{"product_id":"napoleon-ex36","title":"Napoleon Elevation X 36 Direct Vent Gas Fireplace EX36","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Napoleon Elevation X 36 (EX36NTEL natural gas \/ EX36PTEL propane) is a 36\" built-in direct vent gas fireplace with a traditional full-firebox flame and a clean-face design, so only the fire, logs and firebox panels show through the glass. The unit is 38 3\/4\" wide, 44\" high and 22\" deep with a 36\" x 33 1\/8\" fireplace opening, and it is approved for bedrooms, bathrooms and mobile homes.\u003c\/p\u003e\u003cp\u003eA modulating ENDLESS EMBERS electric ember bed glows under your choice of High Definition Birch, Split Oak or Driftwood logs, and the firebox is lined with Newport, Westminster or Glacier brick, Antique Ledgestone, Black Illusion Glass or MIRRO-FLAME porcelain panels. Whitney and Zen fronts and 2\" or 3.5\" finishing trims are optional.\u003c\/p\u003e\u003cp\u003eInput is up to 37,000 BTU\/h on natural gas and 34,000 BTU\/h on propane, with split flow modulation and an included variable-speed, thermostatic blower. The Proflame II eFIRE Bluetooth controller and remote are included for remote or app control, and a premium safety screen is standard. It vents 5\"\/8\" from the top, up to 20 ft horizontal or 40 ft vertical, and is power-vent ready with the PVALX3 kit.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 37,000 BTU\/h natural gas \/ 34,000 BTU\/h propane\u003c\/strong\u003e: manual p.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModulating ENDLESS EMBERS electric ember bed\u003c\/strong\u003e: adjustable glow under the logs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean-face design with full firebox flame\u003c\/strong\u003e: no visible louvres or hardware around the fire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Definition log kits (required choice)\u003c\/strong\u003e: Birch, Split Oak or Driftwood, with glowing embers and charcoal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDecorative panels (required choice)\u003c\/strong\u003e: Newport, Westminster or Glacier brick (standard or herringbone), Antique Ledgestone, Black Illusion Glass or MIRRO-FLAME porcelain\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSplit flow modulation\u003c\/strong\u003e: switch between full and reduced flame\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProflame II and eFIRE Bluetooth controller with remote included\u003c\/strong\u003e: app control of flame, blower and lights\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-circulating blower included\u003c\/strong\u003e: variable speed with thermostatic control\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePremium safety screen included\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFirestop included\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional decorative fronts and trims\u003c\/strong\u003e: Whitney and Zen fronts; 2\" and 3.5\" bevelled finishing trims\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional heat management\u003c\/strong\u003e: LHAD, Dynamic Heat Control (DHCEX), Dynamic Heat Control Plus, Ducted Heat Management\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop vent, 5\" \/ 8\" direct vent\u003c\/strong\u003e: flexible or rigid components from approved manufacturers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower vent ready\u003c\/strong\u003e: PVALX3 adaptor kit\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOptional ambient-glow embers\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField convertible NG \/ LP\u003c\/strong\u003e: conversion kit with burner\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eApproved for bedrooms, bathrooms and mobile homes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCertified to CSA 2.22 \/ ANSI Z21.50\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePresident's Limited Lifetime Warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModels\u003c\/th\u003e\n\u003ctd\u003eEX36NTEL natural gas \/ EX36PTEL propane, electronic ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUnit dimensions\u003c\/th\u003e\n\u003ctd\u003e38 3\/4\" W x 44\" H x 22\" D (manual p.10; spec sheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFraming dimensions\u003c\/th\u003e\n\u003ctd\u003eRough framing 42 3\/4\" (1086 mm) wide x 22 1\/4\" (565 mm) deep, side framing at least 4 1\/2\" (114 mm), enclosure at least 72\" (182.8 cm) high (manual p.20). Finish framing, flush or recessed: 39 3\/4\" (1010 mm) wide x 44 1\/4\" (1124 mm) high x 22 1\/4\" (565 mm) deep minimum, side framing at least 6\" (152 mm); enclosure at least 72\" (183 cm) high flush or 84\" (213 cm) recessed; recess up to 5 1\/2\" (140 mm) (manual pp.36-37)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003eGlass 27\" x 32 1\/4\" (spec sheet, as listed); fireplace opening inside the finishing flange: 36\" W x 33 1\/8\" H (manual p.10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003eSide wall 6\" (152 mm) minimum (manual p.21); framing may meet the built-in standoff spacers at the top, sides and back, and the supplied header shield sets the header clearance, with 1\" to a combustible enclosure (0\" to brick or stone) (manual pp.9, 19); vent 3\" to the top and 2\" to the sides and bottom of horizontal runs, 1\" all round vertical runs (manual p.13); no hearth extension required; keep objects 48\" (121.9 cm) from the front (manual pp.8, 18); combustible mantel, measured from the top of the fireplace opening (33 1\/8\" above the appliance base): 15\" above for a 2\" deep mantel, 17\" for 4\", 19\" for 6\" and 21\" for 8\" (manual p.44)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas input\u003c\/th\u003e\n\u003ctd\u003eNG 37,000 BTU\/h; LP 34,000 BTU\/h max (manual p.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNG 4.5\" w.c. min, 7\" w.c. max; LP 11\" min, 13\" max; never above 13\" w.c. (manual p.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManifold pressure\u003c\/th\u003e\n\u003ctd\u003eNG 3.5\" w.c.; LP 10\" w.c. (manual p.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003e120 V hard-wired; 115 V, 60 Hz, under 12 A (manual pp.9, 28)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eDirect vent, 5\" exhaust \/ 8\" intake, top (manual p.13)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBlower\u003c\/th\u003e\n\u003ctd\u003eIncluded, variable speed, thermostatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eElectronic, Proflame II \/ eFIRE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHigh altitude\u003c\/th\u003e\n\u003ctd\u003eAbove 4,500 ft reduce input 4% per 1,000 ft (manual p.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eDimensions from the Napoleon specification sheet and installation manual W415-2000. BTU figures are gas input ratings, not delivered heat output.\u003c\/p\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eChoose the framing kit early: non-combustible board kit NCEX36 (no air opening) or combustible framing with DHCEX \/ DHMEX (air outlet opening required) (manual p.18)\u003c\/li\u003e\n\u003cli\u003eFraming or finishing closer than the minimum clearances must be fully non-combustible (ASTM E136 \/ UL763); fire-rated drywall is not acceptable (manual p.18)\u003c\/li\u003e\n\u003cli\u003eWall penetration: 59\" plus rise, measured from the base of the air collar (manual p.14)\u003c\/li\u003e\n\u003cli\u003eCombustible mantels, measured from the top of the fireplace opening: 15\" above for a 2\" deep mantel, 17\" for 4\", 19\" for 6\" and 21\" for 8\" (manual p.44); can be reduced with the DHCEX kit\u003c\/li\u003e\n\u003cli\u003eTV above: Napoleon shows a TV above only with a mantel or a recessed installation, not a flush installation without a mantel; the gap from the top of the finishing flange to the TV must meet the mantel clearances, and Napoleon states that TV temperatures must be validated at installation; the recess frame can be backed with 3\/4\" plywood to carry TV mounting hardware (manual pp.37, 43)\u003c\/li\u003e\n\u003cli\u003eNo hearth extension required; raise the unit flush with the finished floor if optional trims are used. Keep objects 4 ft from the front (manual pp.18, 21)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCeramic glass door and premium safety screen \/ barrier (W010-4616-SER)\u003c\/li\u003e\n\u003cli\u003eModulating ENDLESS EMBERS electric ember bed\u003c\/li\u003e\n\u003cli\u003eHeat-circulating blower, variable speed with thermostat\u003c\/li\u003e\n\u003cli\u003eProflame II \/ eFIRE Bluetooth controller (EFCN natural gas \/ EFCP propane) and remote\u003c\/li\u003e\n\u003cli\u003eFirestop\u003c\/li\u003e\n\u003cli\u003e1\" insulation sleeve for the first 3 ft of vent (manual p.14)\u003c\/li\u003e\n\u003cli\u003eRestrictor plate and header shield (manual pp.19, 27)\u003c\/li\u003e\n\u003cli\u003eHardware kit (manual p.12)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLog kit (mandatory, choose one): Birch BLKEX36, Split Oak OLKEX36 or Driftwood DLKEX36 (2026 price book)\u003c\/li\u003e\n\u003cli\u003eDecorative panels (mandatory, choose one): Newport DBPEX36NS, Westminster DBPEX36WS \/ DBPEX36WH, Glacier DBPEX36GS \/ DBPEX36GH, Antique Ledgestone DBPEX36LS, Black Illusion Glass BIGEX36 or MIRRO-FLAME PRPEX36 (2026 price book)\u003c\/li\u003e\n\u003cli\u003e5\" \/ 8\" direct vent system from one approved manufacturer: wall terminal GD422R-2 \/ ST58U-1, roof terminal GD410 \/ GD411 \/ GD412, periscope GD401, flex kits GD420 (5 ft) \/ GD430 (10 ft) (manual pp.13-26)\u003c\/li\u003e\n\u003cli\u003eStarter adapter for third-party vent: Metal-Fab 5NDA, DuraVent W175-0170, Selkirk 5DT-AAN or Olympia VDV-NA05-58F (manual p.13)\u003c\/li\u003e\n\u003cli\u003eFraming kit: NCEX36 non-combustible board, or DHCEX \/ DHMEX for combustible framing (manual p.18)\u003c\/li\u003e\n\u003cli\u003e120 V hard-wired supply to the junction box (manual p.28)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDecorative fronts: Whitney Black WEX36BK; Zen Black ZEX36BK, Zen Charcoal ZEX36CH\u003c\/li\u003e\n\u003cli\u003eFinishing trims: 2\" Black FTEX36BK, 2\" Charcoal FTEX36CH, 3.5\" bevelled black BTEX36\u003c\/li\u003e\n\u003cli\u003eDynamic Heat Control DHCEX (cannot be combined with LHAD)\u003c\/li\u003e\n\u003cli\u003eDynamic Heat Control Plus: blower kit DHCP-BK with exterior mounting kit DHCP-EK or hot air grill kit DHCP-HK\u003c\/li\u003e\n\u003cli\u003eDucted Heat Management: front discharge DHMEXF, side discharge DHMEXS, termination plate DHMEXTP, front grill DHMFG3850, side grill DHMSG, 8\" flex kit DVK\u003c\/li\u003e\n\u003cli\u003eHot air distribution kit LHAD; hot air exhaust kit GA-72\u003c\/li\u003e\n\u003cli\u003ePower vent adaptor kit PVALX3\u003c\/li\u003e\n\u003cli\u003eAmbient-glow embers W361-0239-BULK\u003c\/li\u003e\n\u003cli\u003eWall mount control W660-0160\u003c\/li\u003e\n\u003cli\u003eConversion kits (burner included): NG to LP W175-0713, LP to NG W175-0714\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/images.salsify.com\/image\/upload\/fl_attachment\/xb3gzuphcuh8umzw5rfq.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation manual (W415-2000)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/images.salsify.com\/image\/upload\/fl_attachment\/gzithk3vnpfsxhcpvzzw.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/images.salsify.com\/image\/upload\/fl_attachment\/akcu4ftn0jdqwan0dbqt.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct support downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eProduct video\u003c\/h3\u003e\u003cdiv class=\"uf-desc-video\" style=\"position:relative;width:100%;max-width:960px;aspect-ratio:16\/9;margin:0 0 16px\"\u003e\u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/HlQNlQrq_3g?rel=0\" title=\"Napoleon Elevation X Gas Fireplace Series\" loading=\"lazy\" style=\"position:absolute;inset:0;width:100%;height:100%;border:0;border-radius:4px\" allow=\"accelerometer; encrypted-media; gyroscope; picture-in-picture; fullscreen\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This appliance must be installed and serviced by a qualified professional following Napoleon's installation manual. The glass gets very hot, so keep children, pets and furniture away and always use the safety barrier.\u003c\/p\u003e\u003ch4\u003eGeneral information (pp.5-12)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall and service by a qualified installer, service agency or gas supplier; indoor use only.\u003c\/li\u003e\n\u003cli\u003eCertified to CSA 2.22 \/ ANSI Z21.50; approved for bedrooms, bathrooms and bed-sitting rooms and for mobile homes (pp.5, 9).\u003c\/li\u003e\n\u003cli\u003eRating: NG 37,000 BTU\/h, LP 34,000 BTU\/h (p.5).\u003c\/li\u003e\n\u003cli\u003eAbove 4,500 ft reduce input 4% for every 1,000 ft unless the local authority says otherwise (p.5).\u003c\/li\u003e\n\u003cli\u003eField conversion between natural gas and propane only by an authorized dealer with the correct kit (p.9).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting requirements and terminations (pp.13-17)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e5\" \/ 8\" vent from Wolf Steel, Metal-Fab, BDM, Simpson DuraVent, Selkirk or Olympia; never mix brands or rigid with flex.\u003c\/li\u003e\n\u003cli\u003eUp to 20 ft horizontal and 40 ft vertical (3 ft minimum vertical); vertical plus horizontal 40 ft maximum, beyond that a power vent is needed; flex runs allow two horizontal or three vertical connections.\u003c\/li\u003e\n\u003cli\u003eWrap the first 3 ft of 8\" pipe with the supplied 1\" insulation sleeve; support every 3 ft.\u003c\/li\u003e\n\u003cli\u003ePeriscope: maximum 10 ft, bottom air slot 12\" above grade (p.14).\u003c\/li\u003e\n\u003cli\u003eTerminal clearances include 12\" above grade, 9\" (US) from opening windows or doors, 3 ft (US) from a mechanical air inlet, 7 ft above a public sidewalk, 16\" above the roof and 2 ft from an adjacent wall (p.16).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eRough framing (pp.18-22)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003ePlan the framing kit (NCEX non-combustible, or DHCEX \/ DHMEX) before framing.\u003c\/li\u003e\n\u003cli\u003eInstall the header shield; keep 1\" to combustible enclosures (0\" to brick or stone).\u003c\/li\u003e\n\u003cli\u003eNo hearth extension required; keep 4 ft clear in front.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting installation (pp.23-27)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eSeal the exhaust flue collar with Mill Pac; use the correct firestops for each wall or ceiling penetration.\u003c\/li\u003e\n\u003cli\u003eVertical installs may need the restrictor plate set for a steady flame (p.27).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eElectrical (pp.28-31)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eHard-wire 120 V to the junction box per local codes, CSA C22.1 or NFPA 70; never wire 110 V to the valve or wall switch.\u003c\/li\u003e\n\u003cli\u003eThe battery holder takes 4 AA batteries; keep the receiver within 8 ft of the appliance side (p.31).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eGas and operation (pp.32-34)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUse the gas type on the rating plate; leak-test with soap solution, never a flame.\u003c\/li\u003e\n\u003cli\u003eElectronic ignition lights the pilot; pilot-on-demand operation per section 7.1.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinish framing and finishing (pp.35-45)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eFlush or recessed framing; facing must be non-combustible and must not overhang the opening or block the door's pressure-relief movement.\u003c\/li\u003e\n\u003cli\u003eInstall decorative panels, logs and embers exactly as shown; install the non-combustible board and adjust the finishing flange (pp.37-41).\u003c\/li\u003e\n\u003cli\u003eCombustible mantel clearances, measured from the top of the fireplace opening: 15\" above for a 2\" deep mantel, 17\" for 4\", 19\" for 6\" and 21\" for 8\" (p.44).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eMaintenance (pp.46-49)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eClean the glass after the first 4 hours with an ammonia-free cleaner; never clean it hot.\u003c\/li\u003e\n\u003cli\u003eHave the appliance and venting inspected at least once a year by a qualified technician.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUS: local codes, or where none apply the latest \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\" target=\"_blank\" rel=\"noopener\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eCanada: CSA B149.1 Natural Gas and Propane Installation Code and CSA C22.1 Canadian Electrical Code (\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"noopener\"\u003eCSA Group\u003c\/a\u003e).\u003c\/li\u003e\n\u003cli\u003eElectrical (US): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\" target=\"_blank\" rel=\"noopener\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eManufactured \/ mobile homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\" target=\"_blank\" rel=\"noopener\"\u003eHUD 24 CFR Part 3280\u003c\/a\u003e (or ANSI\/NFPA 501A where 3280 does not apply); Canada CAN\/CSA Z240 MH.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNapoleon President's Limited Lifetime Warranty (Elevation X installation manual W415-2000, section 13.0, p.61).\u003c\/li\u003e\n\u003cli\u003eLifetime, for as long as the original purchaser owns it: combustion chamber, heat exchanger, steel burner, PHAZER logs and embers, rocks, ceramic glass (thermal breakage only), gold-plated parts (tarnish), porcelain enamel components and aluminum extrusion trim.\u003c\/li\u003e\n\u003cli\u003eElectrical (110 V and millivolt) components and wear parts (blowers, gas valves, thermal switches, switches, wiring, remote controls, igniters, gaskets, pilot assemblies): replacement parts free in the first year.\u003c\/li\u003e\n\u003cli\u003eLabour for warranty repairs: free in the first year, with prior approval through an authorized dealer, at Napoleon's set rate schedule (gas log sets excluded).\u003c\/li\u003e\n\u003cli\u003eYears 1 to 10: defective lifetime-covered parts repaired or replaced free at Napoleon's discretion; from 10 years on, replacement parts at 50% of the current retail price.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original purchaser, bought through an authorized Napoleon dealer and installed by a licensed, authorized technician per the instructions and local codes; non-transferable; starts at original installation; proof of purchase with model and serial number needed.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: misuse, neglect, lack of maintenance, accidents, alteration, other makers' parts, heat or chemical damage to finishes, chipped porcelain, mechanical breakage of PHAZER logs, overfiring, downdrafts, venting or negative-pressure problems, water, weather or condensation damage; shipping, travel and diagnostic charges.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions — EX36\u003c\/h3\u003e\u003ch4\u003eWhat size framing does the EX36 need?\u003c\/h4\u003e\u003cp\u003eRough framing is 42 3\/4\" wide and 22 1\/4\" deep, with an enclosure at least 72\" high. Finish framing is 39 3\/4\" wide x 44 1\/4\" high x 22 1\/4\" deep, flush or recessed up to 5 1\/2\", with the enclosure at least 72\" high for a flush install or 84\" for a recessed one. Keep at least 6\" to a side wall.\u003c\/p\u003e\u003ch4\u003eWhat venting does it use, and how far can it run?\u003c\/h4\u003e\u003cp\u003e5\" exhaust \/ 8\" intake direct vent from the top, using Wolf Steel, Metal-Fab, BDM, Simpson DuraVent, Selkirk or Olympia components: up to 20 ft horizontal and 40 ft vertical, with at least 3 ft vertical. Longer or difficult runs can use the PVALX3 power vent adaptor kit.\u003c\/p\u003e\u003ch4\u003eCan it be converted between natural gas and propane?\u003c\/h4\u003e\u003cp\u003eYes. It is field convertible with Napoleon kits that include the burner: NG to LP W175-0713 or LP to NG W175-0714, fitted by an authorized dealer. Input is 37,000 BTU\/h on natural gas and 34,000 BTU\/h on propane.\u003c\/p\u003e\u003ch4\u003eIs a remote included?\u003c\/h4\u003e\u003cp\u003eYes. The Proflame II eFIRE Bluetooth controller (EFCN natural gas \/ EFCP propane) and remote are included, so the flame, blower and ember bed run from the remote or the eFIRE app. A wall mount control W660-0160 is optional.\u003c\/p\u003e\u003ch4\u003eCan a TV go above it, and how high must the mantel be?\u003c\/h4\u003e\u003cp\u003eNapoleon shows a TV above only with a mantel or a recessed installation, not a flush installation without a mantel. Combustible mantels are measured from the top of the fireplace opening: 15\" above for a 2\" deep mantel, 17\" for 4\", 19\" for 6\" and 21\" for 8\". The optional Dynamic Heat Control kit DHCEX can reduce mantel clearances.\u003c\/p\u003e\u003ch4\u003eWhat is the warranty?\u003c\/h4\u003e\u003cp\u003eNapoleon's President's Limited Lifetime Warranty for the original purchaser: lifetime cover on the combustion chamber, heat exchanger, burner, logs and glass (thermal breakage), free in years 1 to 10 and at 50% of retail after that; electrical components, wear parts and labour in the first year.\u003c\/p\u003e","brand":"Napoleon","offers":[{"title":"Natural Gas","offer_id":50593569276066,"sku":"EX36NTEL","price":4929.0,"currency_code":"USD","in_stock":true},{"title":"Propane","offer_id":50593569308834,"sku":"EX36PTEL","price":4929.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/napoleon-7950201bad6bd19d3dd4.jpg?v=1791689425","url":"https:\/\/unitedfireplaces.com\/products\/napoleon-ex36","provider":"United Fireplaces","version":"1.0","type":"link"}