Barbara Jean 36" Linear Outdoor Burner System OB36

SKU / Model: OB36MAPT

Free Fast Shipping
In-stock items are processed in 1–2 business days.

$834.75

Early Black Friday Savings applied in your cart

YOUR SPECIAL OFFER IS AVAILABLE

This product qualifies for an exclusive special offer.

Complete your selections and add this product to your cart to unlock the eligible offer.

Offer eligibility and final promotional pricing are confirmed in the cart. Accessories qualify separately. Offers may change.

Product overview

The Barbara Jean OB36 is a 36-inch linear outdoor gas burner system, a complete certified and listed burner that you build into your own non-combustible enclosure: a custom fire table, a planter-style fire feature, a bar-height counter or a masonry surround. The burner tray measures 38 in. long by 7-1/2 in. wide and drops into a 36-1/2 in. by 5-3/4 in. opening, and burners can be linked in series for longer runs.

This listing is offered with a propane manual valve with thermocouple and push-button igniter (OB36MAPT), a natural gas millivolt valve (OB36MVN), or a natural gas IPI Proflame 2 system with remote control (OB36IPN). Rated up to 60,000 BTU/h, it throws a long, even ribbon of flame through Barbara Jean ember glass in five colors, or through driftwood, rock sets, stones or cannonballs, with HI/LO flame adjustment.

The burner is Satin Coat steel with a high-temperature black paint finish over a zinc pretreatment for corrosion resistance. Certified for the USA and Canada as an outdoor decorative gas appliance and crafted in Canada, it suits builders and do-it-yourselfers who want a custom outdoor fire feature with a factory-listed burner.

Key features

  • Linear burner: 36-inch burner, tray 38 in. L x 7-1/2 in. W, up to 60,000 BTU/h.
  • Complete listed system: Burner, valve, pilot and igniter are certified together to ANSI Z21.97-2017 / CSA 2.41-2017 for the USA and Canada.
  • Valve choices: OB36MAPT propane manual valve; OB36MVN natural gas millivolt; OB36IPN natural gas IPI Proflame 2.
  • IPI Proflame 2: Remote on/off, flame control and LED accent lighting control; the remote runs on 3 AAA batteries.
  • HI/LO adjustment: Every valve system offers high and low flame settings.
  • Links in series: Burners can be joined end to end (for example OB36 and OB48) for longer flame runs.
  • Built for outdoors: Satin Coat steel, zinc pretreated, high-temperature black paint.
  • Media choices: Five ember glass colors plus driftwood logs, rock sets, stones and cannonballs.
  • Glass wind guard option: OB36WG 4-piece tempered glass guard, 5-1/2 in. high; cuts side clearance to 12 in.
  • No power needed (millivolt): The millivolt valve generates its own power: piezo igniter and on/off rocker switch, no outlet.

Specifications

Model / MPN OB36MAPT, OB36MVN, OB36IPN
Brand Barbara Jean Collection (Kingsman)
Type Linear outdoor gas burner system, 36 in., for custom non-combustible enclosures
Unit dimensions Burner tray 38 in. L x 7-1/2 in. W (brochure B0504 and manual p.8, dimensions A x B; allow 1/8 in. per side)
Framing dimensions Opening in the enclosure top 36-1/2 in. x 5-3/4 in. (manual pp.17, 20; linked burners: add the lengths plus 1/2 in.); non-combustible enclosure with at least 53 sq in of air openings; OBUVM2 valve box opening 17 in. W x 8-1/4 in. H, at least 3 in. from the burner tray
Viewing area 36-inch linear flame along the 38 in. burner tray
Clearances to combustibles Sides of burner tray 24 in.; ends 12 in.; top of tray to ceiling 49-1/2 in.; top of tray at least 8 in. above the floor; 12 in. with a wind guard in place; valve, switch and remote receiver at least 5 in. below the top of the tray (0 in. with the OBUVM2 valve box) (manual pp.6, 8)
Gas input OB36MAPT: propane 22,000 low / 60,000 high BTU/h (#40 orifice); natural gas with the included orifice 13,000 low / 58,500 high BTU/h (#15)
OB36MVN: natural gas 39,000 low / 60,000 high BTU/h (#25 orifice); propane by kit 48,000 low / 60,000 high BTU/h (#43)
OB36IPN: natural gas 39,000 low / 60,000 high BTU/h (#25 orifice); propane by kit 48,000 low / 60,000 high BTU/h (#43)
Ignition MAPT: manual valve with thermocouple, push-button igniter (one AAA battery, not included); MVN: millivolt valve, piezo igniter, on/off rocker switch on the valve; IPN: IPI Proflame 2 intermittent pilot with remote control
Venting None: outdoor decorative appliance for open-air use only
Gas inlet 3/8 in. NPT
Supply pressure Manual valve: natural gas 7 in. w.c.; propane 10 in. w.c.
Millivolt / IPI: natural gas 5.5 in. min, 7 in. normal, 10 in. max (manifold 1.6 in. low, 3.5 in. high); propane 11 in. min and normal, 13 in. max (manifold 6.3 in. low, 10 in. high)
Electrical IPN: AC power to the Proflame 2 IFC module through the supplied power cord harness, grounded three-prong plug into an outdoor GFI-protected outlet; no battery backup is available. MAPT and MVN: none
Glass media 4 bags x 5 lb (20 lb; 5 lb per foot of burner), no more than 1 in. above the burner tray
Altitude Orifices rated 0-4,500 ft; above 4,500 ft derate 4% per 1,000 ft
Certification ANSI Z21.97-2017 / CSA 2.41-2017 outdoor decorative gas appliance (USA and Canada)

Included components

  • 36-inch linear burner tray with pilot assembly and pilot shield
  • OB36MAPT: manual valve with regulator and 10 ft hose, thermocouple, push-button igniter with wire and sparker, brass orifice for natural gas conversion (manual p.10)
  • OB36MVN: millivolt valve system with orifice and pilot assembly, piezo igniter with wire and sparker, on/off rocker switch installed on the valve (manual p.13)
  • OB36IPN: IPI Proflame 2 valve, IFC module, power cord harness and remote control, with LED lights (manual p.50)
  • Installation and operating manual 24OB-MAN17

Required components

  • Ember glass or other Barbara Jean media: 4 bags of 5 lb (20 lb)
  • Non-combustible enclosure with a 36-1/2 in. x 5-3/4 in. burner opening, at least 53 sq in of air openings and drainage
  • Gas supply: natural gas line, or a propane cylinder built to DOT or CAN/CSA-B339 with an overfilling prevention device
  • One AAA battery for the MAPT push-button igniter (not included)
  • Outdoor GFI-protected electrical outlet for the IPN Proflame 2 module, and 3 AAA batteries for the remote
  • To run a natural gas burner on propane: LP conversion kit 36OB-CKLP (millivolt) or 36OB-CKLP2 (IPI)

Optional accessories

  • Ember glass, 5 lb bags: MQG5ZG zircon glacier ice, MQG5A cobalt blue, MQG5B black, MQG5C bronze, MQG5W white
  • OB36WG glass wind guard, 4 pieces, 5-1/2 in. high
  • 36LT-LID burner lid
  • OFP42SA spark assist for the millivolt valve (one AA battery, not included)
  • OBUVM2 universal valve box (millivolt and IPI)
  • 27FP-900FF propane regulator with 5 ft hose; 24OFS-P120 regulator with 10 ft hose
  • MQRBD3 driftwood log set, 5 pieces
  • MQRBD4 driftwood log set, 3 pieces
  • MQROCK2 contemporary rock set
  • MQSTONE decorative stones
  • MQSTONE10 decorative stones, 10 pieces
  • RBCB1 cannonballs, 14 pieces

Product video

Installation and safety notes

⚠ Important: This is an outdoor gas appliance. Improper installation, adjustment or use can cause fire, explosion or carbon-monoxide exposure. Follow manual 24OB-MAN17 exactly, keep children and pets away from hot surfaces, and use it outdoors only.

Warnings & gas line installation

  • For outdoor use only; not for use in temperatures below freezing (pp.2, 5).
  • Natural gas needs at least 3/8 in. iron pipe from the meter and at least 4.5 in. w.c.; connect through the left-side or bottom knockout with a union for service (p.5).
  • Leak-test every joint with soap solution, never an open flame (p.5).

Locating your appliance & clearances

  • Allowed: walls on all sides with no overhead cover (96 sq ft minimum and a permanent ground-level opening); an overhead cover with no more than two side walls; or three side walls with at least 30% of the perimeter permanently open (p.6).
  • Screened porch: at least 96 sq ft with two sides fully open, or screened walls with at least 64 sq ft of screen and 78 in. wall height (p.6).
  • Clearances: 24 in. from the sides and 12 in. from the ends of the burner tray, 49-1/2 in. to a ceiling, tray top at least 8 in. above the floor; 12 in. with a wind guard (p.6).

Burner systems for custom applications

  • Burners may be connected in series; only one ON/OFF device may be used on the appliance (p.8).
  • Valve, ON/OFF switch and remote receiver must sit at least 5 in. below the top of the burner, or 0 in. inside the OBUVM2 valve box (pp.6, 8).
  • Manual valve control panel cutout: 2-7/16 in. high x 7-1/2 in. wide, within 12 in. of the burner orifice bracket (p.11).
  • Stock burner opening 36-1/2 in. x 5-3/4 in.; enclosure non-combustible with at least 53 sq in of air openings; gas controls supported, accessible and readily removable; do not insulate around the burner; provide drainage (pp.2, 6, 17, 20).
  • OBUVM2 universal valve box: opening 17 in. W x 8-1/4 in. H, at least 3 in. from the burner tray (p.19).

Enclosures for LP gas supply

  • Upper vents 1 sq in per lb of stored fuel and floor vents 1/2 sq in per lb; the cylinder floor sits at least 2 in. above the ground (p.21).

Glass media, burner lids & wind guards

  • Use 4 bags (20 lb) of Barbara Jean glass, no more than 1 in. above the burner tray; never cover the pilot (pp.17, 24).
  • Burner lid 36LT-LID sits 1 in. above the burner and extends 3/4 in. past the ends; turn the pilot knob OFF before fitting it (p.26).
  • Wind guards are recommended on outdoor burners and assemble from tempered glass panels and corner brackets (pp.27-28).

Maintenance

  • Keep the burner, pilot and media clean and dry; inadequate drainage causes rust, which the warranty does not cover (pp.2, 29-30).

Lighting, gas specifications & conversion

  • Manual valve: the push-button igniter lights the pilot; the manual valve with thermocouple sets the flame HI or LO (pp.10, 31).
  • Millivolt: the piezo igniter lights the pilot and the on/off rocker switch turns the burner on and off; the millivolt generator should read at least 325 mV (pp.32, 42).
  • IPI Proflame 2: with electric power on, the ON/OFF key on the remote lights the burner through automatic pilot ignition (p.34).
  • MAPT ships for propane; to convert to natural gas, fit the supplied #15 orifice, set the air shutter to 1/16 in. open and remove the LP hose and regulator (pp.35-36).
  • Natural gas millivolt and IPI burners convert to propane with the 36OB-CKLP or 36OB-CKLP2 kit; propane air shutter fully open (pp.35-38).

IPI Proflame 2 & LED lighting

  • Connect the grounded three-prong plug to an external GFI-protected outlet near the burner (pp.43, 46).
  • The remote uses 3 AAA batteries; the OPTION button selects LIGHT, AUX or FLAME control, and the LED kit cycles colour modes 0-22 (pp.45, 47).

Building code information

  • Gas: local codes or, where none apply, the National Fuel Gas Code, ANSI Z223.1/NFPA 54 in the USA, or CSA B149.1 (Natural Gas and Propane Installation Code) in Canada
  • Propane storage and cylinders: CSA B149.2 (Propane Storage and Handling Code); cylinders built to U.S. DOT specifications or CAN/CSA-B339
  • Electrical (IPI models): National Electrical Code, ANSI/NFPA 70 in the USA, or CSA C22.1 (Canadian Electrical Code)
  • Certification standard: ANSI Z21.97 / CSA 2.41 (outdoor decorative gas appliances)

Warranty

  • Barbara Jean Collection limited warranty, manual 24OB-MAN17 p.52.
  • Burner: 5 years.
  • Gas valves, thermocouples, igniters, lights and media: 1 year.
  • Coverage area: continental USA, Alaska, Hawaii and Canada, only at the original installation site, when installed and operated per the instructions; without proof of installation the start date is the manufacture date plus 30 days.
  • Not covered: scratches, dents, painted finishes, heat discoloring, corrosion, damage from abrasive or chemical cleaners, chipped porcelain or powder-coated parts, labor and freight.

Downloads

California Proposition 65

WARNING: This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

Flames and flame colors on the website may appear differently in real life.

Please follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.

Frequently asked questions — OB36

What size opening does the OB36 need?

Cut a 36-1/2 in. by 5-3/4 in. opening in a non-combustible enclosure top for the 38 in. by 7-1/2 in. burner tray, and give the enclosure at least 53 sq in of air openings.

Which gas does it use?

OB36MAPT ships for propane with a natural gas orifice included. OB36MVN and IPN are natural gas and convert to propane with the 36OB-CKLP or 36OB-CKLP2 kit.

Does it work in a power outage?

The manual valve and millivolt versions need no electricity. The IPI Proflame 2 version needs AC power to its module, and Barbara Jean offers no battery backup for it.

How much glass media do I need?

4 bags of 5 lb (20 lb), no more than 1 in. above the burner tray.

What clearances does it need?

24 in. from the sides and 12 in. from the ends of the burner tray, 49-1/2 in. to a ceiling, and 12 in. with a wind guard in place.

What's the warranty?

The burner is warranted for 5 years; gas valves, thermocouples, igniters, lights and media for 1 year.

Loading component details…

Add to cart to see your price.

Call for best price