Buck Stove CR18 Vent-Free Ceramic Gas Log Set GL CR18

SKU / Model: GL CR18MVLP

Free Fast Shipping
In-stock items are processed in 1–2 business days.

$812.00

Early Black Friday Savings applied in your cart

YOUR SPECIAL OFFER IS AVAILABLE

This product qualifies for an exclusive special offer.

Complete your selections and add this product to your cart to unlock the eligible offer.

Offer eligibility and final promotional pricing are confirmed in the cart. Accessories qualify separately. Offers may change.

Product overview

The Buck Stove CR18 is a 18" vent-free ceramic gas log set that turns an existing wood-burning fireplace into a clean, efficient gas fire in an afternoon. Four realistic ceramic logs sit on Buck's vent-free burner.

It fits smaller fireplace openings where a 24" set will not, with the same Buck burner and controls as the larger CR sets.

Rated up to 30,000 BTU/hr (23,000 minimum), it puts nearly all of its heat into the room, about 99% efficient, with no chimney needed in vent-free mode. Choose a millivolt valve (remote and wall-thermostat ready) or a modulating thermostatic valve (not remote compatible). Piezo ignition lights the ODS safety pilot, and the burner needs no electricity, so it keeps heating through outages.

Natural gas or propane (order the fuel you have). Approved for aftermarket manufactured homes. Add the MA 19HS heat shield with blower to push more heat into the room. Made by Buck Stove.

Key features

  • 18" ceramic log set with burner.
  • Up to 30,000 BTU/hr (23,000 min).
  • About 99% efficient vent-free (Buck).
  • Choose a millivolt valve (remote and wall-thermostat ready) or a modulating thermostatic valve (not remote compatible).
  • Piezo ignition and ODS pilot.
  • Hi-to-Lo flame control (Buck).
  • Millivolt versions are remote and wall-thermostat compatible.
  • Optional 19HS heat shield with blower.
  • Works without electricity.
  • Natural gas or propane (not field convertible).
  • Aftermarket manufactured-home approved.
  • Certified to ANSI Z21.11.2 and ANSI Z21.60/CSA 2.26 (vent-free or vented decorative use).

Specifications

SKUs GL CR18MVNAT, GL CR18MVLP, GL CR18MODNAT, GL CR18MODLP
Input 23,000-30,000 BTU/hr
Minimum fireplace 17" H x 25" W front x 18" W rear x 14" D
Minimum with 19HS heat shield 20" H x 25" W front x 23" W rear x 19-1/2" D
Gas pressures NG inlet 4.5-10.5" W.C., manifold 3.5"; LP inlet 10.5-13.0" W.C., manifold 10.0"
Gas connection 3/8" NPT, right side
Side wall clearance 8"
Ceiling clearance 42" from top of the fireplace opening
Efficiency About 99% (Buck)
Certification ANSI Z21.11.2; ANSI Z21.60/CSA 2.26

What's included

  • 18" ceramic log set
  • Vent-free burner with valve and ODS pilot

Required (sold separately)

  • A solid-fuel masonry fireplace, a UL 127 factory-built fireplace that allows vent-free logs, or a listed ventless firebox (e.g. Buck ZCBB)
  • Gas supply line with shutoff valve
  • Propane: external regulator limiting tank pressure to 13" W.C.
  • Fireplace screen in place during operation; glass doors fully open

Optional

  • PO FDC504-S SkyTech thermostatic remote, dark gray (millivolt)
  • PO FDC504-A Acumen thermostatic remote, black (millivolt)
  • PO 4001-A-NBS SkyTech on/off remote, white (millivolt)
  • PE 400142 white wall thermostat (millivolt)
  • MA 19HS heat shield with blower (120V)
  • MAPSFPC canopy (required with some mantel heights; see manual)

Warranty

  • Two years from first purchase on materials and components, original purchaser, parts only.
  • Implied warranties limited to one year; liability limited to purchase price.
  • Not covered: labor, removal/reinstallation, transportation, service calls, painted surfaces, improper installation.
  • Mail the registration within 30 days of installation with dealer and installer numbers.
  • Source: CR/DX 18-24-30 and Mountaineer gas log manual (October 2023), warranty page.

Downloads

Installation and safety

⚠ Important: Improper installation, adjustment, alteration, service or maintenance can cause fire, explosion, property damage, injury or carbon-monoxide poisoning. This vent-free gas appliance must be installed and serviced by a qualified professional following the manufacturer's manual and your local codes. If you ever smell gas, do not light anything or touch electrical switches; leave and call your gas supplier.

Safety information

  • Not for bedrooms or bathrooms (over 10,000 BTU/hr), recreational vehicles, or drafty, high-traffic areas.
  • Never burn wood in the fireplace afterwards; do not place objects on the logs.
  • Keep curtains and furniture at least 42" from the front; keep fans from blowing into the fireplace.

Fireplace types and preparation

  • Masonry, UL 127 factory-built (if its manual allows vent-free logs) or listed ventless firebox; clean the chimney and firebox first.
  • Minimum opening: 17" H x 25" W front x 18" W rear x 14" D.
  • Permanently close outside air ducts and ash dumps.

Clearances

  • 8" from the sides of the opening to combustible walls; 42" from the top of the opening to the ceiling; nothing within 24" of the opening.
  • Mantel height depends on mantel depth (manual Figure 1); a MAPSFPC canopy is required unless a 10" mantel is 36" above the opening.
  • Carpet or tile floors need a full-width metal or wood panel.

Gas connection and pressures

  • 3/8" NPT on the right; natural gas needs internally tinned copper tubing; leak-test with soap solution.

Log placement and operation

  • Place each log and the embers exactly per the manual; wear gloves (bonded ceramic fiber).
  • Run the burner fully on or fully off; do not use the shutoff to adjust heat.

Heat shield 19HS

  • Optional 19HS blower runs on 120V/60Hz, 0.54 A; check the larger minimum fireplace size.

Room size and fresh air (manual Combustion and ventilation air section)

  • The room must be an unconfined space: at least 50 cubic feet per 1,000 BTU/hr of all gas appliances in the space (some areas require 70).
  • Example from the manual: a 20 x 16 x 8 ft room (2,560 cu. ft.) supports up to 51,200 BTU/hr.
  • In tighter spaces, add two permanent openings to an adjoining room or outdoors (one within 12" of the ceiling, one within 12" of the floor, each at least 1 sq. in. per 1,000 BTU/hr and 100 sq. in. minimum).
  • Vent-free heaters add moisture to the room; poor ventilation can cause mildew.

Vented use and manufactured homes

  • For vented use, the damper must be fixed open to the minimum flue area in the manual chart.
  • Aftermarket, permanently located manufactured homes allowed where local codes permit.

Building code information

Install and operate this appliance exactly as the manufacturer's instructions and local codes require. Improper installation, adjustment or maintenance can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.

Flames and flame colors on the website may appear differently in real life.

California Proposition 65

WARNING: This product can expose you to chemicals including carbon monoxide and benzene, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov.

Loading component details…

Add to cart to see your price.

Call for best price