{"product_id":"osburn-matrix-2700-wood-insert-ob02700","title":"Osburn Matrix 2700 Wood Insert OB02700","description":"\u003ch3\u003eOverview\u003cbr\u003e \u003c\/h3\u003e\n\u003cp\u003eOsburn Matrix 2700 Wood Insert OB02700 - Inspired by nature, the Matrix 2700 insert is a fusion of traditional style and technological innovation. Located in the heart of your living space, the generous viewing area of the Matrix 2700 will invite you to sit back, relax and take in the calm and warmth of its flames. Eco-savvy consumers will appreciate its efficient combustion, quality performance and classic beauty.\u003c\/p\u003e\n\u003cp\u003eThis unit comes standard with cast iron faceplate and heat activated blower. Customize the look of this non-catalytic appliance by choosing from a black or brushed silver-plated door overlay and fire screen.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eAPPLIANCE PERFORMANCE (\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/matrix-2700-wood-insert\/#note-order-1\"\u003e1\u003c\/a\u003e)\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel type :\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended heating area-ft² : ()\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e750 - 2,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall firebox volume-ft³ :\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA loading volume-ft³ :\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum burn time : ()\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum heat output-dry cordwood : (\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/matrix-2700-wood-insert\/#note-order-3\"\u003e2\u003c\/a\u003e)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e80,000 BTU\/h (23.4 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall heat output rate \u0026lt; : (\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/matrix-2700-wood-insert\/#note-order-3\"\u003e2\u003c\/a\u003e) (\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/matrix-2700-wood-insert\/#note-order-4\"\u003e3\u003c\/a\u003e)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12,700 BTU\/h (3.72 kW) to 60,700 BTU\/h (17.79 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage overall efficiency (dry cordwood) : (\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/matrix-2700-wood-insert\/#note-order-4\"\u003e3\u003c\/a\u003e)\u003c\/td\u003e\n\u003ctd\u003e64 % (HHV) (\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/matrix-2700-wood-insert\/#note-order-5\"\u003e4\u003c\/a\u003e)\u003c\/td\u003e\n\u003ctd\u003e68 % (LHV) (\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/matrix-2700-wood-insert\/#note-order-6\"\u003e5\u003c\/a\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum overall efficiency : (\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/matrix-2700-wood-insert\/#note-order-7\"\u003e6\u003c\/a\u003e) (\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/matrix-2700-wood-insert\/#note-order-8\"\u003e7\u003c\/a\u003e)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e70 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum heat transfer efficiency : (\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/matrix-2700-wood-insert\/#note-order-9\"\u003e8\u003c\/a\u003e)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e68 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage particulate emissions rate : (\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/matrix-2700-wood-insert\/#note-order-10\"\u003e9\u003c\/a\u003e)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.2 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage CO : (\u003ca href=\"https:\/\/www.osburn-mfg.com\/en\/products\/wood-inserts\/matrix-2700-wood-insert\/#note-order-11\"\u003e10\u003c\/a\u003e)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e98 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e(\u003cstrong\u003e1\u003c\/strong\u003e) Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.\u003c\/p\u003e\n\u003cp\u003e() Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.\u003c\/p\u003e\n\u003cp\u003e(\u003cstrong\u003e2\u003c\/strong\u003e) The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb\/ft³ and 20 lb\/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb\/ft³ and 12 lb\/ft³. The moisture content is between 19% and 25%.\u003c\/p\u003e\n\u003cp\u003e(\u003cstrong\u003e3\u003c\/strong\u003e) As measured per CSA B415.1-10 stack loss method.\u003c\/p\u003e\n\u003cp\u003e(\u003cstrong\u003e4\u003c\/strong\u003e) Higher Heating Value of the fuel.\u003c\/p\u003e\n\u003cp\u003e(\u003cstrong\u003e5\u003c\/strong\u003e) Lower Heating Value of the fuel.\u003c\/p\u003e\n\u003cp\u003e(\u003cstrong\u003e6\u003c\/strong\u003e) Performances based on a fuel load prescribed by the standard at 7 lb\/ft³ and with a moisture content between 19% and 25%.\u003c\/p\u003e\n\u003cp\u003e(\u003cstrong\u003e7\u003c\/strong\u003e) Optimum overall efficiency at a specific burn rate (LHV).\u003c\/p\u003e\n\u003cp\u003e(\u003cstrong\u003e8\u003c\/strong\u003e) The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.\u003c\/p\u003e\n\u003cp\u003e(\u003cstrong\u003e9\u003c\/strong\u003e) This appliance is officially tested and certified by an independent agency.\u003c\/p\u003e\n\u003cp\u003e(\u003cstrong\u003e10\u003c\/strong\u003e) Carbon monoxyde.\u003c\/p\u003e\n\u003ch3\u003eGENERAL FEATURES\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustion technology\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-catalytic\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-efficiency certified appliance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes, EPA 2020 approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog positioning\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLoading over width\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlue outlet diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of chimney\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLiner - ULC-S635, CAN\/ULC-S640, UL1777\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum chimney height (feet)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15'\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaffle type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC-Cast or equivalent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproved for a mobile home installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNo\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e535 lb (243kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSingle, glass with cast iron frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCeramic glass\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass surface – dimensions (Width X Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24 3\/8\" X 12 5\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass air-wash system\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePremium quality blower included (CFM)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e176\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e30 1\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e43 5\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e27 1\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor opening – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 1\/2\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor opening - dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e25 3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12 3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox – dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e22 5\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox – dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoulded refractory bricks\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStainless-steel secondary-air system improving gas combustion\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustable threaded legs\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteel thickness – body\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/16''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteel thickness – top\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/16''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFireplace opening – minimum (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e27 1\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFireplace opening – minimum (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e31 3\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFireplace opening – minimum (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e22 1\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEPA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanadian Standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA B415.1-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 1482, UL 737\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanadian standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eULC S628\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTested and listed as per applicable standards\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBy an accredited laboratory (CAN\/USA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLimited lifetime\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eMinimum clearances to combustibles*\u003cbr\u003e\u003cem\u003e(Data expressed in inches. 1 inch = 25.4 mm)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd colspan=\"1\"\u003eCanada\u003c\/td\u003e\n\u003ctd colspan=\"1\"\u003eUnited-States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – top (measured from the platform on which the appliance is installed)**\u003c\/td\u003e\n\u003ctd\u003e84\"\u003c\/td\u003e\n\u003ctd\u003e84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible side mantle to unit\u003c\/td\u003e\n\u003ctd\u003e9 1\/2\"\u003c\/td\u003e\n\u003ctd\u003e9 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible top mantle to unit\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible side wall to unit\u003c\/td\u003e\n\u003ctd\u003e19\"\u003c\/td\u003e\n\u003ctd\u003e19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – minimum floor protection in front of the appliance\u003c\/td\u003e\n\u003ctd\u003e18\"\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance - from the top of the unit to the shelf\u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – from the top of the insert to the shelf\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and\/or web sites).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003e\u003ca style=\"color: #ff0000;\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7559\/45999a_2024-11-01.pdf\"\u003eOsburn Matrix 2700 wood insert install \u0026amp; owner's manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003e\u003ca style=\"color: #ff0000;\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/7559\/45999a_2024-11-01.pdf\"\u003e(PDF - 7.7 Mo)\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003e\u003ca style=\"color: #ff0000;\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5186\/ob02700-osburn-matrix-2700-encastrable.pdf\"\u003eOsburn Matrix 2700 dimensions\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003e\u003ca style=\"color: #ff0000;\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5186\/ob02700-osburn-matrix-2700-encastrable.pdf\"\u003e(PDF - 1.1 Mo)\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003e\u003ca style=\"color: #ff0000;\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/6948\/46122af_2023-05-30.pdf\"\u003eInstallation instructions | Cuttable faceplate | Projection kit\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003e\u003ca style=\"color: #ff0000;\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/6948\/46122af_2023-05-30.pdf\"\u003e(PDF - 1.1 Mo)\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003ePLANS \u0026amp; CAD\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003ca style=\"color: #ff0000;\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5264\/ob02700.dwg\"\u003e2D Diagrams\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003ca style=\"color: #ff0000;\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5264\/ob02700.dwg\"\u003e(DWG - 0.7 Mo)\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003ca style=\"color: #ff0000;\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5263\/ob02700.dxf\"\u003e2D Diagrams\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003ca style=\"color: #ff0000;\" href=\"https:\/\/sbiweb.blob.core.windows.net\/media\/5263\/ob02700.dxf\"\u003e(DXF - 2.6 Mo)\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Osburn Fireplaces","offers":[{"title":"Default Title","offer_id":50680723079330,"sku":"OB02700","price":4619.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Osburn-Matrix-2700-Wood-Insert-OB02700_491__27404.1785142193.1280.1280.jpg?v=1792461885","url":"https:\/\/unitedfireplaces.com\/products\/osburn-matrix-2700-wood-insert-ob02700","provider":"United Fireplaces","version":"1.0","type":"link"}