{"product_id":"napoleon-gdix3n","title":"Napoleon Oakville X3 Gas Fireplace Insert GDIX3N-1","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Napoleon Oakville X3 (GDIX3N-1) is a mid-size gas insert that turns an old, drafty wood-burning fireplace into an efficient, clean-burning gas fire. It suits standard masonry or factory-built wood fireplaces (minimum opening about 29\" wide x 21\" high x 14 3\/8\" deep) and is approved for living rooms, bedrooms, bathrooms and permanently sited mobile homes.\u003c\/p\u003e\u003cp\u003eThe clean-face, full-view design shows a 22 11\/16\" x 15\" (about 340 sq in) picture of full-firebox flames over a 7-piece PHAZER split oak log set with glowing embers, lit from above by top lights. Choose the firebox look with the mandatory decorative panels (MIRRO-FLAME black porcelain or Newport or Westminster brick), switch to the optional birch or driftwood log kits, and finish the face with black or charcoal faceplates and backerplates or the 7\" cast iron surround.\u003c\/p\u003e\u003cp\u003eA dual-burner system fully modulates the front and rear burners up to 30,000 BTU\/h input on natural gas (brochure; manual p.6), enough to zone-heat a living room or family room. Add the optional BKGDIX3 heat-circulating blower to push more warm air into the room; it adds about 2 3\/4\" to the insert's depth.\u003c\/p\u003e\u003cp\u003eElectronic ignition with pilot on demand (IPI, with a continuous pilot mode for cold weather) saves gas, and the battery back-up keeps it running during a power failure. The 2026 price book lists the eFIRE Bluetooth controller (EFCN) as included, so you can run flame height, the rear burner, night light and thermostat from your phone or the remote.\u003c\/p\u003e\u003cp\u003eVenting is by two 3\" aluminium liners (intake and exhaust) run up the existing chimney, from 10 to 45 ft, using Napoleon's GDI-320KT to GDI-345KT liner kits. Compared with the Oakville X4, the X3 fits smaller fireplace openings and costs less, and it is the only one of the two with the cast iron surround option.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 30,000 BTU\/h natural gas\u003c\/strong\u003e: dual burner; input from the manual rating table (p.6) and brochure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-burner system\u003c\/strong\u003e: full modulation of front and rear burners up to 30,000 BTU\/h (brochure)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean-face, full-view design\u003c\/strong\u003e: about 22 11\/16\" x 15\" (340 sq in) (spec sheet, brochure)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull-firebox flames\u003c\/strong\u003e: with top lights for an illuminated firebox (brochure)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSplit oak logs included\u003c\/strong\u003e: PHAZER split oak log set, 7 logs, with glowing embers (manual p.20)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional heat-circulating blower\u003c\/strong\u003e: BKGDIX3 kit; adds about 2 3\/4\" of depth (2026 price book; manual p.10)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeFIRE Bluetooth controller included\u003c\/strong\u003e: EFCN (NG) \/ EFCP (LP) included per 2026 price book; app and remote control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-radiating ceramic glass\u003c\/strong\u003e: 5 mm ceramic glass door\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard safety barrier\u003c\/strong\u003e: supplied and must be installed (manual)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame and heat adjustment\u003c\/strong\u003e: HI \/ LO flame and split-flow rear burner\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePilot-on-demand electronic ignition\u003c\/strong\u003e: IPI with continuous pilot (CPI) mode and 7-day timer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery back-up control\u003c\/strong\u003e: works in a power failure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNight light\u003c\/strong\u003e: dimmable from the remote\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMandatory decorative panels\u003c\/strong\u003e: MIRRO-FLAME porcelain or Newport \/ Westminster brick\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFaceplates and backerplates\u003c\/strong\u003e: clean contemporary black or charcoal trims (optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3\" co-linear liner venting\u003c\/strong\u003e: 10 to 45 ft liner kits GDI-320KT to GDI-345KT\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFlex connector included\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eApproved for bedrooms, bathrooms and mobile homes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField convertible to propane\u003c\/strong\u003e: conversion kit sold separately\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePresident's Limited Lifetime Warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eGDIX3N-1 (natural gas, electronic ignition)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e28 5\/8\" W x 20 15\/16\" H x 14 3\/8\" D; deeper with the optional blower (spec sheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum fireplace opening\u003c\/th\u003e\n\u003ctd\u003e21\" H x 29\" W x 14 3\/8\" D, plus 2 3\/4\" depth for the blower (manual p.10; spec sheet shows 21 1\/2\" H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e22 11\/16\" x 15\" (spec sheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eCombustible mantel projecting up to 3\": at least 12\" from the bottom of the mantel to the top of the insert, and deeper mantels must be mounted higher; the same applies to combustibles protruding at either side; non-combustible hearth at least 12\" in front (or raise the insert 4\" \/ use a Wolf Steel riser box over a combustible hearth); furniture and other combustibles at least 48\" from the front (manual pp.10, 15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMax input\u003c\/th\u003e\n\u003ctd\u003eNatural gas up to 30,000 BTU\/h, 0-4,500 ft (manual p.6; brochure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMax output\u003c\/th\u003e\n\u003ctd\u003e18,540 BTU\/h as listed in the manual rating table (p.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNG 4.5\" w.c. min, 7\" w.c. max; LP 11\" w.c. min, 13\" w.c. max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManifold pressure\u003c\/th\u003e\n\u003ctd\u003eNG 3.5\" w.c.; LP 10\" w.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eTwo 3\" aluminium liners (intake and exhaust), 10 to 45 ft; minimum chimney flue 6\" round\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eElectronic, pilot on demand (IPI \/ CPI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHigh altitude\u003c\/th\u003e\n\u003ctd\u003eRated 0-4,500 ft; above 4,500 ft reduce input 4% per 1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA 2.33 \/ ANSI Z21.88 and CSA 2.22 \/ ANSI Z21.50 (manual cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eBTU figures are gas input ratings unless stated as output.\u003c\/p\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsert: 28 5\/8\" wide x 20 15\/16\" high x 14 3\/8\" deep (spec sheet; dimension figure manual p.10)\u003c\/li\u003e\n\u003cli\u003eMinimum fireplace opening: 21\" high x 29\" wide x 14 3\/8\" deep, plus 2 3\/4\" depth with the optional blower (manual p.10)\u003c\/li\u003e\n\u003cli\u003eMust be recessed into a vented, non-combustible wood-burning fireplace, masonry or factory-built, that is clean and sound; remove the damper or lock it fully open\u003c\/li\u003e\n\u003cli\u003eCombustible mantel projecting up to 3\": at least 12\" from the bottom of the mantel to the top of the insert; deeper mantels must be mounted higher (manual pp.10, 15)\u003c\/li\u003e\n\u003cli\u003eHearth: a non-combustible hearth extending at least 12\" in front; a combustible hearth is allowed if the insert is raised 4\" or set on a Wolf Steel riser box\u003c\/li\u003e\n\u003cli\u003eFloor: over carpet, vinyl or other combustible flooring (other than wood) use a metal or wood panel the full width and depth\u003c\/li\u003e\n\u003cli\u003eKeep furniture and other combustibles at least 48\" from the front\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOakville X3 insert with dual burner, top lights and ceramic glass door\u003c\/li\u003e\n\u003cli\u003ePHAZER split oak log set (7 logs), glowing and charcoal embers (manual pp.20, 23-24)\u003c\/li\u003e\n\u003cli\u003eRemote W660-0203 with Bluetooth control module (manual parts list)\u003c\/li\u003e\n\u003cli\u003eeFIRE Bluetooth controller EFCN (2026 price book: included)\u003c\/li\u003e\n\u003cli\u003eSafety barrier\u003c\/li\u003e\n\u003cli\u003eFlex connector and four levelling legs\u003c\/li\u003e\n\u003cli\u003eWarning tag to fix inside the existing firebox\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDecorative panels, choose one: PRPI3 MIRRO-FLAME black porcelain, DBPI3NS Newport brick or DBPI3WS Westminster brick (manual p.22: panels are required; 2026 price book: mandatory)\u003c\/li\u003e\n\u003cli\u003e3\" co-linear aluminium liner kit sized to your chimney: GDI-320KT (20 ft), GDI-325KT (25 ft), GDI-335KT (35 ft) or GDI-345KT (45 ft)\u003c\/li\u003e\n\u003cli\u003e24-gauge sheet-metal flue cover plate sealed around the liners at the damper area\u003c\/li\u003e\n\u003cli\u003eGas line to the insert with a shut-off valve (T-handle in Massachusetts)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBKGDIX3 blower kit\u003c\/li\u003e\n\u003cli\u003eBLKIX3 birch log kit with charcoal\u003c\/li\u003e\n\u003cli\u003eDLKIX3 driftwood log kit\u003c\/li\u003e\n\u003cli\u003eBackerplates: BK4B3142 4-sided, LBK3B3048 large 3-sided, MBK3B2846 medium 3-sided, SBK3B2540 small 4-sided (all black)\u003c\/li\u003e\n\u003cli\u003eFaceplates for the backerplates: LBK3F3B3 \/ LCH3F3B3, LBK4F4B3 \/ LCH4F4B3, SBK3F3B3 \/ SCH3F3B3, SBK4F3B3 \/ SCH4F3B3, SABK4F3B3 \/ SACH4F3B3, SBK4F4B3 \/ SCH4F4B3 (black \/ charcoal)\u003c\/li\u003e\n\u003cli\u003eCISI3BK 7\" black cast iron surround\u003c\/li\u003e\n\u003cli\u003eGI-RB3 riser box, 3\" high x 48\" wide\u003c\/li\u003e\n\u003cli\u003eW175-0823 natural gas to propane conversion kit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.napoleon.com\/sites\/default\/files\/fireplaces_products\/Oakville%20Series%20Installation%20Manual%20-%20%0AW415-4083_2b0e67c4.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual (W415-4083)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.napoleon.com\/sites\/default\/files\/fireplaces_products\/Oakville%20Series%20Owner%27s%20Manual%20-%20%0AW415-3033_32be47d8.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOwner's manual (W415-3033)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.napoleon.com\/sites\/default\/files\/fireplaces_products\/Oakville%20X3%20Specification%20Sheet%20-%20%0AW415-1927_2d2170ad.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet (W415-1927)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.napoleon.com\/sites\/default\/files\/fireplaces_products\/ADBRN1-OAKVILLE%20DIGITAL_9b6618a6.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOakville series brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/images.salsify.com\/image\/upload\/s--jLj3p66p--\/udmudz05c1aqvvtjaq5n.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBKGDIX3 blower installation instructions (W415-1882)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eProduct video\u003c\/h3\u003e\u003cdiv class=\"uf-desc-video\" style=\"position:relative;width:100%;max-width:960px;aspect-ratio:16\/9;margin:0 0 16px\"\u003e\u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/zI-hSLMf9z8?rel=0\" title=\"Napoleon Oakville Series Gas Inserts\" loading=\"lazy\" style=\"position:absolute;inset:0;width:100%;height:100%;border:0;border-radius:4px\" allow=\"accelerometer; encrypted-media; gyroscope; picture-in-picture; fullscreen\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This appliance must be installed and serviced by a qualified professional following Napoleon's installation manual. The glass gets very hot, so keep children, pets and furniture away and always use the safety barrier.\u003c\/p\u003e\u003ch4\u003eGeneral information (manual pp.5-10)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall and service by a qualified installer, service agency or gas supplier; in Massachusetts a licensed plumber or gas fitter, a T-handle shut-off, a flex connector no longer than 36\" and CO detectors are required, and the damper must be removed or welded open.\u003c\/li\u003e\n\u003cli\u003eCertified to CSA 2.33 \/ ANSI Z21.88 and CSA 2.22 \/ ANSI Z21.50; approved for bathrooms, bedrooms, bed-sitting rooms and mobile homes; indoor use only (pp.5-7).\u003c\/li\u003e\n\u003cli\u003eAbove 4,500 ft reduce input 4% per 1,000 ft unless the local authority says otherwise.\u003c\/li\u003e\n\u003cli\u003eMinimum opening 21\" H x 29\" W x 14 3\/8\" D (add 2 3\/4\" for the blower); minimum chimney flue 6\" round (p.10).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInstallation planning (manual pp.11-14)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eThe existing fireplace must be vented, non-combustible and wood-burning (masonry or factory-built), cleaned and repaired first; sheet metal must not be cut, though refractory, doors, screen rails and grates may be removed.\u003c\/li\u003e\n\u003cli\u003eA gas access hole of 1 1\/2\" or less may be drilled through the lower sides or bottom and plugged afterward.\u003c\/li\u003e\n\u003cli\u003eRun two 3\" liners 10 to 45 ft; sleeve liners that pass through unheated spaces; seal the flue cover plate at the damper.\u003c\/li\u003e\n\u003cli\u003eLevel the insert with its four legs; disconnect the gas line before testing above 1\/2 psig and leak-test with soap solution.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinishing (manual pp.15-25)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMount a combustible mantel projecting up to 3\" at least 12\" above the top of the insert (deeper mantels higher); keep the 12\" non-combustible hearth.\u003c\/li\u003e\n\u003cli\u003eInstall the decorative panels (required) before the logs.\u003c\/li\u003e\n\u003cli\u003ePlace the 7 PHAZER logs exactly as shown and never modify their positions (p.20).\u003c\/li\u003e\n\u003cli\u003eFit the safety barrier and door; never run the insert with the glass removed, cracked or broken.\u003c\/li\u003e\n\u003cli\u003eReceiver back-up takes 4 AA batteries, with the slider in the REMOTE (middle) position (p.24).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eElectrical and operation (manual pp.26-31)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eIPI or CPI pilot modes with 7-day timer, chosen by switch or remote; HI \/ LO flame and split-flow rear burner; night light from the remote.\u003c\/li\u003e\n\u003cli\u003eBlower (where fitted) must be grounded; never remove the ground prong or connect 110 V to the valve.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMaintenance (manual pp.34-38)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eHave a qualified technician service the insert every year: clean the firebox, burner and media, replace batteries, inspect the liners and gaskets, clean the blower and flame sensor, and leak-test the gas connections.\u003c\/li\u003e\n\u003cli\u003eNever vacuum hot embers; clean the glass only when cool.\u003c\/li\u003e\n\u003cli\u003eKeep children and pets away from the hot glass; fit a CO detector nearby.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUS: local codes, or where none apply the latest \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\" target=\"_blank\" rel=\"noopener\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eCanada: CSA B149.1 Natural Gas and Propane Installation Code and CSA C22.1 Canadian Electrical Code (\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"noopener\"\u003eCSA Group\u003c\/a\u003e).\u003c\/li\u003e\n\u003cli\u003eElectrical (US): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\" target=\"_blank\" rel=\"noopener\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eManufactured \/ mobile homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\" target=\"_blank\" rel=\"noopener\"\u003eHUD 24 CFR Part 3280\u003c\/a\u003e (or ANSI\/NFPA 501A where 3280 does not apply); Canada CAN\/CSA Z240 MH.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNapoleon President's Limited Lifetime Warranty (Oakville series installation manual W415-3034, section 10.0, p.40; the X3 manual W415-4083 carries the same warranty in section 12.0, p.52).\u003c\/li\u003e\n\u003cli\u003eLifetime, for as long as the original purchaser owns it: combustion chamber, heat exchanger, steel burner, PHAZER logs and embers, rocks, ceramic glass (thermal breakage only), gold-plated parts (tarnish), porcelain enamel components and aluminum extrusion trim.\u003c\/li\u003e\n\u003cli\u003eElectrical (110 V and millivolt) components and wear parts (blowers, gas valves, thermal switches, switches, wiring, remote controls, igniters, gaskets, pilot assemblies): replacement parts free in the first year.\u003c\/li\u003e\n\u003cli\u003eLabour for warranty repairs: free in the first year, with prior approval through an authorized dealer, at Napoleon's set rate schedule (gas log sets excluded).\u003c\/li\u003e\n\u003cli\u003eYears 1 to 10: defective lifetime-covered parts repaired or replaced free at Napoleon's discretion; from 10 years on, replacement parts at 50% of the current retail price.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original purchaser, bought through an authorized Napoleon dealer and installed by a licensed, authorized technician per the instructions and local codes; non-transferable; starts at original installation; proof of purchase with model and serial number needed.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: misuse, neglect, lack of maintenance, accidents, alteration, other makers' parts, heat or chemical damage to finishes, chipped porcelain, mechanical breakage of PHAZER logs, overfiring, downdrafts, venting or negative-pressure problems, water, weather or condensation damage; shipping, travel and diagnostic charges.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including lead and lead compounds, which are known to the State of California to cause cancer, and chemicals including carbon monoxide, which are known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — GDIX3N-1\u003c\/h3\u003e\n\u003ch4\u003eWhat size fireplace opening does the GDIX3N-1 need?\u003c\/h4\u003e\u003cp\u003eA vented, non-combustible wood-burning fireplace (masonry or factory-built) with an opening of at least 21\" H x 29\" W x 14 3\/8\" D, plus 2 3\/4\" of depth if you add the blower. Napoleon's spec sheet shows the minimum height as 21 1\/2\". The chimney flue must be at least 6\" round.\u003c\/p\u003e\n\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003eTwo 3\" aluminium liners, one intake and one exhaust, run up the existing chimney from 10 to 45 ft, using liner kit GDI-320KT, GDI-325KT, GDI-335KT or GDI-345KT.\u003c\/p\u003e\n\u003ch4\u003eCan it be converted to propane?\u003c\/h4\u003e\u003cp\u003eYes. It is field convertible with Napoleon's W175-0823 natural gas to propane conversion kit, sold separately.\u003c\/p\u003e\n\u003ch4\u003eDoes it work in a power outage?\u003c\/h4\u003e\u003cp\u003eYes. The battery back-up keeps the ignition and controls working during a power failure; the receiver back-up takes 4 AA batteries.\u003c\/p\u003e\n\u003ch4\u003eIs a remote included?\u003c\/h4\u003e\u003cp\u003eYes. The W660-0203 remote with Bluetooth control module is included, and Napoleon's 2026 price book lists the eFIRE Bluetooth controller (EFCN) as included for app control.\u003c\/p\u003e\n\u003ch4\u003eWhat is the warranty?\u003c\/h4\u003e\u003cp\u003eNapoleon's President's Limited Lifetime Warranty covers the combustion chamber, heat exchanger, burner, PHAZER logs and ceramic glass (thermal breakage) for as long as the original purchaser owns it. Electrical components and wear parts have free replacement parts in the first year, and labour is covered in the first year with prior approval.\u003c\/p\u003e","brand":"Napoleon","offers":[{"title":"Default Title","offer_id":50593573863586,"sku":"GDIX3N-1","price":3889.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/napoleon-3a5189a326801a50e3aa.png?v=1791689489","url":"https:\/\/unitedfireplaces.com\/products\/napoleon-gdix3n","provider":"United Fireplaces","version":"1.0","type":"link"}