Majestic Quartz 36" Direct Vent Gas Fireplace TBSC36
SKU / Model: TBSC36N
Fireplace only$2,089.00
Early Black Friday Savings applied in your cart
Unlock an exclusive offer on this product.
Product overview
The Majestic Quartz 36" (TBSC36) is the redesigned Quartz direct vent gas fireplace: a slim, budget-friendly traditional fireplace with glowing embers behind tempered glass and IntelliFire Touch ignition with battery backup.
The fireplace is sold as a firebox. Majestic requires a front and a log set to complete it, all sold separately: choose the Contemporary Rectangular Door (Black or New Bronze) or the Decorative Black Mesh front, and the Traditional or Birch log set. Reflective black glass or Tavern Brown brick interior panels are optional.
Input is 13,000-25,000 BTU/h on natural gas and 11,500-23,500 BTU/h on propane.
It vents through the top with SLP or SLP-Flex pipe or through the rear with DVP pipe, and it is approved for the PVLP-SLP, PVI-SLP-B and PVV-SLP power vents with the power vent wire harness and IFT-RC400 remote.
The Quartz series comes in 32, 36 and 42 in. sizes; the Quartz Platinum version adds the touchscreen remote, variable-speed fan, LED embers and ceramic glass as standard.
Key features
- Direct vent: Sealed combustion uses outside air and vents outdoors.
- IntelliFire Touch ignition: With battery backup.
- Optional controls: IFT-RC400 touchscreen remote, IFT-RC150 wireless wall switch, IFT-WFM Wi-Fi module, BATTERY-WSK wall switch.
- Optional fan: 160 CFM fan kit, fan only or with rheostat and temperature sensor.
- Glowing embers and tempered glass.
- Two front styles: Contemporary Rectangular Door (Black or New Bronze) or Decorative Black Mesh, sold separately and required.
- Two log sets: Traditional or Birch, sold separately and required.
- Interior options: Reflective black glass or Tavern Brown brick panels.
- Top or rear venting: SLP or SLP-Flex top, DVP rear; power vent approved.
- Trim kits: 3-sided or 4-sided black trim kits.
- Heat management: Heat-Zone and Heat-Out kits available.
- Dynamic Thermostat: Majestic lists Dynamic Thermostat, which lowers the flame as the room warms, for the Quartz series.
Specifications
| Model | TBSC36N (natural gas) / TBSC36L (propane) |
|---|---|
| Type | Direct vent gas fireplace, top or rear vent |
| Input, natural gas | 13,000-25,000 BTU/h |
| Input, propane | 11,500-23,500 BTU/h |
| Ignition | IntelliFire Touch, battery backup |
| Glass | Tempered |
| Embers | Glowing embers |
| Viewing area | 32-1/16 x 21-1/2 in. |
| Vent collars | 4 x 6-5/8 in. top, 5 x 8 in. rear |
| Venting | SLP or SLP-Flex (top), DVP (rear); PVLP-SLP, PVI-SLP-B, PVV-SLP power vents |
| Electrical | Unswitched 110-120 VAC circuit, minimum 14-2 AWG with ground; 6 V IntelliFire valve powered by the 6 V transformer or 4 AA batteries (not included); junction box included |
| Gas pressure, natural gas | Inlet 5.0 in. w.c. minimum, 10.0 in. w.c. maximum; manifold 3.5 in. w.c. |
| Gas pressure, propane | Inlet 11.0 in. w.c. minimum, 13.0 in. w.c. maximum; manifold 10.0 in. w.c. |
| Certification | Listed by Underwriters Laboratories (UL) as a direct vent heater to CSA/ANSI Z21.88-2019 / CSA 2.33-2019; certified for bedroom or bedsitting-room installation |
| Overall width | 41 in. |
| Framing width | 42 in. |
| Framing height | 38-1/4 in. |
| Framing depth | 16-1/4 in. |
Dimensions and clearances
- Viewing area 32-1/16 x 21-1/2 in.; framing width 42 in.; framing height 38-1/4 in.; framing depth 16-1/4 in. (Majestic Quartz Series specifications; installation manual 2641-980, Fig. 3.4).
- Overall width 41 in. (installation manual 2641-980, Fig. 3.1).
- Exterior chase: at least 46-1/4 in. from the bottom of the fireplace to a combustible surface above (installation manual 2641-980).
- Combustible flooring may not be more than 1 in. above the base of the fireplace. Set the fireplace on a hard metal or wood surface that runs its full width and depth.
- Vent pipe clearance to combustibles: 3 in. above horizontal runs, 1 in. at the bottom and sides.
- Combustible materials above the fireplace: at least 15 in. above the top of the unit, or at least 12 in. with the elbow heat shield installed (installation manual 2641-980, Sec. 6.A).
What's included
- Quartz 36 firebox with IntelliFire Touch ignition system
- Tempered glass
- Glowing embers
- External air shutter adjustment
- 12 ft control wire
- Battery backup
- Gas flex connector with shut-off valve
- Junction box
- 4 x 6-5/8 in. top vent collar and 5 x 8 in. rear vent collar
Required components
- Front: Contemporary Rectangular Door (Black or New Bronze) or Decorative Black Mesh
- Log set: Traditional or Birch
- Quartz 36 requires a direct vent (SLP top vent or DVP rear vent) venting system, not included with purchase.
Optional accessories
- Reflective black glass or Tavern Brown brick interior panels
- 160 CFM fan kit (fan only, or with rheostat and temperature sensor)
- IFT-RC400 touchscreen remote
- IFT-RC150 wireless wall switch
- IFT-WFM Wi-Fi module for the IntelliFire app
- Battery backup wall switch kit
- IFT-ACM AUX module (only needed for a fan, lights or power vent run from the Wi-Fi module without an IFT-RC400)
- 3-sided or 4-sided black trim kit
- Heat-Zone kit (up to two) or Heat-Out kit
- Exterior Heat-Zone brick extension kit
- PVLP-SLP, PVI-SLP-B or PVV-SLP power vent
- Majestic flush mantels and mantel shelves sized for the Quartz 36
Downloads
- Quartz 32/36/42 installation manual 2641-980 Rev N (written for the earlier QUARTZ IFT models; clearances, electrical, gas and venting data)
- Majestic Quartz Series product page and specifications (majesticproducts.com)
- Mantels, shelves and surrounds brochure FSF-1016U
- Inline power vent PVI-SLP-B instructions 2196-902 Rev Y (lists the Quartz TBSC models)
- Vertical power vent PVV-SLP instructions 4071-900 Rev O (lists the Quartz TBSC models)
Installation and safety notes
⚠ Important: this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Have it installed and serviced by a qualified installer, service agency or gas supplier, following the Majestic installation manual and local codes. If you ever smell gas, do not light any appliance, do not use electrical switches or phones in the building, leave the building and call your gas supplier from a neighbor's phone.
Site and installation requirements
- Order the model that matches your fuel: N = natural gas, L = propane.
Front, logs and panels
- Majestic lists the front and the log set as required to complete the fireplace; all are sold separately.
- Never operate the fireplace without its decorative front installed; the front prevents contact with the hot glass (installation manual 2641-980, p.65).
- High altitude: in the U.S., reduce input 4% for each 1,000 ft above 2,000 ft; in Canada the ratings apply without reduction up to 4,500 ft (installation manual 2641-980, Sec. 1.D).
Termination location & vent information
- Top venting uses Hearth & Home SLP or SLP-Flex pipe; rear venting uses DVP pipe (Majestic price book, venting notes).
- Approved power vents: PVLP-SLP, PVI-SLP-B and PVV-SLP, each with the power vent wire harness and the IFT-RC400 remote (ordered separately).
- With the PVV-SLP vertical power vent, the Quartz needs at least 5 ft of straight pipe between the fireplace and the power vent (HHT instructions 4071-900 Rev O, Table 2.1).
- Top vent: up to 60 ft straight vertical; the total vent run (vertical plus horizontal) may not exceed 40 ft; an exhaust restrictor may be needed when the total vertical is 15-60 ft (installation manual 2641-980, Sec. 4).
Building code information
- Gas installation: follow local codes or, where none apply, the current National Fuel Gas Code, ANSI Z223.1/NFPA 54 (U.S.) or the CSA B149.1 Natural Gas and Propane Installation Code (Canada)
- Electrical: wire and ground to local codes or, where none apply, the National Electrical Code, ANSI/NFPA 70 (U.S.) or the CSA C22.1 Canadian Electrical Code (Canada)
- Massachusetts: installation by a licensed plumber or gas fitter under the Massachusetts fuel gas code (248 CMR); side-wall vents under 7 ft need a hard-wired CO detector with battery backup meeting NFPA 720 and ANSI/UL 2034
- Non-combustible materials are defined by ASTM E136 (published by ASTM International)
Warranty
- Covered by the Hearth & Home Technologies (HHT) limited warranty; Majestic is an HHT brand.
California Proposition 65
WARNING: This product and the fuels used to operate this product (liquid propane or natural gas), and the products of combustion of such fuels, can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Loading component details…
Add to cart to see your price.
