Hestan 54" Outdoor Canopy Vent Hood GVP54
SKU / Model: GVP54
Grill only$7,399.00
Unlock an exclusive offer on this product.
The Hestan GVP54 is a 54-inch Pro Canopy outdoor vent hood: a wall-mounted canopy that pulls smoke, heat and grease away from a 42-inch grill in a covered outdoor kitchen. Hestan recommends the GVP54 for 42" grills, and the hood must sit under a protective roof that keeps water out.
It moves 1,200 CFM (Hestan rates it equivalent to 1,800 CFM) through two WM2L dual blowers. Grease is captured in the blower housings and shields rather than in baffle filters, and both lift out for cleaning and can go in the dishwasher. Two blower speed knobs let you start low and add speed or blowers as the cooking demands, and a separate knob dims or switches off the LED lights.
The canopy comes in stainless steel or one of Hestan's signature colors (Bora Bora, Citra, Froth, Grove, Lush, Matador, Pacific Fog, Prince, Sol, Stealth and Tin Roof), with matching duct covers in three heights. It runs on a dedicated 120V, 20 A GFCI-protected circuit and vents outside through smooth galvanized metal duct, which suits a covered patio or pavilion kitchen built around a Hestan grill.
Key features
- 1,200 CFM at 0.0" static pressure (equivalent to 1,800 CFM)
- Blower package: two WM2L dual blowers
- Baffle-less design: grease is captured in removable blower housings and shields
- Blower housings and shields are dishwasher safe
- Two blower speed knobs plus a separate dimmable LED light knob
- Color-coded (black and white) blower motors and wheels for correct reassembly
- 6.6 sones at the highest speed
- Sized for 42" grills
- Suitable for covered outdoor use on a GFCI-protected circuit
- Stainless steel or 11 Hestan colors, with matching duct covers
Specifications
| Model | GVP54 (stainless) / GVP54-XX (Hestan color: -TQ, -OR, -WH, -GR, -PP, -RD, -GG, -BU, -YW, -BK, -BG) |
|---|---|
| Brand | Hestan |
| Type | 54" wall-mounted outdoor Pro Canopy vent hood |
| Unit dimensions | 54" W; depth and height are not published by the manufacturer as text figures |
| Framing dimensions | None required (wall-mounted canopy): the hood hangs on its wood mounting strip, fastened to at least three studs, on a non-combustible wall under a protective roof |
| Viewing area | Not applicable |
| Clearances to combustibles | Bottom edge of the hood 30" above the cooking surface (recommended); at least 24" to combustible vertical surfaces on each side; the wall behind the hood and grill and everything within that 24" zone must be non-combustible (e.g. metal studs with cement board, stucco or stone); at least 5" behind the grill so the grill hood can open; never on or next to unprotected combustible construction; the grill's own clearances also apply |
| Recommended grill width | 42" |
| Airflow | 1,200 CFM at 0.0" SP (equivalent 1,800 CFM); 1,062 / 960 / 860 CFM at 0.1" / 0.2" / 0.3" static pressure |
| Sound level | 6.6 sones at the highest speed |
| Duct connection | Two 8" round outlets; the optional AKVT8812 transition combines them into 12"; 12" transition sits 16-1/2" above the hood top |
| Electrical | 120V AC, 60 Hz, single phase, 7.5 A; dedicated 20 A GFCI-protected, grounded circuit; wired by a licensed electrician |
| Lighting | LED, dimmable (replacement Hestan P/N 025075) |
| Use | Covered outdoor applications only, under a protective roof |
Included components
- Wood mounting strip (recessed in the mounting channel)
- Removable, dishwasher-safe blower housings and shields
- LED lights with dimmer knob
Required components
- Dedicated 120V, 20 A GFCI-protected, grounded circuit
- One 1/2" UL-listed wire clamp per motor box and UL-listed wire nuts
- Smooth galvanized metal duct and foil HVAC tape (no flexible or corrugated duct, no cloth duct tape)
- A wall louver or roof cap with a gravity damper on each duct run (Hestan AKVWL8 / AKVWL12 wall louvers or AKVRC8HP / AKVRC12HP low-profile roof caps)
- Back venting only: two 8" elbows
- Protective roof over the hood
Optional accessories
- Hestan duct cover KVDC5412 (12" high), KVDC5424 (24" high) or KVDC5436 (36" high); color versions add -XX
- Hestan multi-blower transition AKVT8812 (8" and 8" to 12")
- Hestan low-profile elbow AKVBE8 (8" round to 6" x 8-1/2" rectangular)
- Hestan low-profile roof caps AKVRC8HP, AKVRC12HP (roof pitch 4/12 minimum)
- Hestan wall louvers AKVWL8, AKVWL12
Installation & safety
⚠ Important: The hood is for covered outdoor use only, on a GFCI-protected circuit, and must never be mounted on or next to unprotected combustible construction. Run it whenever the grill is on, never use it to exhaust hazardous or explosive materials, and lock out power at the service panel before cleaning or service.
Regulatory and code requirements
- Install to local codes or, without them, the National Electrical Code; ground to local codes, the NEC ANSI/NFPA 70 or the Canadian Electrical Code CSA C22.1.
- 120V AC, single phase, 60 Hz on a dedicated 20 A GFCI-protected circuit (7.5 A rating), wired by a licensed electrician. Never use a solid-state speed control with this blower.
Ducting do's and don'ts
- Use smooth galvanized metal duct only and keep runs short and straight with gradual turns; a 90° elbow counts as 5 ft of duct. Never reduce the duct size, and on runs over 20 ft increase the diameter 1" for every 10 ft.
- Each run ends in a wall louver or roof cap with a gravity damper (no screen wire or spring-loaded doors). Never vent into an attic or a chimney.
Installation
- Lift with at least two people (three for larger hoods or duct covers). Set the bottom edge about 30" above the cooking surface, with 24" to combustible vertical surfaces at each side and a non-combustible wall behind.
- Remove the blower shields and housings and one motor per assembly, fit a 1/2" UL-listed clamp in each motor box and bring the supply wiring to the hood.
- Mark a level line and centerline, then fasten the wood mounting strip to at least three studs. For back venting, cut the wall opening and fit two 8" elbows.
- Drill 3/32" pilot holes in the strip, hang and secure the hood, fit any transition and seal the joints with foil HVAC tape. Fix any duct cover to at least one stud.
- Connect neutral to white, hot to black and ground to green with UL-listed wire nuts, refit the motors, housings and shields (matching the color-coded motors and wheels), check the dampers move freely, then restore power and test every blower and light setting.
Using, cleaning and maintenance
- Start on the lowest setting and raise the speed or add blowers as needed.
- Check the grease tray over the first six months to a year to set a cleaning schedule. Soak the blower housings and shields in warm soapy water or put them in the dishwasher; clean the blower wheel with a soft brush and degreaser, keeping its balancing clips in place; wipe the canopy with warm soapy water and polish stainless with the grain.
Warranty
Hestan limited warranty (vent hood manual), non-commercial use, products bought from an authorized dealer, 50 US states, D.C. and Canada:
- Defects in materials or workmanship: 2 years from delivery or the retail purchase date (or the new-construction closing date, whichever is later)
- Blower motors and electronic control boards: 5 years for the original purchaser, replacement parts only (labor, shipping and handling paid by the purchaser); surface corrosion, scratches and discoloration excluded
Downloads
Follow the manufacturer's installation instructions exactly. Improper installation, adjustment, alteration or maintenance can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.
California Proposition 65
WARNING: This product can expose you to chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Frequently asked questions — GVP54
What size grill is it for?
Hestan recommends the GVP54 for a 42" grill.
How high above the grill does it mount?
Hestan recommends the bottom edge of the hood 30" above the cooking surface, with at least 24" to combustible vertical surfaces on each side and a non-combustible wall behind.
Can it go under an open sky?
No. It is for covered outdoor applications and must be under a protective roof that keeps water out.
What ducting does it need?
Smooth galvanized metal duct (two 8" round outlets; the optional AKVT8812 transition combines them into 12"), ending in a wall louver or roof cap with a gravity damper. Never vent into an attic or a chimney.
What power does it need?
A dedicated 120V, 20 A GFCI-protected, grounded circuit, wired by a licensed electrician; the hood draws 7.5 A.
What's the warranty?
2 years on defects in materials or workmanship, and 5 years on the blower motors and electronic control boards (replacement parts only).
Loading component details…