Kingsman FDV451 Direct Vent Gas Stove FDV451
SKU / Model: FDV451N
Fireplace only$2,621.48
Early Black Friday Savings applied in your cart
Unlock an exclusive offer on this product.
Product overview
The Kingsman FDV451 is a freestanding direct vent gas stove with a traditional cast-stove look in charcoal with flat black posts. It brings real stove character to living rooms, cottages, basements and additions with no chimney, and it is approved for bedrooms, bed-sitting rooms and, as a direct vent stove, mobile homes.
A dual burner lights a realistic fire on the LOGF451 five-piece cast split oak log set over lava rock and embers, or on bronze glass with optional RBCB1 cannonballs. Inside, choose an F451RLT traditional or F451RLH herringbone brick liner or an F451PL reflective porcelain liner; the F450FBL door front and F451SDSBL side doors complete the body.
Input is 34,500 BTU/h on natural gas and 31,000 BTU/h on propane, with Hi/Lo flame and heat adjustment and a fireplace efficiency of up to 67.72% (NG) and 74.06% (LP). A millivolt valve needs no house power and IPI ignition has battery backup, so it keeps heating in a power outage; E2 models include a Proflame 2 remote. It vents through the wall or roof from a 4"/7" collar, or into an existing chimney or B-vent with the F35BVC converter.
Key features
- Freestanding direct vent stove: sealed combustion; outside air for the fire.
- Millivolt or IPI valve: operates during a power failure with Hi/Lo heat and flame adjustment.
- Proflame 2 remote (E2 models): flame, fan, thermostat and smart thermostat control, with battery backup.
- Dual burner: with a realistic flame pattern.
- Heat-radiating ceramic glass: Robax or coated Neoceram, 5 mm.
- Log set: LOGF451 oak log set (or bronze glass / cannonballs with the media kit).
- Safety screen barrier: supplied with the F450FBL door front.
- Heat output: 34,500 / 23,750 BTU/h natural gas; 31,000 / 24,500 BTU/h propane (max/min).
- Efficiency: FE 65.89% MV / 67.72% IPI (NG); 72.14% / 74.06% (LP).
- Approvals: mobile home approved (direct vent only); bedroom and bed-sitting room approved.
- Fan kit (optional): F45FK heat activated with variable speed control.
- Wall thermostat (optional): Z2MT millivolt or Z80PT programmable.
- Remote control (optional, millivolt): on/off, thermostatic, thermostatic modulating.
- Log grate (optional): F45LG.
- Bronze glass media (optional, in place of logs): Z5GC (3 bags) or MQG5C, 15 lb maximum.
- Multi-coloured cannonballs (optional): RBCB1.
- Traditional brick liner (optional): F451RLT.
- Herringbone brick liner (optional): F451RLH.
- Porcelain reflective liner (optional): F451PL.
- Charcoal door face and vent lid (required, sold separately): F450FBL, with flat black posts and safety screen; the vent lid must be installed before venting (manual p.18).
- Charcoal solid-panel side doors (required, sold separately): F451SDSBL; side doors are listed as required for each unit.
- Decorative black 7" collar (optional): F7DBC.
- Decorative black wall trim plate (optional): F7DTP.
- B-vent adapter (optional): F35BVC converts the stove to an existing 4" B-vent or lined chimney.
- Field conversion: kits 450DV-CKNG / -CKLP (millivolt) and -CKNGI / -CKNG2 / -CKLPI / -CKLP2 (IPI).
- Certification: CSA/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017.
Specifications
| Models | FDV451N / FDV451LP (millivolt); FDV451NE2 / FDV451LPE2 (IPI Proflame 2 with remote) |
|---|---|
| Type | Freestanding direct vent gas stove |
| Unit dimensions | Not published by the manufacturer |
| Framing dimensions | None required (freestanding). Alcove installation: at least 48" deep, 71-1/2" high and 58" wide |
| Viewing area | Not published by the manufacturer |
| Clearances to combustibles | Front 36"; sides 15-1/2"; back 2-1/2"; ceiling 71-1/2" from the floor; top of a 90° elbow 2"; top of horizontal pipe 1"; vertical venting 1". Floor: may sit directly on carpet, tile or other combustible flooring with no added floor protection; a hearth is recommended over vinyl flooring |
| Input, natural gas (max / min) | 34,500 / 23,750 BTU/h |
| Input, propane (max / min) | 31,000 / 24,500 BTU/h |
| Fireplace efficiency (FE) | 65.89% MV / 67.72% IPI (NG); 72.14% / 74.06% (LP) |
| Glass | Ceramic, 5 mm |
| Venting | Direct vent, 4"/7" flue collar. Rigid DuraVent DirectVent Pro 4" x 6-5/8" pipe with the Kingsman ZDVDKA stove adapter (horizontal or vertical termination); optional 4" B-vent with F35BVC |
| Ignition | Millivolt or IPI Proflame 2 |
| Gas inlet | 3/8" NPT |
| Certification | CSA/ANSI Z21.88-19, CSA 2.33-19, CSA 2.17-2017 |
Included components
- Stove with dual burner, set up for the selected fuel and ignition
- Ceramic glass (5 mm Robax or coated Neoceram)
- Lava rock and embers (supplied with the base unit)
- Proflame 2 remote (FDV451NE2 / FDV451LPE2 only)
Required components
- LOGF451 five-piece cast split oak log set (listed as required for each unit), or bronze glass media in its place: Z5GC (3 bags) or MQG5C, 15 lb maximum; RBCB1 cannonballs are used with 15 lb of glass
- F450FBL door front, charcoal with flat black posts: door face with safety screen and vent lid (required for each unit; the vent lid must be in place before the venting is connected)
- F451SDSBL side doors, flat black frame with charcoal solid panel (side doors are listed as required for each unit)
- Direct vent pipe from the 4"/7" collar: Kingsman (Z-Flex) venting components labelled for this stove, or DuraVent DirectVent Pro / DirectVent Pro Concentric Flex; BDM Pro Form, Ameri-Vent, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp are also approved
- ZDVDKA DuraVent hard-pipe stove adapter (required with rigid DuraVent pipe)
- One termination: FDVHSQ or FDVHT horizontal, Z47ST24 / Z47ST36 snorkel, or FDVVT40 / Z47VT vertical
- Vertical installs: ZDVFS firestop spacer (required through floors and ceilings), ZDVAIS attic insulation shield (required through attic space), ZDV7SC storm collar and a ZDVAAF, ZDVAF2 or ZDVAF3 roof flashing
- Or, instead of direct vent pipe: F35BVC B-vent converter into an existing 4" B-vent or lined chimney, 12 ft minimum to 60 ft maximum (direct vent models only are mobile home approved)
- Gas supply with manual shutoff (3/8" NPT)
- 120 VAC grounded receptacle for the fan or IPI models
- Four AA batteries for IPI battery backup
Optional accessories
- F45LG log grate
- F451RLT traditional brick liner
- F451RLH herringbone brick liner
- F451PL reflective porcelain liner (one back and two side panels)
- RBCB1 multi-coloured cannonballs
- F45FK fan kit with variable speed control
- F7DBC decorative black collar, 7"
- FV7FBT decorative brass collar, 7"
- F7DTP decorative black wall trim plate
- Z2MT millivolt wall thermostat
- Z80PT programmable digital millivolt wall thermostat
- GFRC on/off remote (millivolt / IPI)
- GTRC thermostat remote (millivolt)
- GTMRCN / GTMRCP thermostat / modulating remote, natural gas / propane (millivolt)
- GTFRCN / GTFRCP thermostat / modulating remote with fan control (millivolt)
- WMBH wall mount battery holder (IPI models)
- ZDVSSLR vinyl siding shield
Downloads
- FDV451 installation and operating manual (451-MAN19), includes the warranty
- FDV451 brochure and specifications (Dec 2025)
- Kingsman 2025 product guide
Installation and safety notes
⚠ Important: this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Kingsman requires that it be installed and serviced by a qualified installer, service agency or gas supplier, following the installation manual and local codes (FDV451 installation and operating manual (451-MAN19), safety pages). If you ever smell gas, do not try to light any appliance, do not touch electrical switches or use a phone in the building, leave the building and call your gas supplier from a neighbour's phone.
Product and safety information (pp.2–8)
- Certified to CSA/ANSI Z21.88-19, CSA 2.33-19 and CSA 2.17-2017 (manual cover). It is supplemental heat, not a primary heat source (p.6).
- Mobile home approved (direct vent only; not when converted to B-vent); approved for bedrooms and bed-sitting rooms.
- In Massachusetts the installer must be a licensed plumber or gas fitter, with a listed T-handle gas shutoff and CO detectors as required by state code (p.7).
Location, clearances and floor (pp.9–10)
- Clearances: front 36", sides 15-1/2", back 2-1/2"; ceiling 71-1/2" from the floor; top of a 90° elbow 2"; horizontal pipe top 1"; vertical vent 1" (p.9).
- Alcove: at least 48" deep, 71-1/2" high and 58" wide (p.9).
- Install on a hard, stable surface; carpet and tile are fine, a hearth is recommended over vinyl.
Accessories, liners and logs (pp.11–23)
- F45FK fan: variable speed control, needs a grounded 120 VAC receptacle.
- Log set: LOGF451 oak log set (or bronze glass / cannonballs with the media kit); follow the placement diagram and keep the pilot clear.
- Replacement glass must be 5 mm Robax or coated Neoceram; substitute glass voids the warranty.
Gas, maintenance and conversion (pp.38–44)
- Natural gas supply 5.5" min / 7" normal / 9" max w.c.; manifold 3.5" high / 1.6" low w.c. (p.10).
- Propane supply 11" min / 11" normal / 12" max w.c.; manifold 10" high / 6.3" low w.c. (p.10).
- 3/8" NPT inlet; minimum 3/8" iron pipe for natural gas with at least 4.5" w.c. at the meter; 1/2" rigid pipe or an approved flex connector such as FP15GC; a union and sediment trap are required. Disconnect the appliance for pressure tests above 1/2 psig (p.10).
- Orifices are sized for 0–4,500 ft elevation (p.10). Field conversion between natural gas and propane uses Kingsman kits 450DV-CKNG / -CKLP (millivolt) and -CKNGI / -CKNG2 / -CKLPI / -CKLP2 (IPI), installed by a qualified agency (pp.41–43).
- Have the burner, pilot and venting inspected every year by a qualified technician.
Controls and ignition (pp.24–25, 36–37, 45–59)
- Millivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in a power outage; fans and lights do not run on battery (pp.24–25, 36–37, 45–59).
- IPI models offer an intermittent pilot mode and a cold-climate standing-pilot mode that keeps the firebox and vent warm in very cold weather.
- Proflame 2 systems shut off after 24 hours without a signal from the remote; the optional WMBH wall battery holder must be within 16 ft of the valve (12 ft recommended).
Venting (pp.60–70)
- Venting: Direct vent, 4"/7" flue collar. Rigid DuraVent DirectVent Pro 4" x 6-5/8" pipe with the Kingsman ZDVDKA stove adapter (horizontal or vertical termination); optional 4" B-vent with F35BVC.
- Minimum vertical 4-1/2 ft (stove 2-1/2" from the wall); maximum vertical 45 ft; maximum horizontal 20 ft with one 90° elbow and 7 ft of vertical; 1/4" rise per 12" of run.
- Each extra 90° elbow takes 36" off the horizontal run and each 45° takes 18"; propane horizontal runs need 1 ft more vertical rise.
- B-vent conversion with F35BVC into an existing 4" B-vent or lined chimney, 12–60 ft.
First fire and everyday use
- Break-in: fire the unit four times for 10 minutes with 5-minute cool-downs, then run it at least four hours at a time with the fan off until the paint-curing odour is gone (up to about 40 hours). Ventilate the room and keep babies, children, pregnant women and pets out while it cures (p.5).
- After turning it off, wait at least 60 seconds before relighting (p.5).
- The glass and front get very hot. Keep children, pets, furniture and drapes away, and use the safety screen or a gate for toddlers and at-risk people (p.6).
- Never burn wood or paper, never run it with the glass removed, cracked or broken, and do not use it if any part has been under water (p.6).
- Install carbon-monoxide detectors on every level and near bedrooms (p.7).
Building code information
- Install to local codes; where none exist, follow the current National Fuel Gas Code, ANSI Z223.1/NFPA 54, or in Canada CSA B149.1 (p.6).
- Electrical work: National Electrical Code, ANSI/NFPA 70, or in Canada CSA C22.1 Canadian Electrical Code (p.6).
- Manufactured homes: Manufactured Home Construction and Safety Standard, 24 CFR Part 3280 and ANSI/NFPA 501A; in Canada CAN/CSA Z240 MH (p.8).
- Carbon-monoxide detectors (Massachusetts and recommended practice): NFPA 720 and ANSI/UL 2034 (p.7).
- Massachusetts installations follow the Massachusetts fuel gas code (248 CMR) and 527 CMR (p.7).
Warranty
- Coverage is the Kingsman Limited Lifetime Warranty printed in the installation and operating manual (FDV451 installation and operating manual (451-MAN19), p.76).
- Basic one-year warranty: any component found defective is covered, parts and labour, for the first year after installation. Repairs need Kingsman's prior approval and must be done by an authorized Kingsman dealer.
- Limited lifetime: the heat exchanger, combustion chamber and burner are covered for as long as the original owner owns the appliance. The defective part is exchanged through the distributor; labour, materials, freight and handling are not covered after the first year.
- Not covered by the one-year warranty: accent light bulbs, gasketing, glass fronts and paint.
- Who is covered: the original owner, for a unit that stays at its original installation site in the continental U.S., Alaska, Hawaii or Canada. The unit must be installed and operated following the manual and local codes.
- Proof of installation date: keep your original installation records. Without them, coverage starts 30 days after the date of manufacture.
- How to claim: contact the dealer or contractor who installed the unit, with the model and serial numbers ready.
- Key exclusions: accident, abuse, negligence, misuse, fire, flood or acts of God; corrosive atmospheres; unauthorized alteration; lack of maintenance; faulty installation; installation or removal costs; service parts and supplies; electricity or fuel costs; incidental or consequential damages. Implied warranties last one year after the original installation.
California Proposition 65
WARNING: This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Flames and flame colors on the website may appear differently in real life.
Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
Frequently asked questions — FDV451
What do I need to order to complete the FDV451?
Kingsman lists the door front, side doors and log set as required for each unit: the F450FBL charcoal door front (with safety screen and vent lid), F451SDSBL side doors, and the LOGF451 log set (or bronze glass media in its place). You also need the venting, or the F35BVC B-vent converter, and a 3/8" NPT gas supply.
Does the FDV451 need framing or a hearth?
No framing is needed; it is a freestanding stove. Clearances are 36" in front, 15-1/2" at the sides and 2-1/2" at the back, with the ceiling at least 71-1/2" above the floor. In an alcove the space must be 48" deep, 71-1/2" high and 58" wide. It can sit directly on carpet, tile or other combustible flooring; a hearth is recommended over vinyl.
What venting does it use, and how far can it run?
It is direct vent from a 4"/7" collar to an FDVHSQ or FDVHT horizontal, Z47ST24 / Z47ST36 snorkel, or FDVVT40 / Z47VT vertical termination. The vertical rise can be up to 45 ft, and the horizontal run up to 20 ft with one 90° elbow and 7 ft of vertical; the shortest setup is 4-1/2 ft vertical with the stove 2-1/2" from the wall. Each extra 90° elbow takes 36" off the horizontal run.
Can it vent into an existing chimney or B-vent?
Yes, with the F35BVC B-vent converter, installed vertically: 12 ft minimum to 60 ft maximum, with at least 57-1/4" to the top of the elbow. A masonry clay-lined chimney needs a liner if it is wider than 5" inside, and a wood-burning or B-vent chimney if wider than 6". The chimney must not vent any other appliance, and only the direct vent version is mobile home approved.
Can the FDV451 be converted between natural gas and propane?
Yes, with Kingsman kits 450DV-CKNG / -CKLP (millivolt) or -CKNGI / -CKNG2 / -CKLPI / -CKLP2 (IPI), installed by a qualified agency. Input is 34,500 / 23,750 BTU/h on natural gas and 31,000 / 24,500 BTU/h on propane (max/min).
Does it work in a power outage?
Yes. Millivolt models need no electricity. IPI models run on a 120 VAC adapter with a battery backup that keeps the fire working in an outage; the optional fan does not run on battery.