Kingsman IDV26 Direct Vent Gas Fireplace Insert IDV26

SKU / Model: IDV26N

Free Fast Shipping
In-stock items are processed in 1–2 business days.

$3,367.72

Early Black Friday Savings applied in your cart

YOUR SPECIAL OFFER IS AVAILABLE

This product qualifies for an exclusive special offer.

Complete your selections and add this product to your cart to unlock the eligible offer.

Offer eligibility and final promotional pricing are confirmed in the cart. Accessories qualify separately. Offers may change.

Product overview

The Kingsman IDV26 is a direct vent gas fireplace insert that turns an existing wood-burning masonry fireplace, or a listed zero-clearance factory-built fireplace, into a clean, efficient gas fire. It is the wide model of Kingsman's IDV insert range and suits homeowners who want real heat and push-button convenience from a fireplace they rarely use.

A dual burner with glowing embers lights up the LOGF27 Fibre Split Oak seven-piece log set, or RSP10 glass support platform with bronze glass. Inside, choose a brick or porcelain reflective liner (IDV26PRL porcelain reflective or IDV26RL refractory brick liner); outside, finish the opening with a I26CV1BL, I26CV2BL or I26CV3BL Clean View front, or I26CVPF1BL / I26CVPF2BL picture-frame Clean View and a matching surround (I26S1BL slim, I26SPF1BL slim picture frame or I26SUBL universal surround).

Input is 28,500 BTU/h on natural gas and 28,000 BTU/h on propane with adjustable flame, and Kingsman lists a fireplace efficiency (FE) of 65.25% MV / 67.37% IPI (NG); 66.30% / 68.30% (LP). Heat-radiating ceramic glass and a heat-activated blower with variable speed control push warmth into the room, making it effective zone heat.

Choose a millivolt valve that needs no house power, or IPI electronic ignition with battery backup; both keep working in a power outage. Proflame 2 (E2) models include a remote with flame, fan, thermostat and smart-thermostat control. Millivolt and PF1 models work with optional wall thermostats and Kingsman remotes.

It vents through the existing chimney with a 3"/3" co-linear co-linear aluminium liner to a IDVVT36 termination on top, with a 12 ft minimum and 40 ft maximum vertical run, so no new chimney is needed.

The IDV26 is the wide, heat-focused insert of the range, with heat-radiating ceramic glass and a standard heat-activated blower; its CV1/CV2 layouts fit wide but shallow openings.

Key features

  • Direct vent fireplace insert: sealed combustion for existing masonry or listed factory-built fireplaces.
  • Dual burner: with glowing embers.
  • Millivolt or IPI valve: operates during power failures, with adjustable flame control.
  • Heat-radiating ceramic glass: Robax or coated Neoceram, 5 mm.
  • Heat-activated blower: with variable speed control.
  • On/off rocker switch: for simple manual operation.
  • Proflame 2 remote (E2 models): flame, fan, thermostat and smart-thermostat control; battery backup.
  • Safety screen barrier: included with the Clean View front.
  • Heat output: 28,500 / 19,500 BTU/h natural gas; 28,000 / 23,000 BTU/h propane (max/min).
  • Efficiency: FE 65.25% MV / 67.37% IPI (NG); 66.30% / 68.30% (LP).
  • Approvals: bedroom and mobile/manufactured home (USA) approved.
  • Flame display: LOGF27 Fibre Split Oak seven-piece log set, or RSP10 glass support platform with bronze glass.
  • Clean View fronts: I26CV1BL, I26CV2BL or I26CV3BL Clean View front, or I26CVPF1BL / I26CVPF2BL picture-frame Clean View.
  • Surrounds: I26S1BL slim, I26SPF1BL slim picture frame or I26SUBL universal surround.
  • Liners (optional): IDV26PRL porcelain reflective or IDV26RL refractory brick liner.
  • Risers (optional): I33R40 / I33R44 risers to fit taller openings.
  • Mantel clearance shield (optional): I33CS lowers the minimum combustible mantel height.
  • Wall thermostat (optional): standard on/off or programmable.
  • Remote control (optional, millivolt / PF1): on/off, thermostatic, thermostatic modulating and fan control.
  • Co-linear venting: 3"/3" co-linear.
  • Field conversion: kits 26IDV-CKLP / -CKNG (millivolt) and -CKLPI / -CKLP2 / -CKNGI / -CKNG2 (IPI).
  • Certification: CSA/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.

Specifications

Models IDV26N / IDV26LP (millivolt); IDV26NE2 / IDV26LPE2 (IPI Proflame 2 with remote)
Type Direct vent gas fireplace insert
Input, natural gas (max / min) 28,500 / 19,500 BTU/h
Input, propane (max / min) 28,000 / 23,000 BTU/h
Fireplace efficiency (FE) 65.25% MV / 67.37% IPI (NG); 66.30% / 68.30% (LP)
Insert size 33" W (components in) or 28" W (components out) x 19-1/2" H x 14-1/4" D
Minimum fireplace opening at least 33" W x 19-1/2" H x 14-1/4" D with components in, or 28" W with the CV2 components-out layout (pp.1, 12)
Glass Ceramic (Robax or coated Neoceram), 5 mm
Venting 3"/3" co-linear; IDVVT36 vertical termination
Ignition Millivolt or IPI with battery backup
Blower Heat-activated, variable speed (standard)
Gas inlet 3/8" NPT
Certification CSA/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017

Dimensions and clearances

  • Insert: 33" W (components in) or 28" W (components out) x 19-1/2" H x 14-1/4" D (Kingsman spec table).
  • Minimum fireplace opening: at least 33" W x 19-1/2" H x 14-1/4" D with components in, or 28" W with the CV2 components-out layout (pp.1, 12).
  • Mantel: with a Clean View front and no shield, 35-3/8" to 45-3/8" from the unit bottom depending on mantel depth (p.33); with the I33CS shield, 28-1/2" to 38-1/2" (p.35); hearth at least 3/4" x 12-1/2" x 31" (p.34).
  • The floor beneath the insert must be non-combustible; keep 1/2" around the Clean View so it can be removed for service.
  • Venting: 12 ft minimum and 40 ft maximum vertical; horizontal offset up to 2 ft.
  • Appliance weight: not listed in the manual text.

What's included

  • Insert with dual burner and heat-activated variable-speed blower, set up for the selected fuel and ignition
  • Ceramic glass front
  • Proflame 2 remote on E2 models

Required components

  • A Clean View front: I26CV1BL, I26CV2BL or I26CV3BL Clean View front, or I26CVPF1BL / I26CVPF2BL picture-frame Clean View
  • A flame display: LOGF27 Fibre Split Oak seven-piece log set, or RSP10 glass support platform with bronze glass
  • Co-linear venting: 3"/3" co-linear with the IDVVT36 termination (25 ft kit)
  • IDVLCP lower chase block-off plate, sealed with red RTV silicone
  • Gas supply with manual shutoff (3/8" NPT)
  • 120 VAC grounded receptacle
  • A clean, sound chimney not shared with any solid-fuel appliance

Optional accessories

  • I26S1BL slim
  • I26SPF1BL slim picture frame
  • I26SUBL universal surround
  • IDV26PRL porcelain reflective
  • IDV26RL refractory brick liner
  • I33R40 / I33R44 risers
  • I33CS mantel clearance shield
  • Z2MT / Z80PT wall thermostats
  • Proflame remotes (GT / EGT series, millivolt and PF1 models)
  • WMBH wall mount battery holder (IPI)

Downloads

Installation and safety notes

⚠ Important: this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (IDV26 installation and operating manual (26IDV-MAN19), safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.

Product and safety information (pp.4–11)

  • Certified to CSA/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).
  • Approved for bedrooms and for manufactured/mobile homes in the USA where local codes allow.
  • In Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).

Fireplace requirements, dimensions and mantel (pp.12–27)

  • Fits a masonry fireplace (leave the refractory in place) or a listed zero-clearance factory-built fireplace; minimum opening at least 33" W x 19-1/2" H x 14-1/4" D with components in, or 28" W with the CV2 components-out layout (pp.1, 12).
  • In a factory-built fireplace, the damper, grates, glass doors, screen rails and smoke baffle may need to be removed per the manual.
  • Mantel: with a Clean View front and no shield, 35-3/8" to 45-3/8" from the unit bottom depending on mantel depth (p.33); with the I33CS shield, 28-1/2" to 38-1/2" (p.35); hearth at least 3/4" x 12-1/2" x 31" (p.34).
  • Non-combustible floor beneath the insert; non-combustible facing in the area above the combustible-mantel line.

Fronts, surrounds, liners and media (pp.12–27, 30–44)

  • Fronts: I26CV1BL, I26CV2BL or I26CV3BL Clean View front, or I26CVPF1BL / I26CVPF2BL picture-frame Clean View. Surrounds: I26S1BL slim, I26SPF1BL slim picture frame or I26SUBL universal surround.
  • Media: LOGF27 Fibre Split Oak seven-piece log set, or RSP10 glass support platform with bronze glass; follow the placement diagram and keep the pilot clear.
  • Replacement glass must be 5 mm Robax or coated Neoceram; substitute glass voids the warranty.

Gas (pp.45–51)

  • Natural gas supply 5.5" min / 7" normal / 9" max w.c.; manifold 3.5" high / 1.6" low w.c. (p.48).
  • Propane supply 11" min / 11" normal / 12" max w.c.; manifold 10" high / 6.3" low w.c. (p.48).
  • 3/8" NPT inlet; minimum 3/8" iron pipe for natural gas with at least 4.5" w.c. at the meter; 1/2" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1/2 psig (p.48).
  • Orifices are sized for 0–4,500 ft elevation (p.48). Field conversion between natural gas and propane uses Kingsman kits 26IDV-CKLP / -CKNG (millivolt) and -CKLPI / -CKLP2 / -CKNGI / -CKNG2 (IPI), installed by a qualified agency (pp.50–51).
  • Have the burner, pilot and venting inspected every year by a qualified technician.

Controls and electrical (pp.51–65)

  • Millivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.51–65).
  • IPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.
  • Proflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).
  • Grounded three-prong plug required for the blower; do not wire 120 V to millivolt switches.

Venting (pp.68–73)

  • Co-linear liner: 3"/3" co-linear, Kingsman flex or MG-DuraVent; termination IDVVT36.
  • Vertical rise 12 ft minimum, 40 ft maximum; up to 2 ft of horizontal offset.
  • The chimney must be cleaned and inspected (professionally if it served a wood fire), must not serve a solid-fuel appliance, and needs a rain cap with the gap between chimney and liner capped.
  • Seal the lower chase with the IDVLCP block-off plate.

First fire and everyday use

  • Break-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).
  • After turning it off, wait at least 60 seconds before relighting (p.5).
  • The glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).
  • Never burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).
  • Install carbon-monoxide detectors on every level and near bedrooms (p.7).

Building code information

Warranty

  • Coverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (IDV26 installation and operating manual (26IDV-MAN19), p.73).
  • Basic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.
  • Limited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.
  • Not covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.
  • Who is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.
  • Proof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.
  • How to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.
  • Key exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.

California Proposition 65

WARNING: This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

Flames and flame colors on the website may appear differently in real life.

Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.

Loading component details…

Add to cart to see your price.

Call for best price