Majestic Pioneer II Wood Burning Fireplace PIONEER-II
SKU / Model: PIONEER-II-ARC
Fireplace only$6,649.00
Black Friday Savings applied in your cart
Unlock an exclusive offer on this product.
Product overview
The Majestic Pioneer II is an EPA-certified wood-burning fireplace designed to heat a home, not just decorate it. A welded steel firebox, a classic black front and a single cast-iron door give it a traditional hearth look, and you choose the door style: arch (PIONEER-II-ARC) or rectangle (PIONEER-II-REC).
The 2.75 cu. ft. firebox holds logs up to 22 in., and Majestic says a single load can keep flames going for up to eight hours. Output is 20,900 BTU/h (EPA) and up to 81,000 BTU/h at peak, at 73% (LHV) efficiency with just 1.7 g/hr emissions.
Automatic Combustion Control makes it easy: engage it to start the fire hot, then the fireplace holds the burn rate you set, with an override lever to slow it down quickly. Two convection fans with speed control come standard and switch on automatically once the fireplace is warm.
Heat-Zone kits (one or two) can duct warm air to other rooms. The Pioneer II vents through the SL300 chimney system or 8 in. DuraPlus, needs outside combustion air, and is approved for manufactured homes.
It shares its firebox and burn system with the WarmMajic II but adds the cast-iron door choice; for more heat and a bigger firebox, see the Pioneer III with Smart Burn Technology.
Key features
- 2.75 cu. ft. firebox: Holds logs up to 22 in.; up to eight hours from one load (majesticproducts.com; manual p.4).
- Choose your door: Single cast-iron arch door (ARC) or rectangle door (REC) on a classic black front.
- EPA 2020 certified: 1.7 g/hr; 73% LHV / 69% HHV efficiency (p.4).
- Heat output: 20,900 BTU/h EPA; 81,000 BTU/h peak (p.4).
- Automatic Combustion Control: Starts the fire hot and then holds your chosen burn rate; override lever behind the lower access panel (owner's manual).
- Dual fans with speed control: Temperature-activated convection fans with wall override switch and speed control.
- Heat-Zone ready: Optional Heat-Zone-WD-C kits (up to two) for multi-room heating.
- Outside combustion air: Required outside air kit, factory installed on the right side.
- Ceramic glass: 5 mm ceramic glass door; operate with the door fully closed.
- Manufactured-home approved: UL 127, CAN/ULC-S610, (UM) 84-HUD.
- Included chimney parts: CAK4A chimney air kit, outside air hood and attic insulation shield (price book).
Specifications
| Models | PIONEER-II-ARC (arch door), PIONEER-II-REC (rectangle door) |
|---|---|
| Type | Factory-built EPA wood-burning fireplace |
| Unit dimensions | Not published by the manufacturer as labeled values (Fig. 3.1 drawing, install manual 4184-903 p.10); weight 617 lb |
| Framing dimensions | Finished cavity depth at least 24"; chimney cavity 14-1/2" (SL300) or 16" (DuraPlus); at least 12" of cavity width for the outside air duct; the framing drawing (Fig. 3.5, p.13) shows 56-3/4", 48-1/2" and 42-1/2" without width/height labels |
| Viewing area | Not published by the manufacturer as labeled values |
| Clearances to combustibles | Back 1/2"; sides 1"; top of fireplace to header 16"; top of appliance to ceiling 36"; door opening to side wall 22-3/4"; faceplate to side wall 16"; floor 0"; Heat-Zone grilles 12" to the ceiling; chimney 2" to framing and insulation (pp.11-12); combustible mantel at least 60" above the base and non-combustible at least 38", 12" maximum depth (p.38); hearth extension 20" in front and 8" to each side of the fuel opening (41" x 20"), insulated to R 1.03, raised hearth up to 5-3/4" without a platform; vinyl floor in front needs a 48" hearth depth (pp.13, 39-40) |
| Firebox | 2.75 cu. ft.; logs up to 22 in. |
| Output | 20,900 BTU/h EPA; 81,000 BTU/h peak |
| Burn time | Up to 8 hours per load (Majestic) |
| Efficiency | 73% LHV / 69% HHV |
| Emissions | 1.7 g/hr (EPA 2020) |
| Chimney | 8 in. SL300 (with CAK4A) or 8 in. DuraPlus |
| Electrical | 110-120 VAC for the fans |
| Glass | 5 mm ceramic |
| Weight | 617 lb |
| Listings | UL 127-2011, CAN/ULC-S610-2018, (UM) 84-HUD |
What's included
- Pioneer II welded steel firebox
- Classic black front with single cast-iron arch or rectangle door
- Dual fans with speed control
- Automatic Combustion Control
- CAK4A chimney air kit
- Outside air hood
- Attic insulation shield
- Installation and owner's manuals
Required components
- Unit is complete — no required options needed.
- Pioneer II requires an SL300 chimney or 8-inch DuraPlus venting system, not included with purchase.
Optional accessories
- HEAT-ZONE-WD-C heat distribution kit (up to two)
- TMP-MED-ARC or TMP-MED-REC metal finishing template
- LINTELBAR-HHT lintel bar
- OA-RD-6 outside air elbow kit
Downloads
- Pioneer II installation manual 4184-903, Rev D 2/26
- Pioneer II owner's manual and warranty 4184-902, Rev E 12/25
- Pioneer II architect's guide
- Majestic wood-burning fireplace product guide
Installation and safety notes
⚠ Important: this is a wood-burning fireplace. Improper installation, venting or use can cause a house fire or carbon-monoxide exposure. Majestic requires installation by a qualified installer following the installation manual and local building codes (install manual 4184-903), and the chimney should be inspected regularly. Burn only dry, seasoned wood, never use flammable liquids to start or freshen a fire, and keep children and furniture away from hot surfaces.
Site and installation requirements
- 6-inch UL 181 Class 0/1 outside-air duct (installer supplied).
Product & safety information
- Listed to UL 127-2011 and CAN/ULC-S610-2018 as a factory-built wood fireplace; (UM) 84-HUD approved for manufactured homes (not in a sleeping room, outside air required, frame grounded) (install manual 4184-903 pp.4-5).
- Certified to the EPA 2020 particulate standard: 1.7 g/hr; 73% LHV / 69% HHV efficiency (p.4).
- Do not modify the fireplace, install unapproved parts, or install an unvented gas log set. Use only 5 mm ceramic replacement glass (pp.4-5).
- Over-firing voids the warranty (p.5).
Getting started
- Plan the location, chase and chimney route first; installation by a qualified installer is required (pp.6-9).
- Majestic requires Advanced Technology Product training for the installing dealer before this model ships (2026 price book).
Framing & clearances
- Appliance weight: 617 lb (arch and rectangle) (p.10).
- Clearances to combustibles: back 1/2 in., sides 1 in., 16 in. from the top of the fireplace to the header, 36 in. from the top of the appliance to the ceiling, 0 in. to the floor (pp.11-12).
- Door opening to a side wall 22-3/4 in.; faceplate to a side wall 16 in.; keep electrical wiring at least 16 in. above the top (pp.11-12).
- Finished cavity depth at least 24 in. from the finished back wall to the outside of the front framing; never pack insulation into the air spaces (pp.12-13).
- Outside combustion air is required: the kit is factory installed on the right (movable to the left); 6 in. UL 181 Class 0/1 duct (not supplied), 36 in. to 40 ft run, inlet hood clear of snow and debris and away from exhausts, garages and attics (pp.15-17).
Electrical
- 110-120 VAC circuit for the fans, GFCI protected in damp locations; wire and ground to the NEC/NFPA 70 (CSA C22.1 in Canada) and complete the wiring before the enclosure is closed (p.22).
Chimney and termination
- Approved chimney: SL300 Series (8 in.) with the CAK4A chimney air kit, or 8 in. DuraPlus with the 8DP-BP base plate (no CAK4A); use the DV-6DP-IS attic insulation shield with DuraPlus (manual Section 5; price book).
- Minimum height 13 ft straight, 14.5 ft with one offset/return, 20 ft with two; maximum 90 ft (Section 5).
- Offsets: up to two pairs, no more than 30 degrees from vertical (SL315 / SL330); maximum 20 ft between an offset and its return; support at least every 35 ft; maximum 6 ft unsupported above the roof (Section 5).
- Termination: the bottom of the listed cap must be at least 3 ft above the roof and 2 ft above anything within 10 ft (Section 5).
- Firestops at every ceiling, an attic insulation shield in insulated attics, roof flashing (RF370 for flat to 6/12, RF371 for 6/12 to 12/12) and a non-combustible chase top with a 2 in. collar (Section 6).
Finishing
- Hearth extension: non-combustible, at least 20 in. in front of the fuel opening and 8 in. to each side, insulated to R 1.03 minimum (HX4 Micore or 2 in. cement board); raised hearths on the floor up to 5-3/4 in. without a platform (Section 8).
- Mantels: combustible no lower than 60 in. above the base of the fireplace, non-combustible no lower than 38 in., both up to 12 in. deep; trim up to 3/4 in. thick at least 6 in. from the side of the front (Section 8).
- Use only non-combustible materials on the face near the minimum clearances; a vinyl floor in front of the hearth needs a 48 in. minimum hearth depth (Section 8).
Fireplace setup
- Check that the firebrick, baffle and ceramic blanket are in place before the first fire; the fascia/front must be installed and removable for service (Section 9).
Break-in and everyday use
- Keep the first three or four fires moderate so the paint and refractory can cure; a temporary odor is normal (owner's manual).
- Burn only seasoned cordwood split to 6 in. or less, under 20% moisture, logs up to 22 in.; never burn garbage, treated wood, cardboard or plastics, and never use flammable liquids (owner's manual).
- Glass and surfaces get very hot: supervise children closely and keep furniture and drapes at least 4 ft from the front (owner's manual).
- Remove ashes only when cold, into a metal container with a tight lid placed on a non-combustible surface (owner's manual).
Building code information
- Chimney and installation: follow local codes; where none apply, NFPA 211 (Standard for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances) in the U.S. or CAN/CSA-B365 in Canada
- Electrical: wire and ground to local codes or, where none apply, the National Electrical Code, ANSI/NFPA 70 (U.S.) or the CSA C22.1 Canadian Electrical Code (Canada)
- Manufactured (mobile) homes: OEM installation to the Manufactured Home Construction and Safety Standard, Title 24 CFR Part 3280 (U.S.) or CAN/CSA Z240 MH Series (Canada)
- Non-combustible materials are defined by ASTM E136 (published by ASTM International)
- The ducting for outside air and fan air must be UL 181 Class 0 or Class 1 material
Warranty
- Coverage is the Hearth & Home Technologies (HHT) Limited Lifetime Warranty, form 4021-645N (12/23), printed in the Pioneer II owner's manual 4184-902, pp.4-5. Majestic is an HHT brand.
- Firebox and heat exchanger: 20 years parts, 3 years labor.
- Castings, medallions and baffles, manifolds, and HHT chimney and terminations: 10 years parts, 3 years labor.
- Electrical components (fans, wiring, switches, junction box): 2 years.
- Cement refractory and glass liner panels: 2 years.
- All parts and material, including handles and external enameled components: 1 year parts and labor (subject to the conditions and exclusions).
- Purchased replacement parts and optional accessories: 1 year parts, no labor.
- Who is covered: products bought from an HHT authorized dealer or distributor. Coverage transfers to later owners while the fireplace stays at its original installation site, but the period is not extended. Valid only in the country where the selling dealer is authorized.
- When coverage starts: on the date of installation (new construction: six months after the final sale invoice, and no later than 24 months after HHT ships the product).
- How service works: through the installing dealer or distributor; travel and parts-shipping charges are not covered.
- Key exclusions: normal wear items (paint, gaskets, firebricks, grates, flame guides, batteries, glass discoloration), normal finish color changes, damage from improper installation, operation or maintenance, non-HHT components, unauthorized modifications, fuels other than seasoned wood, and power fluctuations. HHT does not guarantee heating capacity for a given space.
- The warranty is void if the fireplace is over-fired (signs include a warped air tube, damaged baffle or deteriorated refractory retainers), exposed to chlorine or other damaging chemicals, or damaged by prolonged dampness, condensation or water from an improper chimney installation.
California Proposition 65
WARNING: This product can expose you to chemicals including soot and carbon monoxide, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Frequently asked questions — PIONEER-II
What framing does the PIONEER-II need?
The finished cavity must be at least 24" deep, with a 14-1/2" chimney cavity for SL300 (16" for DuraPlus) and at least 12" of extra width for the outside air duct. Keep 1/2" at the back, 1" at the sides, 16" from the top of the fireplace to the header and 36" from the top of the appliance to the ceiling; the floor can be 0".
What chimney does it use, and how tall must it be?
An 8" SL300 chimney with the CAK4A chimney air kit, or 8" DuraPlus with its base plate. The chimney must be at least 13 ft straight, 14.5 ft with one offset and return, or 20 ft with two, and no taller than 90 ft. Offsets can be up to 30° from vertical, and the cap must sit at least 3 ft above the roof and 2 ft above any roof within 10 ft.
Does it need an outside air kit?
Yes. The outside air kit is required and comes factory installed on the right side (it can move to the left). It runs 6" UL181 duct from 36" up to 40 ft, with an inlet hood of at least 17.5 sq in.
How much does it heat?
It puts out 81,000 BTU/h peak and 20,900 BTU/h on the EPA test at 73% LHV efficiency. The 2.75 cu ft firebox takes logs up to 22", and one or two optional Heat-Zone-WD-C kits can duct heat to other rooms through 6" B-vent.
Does it work in a power outage?
Yes. The wood fire needs no electricity. The two convection fans run on 110-120 VAC and stop until power returns.
How high must a mantel be, and what hearth does it need?
A combustible mantel must be at least 60" above the base and a non-combustible one at least 38", both no deeper than 12". The non-combustible hearth extension must reach 20" in front and 8" to each side of the fuel opening (41" x 20"), insulated to R 1.03.
Loading component details…
Add to cart to see your price.