Majestic Cottagewood 42" Outdoor Fireplace ODCTGWD-42-B
SKU / Model: ODCTGWD-42-B
Fireplace only$2,979.00
Black Friday Savings applied in your cart
Unlock an exclusive offer on this product.
Product overview
The Majestic Cottagewood 42 (ODCTGWD-42-B) is a wood-burning fireplace from HHT's Outdoor Lifestyles line, built for real wood fires in covered patios, porches and outdoor rooms, and also listed for indoor installations such as room dividers, walls, corners and exterior chases. It suits homeowners who want the crackle, smell and glow of a genuine wood fire as the centerpiece of an outdoor living space.
It offers a cottage-style masonry look with a broad, welcoming opening. You choose the interior: WDR2842-T or -H refractory in Natural Gray, Black Onyx or Masonry Brown, so the firebox can match stone, brick or stucco finishes. Opening: 42 in. class firebox (the chase needs a 17 in. minimum finished opening).
As a wood-burning fireplace its job is ambiance and radiant warmth close to the fire rather than heating a house; it burns seasoned firewood on the included grate behind a firescreen, and approved glass doors can be added.
It installs as a factory-built (zero-clearance) fireplace with its listed chimney: SL11 11 in. chimney: 18 ft minimum straight (18.5 ft with an offset, 24 ft with two), 90 ft maximum, 10 ft minimum in a non-combustible enclosure; listed cap. Close clearances (1-1/2 in. back and sides (1/2 in. at nailing flanges), 0 in. top standoffs to header) let it be framed into a wood or masonry chase, and it can be finished with any non-combustible facing.
If you later want the convenience of gas, the manual provides for a certified gas log lighter or decorative gas log set of up to 100,000 BTU/h with the damper locked open. The Castlewood and Cottagewood families share this approach; the Castlewood has the taller opening sized for glass doors, the Cottagewood a broader, lower cottage-style opening.
Key features
- Real wood fire: Burns solid wood only; for outdoor rooms and approved indoor locations.
- UL listed: Tested and listed to UL 127 and ULC-S610 as a factory-built fireplace (manual p.4).
- Firescreen and grate included: Firescreen, grate and protective metal hearth strips ship with the unit.
- Interior choices: WDR2842-T or -H refractory in Natural Gray, Black Onyx or Masonry Brown, required and sold separately.
- Optional glass doors: DM8042-S glass doors.
- Zero-clearance framing: 1-1/2 in. back and sides (1/2 in. at nailing flanges), 0 in. top standoffs to header.
- Listed chimney system: SL11 11 in. chimney: 18 ft minimum straight (18.5 ft with an offset, 24 ft with two), 90 ft maximum, 10 ft minimum in a non-combustible enclosure; listed cap.
- Outside air: Outside air kit on the left side: 4 in. flex up to 20 ft, or up to 40 ft with 6 in. duct (UL 181 Class 0/1).
- Drainage option: ODCTGWD-DP42 drain pan for wet locations.
- Freestanding option: Can be built into a freestanding enclosure; ODCTGWDFSK42 extended smoke shield if the vent run is under 18 ft.
- Gas log provision: Knockouts for 1/2 in. gas pipe; certified gas logs up to 100,000 BTU/h with the damper locked open.
- Sleeping rooms: May be installed in sleeping rooms; not approved for manufactured housing.
Specifications
| Model | ODCTGWD-42-B |
|---|---|
| Type | Wood-burning factory-built fireplace (UL 127), outdoor and indoor rated |
| Fuel | Seasoned firewood only (gas log provision up to 100,000 BTU/h) |
| Opening | 42 in. class firebox (the chase needs a 17 in. minimum finished opening) |
| Rough framing | 51-1/2 x 59-3/4 in., 28-1/2 in. cavity depth (p.13) |
| Clearances | 1-1/2 in. back and sides (1/2 in. at nailing flanges), 0 in. top standoffs to header |
| Chimney | SL11 11 in. chimney: 18 ft minimum straight (18.5 ft with an offset, 24 ft with two), 90 ft maximum, 10 ft minimum in a non-combustible enclosure; listed cap |
| Listing | UL 127 and ULC-S610 |
Dimensions and clearances
- Rough framing: 51-1/2 x 59-3/4 in., 28-1/2 in. cavity depth (p.13).
- Clearances to combustibles: 1-1/2 in. back and sides (1/2 in. at nailing flanges), 0 in. top standoffs to header; chimney 2 in. air space at all levels; door opening at least 24 in. from a sidewall; combustible sidewalls 24 in. from the opening.
- Mantel: combustible mantel up to 12 in. deep at least 12 in. above the opening; combustible trim may project up to 1-1/2 in. no closer than 6 in. to the top of the decorative front.
- Hearth extension (required): R-1.03 insulated, non-combustible, 20 in. in front and 12 in. each side (42 x 66 in. per Table 7.2); finished raised hearth no more than 7-5/8 in. above the floor.
What's included
- Fireplace with firescreen and grate
- Air inlet hood(s)
- Two protective hearth strips
- Attic insulation shield
- Installation and owner's manuals
Required components
- Refractory set: Traditional or Herringbone, in Natural Gray, Black Onyx or Masonry Brown
- Outside-air duct: 4-inch insulated or uninsulated flex duct
- Cottagewood 42 requires an SL1100 chimney venting system, not included with purchase.
Optional accessories
- DM8042-S glass doors
- ODCTGWD-DP42 drain pan
- ODCTGWDFSK42 extended smoke shield
- Decorative shrouds LDS33, LDS46, LDS-BV and LDSCP-M corner post kit
- Decorative caps DTO134/146, DTS134/146
Downloads
- Cottagewood 42 install manual 4108-902, Rev E 8/26
- Cottagewood 42 owner's manual 4108-903, Rev C 4/26 with warranty
Installation and safety notes
⚠ Important: this is a wood-burning fireplace. Improper installation, venting or use can cause a house fire or carbon-monoxide exposure. Majestic requires installation by a qualified installer following the installation manual and local building codes (install manual 4108-902, Rev E 8/26, p.1), and the chimney should be inspected regularly. Burn only dry, seasoned wood, never use flammable liquids to start or freshen a fire, and keep children and furniture away from hot surfaces.
Site and installation requirements
- The hearth extension can be built from HX3 or HX4 panels or field-built to the manual.
Product & safety information
- Listed to UL 127 and ULC-S610; solid wood fuel only; over-firing voids the warranty (p.4).
- Use only Hearth & Home approved parts; modifications void the listing. Installation by a qualified installer (HHT factory-trained or NFI certified recommended).
- Not approved for manufactured housing; may be installed in sleeping rooms.
Getting started
- Plan location, chase and chimney route; avoid basements (pp.5-8).
- Porch or patio: build the chase outside the weather envelope, flash it, and slope platforms 1/8-1/4 in. per foot away from the structure; use the drain pan where water can collect.
Framing & clearances
- Rough framing 51-1/2 x 59-3/4 in., 28-1/2 in. cavity depth (p.13); clearances 1-1/2 in. back and sides (1/2 in. at nailing flanges), 0 in. top standoffs to header (pp.9-16).
- The fireplace sits 1/2 in. in front of the framing face; framing across the top sits above the top standoffs; never notch the header.
- Install the two protective hearth strips on combustible floors. Outside air kit on the left side: 4 in. flex up to 20 ft, or up to 40 ft with 6 in. duct (UL 181 Class 0/1); never draw air from attics, garages or wall cavities.
Chimney & termination
- SL11 11 in. chimney: 18 ft minimum straight (18.5 ft with an offset, 24 ft with two), 90 ft maximum, 10 ft minimum in a non-combustible enclosure; listed cap (pp.17-19).
- Cap bottom at least 3 ft above the roof and 2 ft above anything within 10 ft; at most two offset/return pairs of no more than 30 degrees.
- Keep a 2 in. air space around the chimney; firestop at every floor or every 10 ft of chase.
Shrouds
- Field-built shrouds must be non-combustible sheet metal sized to the manual tables; decorative LDS shrouds are available.
Finishing
- Non-combustible facing only on the metal face; seal top and side gaps with 300 F non-combustible sealant; let mortar cure 72 hours (pp.29-36).
- Hearth extension: R-1.03 insulated, non-combustible, 20 in. in front and 12 in. each side (42 x 66 in. per Table 7.2); finished raised hearth no more than 7-5/8 in. above the floor.
- Mantel: combustible mantel up to 12 in. deep at least 12 in. above the opening.
Fireplace setup
- Install the refractory before the first fire (pp.37-39).
- Gas logs: up to 100,000 BTU/h, damper locked fully open, gas shutoff required; unvented sets only with ANSI Z211.11.2 approval, an automatic shutoff and doors fully open.
Everyday use
- First three or four fires should be moderate in size to cure paints and binders; some odor is normal (owner's manual).
- Keep the firescreen closed while burning; operate glass doors fully open or fully closed; hot glass and handles cause burns, so supervise children.
- Inspect the chimney at least annually, or every two months during heavy use, and clean creosote as needed; HHT recommends an NFPA 211 Level 2 inspection by an NFI or CSIA professional.
Building code information
- Follow local, regional, state and national building codes; chimney inspection practice per NFPA 211 (cited in the owner's manual)
- Gas log option: National Fuel Gas Code, ANSI Z223.1/NFPA 54, CAN/CGA-B149.1/.2 in Canada; decorative gas appliances to ANSI Z21.60/CSA 2.26
- Non-combustible materials are defined by ASTM E136 (published by ASTM International)
- Outside-air ducting must be UL 181 Class 0 or Class 1
Warranty
- Coverage is the Hearth & Home Technologies limited lifetime warranty, form 2108-975C (6/5/2019), printed in the Cottagewood 36/42 owner's manual 4108-903, pp.4-5.
- Product body, metal firebox and heat exchanger: limited lifetime, from the date of installation.
- Glass, refractory and glass panels that break from thermal shock: 1 year.
- Venting, optional accessories and optional glass doors: 1 year.
- Labor for warranty service work: 1 year from installation.
- Who is covered: the original owner at the installation site, and a transferee who takes ownership there within one year of purchase. It must be bought from an authorized HHT dealer and stays valid only at the original installation site.
- When coverage starts: the earliest of the invoice date; for new construction, first occupancy or six months after the dealer sale; or 24 months after HHT ships the product.
- Key exclusions: normal finish changes, wear items (paint, firebricks, grates, flame guides, glass discoloration), expansion noise, improper installation or operation, weather, non-specified fuels, non-HHT parts and modifications. Over-firing, prolonged dampness and water damage from an improper chimney void the warranty.
California Proposition 65
WARNING: This product can expose you to chemicals including soot and carbon monoxide, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Loading component details…
Add to cart to see your price.
