Kingsman MCVST42H Heater See-Through Gas Fireplace MCVST42H
SKU / Model: MCVST42NH
Fireplace only$8,965.69
Early Black Friday Savings applied in your cart
Unlock an exclusive offer on this product.
Product overview
The Kingsman MCVST42H is a 42-inch two-sided see-through direct vent gas fireplace from Kingsman's multi-sided Clean View range. Glass on both faces lets one fire serve two rooms, such as a living room and dining room, or a kitchen and family room.
It is a dedicated Clean View appliance: no louvers, just a clean frame around the glass. Choose the flame display: the M42LOG4 eight-piece oak set on the M42LG log grate (natural gas), or the MST42GT glass tray with bronze ember glass, multi-coloured cannonballs or the M42LOG3 six-piece driftwood set. Traditional brick or porcelain reflective liners and ULK3 accent lighting (with the glass tray) complete the look.
Input is 31,000 BTU/h on natural gas and 29,250 BTU/h on propane with Hi/Lo adjustment, and Kingsman lists a fireplace efficiency (FE) of 66.45% MV / 68.58% IPI (NG); 67.88% / 70.36% (LP). This H model uses ceramic glass and is the heater-rated, higher-efficiency choice.
A millivolt valve (no house power needed) or IPI electronic ignition with battery backup both keep the fire going during a power failure. Wall thermostats and Proflame remotes, including thermostatic, modulating and light/fan-control versions, are available.
Venting is 5"/8" direct vent (Kingsman Z-Flex 5"/8" or a listed rigid system), horizontal or vertical, with PVH58 power vent compatibility for long runs.
The MCVST42 is the right pick for a fire shared between two rooms; for a three-sided view at the end of a wall, see the MCVP42 peninsula.
Key features
- Dedicated Clean View appliance: two-sided see-through design with no louvers.
- Direct vent: sealed combustion, 5"/8" venting.
- Hi/Lo millivolt or IPI valve: operates during a power failure with Hi/Lo heat and flame adjustment.
- Safety screen barrier: included.
- Ceramic (Robax or coated Neoceram) glass: heater rated, higher efficiency.
- Heat output: 31,000 / 21,000 BTU/h natural gas; 29,250 / 23,000 BTU/h propane (max/min).
- Efficiency: FE 66.45% MV / 68.58% IPI (NG); 67.88% / 70.36% (LP).
- Glass tray (optional): MST42GT for bronze glass media, cannonballs and the driftwood log set.
- Log sets (optional): M42LOG4 oak 8-piece (with the M42LG log grate, natural gas only) or M42LOG3 driftwood 6-piece (with the glass tray).
- Accent lighting (optional): ULK3 two-lamp light kit, used with the glass tray.
- Liners (optional): MST42PL porcelain reflective or MST42RLT traditional brick.
- Fan kit (optional): Z46FK heat activated with variable speed control.
- Surrounds (optional): ZCV42S1BL hearth-mount, ZCV42S1PFBL 4" picture frame or ZCV42S2PFBL 1-5/8" picture frame.
- Tile lip kit (optional): ZCVTLK.
- Thermostat (optional): Z2MT wall-mount millivolt or Z80PT programmable.
- Remote control (optional): thermostat on/off, thermostatic modulating, and modulating with fan control.
- Wall mount battery holder (optional): WMBH for the IPI backup batteries.
- Power vent compatible: PVH58 / PVH58FM.
- Field conversion: kits 42MST-CKLP / -CKNG (millivolt) and -CKLPI / -CKLP2 / -CKNGI / -CKNG2 (IPI).
- Certification: CSA/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.
Specifications
| Models | MCVST42NH / MCVST42LPH (millivolt); MCVST42NHE / MCVST42LPHE (IPI) |
|---|---|
| Type | Multi-sided (two-sided see-through) direct vent gas fireplace, top vent |
| Unit dimensions | 43-1/16" W x 51-1/4" H x 24-1/4" D (Kingsman specification) |
| Framing dimensions | Not published by the manufacturer as labeled values. Framing goes to the standoffs (0" back and top) with the enclosure ceiling at least 67" above the bottom of the fireplace |
| Viewing area | 33-11/16" W x 27-3/16" H |
| Clearances to combustibles | 24" in front (both viewing sides); back and top standoffs 0"; floor 0"; ceiling at least 67" above the bottom of the fireplace; 90° bend in the enclosure 2"; vertical pipe 1"; horizontal pipe 1-1/2" top, 1" sides and bottom (manual p.28); combustible mantel may begin 12-5/8" above the top of the opening, adjacent wall at least 1-1/2" from the standoff (p.27) |
| Input, natural gas (max / min) | 31,000 / 21,000 BTU/h |
| Input, propane (max / min) | 29,250 / 23,000 BTU/h |
| Fireplace efficiency (FE) | 66.45% MV / 68.58% IPI (NG); 67.88% / 70.36% (LP) |
| Glass | Ceramic (Robax or coated Neoceram), with safety screen barrier |
| Venting | 5"/8" direct vent, flex or rigid; PVH58 power vent compatible |
| Ignition | Hi/Lo millivolt or IPI with battery backup |
| Gas inlet | 3/8" NPT |
| Certification | CSA/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017 |
Dimensions and clearances
- Facing: face materials must be non-combustible; concrete board recommended 44" x 53"; a recessed combustible wall may sit no more than 3" above the header (p.14).
- Floor: no hearth is required; with vinyl flooring use a 12" hearth or raise the unit 24"; carpet needs a metal or wood panel.
- Appliance weight: not listed in the manual text.
What's included
- Fireplace with burner, set up for the selected fuel and ignition
- Ceramic (Robax or coated Neoceram) glass on all viewing sides
- Safety screen barriers
Required components
- A flame display: M42LG log grate with M42LOG4 oak logs (natural gas), or the MST42GT glass tray with 10 lb (2 bags) of Z5GC bronze glass media, RBCB1 cannonballs or M42LOG3 driftwood logs
- 5"/8" direct vent pipe and termination (Kingsman Z-Flex 5"/8" or a listed rigid system with the Z58DFA adapter where required)
- Non-combustible facing
- Gas supply with manual shutoff (3/8" NPT)
- 120 VAC grounded receptacle for IPI models and the fan kit
- Four AA batteries for IPI battery backup
Optional accessories
- 42MVB258 pilot shield for the glass tray and log grate
- ULK3 light kit
- MST42PL porcelain reflective
- MST42RLT traditional brick
- ZCV42S1BL hearth-mount
- ZCV42S1PFBL 4" picture frame
- ZCV42S2PFBL 1-5/8" picture frame
- Z46FK fan kit
- ZCVTLK tile lip kit
- Z2MT / Z80PT wall thermostats
- Proflame remotes (GT / EGT series)
- WMBH wall mount battery holder
- PVH58 / PVH58FM power vent
Downloads
- MCVST42 installation and operating manual (42MCVST-MAN19), includes the warranty
- MCVST42 brochure and specifications (June 2024)
- Kingsman 2025 product guide
Installation and safety notes
⚠ Important: this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (MCVST42 installation and operating manual (42MCVST-MAN19), information chapter). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.
Product and safety information (pp.2–9)
- Certified to CSA/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).
- Approved for manufactured/mobile homes where local codes allow (information chapter).
- In Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).
Installation, framing and clearances (pp.10–28)
- Clearances: 24" in front (both viewing sides); 0" at the back and top standoffs and floor; ceiling at least 67".
- Horizontal vent framing: 58-1/2" (natural gas) / 70-1/2" (propane) from the bottom of the fireplace, plus 1/4" per foot of rise.
- Facing: face materials must be non-combustible; concrete board recommended 44" x 53"; a recessed combustible wall may sit no more than 3" above the header (p.14).
- Mantel: a combustible mantel may begin 12-5/8" above the top of the opening; adjacent wall at least 1-1/2" from the standoff (p.27).
- No hearth is required; vinyl flooring needs a 12" hearth or a 24" raise.
Media, liners and accessories (pp.29–60)
- Glass tray MST42GT (not used with the brick liner on the MCVP42) or the M42LG log grate, which includes two grates, lava rock, embers and wool.
- Use only the log set approved for the grate or tray you choose, and keep the pilot uncovered.
- Replacement glass must be 5 mm Robax or coated Neoceram ceramic, sealed with silicone rated to 500°F; substitute glass voids the warranty.
Gas and maintenance (pp.29–60)
- Natural gas supply 5.5" min / 7" normal / 9" max w.c.; manifold 3.5" high / 1.6" low w.c. (p.52).
- Propane supply 11" min / 11" normal / 12" max w.c.; manifold 10" high / 6.3" low w.c. (p.52).
- 3/8" NPT inlet; minimum 3/8" iron pipe for natural gas with at least 4.5" w.c. at the meter; 1/2" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1/2 psig (p.52).
- Orifices are sized for 0–4,500 ft elevation (p.52). Field conversion between natural gas and propane uses Kingsman kits 42MST-CKLP / -CKNG (millivolt) and -CKLPI / -CKLP2 / -CKNGI / -CKNG2 (IPI), installed by a qualified agency (pp.57–59).
- Have the burner, pilot and venting inspected every year by a qualified technician.
Proflame controls (pp.61–75)
- Millivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.61–75).
- IPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.
- Proflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).
- Do not wire 120 V to millivolt switches or thermostats; switch-wire length is limited by gauge (e.g. 18 AWG up to 40 ft).
Venting (pp.76–84)
- Vent: Kingsman Z-Flex 5"/8" or approved 5"/8" direct vent systems (e.g. MG-DuraVent, Selkirk Direct-Temp); a 9" round hole is needed through masonry, 12" x 12" framing in combustible walls.
- Minimum vertical 58-1/2" (natural gas) / 70-1/2" (propane) from the bottom of the fireplace, plus 1/4" per foot of rise; maximum vertical 43 ft; maximum horizontal 20 ft (with 7 ft of vertical). Run limits follow the sibling MCVP42 manual's 5"/8" table.
- Up to two 45° bends in the horizontal run (18" each) plus two more 90° bends (36" each); remove the restrictor for runs under 15 ft.
- PVH58 / PVH58FM power vent approved; downward runs are not allowed on millivolt models, and IPI models must not use the cold-climate switch with power venting.
First fire and everyday use
- Break-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).
- After turning it off, wait at least 60 seconds before relighting (p.5).
- The glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).
- Never burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).
- Install carbon-monoxide detectors on every level and near bedrooms (p.7).
Building code information
- Install to local codes; where none exist, follow the current National Fuel Gas Code, ANSI Z223.1/NFPA 54, or in Canada CSA B149.1 (p.6).
- Electrical work: National Electrical Code, ANSI/NFPA 70, or in Canada CSA C22.1 Canadian Electrical Code (p.6).
- Manufactured homes: Manufactured Home Construction and Safety Standard, 24 CFR Part 3280 and ANSI/NFPA 501A; in Canada CAN/CSA Z240 MH (p.8).
- Carbon-monoxide detectors (Massachusetts and recommended practice): NFPA 720 and ANSI/UL 2034 (p.7).
- Massachusetts installations follow the Massachusetts fuel gas code (248 CMR) and 527 CMR (p.7).
Warranty
- Coverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (MCVST42 installation and operating manual (42MCVST-MAN19), p.89).
- Basic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.
- Limited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.
- Not covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.
- Who is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.
- Proof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.
- How to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.
- Key exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.
California Proposition 65
WARNING: This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Frequently asked questions — MCVST42H
What framing does the MCVST42H need?
It is a zero-clearance fireplace: framing goes to the standoffs with 0" at the back and top and 0" to the floor, with 24" clear in front of both viewing sides. The enclosure ceiling must be at least 67" above the bottom of the fireplace. The unit measures 43-1/16" W × 51-1/4" H × 24-1/4" D.
What venting does it use, and how far can it run?
It vents off the top with 5"/8" direct vent pipe, flex or rigid. The vent needs a minimum vertical rise of 58-1/2" (natural gas) or 70-1/2" (propane) from the bottom of the fireplace, and runs go up to 43 ft vertical or 20 ft horizontal with 7 ft of vertical. It is also compatible with the PVH58 power vent.
Can the MCVST42H run on propane?
Yes. It comes as MCVST42NH / MCVST42LPH (millivolt) and MCVST42NHE / MCVST42LPHE (IPI), rated 31,000 / 21,000 BTU/h (max/min) on natural gas and 29,250 / 23,000 BTU/h on propane. Field conversion kits are 42MST-CKLP (millivolt) or 42MST-CKLPI / 42MST-CKLP2 (IPI).
Does it work in a power outage?
Yes. Millivolt models need no electricity at all. IPI models keep the fire running on four AA backup batteries; the fans and lights do not run on battery.
What's the warranty?
Defective components are covered for parts and labour for the first year after installation, except accent light bulbs, gasketing, glass fronts and paint. The heat exchanger, combustion chamber and burner carry a limited lifetime warranty for as long as the original owner owns the fireplace; after the first year the defective part is exchanged, and labour and freight are not covered.
How high must a mantel be?
A combustible mantel may begin 12-5/8" above the top of the opening, and an adjacent wall must be at least 1-1/2" from the standoff.
Loading component details…
Add to cart to see your price.