The Napoleon Ascent Linear 56 (BL56NTE) is a 56" wide built-in direct vent natural gas linear fireplace that brings a clean, contemporary ribbon of flame to living rooms, bedrooms, basements and media walls at an approachable price. It is the essential model of Napoleon's Ascent Linear family: a crisp, frameless look with a sparkling Topaz CRYSTALINE glass ember bed included in the box, and plenty of room to personalise.
Keep the modern glass bed as it comes, or change the look with glass embers or beads in six colours, mineral rocks, the Shore Fire or Woodland kits, the Beach Fire log set, or Birch, Split Oak and Driftwood log kits. MIRRO-FLAME reflective black porcelain panels or Ledgestone panels dress the firebox, and finishing trims frame the opening.
Gas input is up to 28,000 BTU/h with turn-down to 18,500 BTU/h on natural gas (manual p.5), a good match for zone heating a room without overheating it. An optional variable-speed blower kit moves warm air into the room, and optional heat management (Universal Heat Management (UHM), or the LHAD hot air distribution kit) redirects heat to reduce mantel clearances and make a TV above more practical.
The fireplace uses an intermittent pilot ignition with a seven-day continuous pilot option, run from a wall switch (required) or an optional remote: on/off F45, thermostatic F60, or the eFIRE Bluetooth controller for app control. A battery back-up arrangement keeps it running during a power outage (4 AA battery housing connected by USB-C (manual p.39)). Non-combustible cement board, an easy-access air control and a stainless steel flex connector simplify installation.
The BL56NTE vents through 5" exhaust / 8" intake direct vent pipe from Wolf Steel, Metal-Fab, BDM, Simpson DuraVent, Selkirk, Olympia or ICC, with horizontal runs up to 20 ft and vertical runs up to 40 ft (it can also be reduced to 4/7 venting with kit A4758AK). Compared with the Ascent Linear Premium, which adds a blower, top lights and an eFIRE remote as standard, this model lets you add only the options you want. It is approved for bedrooms, bathrooms and mobile homes and is covered by Napoleon's President's Limited Lifetime Warranty.
Key features
- Up to 28,000 BTU/h: natural gas input; turn-down to 18,500 BTU/h (manual p.5)
- Topaz CRYSTALINE ember bed included: use only Topaz glass media in a single layer over the burner (manual p.54)
- Optional media: glass embers and beads, mineral rocks, Shore Fire, Woodland and Beach Fire kits, Birch, Split Oak or Driftwood logs
- Non-combustible cement board included
- Easy-access air control
- Stainless steel flex connector
- Battery back-up control: 4 AA battery housing connected by USB-C (manual p.39)
- Intermittent pilot ignition: seven-day continuous pilot option; wall switch or optional remote (manual pp.42-43)
- Optional remotes and app control: F45 on/off, F60 thermostatic, eFIRE Bluetooth controller
- Optional blower kit: variable speed, thermostatic; starts about 15 minutes after lighting (manual p.55)
- Optional heat management: LHAD hot air distribution, hot air exhaust kit and Universal Heat Management (UHM) to reduce clearances
- Safety barrier included
- Flexible or rigid venting: 5" exhaust / 8" intake top vent
- Approved for bedrooms, bathrooms and mobile homes
- Certified to CSA 2.22 / ANSI Z21.50
- President's Limited Lifetime Warranty
Specifications
| Model | BL56NTE (natural gas, electronic ignition) |
|---|---|
| Unit dimensions | 56" W x 38 13/16" H including top stand-offs (cabinet 33 1/16") x 18 5/16" D (manual p.11) |
| Framing dimensions | 56 1/2" (1435 mm) W x 39 3/8" (1000 mm) H x 18 9/16" (471 mm) D, flush; recessed installs need an 84" (2130 mm) minimum enclosure height with a 3 1/2" (89 mm) recess, and a 2x4 frame backed with 3/4" plywood can carry TV hardware (manual pp.27, 45-46) |
| Viewing area | 52 1/2" viewing width (manual p.11); viewing height not published by the manufacturer |
| Clearances to combustibles | 0" to the back and side stand-offs; vent 1" at the sides and 3" at the top (1" with a 38" vertical rise straight off the collar), vertical vent 3" all round; 0" where non-combustible finishing is used; non-combustible facing may project up to 4" from the door face, and beyond that needs 2" more side and top clearance for every extra 1"; combustible mantel 12" above the opening for a 2" deep mantel, 14" for 4", 16" for 6" and 18" for 8" (lower only with the UHM / DHM system installed); keep objects 4 ft (1.22 m) in front; no hearth extension required (manual pp.13, 26-27, 47, 50-51) |
| Fuel | Natural gas; propane conversion kits: NG to LP W175-0738 / LP to NG W175-0739 |
| Gas input, natural gas | 28,000 BTU/h max / 18,500 BTU/h min (manual p.5) |
| Inlet gas pressure | NG 4.5" w.c. min, 7" w.c. max (never above 13" w.c.); LP 11" min, 13" max (manual p.5) |
| Manifold pressure | NG 3.5" w.c.; LP 10" w.c. (manual p.5) |
| Venting | Direct vent, 5" exhaust / 8" intake, top (manual pp.13-15) |
| Blower | Optional (AUB or GZ600KT) |
| Ignition | Intermittent pilot (IPI) with CPI option, wall switch or remote |
| High altitude | Above 4,500 ft reduce input 4% per 1,000 ft (manual p.5) |
BTU figures are gas input ratings, not delivered heat output.
Dimensions and clearances
- Combustible mantels: 12" above the opening for a 2" deep mantel, 14" for 4", 16" for 6" and 18" for 8" (manual p.51); clearances can be reduced only with the UHM / DHM system installed.
- TV above: typical minimums 6" above and 2.5" to the side, 2" to 3" behind; a heat management kit is recommended (manual p.52)
- Keep objects at least 4 ft (1.22 m) in front of the fireplace; no hearth extension required (manual pp.26-27)
What's included
- Glass door and safety barrier (manual p.5)
- Topaz CRYSTALINE glass ember bed
- Non-combustible cement board
- Stainless steel flex connector
- Battery back-up control (not listed as included in the 2026 price book; 4 AA battery housing connected by USB-C (manual p.39))
- Hardware kit and vent shield (manual pp.10, 25)
Required components
- Wall switch or thermostat, or an optional remote: the switch connection is mandatory (manual p.38); options F45, F60, wall thermostat W660-0081
- 5" exhaust / 8" intake direct vent system from one approved manufacturer: wall terminal GD422-1 / GD422R-2 / ST58U-1, roof terminal GD410 / GD411 / GD412, periscope GD401, flex kits GD420 (5 ft) / GD430 (10 ft) (manual pp.13-25) (2026 book: propane models need rigid vent or a power vent)
- Matching starter adapter for third-party vent: Metal-Fab 5DNA, DuraVent W175-0170, Selkirk 5DT-AAN or Olympia VDV-NA05-58F (manual p.14)
- Firestops and vent shield as required for the vent run (manual pp.25, 31)
- 120 V supply, hard-wired or receptacle (manual p.38)
Optional accessories
- Blower kit, variable speed and thermostatic: AUB or GZ600KT
- Standard log kits: Birch BLKBLP56, Split Oak OLKBLP56 or Driftwood DLKBLP56; Beach Fire log set BFKL
- Media: Topaz and coloured glass embers MKGA / MKGK / MKGB / MKGC / MKGR / MKGT, glass beads MKBA / MKBK / MKBB / MKBC / MKBT, mineral rocks MRKL, Shore Fire kit SFKL, Woodland kit WLKL, ambient-glow embers W361-0239-BULK
- MIRRO-FLAME reflective black porcelain panels PRPL56; Ledgestone panels DBPBL56LS
- 5/8" black 4-sided finishing trim FTBL56BK; 2.5" black Classic surround CSL36K
- Hot air distribution kit LHAD; hot air exhaust kit GA-72 with thermostatic sensor GD36
- Universal Heat Management kit: side grill UHM or front grill UHMF
- Remotes: F45 on/off, F60 thermostatic; eFIRE controller EFCN-PF0 / EFCP-PF0; wall thermostat W660-0081
- 5 ft flex vent extension GA-70; 4/7 reducer kit A4758AK
- Propane conversion: NG to LP W175-0738 / LP to NG W175-0739
Downloads
Product video
Installation and safety notes
⚠ Important: Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This appliance must be installed and serviced by a qualified professional following Napoleon's installation manual. The glass gets very hot, so keep children, pets and furniture away and always use the safety barrier.
General information (pp.5-10)
- Install and service by a qualified installer, service agency or gas supplier; indoor use only.
- Certified to CSA 2.22 / ANSI Z21.50; approved for bedrooms, bathrooms and bed-sitting rooms, and for mobile homes when secured through the base holes (pp.5, 9).
- Rating: 28,000 / 18,500 BTU/h on natural gas (p.5).
- Above 4,500 ft, reduce input 4% for every 1,000 ft unless the local authority says otherwise (p.5).
- Massachusetts: bedroom and bathroom installs must be direct vent sealed combustion; licensed installer, T-handle valve and CO detectors required (p.8).
Dimensions and heat management (pp.11-12)
- Width 56", viewing width 52 1/2"; optional Universal Heat Management (UHM) lowers mantel clearances.
Venting requirements (pp.13-25)
- 5" exhaust / 8" intake venting from Wolf Steel, Metal-Fab, BDM, Simpson DuraVent, Selkirk Direct Temp, Olympia or ICC; third-party systems need their starter adapter; never mix brands or rigid with flex.
- Up to 20 ft horizontal or 40 ft vertical, maximum two horizontal or three vertical flex connections; about 1/4" rise per foot on horizontal runs; support every 3 ft.
- Periscope terminations: maximum 10 ft vent length, bottom air slot at least 12" above grade (p.17).
- Terminal clearances include 12" above grade, 9" (US) from opening windows or doors, 3 ft (US) from a mechanical air inlet, 16" above the roof, 7 ft above a public sidewalk and 2 ft from an adjacent wall (p.19).
- Certified for a power vent kit (p.14).
Rough framing (pp.26-28)
- Framing width 56 1/2" (1435 mm), depth 18 9/16" (471 mm); do not notch framing around the stand-offs; keep 4 ft clear in front; no hearth extension needed.
- Where non-combustible finishing is specified use cement board, tile or marble; never wood or drywall (fire-rated drywall is not acceptable).
Venting installation (pp.29-37)
- Seal the exhaust collar with Mill Pac and use the correct firestops.
- Existing masonry chimney: 3" co-linear aluminium liner with approved co-linear to co-axial adaptors, only in a non-combustible chimney (p.37).
Electrical (pp.38-40)
- Hard-wire or use a receptacle as shown; do not cut or remove the grounding prong; never wire 110 V to the valve or wall switch.
- Battery back-up: 4 AA battery housing connected by USB-C (manual p.39).
Gas and operation (pp.41-43)
- Use the gas type on the rating plate; convert only with the correct Napoleon kit; leak-test with soap solution, never a flame.
- Intermittent pilot with a seven-day continuous pilot mode selected by the ACS switch (p.43).
Finish framing and finishing (pp.44-57)
- Flush framing, or recessed framing with an 84" minimum enclosure height and a 3 1/2" recess; alcoves need extra enclosure volume and a non-combustible recess (pp.45-48).
- Facing must not overhang the opening or block the door's pressure-relief movement; combustible mantels need 12" above the opening for a 2" deep mantel up to 18" for 8" (p.51), and a heat management kit is recommended for a TV above (p.52).
- Spread the Topaz glass in a single layer and keep it off the pilot and rear slots; place any logs exactly as shown (pp.49, 54).
Maintenance (pp.58-59)
- Clean the glass after the first 4 hours with an ammonia-free cleaner; replace only with approved 4 mm tempered glass.
- Have the appliance and venting inspected at least once a year by a qualified technician.
Building code information
- US: local codes, or where none apply the latest National Fuel Gas Code, ANSI Z223.1/NFPA 54.
- Canada: CSA B149.1 Natural Gas and Propane Installation Code and CSA C22.1 Canadian Electrical Code (CSA Group).
- Electrical (US): National Electrical Code, ANSI/NFPA 70.
- Manufactured / mobile homes: HUD 24 CFR Part 3280 (or ANSI/NFPA 501A where 3280 does not apply); Canada CAN/CSA Z240 MH.
Warranty
- Napoleon President's Limited Lifetime Warranty (Ascent Linear installation manual W415-10009842, section 14.0, p.67).
- Lifetime, for as long as the original purchaser owns it: combustion chamber, heat exchanger, steel burner, PHAZER logs and embers, rocks, ceramic glass (thermal breakage only), gold-plated parts (tarnish), porcelain enamel components and aluminum extrusion trim.
- Electrical (110 V and millivolt) components and wear parts (blowers, gas valves, thermal switches, switches, wiring, remote controls, igniters, gaskets, pilot assemblies): replacement parts free in the first year.
- Labour for warranty repairs: free in the first year, with prior approval through an authorized dealer, at Napoleon's set rate schedule (gas log sets excluded).
- Years 1 to 10: defective lifetime-covered parts repaired or replaced free at Napoleon's discretion; from 10 years on, replacement parts at 50% of the current retail price.
- Who is covered: the original purchaser, bought through an authorized Napoleon dealer and installed by a licensed, authorized technician per the instructions and local codes; non-transferable; starts at original installation; proof of purchase with model and serial number needed.
- Key exclusions: misuse, neglect, lack of maintenance, accidents, alteration, other makers' parts, heat or chemical damage to finishes, chipped porcelain, mechanical breakage of PHAZER logs, overfiring, downdrafts, venting or negative-pressure problems, water, weather or condensation damage; shipping, travel and diagnostic charges.
California Proposition 65
WARNING: This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Frequently asked questions — BL56NTE
What size framing does the BL56NTE need?
Flush framing is 56 1/2" (1435 mm) wide, 39 3/8" (1000 mm) high and 18 9/16" (471 mm) deep. Recessed installs need an 84" (2130 mm) minimum enclosure height with a 3 1/2" (89 mm) recess. No hearth extension is required; keep objects 4 ft in front.
What venting does it use, and how far can it run?
5" exhaust / 8" intake direct vent off the top, up to 20 ft horizontal or 40 ft vertical, with a maximum of two horizontal or three vertical flex connections.
Does it work in a power outage?
Yes. The battery back-up arrangement (a USB power bank in place of the control board power supply) keeps it running during a power outage.
Is a remote included?
No. A wall switch or thermostat connection is required. Optional remotes are the F45 on/off, the F60 thermostatic and the eFIRE Bluetooth controller for app control.
Can a TV go above it, and how high must the mantel be?
A combustible mantel must be 12" above the opening for a 2" deep mantel, 14" for 4", 16" for 6" and 18" for 8"; lower clearances are allowed only with the UHM / DHM system. For a TV, Napoleon recommends its optional heat management kit.
What is the warranty?
Napoleon's President's Limited Lifetime Warranty for the original purchaser: lifetime cover on the combustion chamber, heat exchanger, burner and glass (thermal breakage), free in years 1 to 10 and at 50% of retail after that; electrical components, wear parts and labour in the first year.