Kingsman HBZDV3624 36" Direct Vent Gas Fireplace HBZDV3624
SKU / Model: HBZDV3624N
Fireplace only$2,439.15
Early Black Friday Savings applied in your cart
Unlock an exclusive offer on this product.
Product overview
The Kingsman HBZDV3624 is a 36-inch zero-clearance direct vent gas fireplace with a traditional, full-depth firebox and a log fire, and the decorative 36-inch model of the HBZDV pair, with tempered glass and the lowest input; the HBZDV3628 adds ceramic glass and more output in the same size. It gives the look of a wood-burning fireplace with push-button convenience, on an interior or exterior wall, in a corner or as an island.
A dual burner sends a realistic flame across the LOGC44 Burnt Oak eight-piece log set Kingsman specifies (sold separately), behind a 29-3/4" W x 18-5/8" H tempered glass front. Finish the face with louvers and the HB36GBL grill kit or the louver-free HB36CVCK Clean View kit, and add a brick or porcelain liner. Input is 24,000 BTU/h on natural gas with Hi/Lo adjustment, at a fireplace efficiency of 50.48% MV / 52.30% IPI (NG); 52.59% / 54.24% (LP).
Millivolt and IPI models both keep running in a power failure, and a flame sensor shuts off the gas if the pilot is not sensed. It vents 4"/7" through the wall or roof, or with the optional PVH58 power vent. A wall thermostat, Proflame remote or the Z36FK fan kit add control and heat circulation.
Key features
- Traditional direct vent fireplace: sealed combustion with outside air for the fire; 4"/7" venting horizontal or vertical.
- Zero-clearance installation: 0" to combustibles at the back, sides, floor and top standoffs (manual p.14).
- Hi/Lo millivolt or IPI valve: both operate during a power failure, with Hi/Lo heat and flame adjustment.
- Dual burner: with a realistic flame pattern.
- Pilot flame sensor: constantly monitors the pilot and provides 100% gas shut-off if the pilot is not sensed.
- Safety screen barrier: included over the glass.
- Tempered glass: 29-3/4" W x 18-5/8" H viewing area; decorative rating.
- Heat output: 24,000 / 14,000 BTU/h max/min natural gas.
- Efficiency: FE 50.48% MV / 52.30% IPI (NG); 52.59% / 54.24% (LP) (Kingsman specification).
- LOGC44 log set: the Kingsman log set required for this fireplace (sold separately).
- Designer Clean View Circulating Kit (optional): HB36CVCK: no louvers required.
- Grill kit (optional): HB36GBL in black, for louvered installations.
- Surround (optional): HB36SBL black, covers 35-1/2" H x 41-1/8" W on louvered units.
- Fan kit (optional): Z36FK heat-activated fan with variable speed control (120 V, 0.4 A).
- Liners (optional): HB36RLT traditional brick, HB36RLH herringbone brick or HB36PL porcelain reflective.
- Thermostat (optional): Z2MT wall-mount millivolt thermostat or Z80PT programmable thermostat.
- Remote control (optional): thermostat on/off, thermostatic modulating, and thermostatic modulating with fan control.
- Proflame 2 remote (IPI PF2 models): flame-height modulation and multi-colour LED accent lighting control.
- Wall mount battery holder (optional): WMBH keeps the IPI backup batteries in an accessible wall box.
- Power vent compatible: PVH58 / PVH58FM for extended horizontal runs.
- Field conversion: conversion kits 3624HB-CKLP / -CKNG (millivolt) and -CKLPI / -CKNGI / -CKLP2 / -CKNG2 (IPI).
- Approvals and certification: CSA/ANSI Z21.88-19 / CSA 2.33-19, CSA 2.17-2017 (high altitude); manufactured/mobile home approved.
Specifications
| Models | NG millivolt (HBZDV3624N) and NG IPI (HBZDV3624NE) on this listing |
|---|---|
| Type | Zero-clearance direct vent gas fireplace, top vent |
| Unit dimensions | With the Designer Clean View kit: 38-1/16" W x 34-11/16" H x 18-7/8" D; with louvers: 36" W x 34-13/16" H x 16-7/16" D (Kingsman specification) |
| Framing dimensions | Rough-opening dimensions are not published by the manufacturer as labeled values. Framing runs flush to the standoffs at 0" (back, sides and top), with the ceiling at least 60" above the bottom of the fireplace |
| Viewing area | 29-3/4" W x 18-5/8" H |
| Clearances to combustibles | Back, sides, floor and top standoffs 0"; ceiling at least 60" above the bottom of the fireplace; vent pipe 3-1/2" above a 90° bend in a 42–43" enclosure, 2-1/2" over 43"; top of horizontal pipe 1-1/2", sides and bottom 1"; vertical pipe 1" (Kingsman flex) or 1-1/4" (rigid) (manual p.14); front: non-combustible facing may reach the front face but must not cover the grill or door areas unless the clean view kit is used; floor: a louvered unit may sit with the combustible floor up to 1" above the firebox bottom (up to 7" with the clean view kit); with vinyl flooring use a 12" hearth or raise the unit 24"; carpet may run 1" onto a metal or wood panel (pp.11–14); mantels: mantel figures show 31-3/8" and 28-1/4" to the floor (p.16) |
| Input, natural gas (max / min) | 24,000 / 14,000 BTU/h |
| Input, propane (max / min) | 22,000 / 15,000 BTU/h (LP models) |
| Fireplace efficiency (FE) | 50.48% MV / 52.30% IPI (NG); 52.59% / 54.24% (LP) |
| Glass | Tempered, with safety screen barrier |
| Venting | 4"/7" Kingsman flex or 4" x 6-5/8" rigid direct vent |
| Ignition | Hi/Lo millivolt or IPI with battery backup |
| Gas inlet | 3/8" NPT |
| Fan kit | Optional Z36FK, 120 V 60 Hz 0.4 A |
| Log set | LOGC44 (required, sold separately) |
| Certification | CSA/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017 |
Dimensions and clearances
- Appliance weight: not listed in the manual text.
Included components
- Fireplace with dual burner, set up for the selected fuel and ignition
- Tempered glass front
- Safety screen barrier kit
- Nailing tabs and standoffs
Required components
- LOGC44 log set (Kingsman specifies it for this model; sold separately)
- 4"/7" direct vent pipe and termination (Kingsman Z-Flex or a listed 4" x 6-5/8" rigid system with the ZDVDFA adapter)
- Either louvers with the HB36GBL grill kit or the HB36CVCK Designer Clean View Circulating Kit to finish the face
- Gas supply with a manual shutoff valve (3/8" NPT inlet)
- 120 VAC grounded receptacle for the fan kit or IPI models
- Four AA batteries for IPI battery backup
Optional accessories
- HB36CVCK Designer Clean View Circulating Kit
- HB36GBL black grill kit
- HB36SBL black surround
- HB36RLT traditional brick liner
- HB36RLH herringbone brick liner
- HB36PL porcelain reflective liner
- Z36FK fan kit with variable speed control
- Z2MT digital wall thermostat
- Z80PT programmable wall thermostat
- GTRC millivolt remote
- GTMRCN millivolt remote
- GTMRCP millivolt remote
- GTFRCN millivolt remote
- GTFRCP millivolt remote
- EGTRC IPI Proflame remote
- EGTMRCN IPI Proflame remote
- EGTMRCP IPI Proflame remote
- EGTFRCN IPI Proflame remote
- EGTFRCP IPI Proflame remote
- WMBH wall mount battery holder (IPI)
- PVH58 power vent
- PVH58FM flush-mount power vent
Downloads
- HBZDV3624/3628 installation and operating manual (36HB-MAN19), includes the warranty
- Kingsman brochure and specifications
- Kingsman 2025 product guide
Installation and safety notes
⚠ Important: this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (HBZDV3624/3628 installation and operating manual (36HB-MAN19), cover and safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.
Product and safety information (pp.2–9)
- Certified to CSA/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).
- Approved for manufactured/mobile homes where local codes allow (manual mobile home section).
- Indoor appliance. A covered outdoor location is allowed only for basic millivolt models without fan or lights, with a roof overhang, and needs the local authority's approval (p.10).
- In Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.8).
Installation, framing and clearances (pp.10–17)
- 0" clearance at the back, sides, floor and top standoffs; ceiling at least 60" above the bottom of the fireplace.
- Non-combustible facing may reach the front face but must not cover the grill or door areas (unless the clean view kit is used); combustible material can run flush to the standoffs; finishes near the opening must withstand 250°F.
- Mantels: mantel figures show 31-3/8" and 28-1/4" to the floor (p.16).
- Vinyl flooring: 12" minimum hearth, or raise the unit 24" (installer's risk).
Accessories, liners and logs (pp.18–22)
- Use only the LOGC44 log set and follow the log-placement diagram; the pilot must stay visible and uncovered.
- Fan kit Z36FK: 120 V 60 Hz 0.4 A with a wall-mounted variable speed control; never connect the 120 V fan to the millivolt valve.
- Replacement glass must be 5 mm tempered; substitute glass voids the warranty.
Gas (pp.39–46)
- Natural gas supply 5.5" min / 7" normal / 9" max w.c.; manifold 3.5" high / 1.6" low w.c. (p.39).
- Propane supply 11" min / 11" normal / 12" max w.c.; manifold 10" high / 6.3" low w.c. (p.39).
- 3/8" NPT inlet; minimum 3/8" iron pipe for natural gas with at least 4.5" w.c. at the meter; 1/2" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1/2 psig (p.39).
- Orifices are sized for 0–4,500 ft elevation (p.39). Field conversion between natural gas and propane uses Kingsman kits 3624HB-CKLP / -CKNG (millivolt) and -CKLPI / -CKNGI / -CKLP2 / -CKNG2 (IPI), installed by a qualified agency (pp.42–44).
- Have the burner, pilot and venting inspected every year by a qualified technician.
Controls and electrical (pp.47–62)
- Millivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.47–62).
- IPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.
- Proflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).
- Do not wire 120 V to millivolt switches or thermostats; switch-wire length is limited by wire gauge.
Venting (pp.63–71)
- Vent: 4"/7" Kingsman flex or approved rigid systems; propane horizontal runs need at least 1 ft of vertical rise off the flue first (pp.63–71).
- Minimum vertical 4 ft; maximum vertical 40 ft (43 ft with roof-vent systems); maximum horizontal 20 ft; 1/4" rise per 12" of horizontal run.
- Up to two 45° bends in the horizontal run (each takes 18" off the allowed run) plus two more 90° bends (36" each); remove the flue restrictor for runs under 15 ft.
- Keep the termination 24" from obstructions and flammable materials, and never recess it into the wall; a PVH58 power vent is approved for Proflame 2 models.
First fire and everyday use
- Break-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).
- After turning it off, wait at least 60 seconds before relighting (p.5).
- The glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).
- Never burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).
- Install carbon-monoxide detectors on every level and near bedrooms (p.7).
Building code information
- Install to local codes; where none exist, follow the current National Fuel Gas Code, ANSI Z223.1/NFPA 54, or in Canada CSA B149.1 (p.7).
- Electrical work: National Electrical Code, ANSI/NFPA 70, or in Canada CSA C22.1 Canadian Electrical Code (p.7).
- Manufactured homes: Manufactured Home Construction and Safety Standard, 24 CFR Part 3280 and ANSI/NFPA 501A; in Canada CAN/CSA Z240 MH (p.9).
- Carbon-monoxide detectors (Massachusetts and recommended practice): NFPA 720 and ANSI/UL 2034 (p.8).
- Massachusetts installations follow the Massachusetts fuel gas code (248 CMR) and 527 CMR (p.8).
Warranty
- Coverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (HBZDV3624/3628 installation and operating manual (36HB-MAN19), p.77).
- Basic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.
- Limited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.
- Not covered by the one-year warranty: accent light bulbs, gasketing and paint.
- Who is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.
- Proof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.
- How to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.
- Key exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.
California Proposition 65
WARNING: This product can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Frequently asked questions — HBZDV3624
What framing does the HBZDV3624 need?
It is a zero-clearance fireplace: framing runs flush to the standoffs with 0" at the back, sides and top, and 0" to the floor, with the ceiling at least 60" above the bottom of the fireplace. The unit measures 38-1/16" W × 34-11/16" H × 18-7/8" D with the Designer Clean View kit, or 36" W × 34-13/16" H × 16-7/16" D with louvers.
What venting does it use, and how far can it run?
It vents off the top with 4"/7" direct vent pipe (Kingsman Z-Flex flex, or a listed 4" x 6-5/8" rigid system with the ZDVDFA adapter). Vertical runs go from 4 ft minimum to 40 ft maximum (43 ft with roof-vent systems), and horizontal runs up to 20 ft, rising 1/4" per foot; propane horizontal runs need at least 1 ft of vertical rise off the flue first. A PVH58 power vent is approved for Proflame 2 models.
Can the HBZDV3624 run on propane?
Yes. This listing carries the natural gas millivolt (HBZDV3624N) and IPI (HBZDV3624NE) models, rated 24,000 / 14,000 BTU/h (max/min); propane models are rated 22,000 / 15,000 BTU/h. Field conversion uses Kingsman kits 3624HB-CKLP / -CKNG (millivolt) and -CKLPI / -CKNGI / -CKLP2 / -CKNG2 (IPI).
Does it work in a power outage?
Yes. Millivolt models need no electricity at all. IPI models keep the fire running on a battery backup; the fan and lights do not run on battery.
Is a log set included?
No. The LOGC44 Burnt Oak eight-piece log set is required for this fireplace and sold separately, and it is the only log set approved for it.
Can it be installed in a bedroom?
Yes. It is certified as a vented gas fireplace heater (CSA/ANSI Z21.88) for installation in a bedroom or bed-sitting room; in Canada it must be installed with a listed millivolt thermostat. It is also approved for manufactured/mobile homes where local codes allow.
Loading component details…
Add to cart to see your price.

