Product overview
The Majestic Pioneer III (PIONEER-III-REC) is Majestic's largest EPA-certified wood-burning fireplace, made to heat a whole home. This listing is the rectangular-door version: a welded steel firebox with a single cast-iron rectangular door, finished with a decorative front you choose separately.
The 4.1 cu. ft. firebox holds logs up to 24 in. Majestic rates it for 1,200 to 3,000 sq. ft., with up to 85,175 BTU/h at peak, 73% (LHV) efficiency and only 1.3 g/hr emissions, so it meets the strictest EPA 2020 standard.
Smart Burn Technology takes the guesswork out of wood heat: press the button to start, and the fireplace opens the air for a hot start, then adjusts itself for a clean, efficient burn, which Majestic says can cut home heating costs by up to 50%. A green light tells you when it is time to reload, and eight D-cell batteries keep the air control working in a power outage.
A 400 CFM two-fan system with a speed knob moves the heat into the room, and up to two Heat-Zone kits can duct warmth to other rooms. It uses the SL300 chimney system or 8 in. DuraPlus, needs outside combustion air and a fan air kit, and is approved for manufactured homes.
Compared with the Pioneer II and WarmMajic II (2.75 cu. ft., manual combustion control), the Pioneer III offers a much bigger firebox, longer logs and automatic Smart Burn control.
Key features
- 4.1 cu. ft. firebox: Holds logs up to 24 in. for overnight heating (manual p.4).
- Smart Burn Technology: Automatic air control for an efficient, clean burn; one-button start and reload light (owner's manual).
- Battery backup: Eight D-cell batteries keep Smart Burn working without 110 V (fans need power).
- EPA 2020 certified: 1.3 g/hr; 73% LHV / 68% HHV efficiency (p.4).
- Heat output: 18,000 BTU/h EPA; 85,175 BTU/h peak; heats 1,200-3,000 sq. ft.
- 400 CFM fan system: Two convection fans with a speed knob; speed follows fireplace temperature.
- Heat-Zone ready: Up to two Heat-Zone-WD-C kits for multi-room heating.
- Cast-iron door: Single cast-iron rectangular door with 5 mm ceramic glass.
- Front choices: mission rectangular front DF-PIII-MR, classic black (required, sold separately).
- Viewing area: 341 sq. in. (majesticproducts.com).
- Outside air and fan air kits: Outside combustion air required; fan air kit grille included.
- Manufactured-home approved: UL 127, CAN/ULC-S610, (UM) 84-HUD.
Specifications
| Model | PIONEER-III-REC |
|---|---|
| Type | Factory-built EPA wood-burning fireplace |
| Unit dimensions | 63-1/4" H; weight 680 lb; width and depth are drawn in Fig. 3.1 but not published by the manufacturer as labeled values (install manual 4182-903 p.10) |
| Framing dimensions | Finished cavity depth at least 24-1/2"; chase about 75" tall inside, with 12" per side added for the outside-air and fan ducts; framing width and height not published as labeled values (Section 3, p.13) |
| Viewing area | 341 sq in (Majestic specification); W x H not published as labeled values |
| Clearances to combustibles | Back 1"; sides 1-1/2"; top of fireplace to header 16"; top of appliance to ceiling 36"; faceplate to side wall 16"; floor 0"; Heat-Zone grilles 12" to the ceiling (p.11); combustible mantel at least 66" above the base and non-combustible at least 46", 12" maximum depth, with 62" from the bottom of the fireplace to the lower edge of a mantel or trim (pp.11, 38-39); hearth extension 20" in front and 8" to each side of the fuel opening (42" x 20"), R-value 1.03 minimum (pp.40-41) |
| Door | Single cast-iron rectangular door |
| Firebox | 4.06 cu. ft.; logs up to 24 in. |
| Output | 18,000 BTU/h EPA; 85,175 BTU/h peak |
| Heating capacity | 1,200-3,000 sq. ft. |
| Efficiency | 73% LHV / 68% HHV |
| Emissions | 1.3 g/hr (EPA 2020) |
| Chimney | 8 in. SL300 (with CAK4A) or 8 in. DuraPlus |
| Electrical | 110-120 VAC; 8 x D-cell battery backup for Smart Burn |
| Glass | 5 mm ceramic |
| Weight | 680 lb |
| Listings | UL 127-2011, CAN/ULC-S610-2018, (UM) 84-HUD |
What's included
- Pioneer III welded steel firebox
- Single cast-iron rectangular door, classic black
- Smart Burn Technology control
- 400 CFM fan system
- Fan air kit grille
- CAK4A chimney air kit
- Outside air hood
- Attic insulation shield
- Installation and owner's manuals
Required components
- Front: Mission Rectangular front (Black)
- Fan air kit duct: 6-inch flex venting
- Pioneer III requires an SL300 chimney or 8-inch DuraPlus venting system, not included with purchase.
Optional accessories
- HEAT-ZONE-WD-C heat distribution kit (up to two)
- TMP-PIIIR reusable metal finishing template
Downloads
- Pioneer III installation manual 4182-903, Rev D 2/26
- Pioneer III owner's manual and warranty 4182-902, Rev E 12/25
- Majestic wood-burning fireplace product guide
Installation and safety notes
⚠ Important: this is a wood-burning fireplace. Improper installation, venting or use can cause a house fire or carbon-monoxide exposure. Majestic requires installation by a qualified installer following the installation manual and local building codes (install manual 4182-903), and the chimney should be inspected regularly. Burn only dry, seasoned wood, never use flammable liquids to start or freshen a fire, and keep children and furniture away from hot surfaces.
Site and installation requirements
- 6-inch UL 181 Class 0/1 outside-air duct (installer supplied).
Product & safety information
- Listed to UL 127-2011 and CAN/ULC-S610-2018 as a factory-built wood fireplace; (UM) 84-HUD approved for manufactured homes (not in a sleeping room, outside air required, frame grounded) (install manual 4182-903 pp.4-5).
- Certified to the EPA 2020 particulate standard: 1.3 g/hr; 73% LHV / 68% HHV efficiency (p.4).
- Do not modify the fireplace, install unapproved parts, or install an unvented gas log set. Use only 5 mm ceramic replacement glass (pp.4-5).
- Over-firing voids the warranty (p.5).
Getting started
- Plan the location, chase and chimney route first; installation by a qualified installer is required (pp.6-9).
- Majestic requires Advanced Technology Product training for the installing dealer before this model ships (2026 price book).
Framing & clearances
- Appliance weight: 680 lb (Section 3, Fig. 3.1).
- Clearances to combustibles: back 1 in. (Section 3.E lists 1/2 in.; confirm with the drawing), sides 1-1/2 in., 16 in. from the top of the fireplace to the header, 36 in. from the top of the appliance to the ceiling, 0 in. to the floor (Section 3).
- Door opening to a side wall 22-3/4 in.; faceplate to a side wall 16 in.; keep electrical wiring at least 16 in. above the top (Section 3).
- Finished cavity depth at least 24-1/2 in. from the finished back wall to the outside of the front framing; never pack insulation into the air spaces (Section 3).
- Outside combustion air is required: the kit is factory installed on the right (movable to the left); 6 in. UL 181 Class 0/1 duct (not supplied), 36 in. to 40 ft run, inlet hood clear of snow and debris and away from exhausts, garages and attics (Section 3).
- A fan air kit is required: 6 in. duct, 36 in. to 40 ft, up to four 90-degree elbows; the fan air grille and 10 x 4 x 6 duct boot are included (Section 3).
Electrical
- 110-120 VAC circuit for the fans, GFCI protected in damp locations; wire and ground to the NEC/NFPA 70 (CSA C22.1 in Canada) and complete the wiring before the enclosure is closed (p.23).
- Smart Burn Technology runs on 110 V with a battery backup of eight D-cells (the fans do not run on batteries) (owner's manual).
Chimney and termination
- Approved chimney: SL300 Series (8 in.) with the CAK4A chimney air kit, or 8 in. DuraPlus with the 8DP-BP base plate (no CAK4A); use the DV-6DP-IS attic insulation shield with DuraPlus (manual Section 5; price book).
- Minimum height 13 ft straight, 14.5 ft with one offset/return, 20 ft with two; maximum 90 ft (Section 5).
- Offsets: up to two pairs, no more than 30 degrees from vertical (SL315 / SL330); maximum 20 ft between an offset and its return; support at least every 35 ft; maximum 6 ft unsupported above the roof (Section 5).
- Termination: the bottom of the listed cap must be at least 3 ft above the roof and 2 ft above anything within 10 ft (Section 5).
- Firestops at every ceiling, an attic insulation shield in insulated attics, roof flashing (RF370 for flat to 6/12, RF371 for 6/12 to 12/12) and a non-combustible chase top with a 2 in. collar (Section 6).
Finishing
- Hearth extension: non-combustible, at least 20 in. in front of the fuel opening and 8 in. to each side, insulated to R 1.03 minimum (HX4 Micore or 2 in. cement board); raised hearths on the floor up to 6-1/4 in. without a platform (Section 8).
- Mantels: combustible no lower than 66 in. above the base of the fireplace, non-combustible no lower than 46 in., both up to 12 in. deep; trim up to 3/4 in. thick at least 6 in. from the side of the front (Section 8).
- Use only non-combustible materials on the face near the minimum clearances; a vinyl floor in front of the hearth needs a 48 in. minimum hearth depth (Section 8).
Fireplace setup
- Check that the firebrick, baffle and ceramic blanket are in place before the first fire; the fascia/front must be installed and removable for service (Section 9).
Break-in and everyday use
- Keep the first three or four fires moderate so the paint and refractory can cure; a temporary odor is normal (owner's manual).
- Burn only seasoned cordwood split to 6 in. or less, under 20% moisture, logs up to 24 in.; never burn garbage, treated wood, cardboard or plastics, and never use flammable liquids (owner's manual).
- Glass and surfaces get very hot: supervise children closely and keep furniture and drapes at least 4 ft from the front (owner's manual).
- Remove ashes only when cold, into a metal container with a tight lid placed on a non-combustible surface (owner's manual).
Building code information
- Chimney and installation: follow local codes; where none apply, NFPA 211 (Standard for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances) in the U.S. or CAN/CSA-B365 in Canada
- Electrical: wire and ground to local codes or, where none apply, the National Electrical Code, ANSI/NFPA 70 (U.S.) or the CSA C22.1 Canadian Electrical Code (Canada)
- Manufactured (mobile) homes: OEM installation to the Manufactured Home Construction and Safety Standard, Title 24 CFR Part 3280 (U.S.) or CAN/CSA Z240 MH Series (Canada)
- Non-combustible materials are defined by ASTM E136 (published by ASTM International)
- The ducting for outside air and fan air must be UL 181 Class 0 or Class 1 material
Warranty
- Coverage is the Hearth & Home Technologies (HHT) Limited Lifetime Warranty, form 4021-645N (12/23), printed in the Pioneer III owner's manual 4182-902, pp.4-5. Majestic is an HHT brand.
- Firebox and heat exchanger: 20 years parts, 3 years labor.
- Castings, medallions and baffles, manifolds, and HHT chimney and terminations: 10 years parts, 3 years labor.
- Electrical components (fans, wiring, switches, junction box): 2 years.
- Cement refractory and glass liner panels: 2 years.
- All parts and material, including handles and external enameled components: 1 year parts and labor (subject to the conditions and exclusions).
- Purchased replacement parts and optional accessories: 1 year parts, no labor.
- Who is covered: products bought from an HHT authorized dealer or distributor. Coverage transfers to later owners while the fireplace stays at its original installation site, but the period is not extended. Valid only in the country where the selling dealer is authorized.
- When coverage starts: on the date of installation (new construction: six months after the final sale invoice, and no later than 24 months after HHT ships the product).
- How service works: through the installing dealer or distributor; travel and parts-shipping charges are not covered.
- Key exclusions: normal wear items (paint, gaskets, firebricks, grates, flame guides, batteries, glass discoloration), normal finish color changes, damage from improper installation, operation or maintenance, non-HHT components, unauthorized modifications, fuels other than seasoned wood, and power fluctuations. HHT does not guarantee heating capacity for a given space.
- The warranty is void if the fireplace is over-fired (signs include a warped air tube, damaged baffle or deteriorated refractory retainers), exposed to chlorine or other damaging chemicals, or damaged by prolonged dampness, condensation or water from an improper chimney installation.
California Proposition 65
WARNING: This product can expose you to chemicals including soot and carbon monoxide, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Frequently asked questions — PIONEER-III-REC
What framing does the PIONEER-III-REC need?
The finished cavity must be at least 24-1/2" deep, and the chase is about 75" tall inside, with 12" added on each side for the outside-air and fan ducts. Keep 1" at the back, 1-1/2" at the sides, 16" from the top of the fireplace to the header and 36" from the top of the appliance to the ceiling; the floor can be 0". The fireplace is 63-1/4" tall.
What chimney does it use, and how tall must it be?
An 8" SL300 chimney with the CAK4A chimney air kit, or 8" DuraPlus with its base plate. The chimney must be at least 13 ft straight, 14.5 ft with one offset and return, or 20 ft with two, and no taller than 90 ft. Offsets can be up to 30° from vertical, with no more than 20 ft of pipe between an offset and its return.
Does it need an outside air kit?
Yes. The outside air kit is required, with up to 40 ft of 6" UL181 duct (duct not supplied) and at least 17.5 sq in of inlet area. The fan air kit is also required, ducted with 6" B-vent from 36" up to 40 ft long.
How much does it heat?
Majestic rates the Pioneer III for 1,200 to 3,000 sq ft, with 85,175 BTU/h peak output and 18,000 BTU/h on the EPA test. The 4.06 cu ft firebox takes logs up to 24", and one or two optional Heat-Zone kits can duct heat to other rooms.
Does it work in a power outage?
Yes. Eight D-cell batteries keep the Smart Burn air control working when the power is out, and the wood fire itself needs no electricity. The 400 CFM fans run on 110-120 VAC and stop until power returns.
How high must a mantel be, and what hearth does it need?
A combustible mantel must be at least 66" above the base and a non-combustible one at least 46", both no deeper than 12". The non-combustible hearth extension must reach 20" in front and 8" to each side of the fuel opening (42" × 20") with an R-value of at least 1.03.