Kingsman ZCV3622 36" Direct Vent Gas Fireplace ZCV3622

SKU / Model: ZCV3622N

Free Fast Shipping
In-stock items are processed in 1–2 business days.

$2,224.22

Early Black Friday Savings applied in your cart

YOUR SPECIAL OFFER IS AVAILABLE

This product qualifies for an exclusive special offer.

Complete your selections and add this product to your cart to unlock the eligible offer.

Offer eligibility and final promotional pricing are confirmed in the cart. Accessories qualify separately. Offers may change.

Product overview

The Kingsman ZCV3622 is a 36-inch zero-clearance direct vent gas fireplace with a traditional log fire, sized for bedrooms, dens, basements and smaller living rooms where a full-size fireplace would overwhelm the space. It is approved for bedrooms, bed-sitting rooms and manufactured homes.

The 29-3/4" W x 18-5/8" H tempered glass front shows a realistic burn across the LOGC51 five-piece oak log set on Kingsman's proprietary burner, framed by your choice of porcelain reflective or metal brick liner.

Input is 18,000 BTU/h on natural gas and 18,000 BTU/h on propane with Hi/Lo adjustment; Kingsman lists a fireplace efficiency (FE) of 60.54% MV / 63.46% IPI (NG); 62.09% / 65.09% (LP), high for a compact unit, which makes it useful zone heat.

A Hi/Lo millivolt valve (no power needed) or IPI electronic ignition with battery backup both run through a power failure. Wall thermostats (standard or 5-day/2-day programmable), on/off and thermostatic remotes, and a heat-activated Z36FK fan kit are available.

Venting is 4"/7" direct vent (Kingsman Z-Flex or 4" x 6-5/8" rigid pipe with the ZDVDFA adapter), a 3"/3" co-linear liner into an existing chimney, or a PVH58 power vent, so it adapts to most homes.

The ZCV3622 is the traditional sister of the ZCVRB3622: same compact body, with an oak log fire instead of glass media.

Key features

  • Compact zero-clearance direct vent: 0" to the back, sides, floor and top standoffs; 36" in front.
  • Hi/Lo millivolt or IPI valve: works during power failures.
  • Proprietary burner: realistic burn.
  • Approvals: mobile home, bedroom and bed-sitting room approved.
  • Safety screen barrier: included.
  • Tempered glass: 29-3/4" W x 18-5/8" H viewing area.
  • Heat output: 18,000 / 13,000 BTU/h natural gas; 18,000 / 15,000 BTU/h propane (max/min).
  • Efficiency: FE 60.54% MV / 63.46% IPI (NG); 62.09% / 65.09% (LP).
  • LOGC51 oak log set: the flame display for this model (sold separately).
  • Surrounds (optional): ZCV36S1BL hearth-mount black surround (covers 39" W x 34-1/16" H framing); ZCV36SWFBL flat black surround (covers 40-7/8" W x 37-1/4" H).
  • Fan kit (optional): Z36FK heat activated with variable speed control.
  • Wall thermostat (optional): standard on/off or programmable 5-day/2-day.
  • Remote control (optional): on/off, thermostat on/off, thermostatic modulating.
  • Liners (optional): ZCV3622PRL porcelain reflective liner; ZCV3622ML metal brick liner.
  • Wall mount battery holder (optional): WMBH for IPI backup batteries.
  • Venting flexibility: 4"/7" flex or rigid, 3"/3" co-linear, or PVH58 power vent.
  • Certification: CSA/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.

Specifications

Models ZCV3622N / ZCV3622LP (millivolt); ZCV3622NE / ZCV3622LPE (IPI)
Type Zero-clearance direct vent gas fireplace, top vent
Input, natural gas (max / min) 18,000 / 13,000 BTU/h
Input, propane (max / min) 18,000 / 15,000 BTU/h
Fireplace efficiency (FE) 60.54% MV / 63.46% IPI (NG); 62.09% / 65.09% (LP)
Viewing area 29-3/4" W x 18-5/8" H
Glass Tempered 5 mm, with safety screen barrier
Unit size 36" W x 37-1/8" H x 17-7/16" D (Kingsman specification)
Venting 4"/7" flex or 4" x 6-5/8" rigid; 3"/3" co-linear; PVH58 power vent
Ignition Hi/Lo millivolt or IPI with battery backup
Gas inlet 3/8" NPT
Certification CSA/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017

Dimensions and clearances

  • Unit: 36" W x 37-1/8" H x 17-7/16" D; viewing area 29-3/4" W x 18-5/8" H (Kingsman spec table).
  • Clearances: front 36"; back, sides, floor and top standoffs 0"; ceiling at least 60" above the bottom of the fireplace with the flue restrictor installed (46-1/2" with it removed); top of a 90° bend 2-1/2" (10" with the restrictor removed); horizontal pipe 1-1/2" top, 1" sides and bottom; vertical pipe 1" (manual pp.15–16).
  • Mantel: a combustible mantel must meet the manual's mantel diagram (p.18); a non-combustible mantel may extend to the tile lip.
  • Facing: combustibles up to the fireplace edge only; the face covering must be non-combustible; a combustible hearth may be no more than 3" high (p.17).
  • Floor: no hearth is required; vinyl flooring needs a 12" hearth or a 24" raise; carpet needs a metal or wood panel (pp.12–15).
  • Appliance weight: not listed in the manual text.

What's included

  • Fireplace with burner, set up for the selected fuel and ignition
  • Tempered glass front
  • Safety screen barrier

Required components

  • LOGC51 oak log set (the flame display Kingsman lists for this model)
  • 4"/7" direct vent pipe and termination (or a 3"/3" co-linear kit or PVH58 power vent)
  • Non-combustible face covering
  • Gas supply with manual shutoff (3/8" NPT)
  • 120 VAC grounded receptacle for the fan or IPI models
  • Four AA batteries for IPI battery backup

Optional accessories

  • ZCV36S1BL hearth-mount black surround (covers 39" W x 34-1/16" H framing)
  • ZCV36SWFBL flat black surround (covers 40-7/8" W x 37-1/4" H)
  • ZCV3622PRL porcelain reflective liner
  • ZCV3622ML metal brick liner
  • Z36FK fan kit
  • Z2MT / Z80PT wall thermostats
  • Proflame remotes (GT / EGT series)
  • WMBH wall mount battery holder
  • PVH58 / PVH58FM power vent
  • ZDVDFA DuraVent/ICC adapter for rigid pipe

Downloads

Installation and safety notes

⚠ Important: this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (ZCV3622/ZCVRB3622 installation and operating manual (36ZCV-MAN19), safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.

Product and safety information (pp.2–5)

  • Certified to CSA/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).
  • Approved for bedrooms, bed-sitting rooms and manufactured/mobile homes where local codes allow.
  • In Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.4).

Installation, framing and clearances (pp.6–18)

  • Front 36"; 0" at the back, sides, floor and top standoffs; ceiling 60" (restrictor in) or 46-1/2" (restrictor out) above the bottom of the fireplace.
  • The factory flue restrictor (above ZCV3622 serial #2016 / ZCVRB3622 #10674) must be removed for the low 33" enclosure (p.16).
  • No hearth required; island top-vent horizontal runs up to 20 ft (p.14).
  • Face covering non-combustible; combustible hearth no more than 3" high (p.17).

Accessories, liners and media (pp.19–38)

  • Surrounds, liners, Z36FK fan (speed control may mount outside the firebox) and the LOGC51 log set install per the accessory pages.
  • Replacement glass: 5 mm tempered, sealed with silicone rated to 500°F.

Gas (pp.39–49)

  • Natural gas supply 5.5" min / 7" normal / 9" max w.c.; manifold 3.5" high / 1.6" low w.c. (p.39).
  • Propane supply 11" min / 11" normal / 12" max w.c.; manifold 10" high / 6.3" low w.c. (p.39).
  • 3/8" NPT inlet; minimum 3/8" iron pipe for natural gas with at least 4.5" w.c. at the meter; 1/2" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1/2 psig (p.39).
  • Orifices are sized for 0–4,500 ft elevation (p.39). Field conversion between natural gas and propane uses Kingsman kits 3622-CKNG / -CKLP / -CKNGI / -CKLPI (and RB equivalents), installed by a qualified agency (pp.44–49).
  • Have the burner, pilot and venting inspected every year by a qualified technician.

IPI controls (pp.50–60)

  • Millivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.50–60).
  • IPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.
  • Proflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).

Venting (pp.61–70)

  • Vent: Kingsman 4"/7" flex, listed 4" x 6-5/8" rigid, 3"/3" co-linear (12 ft minimum) or PVH58 / PVH58FM power vent.
  • Maximum vertical 43 ft; maximum horizontal 20 ft with a 7 ft vertical; 1/4" rise per 12" of run.
  • Up to two 45° bends (18" each) plus two more 90° bends (36" each); remove the restrictor for runs under 15 ft.
  • Power venting: up to 125 ft; downward runs are not allowed on millivolt models.

First fire and everyday use

  • Break-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).
  • After turning it off, wait at least 60 seconds before relighting (p.5).
  • The glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).
  • Never burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).
  • Install carbon-monoxide detectors on every level and near bedrooms (p.7).

Building code information

Warranty

  • Coverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (ZCV3622/ZCVRB3622 installation and operating manual (36ZCV-MAN19), p.77).
  • Basic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.
  • Limited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.
  • Not covered by the one-year warranty: accent light bulbs, gasketing and paint.
  • Who is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.
  • Proof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.
  • How to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.
  • Key exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.

California Proposition 65

WARNING: This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

Flames and flame colors on the website may appear differently in real life.

Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.

Loading component details…

Add to cart to see your price.

Call for best price