab, BDM, Simpson DuraVent or Selkirk Direct Temp; never mix brands
  • A Wolf Steel termination: wall GD-222 / GD-222R / ST47U, roof GD-110 / GD-111 / GD-112, periscope GD-201, flex kits GD-220 / GD-330 (manual p.13)
  • Vent supports every 3 ft and firestops where the vent passes through walls, floors or ceilings
  • Dedicated 115 V supply, hardwired, and a gas line with shut-off valve

Optional accessories

  • Decorative panels: PRPB36 MIRRO-FLAME black porcelain, GD863KT Newport, DBPX36WS Westminster standard or DBPX36WH Westminster herringbone brick
  • Decorative fronts and surrounds: H35F Heritage, Z35F Zen, CFF 3" black surround barrier, GX427K black surround or GX725WI scalloped wrought iron surround with premium screen
  • Finishing trims: TK35 3" black 3- or 4-sided, BT36K 3" black 4-sided bevelled
  • Media kits: BFKXS Beach Fire logs, SFKS Shore Fire, WLKS Woodland, MRKS mineral rocks; W361-0239-BULK ambient-glow embers
  • Heat management: UHM / UHMF, LHAD, GA-72 with GD36 sensor
  • EFCN-PF0 / EFCP-PF0 eFIRE controller; W660-0081 wall thermostat
  • W175-0401 natural gas to propane conversion kit (electronic models)

Downloads

Product video

Installation and safety notes

⚠ Important: Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This appliance must be installed and serviced by a qualified professional following Napoleon's installation manual. The glass gets very hot, so keep children, pets and furniture away and always use the safety barrier.

General information (manual pp.5-12)

  • Install and service by a qualified installer, service agency or gas supplier; in Massachusetts a licensed plumber or gas fitter, a T-handle shut-off, a flex connector no longer than 36" and CO detectors are required.
  • Certified to CSA 2.22 / ANSI Z21.50; approved for bathrooms, bedrooms, bed-sitting rooms and mobile homes; indoor use only.
  • Above 4,500 ft reduce input 4% per 1,000 ft unless the local authority says otherwise.

Rough framing (manual pp.28-34)

  • Frame to 35 1/2" wide x 35" high x 16" deep rough framing (spec sheet; manual p.34).
  • Enclosure at least 50 1/2" high for top vent or 44" for rear vent; ceiling at least 54" (manual pp.30-31).
  • Non-combustible board is required where the manual specifies it; wood and drywall are not allowed there.

Venting (manual pp.13-27, 35-43)

  • 4" exhaust / 7" intake vent, up to 20 ft horizontal and 40 ft vertical; at most two horizontal or three vertical flex connections; support every 3 ft.
  • Terminations: wall GD-222 / GD-222R / ST47U, roof GD-110 / GD-111 / GD-112, periscope GD-201, flex kits GD-220 / GD-330 (manual p.13).
  • Can vent up an existing masonry chimney with a 3" co-linear liner, 10 to 40 ft (manual p.42); optional PVA-ASCENT power vent adaptor (2026 price book).
  • Inside corner terminals: 0" to a non-combustible corner, 2" to a combustible corner.

Electrical and gas (manual pp.44-49)

  • Hardwire to 115 V; never connect 110 V to the valve or wall switch.
  • USB power bank (not supplied) runs the control board in a power failure (manual p.45).
  • Leak-test all gas connections; disconnect before testing above 1/2 psig.

Finishing (manual pp.52-61)

  • Fit the hood, safety barrier and glass door; never run the fireplace with the glass removed, cracked or broken.
  • Combustible mantel: Without UHM: 2" deep at 5", 4" at 7", 6" at 9", 8" at 11" above the reference line (ref. A 31 5/8"); with UHM much deeper mantels are allowed (manual section 10.4; spec sheet).
  • Place the logs, embers and glass media exactly as shown; keep embers off the burner ports.

Maintenance (manual pp.64-66)

  • Have a qualified technician inspect the fireplace before first use and at least once a year: clean the burner and pilot, check the relief door gasket and gas connections.
  • Keep drywall dust out of the blower; clean the glass only when cool with an ammonia-free cleaner.
  • Keep children and pets away from the hot glass; fit a CO detector nearby.

Building code information

Warranty

  • Napoleon President's Limited Lifetime Warranty (Ascent BX36 installation manual W415-2944 rev. B, section 15.0, p.73).
  • Lifetime, for as long as the original purchaser owns it: combustion chamber, heat exchanger, steel burner, PHAZER logs and embers, rocks, ceramic glass (thermal breakage only), gold-plated parts (tarnish), porcelain enamel components and aluminum extrusion trim.
  • Electrical (110 V and millivolt) components and wear parts (blowers, gas valves, thermal switches, switches, wiring, remote controls, igniters, gaskets, pilot assemblies): replacement parts free in the first year.
  • Labour for warranty repairs: free in the first year, with prior approval through an authorized dealer, at Napoleon's set rate schedule (gas log sets excluded).
  • Years 1 to 10: defective lifetime-covered parts repaired or replaced free at Napoleon's discretion; from 10 years on, replacement parts at 50% of the current retail price.
  • Who is covered: the original purchaser, bought through an authorized Napoleon dealer and installed by a licensed, authorized technician per the instructions and local codes; non-transferable; starts at original installation; proof of purchase with model and serial number needed.
  • Key exclusions: misuse, neglect, lack of maintenance, accidents, alteration, other makers' parts, heat or chemical damage to finishes, chipped porcelain, mechanical breakage of PHAZER logs, overfiring, downdrafts, venting or negative-pressure problems, water, weather or condensation damage; shipping, travel and diagnostic charges.

California Proposition 65

WARNING: This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

Flames and flame colors on the website may appear differently in real life.

Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.

Frequently asked questions — BX36NTRE

What size framing does it need?

A rough opening of 35 1/2" wide x 35" high x 16" deep, with the height set to allow for the finished floor and hearth. The enclosure must be at least 50 1/2" high for top venting or 44" for rear venting, and the ceiling at least 54".

What venting does it use, and how far can it run?

Direct vent with 4" exhaust / 7" intake pipe, top or rear, up to 20 ft horizontally and 40 ft vertically. It can also vent up an existing masonry chimney with a 3" co-linear liner from 10 to 40 ft.

Can it be converted to propane?

Yes. The W175-0401 natural gas to propane conversion kit fits the electronic models. On propane it is rated 25,000 BTU/h input, against 26,000 BTU/h on natural gas.

Does it work in a power outage?

Yes. A USB power bank (not supplied) runs the control board during a power failure.

Are a remote and blower included?

Yes. The F60 thermostatic remote with receiver and the AUB variable-speed heat-circulating blower are both included.

How high must a mantel be, and can a TV go above it?

Without Universal Heat Management, a combustible mantel can be 2" deep at 5", 4" at 7", 6" at 9" or 8" at 11" above the reference line; deeper mantels are allowed with UHM. A TV above is allowed only with the Universal Heat Management kit in certain recessed layouts.

Loading component details…

Add to cart to see your price.

Call for best price

Similar Products