Kingsman ZCV42 Clean View Direct Vent Gas Fireplace ZCV42
SKU / Model: ZCV42N
Fireplace only$3,314.59
Early Black Friday Savings applied in your cart
Unlock an exclusive offer on this product.
Product overview
The Kingsman ZCV42 is a 42-inch Designer Clean View zero-clearance direct vent gas fireplace: a traditional fire framed by a clean, louver-free face. It is the largest member of the Clean View family, sized for living rooms, family rooms and bedrooms, and installs flush on a wall, across a corner or in a bump-out chase.
The 37-1/8" W x 31-3/4" H tempered glass shows the LOGF3 log set or the ZCV42GT glass tray with bronze ember glass, with RBCB1 cannonballs as an option on the tray. ZCV42RLT traditional brick, ZCV42RLH herringbone brick, ZCV42RLS stacked brick or ZCV42PL porcelain reflective liners set the style, and a hearth-mount or picture-frame surround or the ZCVTLK tile lip kit finishes the face. Input is 25,000 BTU/h on natural gas or propane with Hi/Lo adjustment, at a fireplace efficiency of 52.86% MV / 54.95% IPI.
A millivolt valve needs no house power and IPI ignition has battery backup, so both keep the fire going in a power outage. It vents 4"/7" through the wall or roof, through a co-linear kit, or with a PVH58 power vent. Proflame remotes, wall thermostats and the Z46FK fan are available. The ZCV42H is the same fireplace with ceramic glass.
Key features
- Designer Clean View face: no louvers; a clean frame around the glass.
- Zero-clearance direct vent: 0" at the back, sides, floor and top standoffs; 36" in front.
- Hi/Lo millivolt or IPI valve: operates during a power failure, with Hi/Lo heat and flame adjustment.
- Safety screen barrier: included.
- Tempered glass: 37-1/8" W x 31-3/4" H viewing area.
- Heat output: 25,000 / 16,500 BTU/h natural gas; 25,000 / 19,500 BTU/h propane (max/min).
- Efficiency: FE 52.86% MV / 54.95% IPI.
- Flame display: LOGF3 log set, ZCV42GT glass tray with bronze ember glass, RBCB1 cannonballs (glass tray required).
- Fan kit (optional): Z46FK heat-activated with variable speed control.
- Surrounds (optional): ZCV42S1BL hearth-mount 4" wide (covers 44-11/16" W x 38-1/8" H); ZCV42S1PFBL picture frame 4" wide (covers 44-11/16" W x 40-1/8" H); ZCV42S2PFBL picture frame 1-5/8" wide (covers 40-3/16" W x 35-5/8" H).
- Tile lip kit (optional): ZCVTLK for a frameless finish.
- Liners (optional): ZCV42RLT traditional brick, ZCV42RLH herringbone brick, ZCV42RLS stacked brick or ZCV42PL porcelain reflective.
- Accent lighting (optional): ULK2 accent light kit (with the glass tray).
- Thermostat (optional): Z2MT wall-mount or Z80PT programmable.
- Remote control (optional): thermostat on/off, thermostatic modulating, thermostatic modulating with fan control.
- Proflame 2 remote (IPI PF2 models): flame-height modulation and multi-colour LED accent lighting control.
- Vented chase option: V39EG front grill (36-1/2" x 3-5/8" opening, within 3/4" of the enclosure top) or V39EGS side grills (two 12-1/2" x 6-1/8" openings, both sides required); open top needs 2" on three sides; minimum enclosure 72".
- Wall mount battery holder (optional): WMBH for the IPI backup batteries.
- Power vent compatible: PVH58 / PVH58FM.
- Field conversion: NG/LP kits 42ZCV-CKLP, -CKNG, -CKLPI, -CKNGI, -CKLP2 and -CKNG2.
- Approvals and certification: CSA/ANSI Z21.88-19 / CSA 2.33-19 heater, CSA 2.17-2017; manufactured/mobile home approved.
Specifications
| Models | ZCV42N / ZCV42LP (millivolt); ZCV42NE / ZCV42LPE (IPI) |
|---|---|
| Type | Zero-clearance Clean View direct vent gas fireplace, top vent |
| Unit dimensions | 42-7/16" W x 40-7/8" H x 18-7/16" D (Kingsman specification) |
| Framing dimensions | Framing depth 18-1/2" for framing flush with the face of the unit, 18" for 1/2" drywall flush with the face (pp.33, 38); framed opening width and height are not published by the manufacturer as labeled values; minimum ceiling height from the bottom of the fireplace 59-1/2" natural gas / 71-1/2" propane (non-vented chase, p.36), minimum enclosure 72" (vented chase, pp.38–44); recommended non-combustible facing area 42-5/8" x 44" (p.37) |
| Viewing area | 37-1/8" W x 31-3/4" H |
| Clearances to combustibles | Front 36"; back, sides, floor and top 0"; top of a 90° bend 3-1/2"; top of horizontal pipe 1-1/2", sides and bottom 1"; vertical pipe 1" (pp.36, 44); facing: non-vented chase, any face material non-combustible (p.37); vented chase, combustible drywall allowed up to the opening (p.45); mantels: combustible mantel minimum heights not published by the manufacturer in text form; a combustible hearth may sit below the opening |
| Input, natural gas (max / min) | 25,000 / 16,500 BTU/h |
| Input, propane (max / min) | 25,000 / 19,500 BTU/h |
| Fireplace efficiency (FE) | 52.86% MV / 54.95% IPI |
| Glass | Tempered, with safety screen barrier |
| Venting | 4"/7" flex, 4" x 6-5/8" rigid, or PVH58 power vent |
| Ignition | Hi/Lo millivolt or IPI with battery backup |
| Gas inlet | 3/8" NPT |
| Certification | CSA/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017 |
Chase venting and floor protection
- Vented chase: V39EG front grill (36-1/2" x 3-5/8" opening, within 3/4" of the enclosure top) or V39EGS side grills (two 12-1/2" x 6-1/8" openings, both sides required); open top needs 2" on three sides; minimum enclosure 72".
- Floor: no hearth is required; over carpet or another combustible floor covering use a full-width metal or wood panel; with vinyl flooring use a 12" hearth or raise the unit 24".
Included components
- Fireplace with burner, set up for the selected fuel and ignition
- Tempered glass front
- Safety screen barrier
Required components
- A flame display (one required): LOGF3 Fibre Split Oak log set, or the ZCV42GT glass tray with 20 lb (4 bags) of Z5GC bronze glass media
- 4"/7" direct vent pipe and termination (Kingsman Z-Flex or listed 4" x 6-5/8" rigid with the ZDVDFA adapter), or a PVH58 power vent
- Non-combustible facing in a non-vented chase
- For a vented chase: V39EG / V39EGS grills or an open top
- Gas supply with manual shutoff (3/8" NPT)
- 120 VAC grounded receptacle for the fan or IPI models
- Four AA batteries for IPI battery backup
Optional accessories
- ZCV42S1BL hearth-mount 4" wide surround
- ZCV42S1PFBL picture frame 4" wide surround
- ZCV42S2PFBL picture frame 1-5/8" wide surround
- ZCVTLK tile lip kit
- ZCV42RLT traditional brick
- ZCV42RLH herringbone brick
- ZCV42RLS stacked brick
- ZCV42PL porcelain reflective
- RBCB1 multi-coloured cannonballs
- Z46FK fan kit
- ULK2 accent light kit
- Z2MT wall thermostat
- Z80PT programmable wall thermostat
- GTRC millivolt remote
- GTMRCN millivolt remote
- GTMRCP millivolt remote
- GTFRCN millivolt remote
- GTFRCP millivolt remote
- EGTRC IPI remote
- EGTMRCN IPI remote
- EGTMRCP IPI remote
- EGTFRCN IPI remote
- EGTFRCP IPI remote
- WMBH wall mount battery holder
- PVH58 power vent
- PVH58FM flush-mount power vent
- V39EG front enclosure grill
- V39EGS side enclosure grills (both sides required)
Downloads
- ZCV39/ZCV42 installation and operating manual (39ZCV-MAN19), includes the warranty
- ZCV34/39/42 brochure and specifications (Dec 2025)
- Kingsman 2025 product guide
Installation and safety notes
⚠ Important: this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (ZCV39/ZCV42 installation and operating manual (39ZCV-MAN19), cover and safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.
Product and safety information (pp.5–9)
- Certified to CSA/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).
- Approved for manufactured/mobile homes where local codes allow (mobile home section).
- In Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.6).
Framing, chase and clearances (pp.10–46)
- Front clearance 36"; 0" at the back, sides, floor and top; minimum ceiling 59-1/2" (natural gas) / 71-1/2" (propane) from the bottom of the fireplace (non-vented); 72" minimum enclosure with a vented chase.
- No hearth is required.
- Facing: non-vented chase: any face material must be non-combustible, recommended area 42-5/8" x 44" (p.37); vented chase: combustible drywall allowed up to the opening (p.45).
- Mantels: combustible mantel minimum heights are not published by the manufacturer in text form; a combustible hearth may sit below the opening.
- Vented chase: V39EG front grill (36-1/2" x 3-5/8" opening, within 3/4" of the enclosure top) or V39EGS side grills (two 12-1/2" x 6-1/8" openings, both sides required); open top needs 2" on three sides; minimum enclosure 72".
Finishing: surrounds, tile lip and doors (pp.47–58)
- Surrounds: ZCV42S1BL hearth-mount 4" wide (covers 44-11/16" W x 38-1/8" H); ZCV42S1PFBL picture frame 4" wide (covers 44-11/16" W x 40-1/8" H); ZCV42S2PFBL picture frame 1-5/8" wide (covers 40-3/16" W x 35-5/8" H).
- Tile lip kit ZCVTLK for tile or stone finished up to the opening.
- Never operate with the glass removed, cracked or broken; replacement glass must be tempered, at least 5 mm thick.
Media, logs and accessories (pp.59–79)
- The flame display is chosen separately: the LOGF3 Fibre Split Oak log set, or the ZCV42GT glass tray with bronze ember glass (pp.66–72).
- Keep the pilot visible and uncovered; use only Kingsman-listed media.
- The Z46FK fan's speed control mounts outside the unit; a split receptacle supplies constant power and must be installed by an electrician.
Gas (pp.80–90)
- Natural gas supply 5.5" min / 7" normal / 9" max w.c.; manifold 3.5" high / 1.6" low w.c. (p.82).
- Propane supply 11" min / 11" normal / 12" max w.c.; manifold 10" high / 6.3" low w.c. (p.82).
- 3/8" NPT inlet; minimum 3/8" iron pipe for natural gas with at least 4.5" w.c. at the meter; 1/2" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1/2 psig (p.82).
- Orifices are sized for 0–4,500 ft elevation (p.82). Field conversion between natural gas and propane uses Kingsman kits 42ZCV-CKLP, -CKNG, -CKLPI, -CKNGI, -CKLP2 and -CKNG2, installed by a qualified agency (pp.86–89).
- Have the burner, pilot and venting inspected every year by a qualified technician.
Controls and electrical (pp.91–104)
- Millivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.91–104).
- IPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.
- Proflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).
- Do not wire 120 V to millivolt switches or thermostats; switch-wire length is limited by gauge.
Venting (pp.105–116)
- Vent: 4"/7" Kingsman flex, 4" x 6-5/8" rigid (DuraVent with adapter) or PVH58 power vent.
- Minimum vertical 52-1/2" (natural gas) / 64-1/2" (propane), floor to vent centre; maximum vertical 43 ft; maximum horizontal 20 ft (with 7–20 ft of vertical rise; 12 ft at 6 ft vertical); 1/4" rise per 12" of horizontal run.
- Up to two 45° bends in the horizontal run (18" off the run each) plus two more 90° bends (36" each); remove the flue restrictor for runs under 15 ft.
- Power venting: equivalent length up to 125 ft; downward runs are allowed only on IPI models without the cold-climate switch.
- Keep the termination 24" from obstructions and flammables, terminate at least 18" above the roof, and never recess it into the wall.
First fire and everyday use
- Break-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).
- After turning it off, wait at least 60 seconds before relighting (p.5).
- The glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).
- Never burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).
- Install carbon-monoxide detectors on every level and near bedrooms (p.7).
Building code information
- Install to local codes; where none exist, follow the current National Fuel Gas Code, ANSI Z223.1/NFPA 54, or in Canada CSA B149.1 (p.6).
- Electrical work: National Electrical Code, ANSI/NFPA 70, or in Canada CSA C22.1 Canadian Electrical Code (p.6).
- Manufactured homes: Manufactured Home Construction and Safety Standard, 24 CFR Part 3280 and ANSI/NFPA 501A; in Canada CAN/CSA Z240 MH (p.9).
- Carbon-monoxide detectors (Massachusetts and recommended practice): NFPA 720 and ANSI/UL 2034 (p.6).
- Massachusetts installations follow the Massachusetts fuel gas code (248 CMR) and 527 CMR (p.6).
Warranty
- Coverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (ZCV39/ZCV42 installation and operating manual (39ZCV-MAN19), p.122).
- Basic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.
- Limited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.
- Not covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.
- Who is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.
- Proof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.
- How to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.
- Key exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.
California Proposition 65
WARNING: This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Frequently asked questions — ZCV42
What framing does the ZCV42 need?
It is a zero-clearance fireplace: 0" at the back, sides, floor and top, with 36" clear in front. The unit measures 42-7/16" W x 40-7/8" H x 18-7/16" D. Framing depth is 18-1/2" for framing flush with the face of the unit, or 18" with 1/2" drywall flush with the face. In a non-vented chase the ceiling must be at least 59-1/2" (natural gas) or 71-1/2" (propane) above the bottom of the fireplace; a vented chase must be at least 72" tall. No hearth is required.
What venting does it use, and how far can it run?
It vents off the top with 4"/7" Kingsman flex or 4" x 6-5/8" rigid direct vent pipe, a co-linear kit (12 ft minimum, 43 ft maximum), or a PVH58 power vent (up to 125 ft plus six 90° elbows). Minimum vertical is 52-1/2" (natural gas) or 64-1/2" (propane) from the bottom of the fireplace, and the maximum is 43 ft. Horizontal runs go up to 20 ft with 7 to 20 ft of vertical rise, 12 ft at 6 ft of vertical, 15 ft at 25 ft and 10 ft at 30 ft, with at least 1/4" of rise per foot of horizontal run. Propane installations need an extra 1 ft of vertical rise before going horizontal.
Can the ZCV42 run on propane?
Yes. It is offered here in natural gas (ZCV42N millivolt, ZCV42NE IPI) and propane (ZCV42LP millivolt, ZCV42LPE IPI) versions, rated 25,000 / 16,500 BTU/h on natural gas and 25,000 / 19,500 BTU/h on propane (max/min). Field conversion uses Kingsman kits 42ZCV-CKLP, -CKNG, -CKLPI, -CKNGI, -CKLP2 and -CKNG2.
Does it work in a power outage?
Yes. Millivolt models need no electricity at all. IPI models run on a 120 VAC adapter with a four-AA battery backup that keeps the fire working in an outage; the fan and lights do not run on battery.
Is a log set included?
No. One flame display is required and sold separately: the LOGF3 five-piece Fibre Split Oak log set, or the ZCV42GT glass tray with 20 lb (four 5 lb bags) of Z5GC bronze glass media. RBCB1 cannonballs can be added on the glass tray.
Can it be installed in a bedroom?
Yes. It is certified for installation in a bedroom or bed-sitting room; in Canada it must be installed with a listed millivolt thermostat. It is also approved for manufactured/mobile homes where local codes allow.
Loading component details…
Add to cart to see your price.

