Napoleon Ascent Multi-View See-Through Gas Fireplace BHD4STN
SKU / Model: BHD4STN
Fireplace only$6,199.00
Black Friday Savings applied in your cart
Unlock an exclusive offer on this product.
Product overview
The Napoleon Ascent Multi-View See-Through (BHD4STN) is a built-in direct vent natural gas fireplace with tempered glass on the front and back, so one fire can be enjoyed from two rooms, as a room divider or between living and dining spaces. It is 45" wide, 38 1/4" high and 25 1/8" deep.
This is the log version of the Multi-View: a PHAZER log set with a charcoal chunk on the log burner gives a full, traditional flame, with optional glowing embers, charcoal, mineral rocks and designer fire art. MIRRO-FLAME porcelain or Newport brick end panels can finish the firebox; a see-through unit takes two kits. Input is up to 30,000 BTU/h, and a safety screen is included.
It runs from an on/off switch with a 6 V battery back-up pack (4 AA), so it works in a power outage; on/off or thermostatic remotes and a modulating valve regulator are optional. Venting is 5" exhaust / 8" intake from a 45-degree top-and-rear collar, up to 20 ft horizontal or 40 ft vertical, reducible to 4"/7" with kit A4758AK. It is approved for bedrooms, bathrooms and mobile homes.
Key features
- Up to 30,000 BTU/h: natural gas input (manual rating)
- See-through viewing: glass front and back
- PHAZER log set burner: one of two burner options in the series
- Tempered heat-resistant glass
- Safety screen included: main barrier
- Firestop included
- Battery back-up control system: 6 V pack with 4 AA batteries
- Optional remote controls: on/off or thermostatic with digital screen
- Optional modulating valve regulator with remote
- Optional decorative end panels: MIRRO-FLAME porcelain PRPHD4 or Newport brick GD851KT
- Optional media: glass beads and embers, mineral rocks, glowing embers, designer fire art
- 45-degree top and rear vent: 5" / 8", reducible to 4" / 7"
- Log set included: PHAZER logs and charcoal chunk
- Approved for bedrooms, bathrooms and mobile homes
- Certified to CSA 2.22 / ANSI Z21.50
- President's Limited Lifetime Warranty
Specifications
| Model | BHD4STN (natural gas, log set, see-through) |
|---|---|
| Unit dimensions | 45" W x 38 1/4" H x 25 1/8" D; gas and electrical inlets 7 9/16" from the base (manual p.9; Napoleon tech spec) |
| Framing dimensions | 46 1/2" (118 cm) framing height; framing width 45 1/2" (115.6 cm) and framing depth A (front to back) 22 1/8" to 24 1/8" (56.2 to 61.3 cm), set by the finishing-support position; enclosure at least 50" (127 cm) high from the appliance bottom and 62 1/4" (158 cm) from the appliance bottom to the ceiling (manual pp.21-23; Napoleon tech spec) |
| Viewing area | See-through (front and back); main glass 28 1/2" x 35 1/2" (Napoleon tech spec, size as listed) |
| Clearances to combustibles | Combustible framing 1/4" to the sides and 8 1/4" to the top; combustible finishing 0" to the sides and top of the appliance; vent 3" to the top and 2" to the sides and bottom of horizontal vent, 1" all round vertical vent; non-combustible facing may project up to 4" from the door face, with 2" more clearance for every extra 1"; mantel: a 2" deep combustible mantel needs 4" of clearance, 4" deep needs 6", 6" deep needs 8" and 8" deep needs 10" (manual p.45 chart); keep furniture and objects 48" (121.9 cm) from the glass (manual pp.21, 23, 44-45) |
| Fuel | Natural gas; field convertible to propane with Napoleon kit |
| Gas input | 30,000 BTU/h max (manual) |
| Inlet gas pressure | NG 4.5" w.c. min, 7" w.c. normal, 13" w.c. max; LP 11" min, 13" max |
| Manifold pressure | NG 3.5" w.c.; LP 10" w.c. |
| Electrical | 115 V, 60 Hz, hard-wired; battery back-up 4 AA |
| Venting | Direct vent, 5" exhaust / 8" intake, 45-degree top and rear (manual p.10) |
| High altitude | Above 4,500 ft reduce input 4% per 1,000 ft |
BTU figures are gas input ratings, not delivered heat output.
Dimensions and clearances
- Combustible mantels: a 2" deep combustible mantel needs 4" of clearance, 4" deep needs 6", 6" deep needs 8" and 8" deep needs 10" (manual p.45 chart); mantel paint must be heat resistant
- On carpet, vinyl or other combustible flooring the appliance must sit on a metal or wood panel covering its full width and depth (manual p.21)
- Keep furniture and objects at least 48" (121.9 cm) away from the glass
What's included
- Glass doors with latch tool
- Safety screen (main barrier)
- Firestop spacer assembly and vent shields
- 6 V battery back-up pack
- PHAZER log set (logs #1-#11) and charcoal chunk on the log burner
Required components
- 5" exhaust / 8" intake direct vent system from one approved manufacturer: wall terminal GD422-1 / GD422R-2 / ST58U-1, roof terminal GD410 / GD411 / GD412, periscope GD401, flex kit GD420 (5 ft) / GD430 (10 ft) (manual pp.10-20)
- Starter adapter for third-party vent: Metal-Fab 5DNA, DuraVent W175-0170, Selkirk 5DT-AAN or Olympia VDV-NA05-58F (manual p.10)
- No extra media required: the log set is included
- Non-combustible facing where required (manual p.44)
Optional accessories
- Decorative end panels: MIRRO-FLAME porcelain PRPHD4 (2 for see-through)
- Newport brick end panels GD851KT (2 for see-through)
- Remote control, on/off with digital screen
- Thermostatic remote control with digital screen
- Modulating valve regulator with remote control
- Mineral rock kit MRKM
- Ambient-glow embers
- Designer fire art LDAC coil / LDNS nickel stix
- 5/8 to 4/7 adaptor kit A4758AK
- Natural gas to propane conversion kit
- Glowing embers W361-0016, charcoal embers W550-0001, charcoal lumps W550-0002
Downloads
Product video
Installation and safety notes
⚠ Important: Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This appliance must be installed and serviced by a qualified professional following Napoleon's installation manual. The glass gets very hot, so keep children, pets and furniture away and always use the safety barrier.
General information (pp.6-8)
- Install and service by a qualified installer, service agency or gas supplier.
- Certified to CSA 2.22 / ANSI Z21.50; approved for bedrooms, bathrooms and bed-sitting rooms, and for mobile homes (pp.6, 8).
- Above 4,500 ft, reduce input 4% for every 1,000 ft unless the local authority says otherwise.
- Massachusetts: T-handle shut-off valve, flex connector no longer than 36" and a CO detector are required.
Dimensions (p.9)
- 45" wide x 38 1/4" high x 25 1/8" deep.
Venting requirements (pp.10-20)
- 5" / 8" venting from Wolf Steel, Metal-Fab, BDM, Simpson DuraVent, Selkirk Direct Temp or Olympia; reduce to 4/7 only with kit A4758AK and a new firestop spacer.
- Up to 20 ft horizontal and 40 ft vertical; flexible vent allows two horizontal or three vertical connections; support every 3 ft; about 1/4" rise per foot recommended.
- Vertical terminations need at least 36" of rise and must end 16" above the highest roof penetration.
- Keep the air terminal unobstructed and inspect it at least once a year.
Framing and enclosure (pp.21-23)
- Minimum enclosure height 50"; 62 1/4" to the ceiling; 1/4" side and 8 1/4" top clearance to combustible framing.
- Protect combustible flooring with a full-size metal or wood panel.
Venting installation (pp.24-30)
- Install firestops and vent shields as shown; use high-temperature sealants W573-0002 / W573-0007.
Electrical (pp.31-33)
- Hard-wire the appliance; install the 6 V battery pack (4 AA) for power-outage operation (p.32).
Gas and operation (pp.34-38)
- Use the gas type on the rating plate; convert only with the correct Napoleon kit; leak-test with soap solution, never a flame.
Finishing (pp.39-51)
- Non-combustible facing may project up to 4" from the door face (p.44); a 2" deep combustible mantel needs 4" of clearance, 4" deep needs 6", 6" deep needs 8" and 8" deep needs 10" (p.45).
- Place the logs exactly as shown on pp.47-51.
Adjustments and maintenance (pp.52-58)
- Inspect the unit and venting before first use and at least once a year by a qualified technician; never run with cracked glass or without the safety screen.
Building code information
- US: local codes, or where none apply the latest National Fuel Gas Code, ANSI Z223.1/NFPA 54.
- Canada: CSA B149.1 Natural Gas and Propane Installation Code and CSA C22.1 Canadian Electrical Code (CSA Group).
- Electrical (US): National Electrical Code, ANSI/NFPA 70.
- Manufactured / mobile homes: HUD 24 CFR Part 3280 (or ANSI/NFPA 501A where 3280 does not apply); Canada CAN/CSA Z240 MH.
Warranty
- Napoleon President's Limited Lifetime Warranty (Ascent Multi-View manual W415-1285, section 17.0, p.70).
- Lifetime, for as long as the original purchaser owns it: combustion chamber, heat exchanger, steel burner, PHAZER logs and embers, rocks, ceramic glass (thermal breakage only), gold-plated parts (tarnish), porcelain enamel components and aluminum extrusion trim.
- Electrical (110 V and millivolt) components and wear parts (blowers, gas valves, thermal switches, switches, wiring, remote controls, igniters, gaskets, pilot assemblies): replacement parts free in the first year.
- Labour for warranty repairs: free in the first year, with prior approval through an authorized dealer, at Napoleon's set rate schedule (gas log sets excluded).
- Years 1 to 10: defective lifetime-covered parts repaired or replaced free at Napoleon's discretion; from 10 years on, replacement parts at 50% of the current retail price.
- Who is covered: the original purchaser, bought through an authorized Napoleon dealer and installed by a licensed, authorized technician per the instructions and local codes; non-transferable; starts at original installation; proof of purchase with model and serial number needed.
- Key exclusions: misuse, neglect, lack of maintenance, accidents, alteration, other makers' parts, heat or chemical damage to finishes, chipped porcelain, mechanical breakage of PHAZER logs, overfiring, downdrafts, venting or negative-pressure problems, water, weather or condensation damage; shipping, travel and diagnostic charges.
California Proposition 65
WARNING: This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Frequently asked questions — BHD4STN
What size framing does the BHD4STN need?
The framing is 46 1/2" (118 cm) high and 45 1/2" (115.6 cm) wide, with a framing depth (A, front to back) of 22 1/8" to 24 1/8", depending on where the finishing supports are set. The enclosure must be at least 50" high from the appliance bottom, with 62 1/4" from the appliance bottom to the ceiling. Combustible framing needs 1/4" at the sides and 8 1/4" at the top.
What venting does it use, and how far can it run?
5" exhaust / 8" intake direct vent from a 45-degree top-and-rear collar, up to 20 ft horizontal or 40 ft vertical, from Wolf Steel, Metal-Fab, BDM, Simpson DuraVent, Selkirk Direct Temp or Olympia. It can be reduced to 4"/7" with kit A4758AK and a new firestop spacer.
Does it work in a power outage?
Yes. The included 6 V battery back-up pack (4 AA batteries) keeps it working during a power outage.
Is a remote included?
No. It runs from an on/off switch. An on/off remote or a thermostatic remote, both with a digital screen, and a modulating valve regulator with remote are optional.
How high must a mantel be?
A 2" deep combustible mantel needs 4" of clearance, a 4" deep mantel 6", a 6" deep mantel 8" and an 8" deep mantel 10", and mantel paint must be heat resistant.
What is the warranty?
Napoleon's President's Limited Lifetime Warranty for the original purchaser: lifetime cover on the combustion chamber, heat exchanger, burner, PHAZER logs and glass (thermal breakage), free in years 1 to 10 and at 50% of retail after that; electrical components, wear parts and labour in the first year.