Monessen Natural Blaze NG Burner NB24NIF-B
SKU / Model: NB24NIF-B
Base price$1,379.00
Unlock an exclusive offer on this product.
Ignition & Controls
Intermittent Pilot (IPI) — included. Intermittent pilot ignition (IPI) uses electronic controls to light the pilot when the fireplace calls for heat. Controls and power requirements depend on the selected model; follow its owner manual.
Product overview
The Monessen Natural Blaze 24 (NB24NIF-B) is the natural gas burner behind Monessen's Deluxe Series vent-free log sets. It is built for homeowners who want to turn an existing wood-burning fireplace, or a listed vent-free firebox, into an efficient gas fire without adding a chimney liner or vent.
Monessen's exclusive Natural Blaze technology lights with tall, lively flames that turn yellow almost immediately, over an active ember bed of volcanic rock and glowing rock wool. Pair it with any of the approved Berkley Oak, Highland Oak, Stony Creek or Beachcomber log sets (sold separately) to choose the look, from a low glowing stack to a tall 11-piece pile.
Input runs from 26,000 to 37,000 BTU/h, and Monessen rates the matching log sets for spaces up to about 1,850 sq ft. Because it is vent-free, practically all of that heat stays in the room, which makes it a strong zone heater for the room you actually use.
This model uses IntelliFire Plus intermittent pilot ignition (IPI) with ODS and the RC300 remote included. It is also dual rated, so it can run vent-free for heat or as a vented decorative log set with the damper fixed open.
Compared with the Glow Getter burners (Charisma, Dynamo, Moxie logs) and the contemporary Lyric glass burner, Natural Blaze is the choice for classic oak, driftwood and stacked-log looks. The NB18 (18 in. log sets) covers the other log sizes.
Key features
- Natural Blaze burner technology: taller, livelier flames that ignite yellow immediately, with an active ember bed.
- Dual rated: vent-free heating or vented decorative use (damper clamp required for vented use).
- Oxygen depletion sensor (ODS) pilot: shuts the burner off if room oxygen drops too low.
- 26,000–37,000 BTU/h input: heats up to about 1,850 sq ft with approved log sets (Monessen rating).
- About 99% efficient: vent-free operation keeps the heat in the room.
- IntelliFire Plus (IPI) ignition: lights the pilot only when the fire is turned on, saving fuel.
- Battery operated: four AA batteries run the system, so it works during power outages; optional ACCK-IPIP 6 VDC transformer.
- Five-step flame height adjustment: set the flame and heat level from the remote.
- RC300 remote included: standard with IPI models.
- Cast iron grate included: holds the log set in its engineered position.
- Ember media included: volcanic rock and rock wool embers.
- Approved log sets: BO24-R / BO30-R Berkley Oak refractory, BO24-F / BO30-F Berkley Oak ceramic fiber, HO24-R / HO30-R Highland Oak, SC24-R / SC30-R Stony Creek, BC24-R / BC30-R Beachcomber (sold separately; one is required).
- Certified: CSA/ANSI Z21.11.2 unvented room heater and ANSI Z21.60 / CSA 2.26 vented gas log set.
Specifications
| Model | NB24NIF-B |
|---|---|
| Fuel | Natural gas (no field conversion) |
| Ignition | IntelliFire Plus (IPI), battery powered |
| Input | 37,000 BTU/h maximum, 26,000 BTU/h minimum |
| Heating capacity | Up to 1,850 sq ft (Monessen rating with approved log sets) |
| Burner size | 24 in. |
| Compatible log sets | BO24-R / BO30-R Berkley Oak refractory, BO24-F / BO30-F Berkley Oak ceramic fiber, HO24-R / HO30-R Highland Oak, SC24-R / SC30-R Stony Creek, BC24-R / BC30-R Beachcomber |
| Minimum fireplace opening | 24 in. logs: 29 x 17 x 14-1/2 in. (front width x height x depth), 23-1/4 in. rear; 30 in. logs: 33 x 17 x 14-1/2 in., 25-1/4 in. rear |
| Minimum depth | 14-1/2 in. (16-1/2 in. with a 0–3 in. restriction) |
| Gas inlet pressure | NG 5.0–10.0 in. w.c.; LP 11.0–13.0 in. w.c. |
| Electrical | 6 VDC battery pack (4 AA); no 120 VAC needed |
| Certification | CSA/ANSI Z21.11.2:19; ANSI Z21.60-2017 / CSA 2.26-2017 |
What's included
- Natural Blaze gas log burner assembly
- Cast iron grate assembly
- On/off switch and wire harness
- RC300 remote control
- Two bags of lava (volcanic) rock and one bag of rock wool
- Flex line and pipe fittings
- Fastener pack with two anchor screws
- Installation and owner's manual
Required components
- One approved Natural Blaze log set: BO24-R / BO30-R Berkley Oak refractory, BO24-F / BO30-F Berkley Oak ceramic fiber, HO24-R / HO30-R Highland Oak, SC24-R / SC30-R Stony Creek, BC24-R / BC30-R Beachcomber (sold separately)
- A natural gas supply at the rated inlet pressure, with a listed manual shutoff valve
- A suitable masonry fireplace, UL127 factory-built fireplace or Z21.91 listed vent-free firebox that meets the minimum dimensions
- C-CLAMP damper clamp for vented (decorative) installations
Optional accessories
- ACCK-IPIP 6 VDC transformer
- VR1000A volcanic rock
- CABL flat black adjustable hood (28–48 in.)
- C-CLAMP damper clamp (carton of 6)
Downloads
- Natural Blaze 18 & 24 installation and owner's manual (4663-900), includes the warranty
- Monessen vent-free gas logs brochure (MON-1004)
- Natural Blaze 24 service parts list
Installation and safety notes
⚠ Please read before you buy: this is a gas appliance. If it is not installed, adjusted, operated and maintained exactly as the manufacturer describes, it can cause a fire or explosion, or produce carbon monoxide. Monessen requires installation and service by a qualified installer, service agency or the gas supplier (Natural Blaze installation manual 4663-900, p.1). If you ever smell gas, do not try to light any appliance, do not use electrical switches or phones in the building, leave the building and call your gas supplier from a neighbor's phone.
Product specific information
- Dual listed: CSA/ANSI Z21.11.2:19 unvented room heater and ANSI Z21.60-2017 / CSA 2.26-2017 vented decorative gas log set (U.S. only). A supplemental heater, not a primary heat source (p.7).
- High altitude (U.S.): reduce input 4% for every 1,000 ft above 2,000 ft; ask your gas utility about orifice sizing (p.7).
- Equipped with an oxygen depletion sensing (ODS) pilot that shuts the burner off if room oxygen drops too low (p.7).
- Massachusetts: installation by a licensed plumber or gas fitter, a hard-wired CO detector per 248 CMR, and no installation in a bedroom or bathroom (p.8).
Getting started: fireplace size and ventilation
- Minimum fireplace depth 14-1/2 in. with no restriction, 16-1/2 in. with a 0–3 in. lintel or barrier; restrictions over 3 in. are not recommended (p.10).
- Room size: a space with less than 50 cu. ft. per 1,000 BTU/h of total appliance input is "confined" and needs added combustion air (for example, 40,000 BTU/h needs 2,000 cu. ft.) (p.11).
- Exhaust fans, range hoods, dryers and HVAC imbalance can create negative pressure that affects operation (p.11).
- Keep at least 36 in. clear in front of the opening; avoid high-traffic and drafty spots (p.10).
Important safety information
- Do not install in a bedroom or bathroom (unvented units over 10,000 BTU/h are never allowed there) (pp.1, 13).
- Never burn wood or other solid fuel on this burner; have a technician check it if flames touch the top of the firebox (pp.12–13).
- Flu-like symptoms (headache, dizziness, nausea) can signal carbon monoxide: get fresh air immediately and turn the unit off (p.13).
- Hot surfaces: supervise children and pets and keep furniture, curtains and flammables 36 in. away (p.12).
- Do not use the burner if any part has been under water (p.9).
Clearances
- Side walls: at least 9 in. from the side of the fireplace opening. Ceiling: at least 42 in. above the top of the opening (p.14).
- Wall above the opening must be non-combustible: 12 in. or more needs no hood; 8–12 in. requires the optional CABL hood; under 8 in. is not allowed (p.14).
- Combustible mantel: a 3, 6, 9 or 12 in. deep mantel needs at least 14, 17, 20 or 23 in. above the opening (8, 11, 14 or 17 in. with the optional hood) (p.15).
- Flooring: 0 in. to combustible flooring other than carpet or vinyl; no carpet or vinyl within 14 in. of the fireplace face. With vinyl, use a 14 in. hearth extension or raise the firebox 12 in.; adhesive vinyl is not recommended (pp.15–16).
- If clearances cannot be met, the burner must be installed and run as a vented appliance with the damper open (p.14).
Fireplace preparation
- Vent-free use: in a solid-fuel masonry fireplace, a UL127 factory-built fireplace, or a CSA/ANSI Z21.91 listed ventless firebox enclosure (p.17).
- Vented (decorative) use: install a damper stop such as Monessen C-CLAMP so the damper cannot close (minimum flue openings are tabled by chimney height); thermostats are not allowed; never run it with glass doors closed (pp.7, 17–18).
- Massachusetts vented installs: the damper must be removed or welded fully open (p.18).
Gas information
- Natural gas: inlet 5.0–10.0 in. w.c. (7.0 recommended), manifold 3.5 in. w.c. Propane: inlet 11.0–13.0 in. w.c. (12.0 recommended), manifold 10.0 in. w.c. (pp.7, 19).
- Use only the gas shown on the rating plate; field conversion is not permitted, so order the NG or LP model you need (p.19).
- Line pressure over 1/2 PSIG (14 in. w.c.) damages the valve; install a regulator (p.19).
Electrical information
- IntelliFire Plus (IPI) runs on 6 VDC from the battery pack (four AA batteries); no 120 VAC is needed. The optional ACCK-IPIP 6 VDC transformer is available (pp.22, 42). Replace batteries if voltage drops below 4.9 V (p.32).
- The RC300 remote is included; never wire 110–120 VAC to the control valve (pp.9, 21).
Installation, set-up and first fire
- Anchor the burner to the fireplace floor with the supplied screws so logs cannot shift (p.24).
- Use only an approved log set and the supplied lava rock and rock wool; do not add embellishments (p.25).
- Break-in: run on high for three to four hours with windows open; odor from curing paint and oils is normal. After a 15-minute warm-up, yellow flames should not touch the logs (p.26).
- Annual inspection and service by a qualified technician (p.29).
Building code information
- Install to local codes; where none exist, follow the current NFPA 54 / ANSI Z223.1 National Fuel Gas Code or the International Fuel Gas Code (IFGC); in Canada, CSA B149.1 Natural Gas and Propane Installation Code (Canada) (pp.7, 19).
- Electrical work: NFPA 70 National Electrical Code (p.21).
- Massachusetts: 248 CMR 5.00 (Massachusetts amendments to NFPA 54), with CO detection per NFPA 720 / UL 2034 (p.8).
Warranty
- Coverage is the Hearth & Home Technologies (HHT) Limited Lifetime Warranty, form 4021-645N (12/23), printed in the Natural Blaze installation and owner's manual (4663-900), pp.4–5. Monessen is an HHT brand.
- Vented and vent-free burners and logs: 5 years (the row that applies to burners and log sets like this one).
- All parts and material, including handles and external enameled components: 1 year parts and labor (subject to the warranty conditions and exclusions).
- Electrical components (modules, remotes and wall switches, valves, pilots, blowers, junction boxes, wire harnesses, transformers and lights, excluding bulbs): 2 years.
- Purchased replacement parts and optional accessories: 1 year parts, no labor.
- Who is covered: products bought from an HHT authorized dealer or distributor. Coverage transfers to later owners while the product stays at its original installation site, but the period is not extended. Valid only in the country where the selling dealer is authorized.
- When coverage starts: on the date of installation (new construction: six months after the final sale invoice, and no later than 24 months after HHT ships the product).
- How service works: warranty service is arranged through the installing dealer or distributor. Travel and parts-shipping charges are not covered.
- Key exclusions: normal wear items (paint, gaskets, firebricks, grates, flame guides, batteries, glass discoloration), normal finish color changes and cosmetic damage, noise from normal expansion and contraction, and damage from improper installation, operation or maintenance, code violations, inadequate ventilation, unauthorized modifications or a fuel other than the one specified. HHT does not guarantee heating capacity for a given space.
- The warranty is void if the product is over-fired, operated in a chemically contaminated atmosphere, or damaged by prolonged dampness, condensation or water.
California Proposition 65
WARNING: This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Loading component details…