Product overview

The Kingsman ZCVRB72 is a 72-inch zero-clearance linear direct vent gas fireplace for homeowners who want a long, modern ribbon of flame as the focal point of a living room, great room or bedroom. It sits inside a framed chase with 0" clearance at the back, sides and top standoffs, so it fits flush-to-wall, corner, island and room-divider layouts as well as exterior walls.

The look is clean and contemporary: a wide 73-7/8" x 20" viewing area with flames dancing across decorative bronze ember glass, which ships with the fireplace. You can change the mood with multi-coloured cannonballs, alternative glass colours or Kingsman's driftwood, birch and oak linear log sets, add a porcelain reflective liner to multiply the flame, and finish the opening with a black or stainless surround or a tile-lip kit for a frameless finish.

Heat output is up to 50,000 BTU/h on natural gas or propane, with a Hi/Lo valve that lets you turn the flame and heat down for milder days. Kingsman lists a fireplace efficiency (FE) of 53.14% MV / 53.64% IPI. It is certified as a vented room heater and approved for bedrooms, bed-sitting rooms and manufactured homes, so it can serve as zone heat in the room you use most.

Choose millivolt ignition, which needs no house power and keeps working in a power failure, or IPI electronic ignition with battery backup. IPI models can be paired with Proflame remotes (on/off, thermostatic, modulating and fan control), and the Proflame 2 remote on IPI PF2 models adds flame-height modulation and multi-colour LED accent lighting control. A heat-activated variable-speed fan kit and wall thermostats are optional.

Venting is 5"/8" (Kingsman Z-Flex 5"/8" flex or listed 5"/8" rigid direct vent), routed horizontally through the wall or vertically through the roof, with an optional PVH58 power vent for long or difficult runs. The chase can be left unvented, or vented with a front grill, side grills or an open top to create Kingsman's Cool Touch Wall: a vented chase runs about 40% cooler and drops the minimum mantel height from 40-1/2" to 28", which also makes a TV above the fireplace practical.

The 72 is the largest fireplace in the Kingsman range, with nearly six feet of flame and the highest output of the ZCVRB family; it is the only ZCVRB with ceramic glass as standard.

Key features

  • Linear direct vent design: sealed combustion draws outside air and exhausts outdoors through 5"/8" venting.
  • Zero-clearance installation: 0" to combustibles at the back, sides, floor and top standoffs; 36" in front (manual pp.18, 26).
  • Hi/Lo millivolt valve: standard on millivolt models; operates during power failures with no electricity needed.
  • IPI electronic ignition (optional models): intermittent pilot ignition with battery backup; a cold-climate (standing pilot) setting is available.
  • Decorative bronze ember glass: included and required: the fireplace must not run without the glass embers on the burner and media tray.
  • Ceramic glass front: 73-7/8" x 20" viewing area.
  • Safety screen barrier: included over the glass to reduce the risk of burns from the hot glass.
  • Heat output: 50,000 BTU/h maximum input on natural gas and propane; Hi/Lo turndown.
  • Efficiency: FE 53.14% MV / 53.64% IPI (Kingsman specification).
  • Approvals: mobile/manufactured home, bedroom and bed-sitting room approved.
  • Vented chase option (Cool Touch Wall): vent the chase with grills or an open top for cooler walls and a lower 28" mantel; minimum free area 285 sq in.
  • Enclosure grills (optional): VL72EG front grill (78-5/8" x 3-5/8" opening, 285 sq in); VL72EGS side grills, pair (two 15-1/4" x 9" openings, 285 sq in).
  • Surround (optional): ZCVRB72S1BL black or ZCVRB72S1SS stainless steel, covers 76-3/4" W x 23" H.
  • Fan kit (optional): Z46FK heat-activated fan with variable speed control.
  • Universal light kit (optional): ULK64 four-lamp universal light kit (12 VAC halogen) for accent lighting.
  • Wall thermostat (optional): standard on/off or programmable 5-day/2-day models (Z2MT, Z80PT).
  • Remote controls (optional): on/off, thermostatic, thermostatic modulating, and thermostatic modulating with fan control.
  • Proflame 2 remote (IPI PF2 models): flame-height modulation and multi-colour LED accent lighting control.
  • Wall mount battery holder (optional): WMBH puts the IPI backup batteries in an accessible wall box within 16 ft of the valve.
  • Liner option: ZCVRB72PL porcelain reflective liner.
  • Media options: RBCB1 multi-coloured cannonballs, alternative glass colours and linear log sets.
  • Power vent compatible: PVH58 or PVH58FM power vent for extended horizontal runs.
  • Field conversion: NG/LP conversion kits available (72ZCVRB-CKLP / -CKNG (millivolt); 72ZCVRB-CKLPI / -CKNGI / -CKLP2 / -CKNG2 (IPI)).
  • Certification: CSA/ANSI Z21.88-19 / CSA 2.33-19 vented gas fireplace heater; CSA 2.17-2017 (high altitude).

Specifications

Models ZCVRB72N / ZCVRB72LP (millivolt); ZCVRB72NE / ZCVRB72LPE (IPI)
Type Zero-clearance linear direct vent gas fireplace, top vent
Unit dimensions 78-3/4" W x 40-5/16" H x 19-3/8" D (Kingsman specification)
Framing dimensions Rough-opening size not published by the manufacturer. Framing goes directly to the fold-out standoffs (0" at the back, sides and top) and must not extend past them; minimum ceiling/enclosure height 79" from the bottom of the fireplace; no hearth required (manual pp.10, 17–18)
Viewing area 73-7/8" W x 20" H
Clearances to combustibles Front 36"; back, sides, top standoffs and floor 0"; ceiling at least 79" above the bottom of the fireplace; combustible mantel at least 40-1/2" above the bottom of the unit (unvented chase) or 28" (vented chase); vent pipe: top of a 90° bend 4", top of horizontal pipe 2", sides and bottom of horizontal pipe 1", vertical pipe 1" (pp.14, 17–18, 26)
Input, natural gas (max / min) 50,000 / 34,000 BTU/h
Input, propane (max / min) 50,000 / 39,000 BTU/h
Fireplace efficiency (FE) 53.14% MV / 53.64% IPI
Glass Ceramic, with safety screen barrier
Venting 5"/8" (Kingsman Z-Flex 5"/8" flex or listed 5"/8" rigid direct vent)
Ignition Hi/Lo millivolt or IPI with battery backup
Gas inlet 3/8" NPT
Electrical 120 VAC grounded receptacle for fan / IPI adapter; millivolt runs without power
Media included Decorative bronze ember glass
Maximum media load 15 lb (10 lb with logs or stones)
Approvals Bedroom, bed-sitting room, manufactured/mobile home
Certification CSA/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017

Dimensions and clearances

  • Horizontal-vent framing height: 71" minimum, plus 1/4" of rise per foot (p.17).
  • Non-combustible facing (unvented chase): at least 32-1/2" x 79-1/8"; recommended 35-3/4" x 80-5/8" (p.19).
  • Vented chase: minimum enclosure height 79"; minimum free opening 285 sq in; grills within 3/4" of the sealed enclosure top; open top 2-3/8" minimum on three sides (pp.13, 21–24).
  • TV above the fireplace: recommended only with a vented chase (or the recessed option); keep the TV at least 1" from the vent grill or opening (pp.14, 25).
  • Appliance weight: not listed in the manual text.

What's included

  • Fireplace with linear burner, set up for the selected fuel and ignition
  • Decorative bronze ember glass
  • Ceramic glass front
  • Safety screen barrier
  • Nailing tabs (two per side) and standoffs
  • Removable lower face panel

Required components

  • 5"/8" direct vent pipe and a matching horizontal or vertical termination (Kingsman Z-Flex or a listed rigid system)
  • Non-combustible facing over the face of the fireplace in an unvented chase (minimum 32-1/2" x 79-1/8")
  • For a vented chase: VL72EG front grill, VL72EGS side grills, pair, a custom grill, or an open top meeting the minimum free area
  • Gas supply with a manual shutoff valve (3/8" NPT inlet; 1/2" rigid pipe or an approved flex connector such as FP15GC)
  • 120 VAC grounded receptacle for the fan kit or IPI models (split receptacle installed by an electrician)
  • Four AA batteries for IPI battery backup and remote receiver

Optional accessories

  • ZCVRB72S1BL black surround trim kit
  • ZCVRB72S1SS stainless steel surround trim kit
  • ZCVRB72PL porcelain reflective panel liner
  • RBCB1 multi-coloured cannonballs
  • Z46FK fan kit with variable speed control
  • ULK64 universal light kit
  • Z2MT digital or Z80PT programmable wall thermostat
  • GTRC / GTMRCN / GTMRCP / GTFRCN / GTFRCP millivolt remotes
  • EGTRC / EGTMRCN / EGTMRCP / EGTFRCN / EGTFRCP IPI Proflame remotes
  • WMBH wall mount battery holder (IPI)
  • PVH58 / PVH58FM power vent with PVC58MV or PVC58IPI control module
  • VL72EG front grill and VL72EGS side grills, pair (vented chase)

Downloads

Installation and safety notes

⚠ Important: this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (ZCVRB72 installation and operating manual (72ZCV-MAN19), cover and pp.5–7). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.

Product and safety information (pp.4–9)

  • Certified to CSA/ANSI Z21.88-19 and CSA 2.33-19 as a vented gas fireplace heater (cover). It is not meant as a primary heat source (p.6).
  • Approved for bedrooms and bed-sitting rooms (in Canada with a listed millivolt thermostat) and for manufactured/mobile homes where local codes allow; manufactured-home installs need an 8 AWG copper ground to the chassis (pp.7–8).
  • Gas orifices are sized for 0–4,500 ft elevation; installations above that need the orifice sizing confirmed (p.43).
  • Indoor appliance. A covered outdoor location is allowed only for basic millivolt models without fan or lights, with a roof overhang and no operation below 32°F (p.9).
  • In Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).

Framing, chase and clearances (pp.10–28)

  • Minimum ceiling/enclosure height 79" from the bottom of the fireplace; front clearance 36"; 0" at the back, sides, floor and top standoffs (pp.17–18, 26).
  • Fold out and screw the standoffs before installing; framing must not extend past them. No hearth is required (p.10).
  • Run horizontal venting straight out the back wall above the flue with a wall thimble; no horizontal runs or offsets inside the enclosure (pp.11, 16).
  • Unvented chase: non-combustible facing at least 32-1/2" x 79-1/8"; mantel 40-1/2" above the bottom of the unit (pp.14, 19–20).
  • Vented chase: 285 sq in minimum free opening, minimum enclosure height 79"; mantel 28"; combustible facing such as drywall is allowed in a vented chase (pp.14–15, 21–27).
  • Use 1/2" minimum concrete board and self-tapping screws no longer than 2". Granite and tile cracking or discoloration is not covered by the warranty (p.15).
  • A combustible hearth may sit below the appliance opening (pp.20, 27).

Components, trim and liners (pp.29–42)

  • Surround ZCVRB72S1BL / ZCVRB72S1SS covers 76-3/4" W x 23" H; frames are 3/4" thick, with gap options of 5/8", 7/8" or 1-1/8", and non-combustible facing up to 1" thick may run under it.
  • The Z46FK fan installs with its speed control outside the firebox; a split receptacle provides constant power inside the unit and must be installed by a qualified electrician (pp.33–34).
  • Never operate with the glass door removed, cracked or broken; replacement glass must be the Kingsman part (pp.5–6, 35).

Gas (pp.43–51)

  • Natural gas supply 5.5" min / 7" normal / 9" max w.c.; manifold 3.5" high / 1.6" low w.c. (p.43).
  • Propane supply 11" min / 11" normal / 12" max w.c.; manifold 10" high / 6.3" low w.c. (p.43).
  • 3/8" NPT inlet; minimum 3/8" iron pipe (natural gas) with at least 4.5" w.c. at the meter; 1/2" rigid pipe or an approved flex connector such as FP15GC. Disconnect the appliance for pressure tests above 1/2 psig (p.43).
  • Field conversion between natural gas and propane uses the Kingsman kits 72ZCVRB-CKLP / -CKNG (millivolt); 72ZCVRB-CKLPI / -CKNGI / -CKLP2 / -CKNG2 (IPI), installed by a qualified agency (pp.48–50).
  • Have the burner, pilot and venting inspected every year by a qualified technician; check the flame monthly.

Electrical

  • Millivolt models need no electricity to run. Do not wire 120 V to millivolt switches or thermostats; wall-switch wire runs are limited by gauge (e.g. 18 AWG up to 40 ft).
  • The fan kit, light kit and IPI adapter need a grounded three-prong 120 VAC receptacle; do not remove the ground prong (pp.6, 33–34).
  • IPI battery backup runs the fire during a power outage on four AA batteries; fans and lights do not run on battery. Replace them before each heating season.

Media, logs and lighting (pp.52–63)

  • Spread the decorative glass embers on the burner and media tray before use (maximum 15 lb (10 lb with logs or stones)); never cover the pilot, and the pilot must be visible when lighting.
  • Approved options include RBCB1 cannonballs, glass colours and Kingsman linear log sets; the ULK64 light kit runs on a 12 VAC transformer.

IPI and Proflame controls (pp.64–78)

  • IPI models can run in intermittent pilot mode or a cold-climate standing-pilot mode, which keeps the firebox and vent warm in very cold weather.
  • The Proflame 2 system has a 24-hour safety shut-off if the remote is not heard from; the WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).

Venting (pp.79–87)

  • Vent: 5"/8" (Kingsman Z-Flex 5"/8" flex or listed 5"/8" rigid direct vent). Only components listed for this appliance may be used, and systems must not be mixed.
  • Minimum vertical 71"; maximum vertical 43 ft; maximum horizontal 20 ft (with an 8 ft rise); 1/4" of rise per 12" of horizontal run (p.82).
  • Elbows: up to four 45° bends (18" each) plus two more 90° bends (36" each) (p.82).
  • Restrictor: set the flue restrictor by vent length: wide open at 15–20 ft, #1 at 25 ft, #2 at 30 ft, #3 at 35 ft, #4 at 40 ft (p.85).
  • Key terminal clearances: 12" above grade, decks and balconies; 9" from openable windows and doors (10,000–50,000 BTU/h class); 18" from a ventilated soffit; 24" from an adjacent wall; 7 ft above public walkways; 3 ft from a gas meter or regulator; terminate at least 18" above the roof. Keep combustibles 24" from the hot termination cap.
  • Power venting (PVH58 / PVH58FM) is approved for long horizontal runs; downward runs are allowed only on IPI models.

First fire and everyday use (p.5)

  • Break-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out during curing.
  • After turning it off, wait at least 60 seconds before relighting.
  • The glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).
  • Never burn wood or paper, and do not use the fireplace if any part has been under water (p.6).
  • Install carbon-monoxide detectors on every level and near bedrooms (p.7).

Building code information

Warranty

  • Coverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (ZCVRB72 installation and operating manual (72ZCV-MAN19), p.92).
  • Basic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.
  • Limited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.
  • Not covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.
  • Who is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.
  • Proof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.
  • How to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.
  • Key exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.

California Proposition 65

WARNING: This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to www.P65Warnings.ca.gov.

Flames and flame colors on the website may appear differently in real life.

Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.

Frequently asked questions — ZCVRB72

What framing does the ZCVRB72 need?

It is a zero-clearance fireplace: framing goes right to the fold-out standoffs with 0" clearance at the back, sides and top, and must not extend past them. The enclosure needs at least 79" of height from the bottom of the fireplace, and no hearth is required. The unit measures 78-3/4" W × 40-5/16" H × 19-3/8" D.

What venting does it use, and how far can it run?

It vents off the top with 5"/8" direct vent pipe (Kingsman Z-Flex flex or listed 5"/8" rigid). Vertical runs go from 71" minimum to 43 ft maximum, and horizontal runs up to 20 ft with an 8 ft rise, sloped up 1/4" per foot.

Can the ZCVRB72 run on propane?

Yes. It comes in natural gas and propane versions at up to 50,000 BTU/h on either fuel, and field conversion kits are available: 72ZCVRB-CKLP for millivolt models and 72ZCVRB-CKLPI or 72ZCVRB-CKLP2 for IPI models.

Does it work in a power outage?

Yes. Millivolt models need no electricity at all. IPI models keep the fire running on four AA backup batteries; the fan and lights do not run on battery.

Can a TV go above it, and how high must the mantel be?

A TV above is recommended only with a vented chase (or the recessed option), kept at least 1" from the vent grill or opening. A combustible mantel must be at least 40-1/2" above the bottom of the unit with an unvented chase, or 28" with a vented chase.

What's the warranty?

Defective components are covered for parts and labour for the first year after installation, except accent light bulbs, gasketing, glass fronts and paint. The heat exchanger, combustion chamber and burner carry a limited lifetime warranty for as long as the original owner owns the fireplace; after the first year the defective part is exchanged, and labour and freight are not covered.