{"product_id":"napoleon-gds50-2","title":"Napoleon Havelock Elite Direct Vent Stove GDS50N-2","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Napoleon Havelock Elite (GDS50N-2) is a traditional cast-look direct vent gas stove rated up to 40,000 BTU\/h on natural gas. It suits large living rooms, great rooms, cottages and open-plan spaces, and it is approved for bedrooms, bathrooms and mobile homes. It vents through the top with 4\" \/ 7\" direct vent pipe, up to 20 ft horizontally or 40 ft vertically, or into an existing masonry chimney with a co-linear liner.\u003c\/p\u003e\u003cp\u003eThe look is classic Napoleon: square glass doors with a magnetic handle, realistic oak logs with glowing embers, and MIRRO-FLAME porcelain reflective panels that make the fire look deeper. Choose the PDGDS50 pedestal or FTGDS50 stove feet (one base is required), or add the optional ARCHGDS50 arched door.\u003c\/p\u003e\u003cp\u003eHeat comes from Napoleon's heat exchanger, heat-radiating ceramic glass and a built-in blower, with a split-flow burner that turns down 50% for milder days and up to 74.3% efficiency (propane, CSA P.4.1-15). The included full-function remote runs the thermostat, flame height and blower, and the battery back-up keeps the stove working in a power failure. It is backed by the President's Limited Lifetime Warranty.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 40,000 BTU\/h\u003c\/strong\u003e: natural gas maximum input; propane 39,000 BTU\/h (manual p.8)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 74.3% efficiency\u003c\/strong\u003e: propane model, CSA P.4.1-15 (Napoleon)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProven heat exchanger technology\u003c\/strong\u003e: captures and radiates heat for whole-room warmth\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSplit-flow burner\u003c\/strong\u003e: 50% turn-down for milder days\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in blower\u003c\/strong\u003e: thermally activated; starts 15-30 minutes after lighting (manual p.53)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat-radiating ceramic glass\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRealistic oak logs and embers included\u003c\/strong\u003e: PHAZER logs (manual p.41)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMIRRO-FLAME porcelain reflective panels included\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull-function remote included\u003c\/strong\u003e: thermostat, flame height, blower and more\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePilot on demand\u003c\/strong\u003e: intermittent pilot with continuous pilot mode and 7-day timer (manual p.48)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery back-up control system\u003c\/strong\u003e: keeps the stove working in a power failure (manual p.45)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePedestal or feet base\u003c\/strong\u003e: one base required: PDGDS50 pedestal or FTGDS50 feet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSquare glass doors included\u003c\/strong\u003e: optional ARCHGDS50 arched glass door\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMagnetic door handle included\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePremium safety barrier included\u003c\/strong\u003e: must be installed (manual p.40)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e100% SAFE GUARD gas control system\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFirestop included\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop venting, 4\" \/ 7\" direct vent\u003c\/strong\u003e: co-linear liner option for masonry chimneys (manual p.26)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproved for bedrooms, bathrooms and mobile homes\u003c\/strong\u003e: manual p.7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField convertible to propane\u003c\/strong\u003e: with kit W175-10011046 (2026 price book)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePresident's Limited Lifetime Warranty\u003c\/strong\u003e: manual p.65\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eGDS50N-2 (natural gas, electronic ignition; manual covers GDS50-2NE \/ PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e28 1\/2\" W x 34 3\/4\" H x 21 1\/2\" D (spec sheet W415-10011201)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eNone required (freestanding stove); over carpet, vinyl tile or other combustible flooring other than wood, install on a metal or wood panel the full width and depth of the stove (manual pp.9, 27)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e20 3\/4\" x 12 3\/4\" (Napoleon)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eSide wall 7 in. (178 mm) (A); back wall 2 in. (51 mm) (B); corner installation 2 in. (51 mm) (C) and 10 in. (254 mm) (F); D 18 in. (457 mm) and E 5 in. (127 mm) as marked in the manual clearance figure; at least 20 in. (508 mm) from the top of the stove to the ceiling; at 1 in. from the wall the blower switch, on-off switch and blower power cord may be hard to reach; vent pipe 2 in. at the top and 1 in. at the bottom and sides on horizontal runs, 1 in. all round on vertical runs; keep furniture and other objects at least 48 in. (1.22 m) from the front (manual pp.2, 8, 28)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMax input\u003c\/th\u003e\n\u003ctd\u003eNG 40,000 BTU\/h; LP 39,000 BTU\/h (manual p.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMax steady-state output\u003c\/th\u003e\n\u003ctd\u003eNG 39,071 BTU\/h; LP 36,889 BTU\/h (manual p.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003eup to 74.3% (propane, CSA P.4.1-15; Napoleon)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNG 4.5\" w.c. min, 7\" w.c. max; LP 11\" min, 13\" max (manual p.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManifold pressure\u003c\/th\u003e\n\u003ctd\u003eNG 3.5\" w.c.; LP 10\" w.c. (manual p.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003e115 V, 60 Hz, under 12 A; battery back-up (manual pp.10, 45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eDirect vent, 4\" exhaust \/ 7\" intake, top vent (manual p.13)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBase\u003c\/th\u003e\n\u003ctd\u003ePedestal PDGDS50 or feet FTGDS50 (required, sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eElectronic, pilot on demand (IPI \/ CPI), remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHigh altitude\u003c\/th\u003e\n\u003ctd\u003e2,000-4,500 ft: 10% derate with certified kit; above 4,500 ft reduce 4% per 1,000 ft (manual p.7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA 2.33 \/ ANSI Z21.88 vented gas fireplace heater (manual cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eBTU figures are gas input ratings unless stated as output.\u003c\/p\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHavelock Elite stove body with heat exchanger and built-in blower\u003c\/li\u003e\n\u003cli\u003eSquare glass doors with heat-radiating ceramic glass\u003c\/li\u003e\n\u003cli\u003eOak log set, embers and charcoal (manual pp.41-44)\u003c\/li\u003e\n\u003cli\u003eMIRRO-FLAME porcelain reflective panels\u003c\/li\u003e\n\u003cli\u003ePremium safety barrier (manual p.40)\u003c\/li\u003e\n\u003cli\u003eMagnetic door handle (manual p.12)\u003c\/li\u003e\n\u003cli\u003eFull-function remote control\u003c\/li\u003e\n\u003cli\u003eBattery back-up holder (manual p.45)\u003c\/li\u003e\n\u003cli\u003eFirestop\u003c\/li\u003e\n\u003cli\u003eVent insulation sleeve (manual p.16)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBase, choose one: PDGDS50 pedestal or FTGDS50 stove feet (mandatory per the 2026 price book)\u003c\/li\u003e\n\u003cli\u003e4\" \/ 7\" direct vent system from one approved manufacturer: Wolf Steel, Metal-Fab, BDM, Simpson DuraVent, Selkirk Direct Temp or ICC (manual p.13)\u003c\/li\u003e\n\u003cli\u003eWolf Steel terminations: GD-222R round wall terminal (the only approved wall terminal), GD-110 \/ GD-111 \/ GD-112 roof terminals, GD-180 periscope (manual pp.13-14)\u003c\/li\u003e\n\u003cli\u003eStarter adapter for third-party vent: DuraVent GDS924N, Amerivent 4DSC-N2, Selkirk Direct Temp 4DT-AAN, Metal-Fab Super Seal 4DNA, ICC EXCELDirect or Ventis VDV-NA04-47F (manual p.14)\u003c\/li\u003e\n\u003cli\u003eFloor panel where installed over carpet or vinyl (manual p.9)\u003c\/li\u003e\n\u003cli\u003eHigh-altitude kit for installations from 2,000 to 4,500 ft (manual p.7)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eARCHGDS50 arched glass door\u003c\/li\u003e\n\u003cli\u003eW361-0239-BULK ambient-glow embers\u003c\/li\u003e\n\u003cli\u003eW660-0160 wall mount control\u003c\/li\u003e\n\u003cli\u003eW175-10011046 natural gas to propane conversion kit\u003c\/li\u003e\n\u003cli\u003eCo-linear chimney kit: 3\" aluminium liner (10 to 40 ft) with Simpson DuraVent or Selkirk co-linear to co-axial adapters (manual p.26)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.napoleon.com\/sites\/default\/files\/fireplaces_products\/GDS50-2-Installation-Manual-W415-10010378_b21bb4b2.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation and operation manual (W415-10010378)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.napoleon.com\/sites\/default\/files\/fireplaces_products\/GDS50-2-Specification-sheet-W415-10011201_964fb13a.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet (W415-10011201)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.napoleon.com\/sites\/default\/files\/fireplaces_products\/ADBRN1-HAVELOCKELITE_DIGITAL_afb1c0a8.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHavelock Elite brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This appliance must be installed and serviced by a qualified installer, service agency or gas supplier. The glass gets very hot, so keep children, pets and furniture away and always use the safety barrier.\u003c\/p\u003e\u003ch4\u003eGeneral information (manual pp.7-12)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall and service by a qualified installer, service agency or gas supplier.\u003c\/li\u003e\n\u003cli\u003eCertified as a vented gas fireplace heater (CSA 2.33 \/ ANSI Z21.88); approved for bathrooms, bedrooms and bed-sitting rooms, and for mobile homes when secured through the base (pp.7, 10). In Massachusetts, bedroom and bathroom installs need a sealed direct vent unit (p.9).\u003c\/li\u003e\n\u003cli\u003eRatings: NG 40,000 BTU\/h, LP 39,000 BTU\/h maximum input (p.8).\u003c\/li\u003e\n\u003cli\u003eHigh altitude: 10% derate with the certified kit from 2,000 to 4,500 ft; above 4,500 ft reduce input 4% per 1,000 ft (p.7).\u003c\/li\u003e\n\u003cli\u003eDo not operate below 32°F (0°C), and never run it with the glass removed (p.2).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (manual pp.13-26)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e4\" \/ 7\" vent from one approved manufacturer; never mix brands. Support the vent every 3 ft (p.13).\u003c\/li\u003e\n\u003cli\u003eUp to 20 ft horizontal and 40 ft vertical; at most two horizontal or three vertical flex connections; 1\/4\" per foot rise on horizontal flex runs (p.14).\u003c\/li\u003e\n\u003cli\u003eWall terminal: GD-222R round terminal only. Periscope: bottom air slot at least 12\" above grade, 8 ft maximum on a stove (pp.13, 16).\u003c\/li\u003e\n\u003cli\u003eTerminal clearances include 12\" above grade, 9\" (US) from opening windows, 3 ft (US) from a mechanical air inlet, 16\" above the roof and 7 ft above a paved sidewalk or driveway (pp.17-18).\u003c\/li\u003e\n\u003cli\u003eMasonry chimney: 3\" co-linear aluminium liner, 10 to 40 ft, with approved co-linear to co-axial adapters (p.26).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation (manual pp.27-33)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFit the pedestal or legs first; secure the base when installing in a mobile home (pp.10, 28).\u003c\/li\u003e\n\u003cli\u003eKeep 7\" to a side wall, 2\" to the back wall, 2\" and 10\" in a corner installation, and at least 20\" from the top of the stove to the ceiling (p.28).\u003c\/li\u003e\n\u003cli\u003eSeal vent joints with red high-temperature RTV (W573-0002) or Mill-Pac (W573-0007) (pp.27, 31-33).\u003c\/li\u003e\n\u003cli\u003eInstall on a metal or wood floor panel over carpet or vinyl (p.27).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas (manual p.39)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUse the gas type on the rating plate; inlet NG 4.5-7\" w.c., LP 11-13\" w.c.\u003c\/li\u003e\n\u003cli\u003eDisconnect the stove from the supply when pressure-testing above 1\/2 psig (p.2).\u003c\/li\u003e\n\u003cli\u003eLeak-test all connections with soap solution, never a flame.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eElectrical (manual pp.9, 45)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003ePlug the blower into a properly grounded receptacle; never remove the ground prong.\u003c\/li\u003e\n\u003cli\u003eNever wire 110 V to the gas valve.\u003c\/li\u003e\n\u003cli\u003eFit batteries in the back-up holder so the stove runs in a power failure (p.45).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinishing (manual pp.40-44)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall the safety barrier and door; the barrier must always be in place (p.40).\u003c\/li\u003e\n\u003cli\u003ePlace the oak logs, embers and charcoal on the burner (pp.41-44).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eOperation and maintenance (manual pp.46-54)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eKeep furniture and combustibles at least 48\" from the front (p.8).\u003c\/li\u003e\n\u003cli\u003eHave the stove and venting inspected before first use and at least once a year: clean the burner, pilot, flame sensor and igniter, check gaskets and the relief system, replace batteries (pp.51-52).\u003c\/li\u003e\n\u003cli\u003eClean the glass after the first 4 hours of use with an ammonia-free, non-abrasive cleaner (p.54).\u003c\/li\u003e\n\u003cli\u003eFit a carbon monoxide detector (pp.3-4).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUS: local codes, or where none apply the latest \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\" target=\"_blank\" rel=\"noopener\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eCanada: CSA B149.1 Natural Gas and Propane Installation Code and CSA C22.1 Canadian Electrical Code (\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"noopener\"\u003eCSA Group\u003c\/a\u003e).\u003c\/li\u003e\n\u003cli\u003eElectrical (US): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\" target=\"_blank\" rel=\"noopener\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eManufactured \/ mobile homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\" target=\"_blank\" rel=\"noopener\"\u003eHUD 24 CFR Part 3280\u003c\/a\u003e (or ANSI\/NFPA 501A where 3280 does not apply); Canada CAN\/CSA Z240 MH.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNapoleon President's Limited Lifetime Warranty (Havelock Elite installation and operation manual W415-10010378 B-0, section 11.0, pp.65-66).\u003c\/li\u003e\n\u003cli\u003eLifetime, for as long as the original purchaser owns it: combustion chamber, heat exchanger, steel burner, PHAZER logs and embers, rocks, ceramic glass (thermal breakage only), gold-plated parts (tarnish), porcelain enamel components and aluminum extrusion trim.\u003c\/li\u003e\n\u003cli\u003eElectrical (110 V and millivolt) components and wear parts (blowers, gas valves, thermal switches, switches, wiring, remote controls, igniters, gaskets, pilot assemblies): replacement parts free in the first year.\u003c\/li\u003e\n\u003cli\u003eLabour for warranty repairs: free in the first year, with prior approval through an authorized dealer, at Napoleon's set rate schedule (gas log sets excluded).\u003c\/li\u003e\n\u003cli\u003eYears 1 to 10: defective lifetime-covered parts repaired or replaced free at Napoleon's discretion; from 10 years on, replacement parts at 50% of the current retail price.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original purchaser, bought through an authorized Napoleon dealer and installed by a licensed, authorized technician per the instructions and local codes; non-transferable; starts at original installation; proof of purchase with model and serial number needed.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: misuse, neglect, lack of maintenance, accidents, alteration, other makers' parts, heat or chemical damage to finishes, chipped porcelain, mechanical breakage of PHAZER logs, overfiring, downdrafts, venting or negative-pressure problems, water, weather or condensation damage; shipping, travel and diagnostic charges.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — GDS50N-2\u003c\/h3\u003e\u003ch4\u003eHow close can it go to a wall?\u003c\/h4\u003e\u003cp\u003e7 in. from a side wall and 2 in. from the back wall; in a corner installation 2 in. and 10 in. The top of the stove needs at least 20 in. to the ceiling, and furniture should stay at least 48 in. from the front. At 1 in. from the wall the blower and on-off switches may be hard to reach.\u003c\/p\u003e\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003e4\" \/ 7\" direct vent pipe through the top of the stove, from one approved brand (never mixed): up to 20 ft horizontally through a wall or 40 ft vertically through the roof. The only approved wall terminal is the GD-222R, and it can also vent into an existing masonry chimney with a 3\" co-linear aluminium liner 10 to 40 ft long.\u003c\/p\u003e\u003ch4\u003eCan it be converted to propane?\u003c\/h4\u003e\u003cp\u003eYes, with Napoleon conversion kit W175-10011046. On propane it is rated 39,000 BTU\/h maximum input.\u003c\/p\u003e\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. With batteries in the back-up holder the battery back-up control system keeps the stove working during a power failure.\u003c\/p\u003e\u003ch4\u003eIs a remote included?\u003c\/h4\u003e\u003cp\u003eYes. A full-function remote is included and runs the thermostat, flame height, blower and more.\u003c\/p\u003e\u003ch4\u003eWhat is the warranty?\u003c\/h4\u003e\u003cp\u003eThe Napoleon President's Limited Lifetime Warranty: lifetime coverage on the combustion chamber, heat exchanger, burner, PHAZER logs and other listed parts for the original purchaser, with electrical components, wear parts and labour covered in the first year.\u003c\/p\u003e","brand":"Napoleon","offers":[{"title":"Default Title","offer_id":50593574813858,"sku":"GDS50N-2","price":4829.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/nap-pad-46375166607522.jpg?v=1795247179","url":"https:\/\/unitedfireplaces.com\/products\/napoleon-gds50-2","provider":"United Fireplaces","version":"1.0","type":"link"}