{"product_id":"napoleon-b46","title":"Napoleon Ascent 46 Direct Vent Gas Fireplace B46","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Napoleon Ascent 46 (B46NTRE) is a traditional built-in direct vent gas fireplace with a hand-painted oak log set and a classic firebox look. It suits living rooms, family rooms, basements, bedrooms and even bathrooms, since the manual approves it for bathroom, bedroom and bed-sitting room installations as well as mobile and manufactured homes. Available models: B46NTRE (natural gas, electronic) and B46NTR (natural gas, millivolt).\u003c\/p\u003e\u003cp\u003eBehind the tempered glass, the GL-706 log set sits on glowing and charcoal embers over a pan-style burner. The look is yours to set: add a Heritage or Zen black front, a 3\" trim, MIRRO-FLAME black porcelain reflective panels or brick panels, and swap the logs for beach fire, shore fire, woodland or mineral rock media. A safety barrier comes standard to keep hands away from the hot glass.\u003c\/p\u003e\u003cp\u003eThe Ascent 46 is rated up to 22,000 BTU\/h input on natural gas (propane versions B46PTRE \/ B46PTR are also made; the manual text gives no separate propane input, p.5). Flame height adjusts for heat and ambiance, and the optional AUB variable-speed blower pushes more warm air into the room. The optional LHAD hot air distribution kit can carry warm air to another room through flexible ducting.\u003c\/p\u003e\u003cp\u003eElectronic models use intermittent pilot ignition (IPI) with a continuous pilot (CPI) mode for cold weather and a seven-day timer, and a battery back-up keeps the fireplace working in a power outage. Millivolt models need no outside electricity at all. Add the F45 on\/off remote or the F60 thermostatic remote for control from the couch.\u003c\/p\u003e\u003cp\u003eInstallation is flexible: 4\" \/ 7\" direct vent pipe exits from the top or rear and runs up to 20 ft horizontally or 40 ft vertically, periscope terminations suit below-grade walls, and a 3\" co-linear liner (10 to 40 ft) lets you vent up an existing masonry chimney. In the Ascent line it is the widest traditional Ascent, with the same 22,000 BTU burner as the 42 in a wider firebox. It carries Napoleon's President's Limited Lifetime Warranty.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHand-painted oak log set included\u003c\/strong\u003e: GL-706 (napoleon.com; brochure)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlowing and charcoal embers\u003c\/strong\u003e: W415-2370 finishing chapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePan-style burner\u003c\/strong\u003e: napoleon.com features\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 22,000 BTU\/h\u003c\/strong\u003e: propane versions B46PTRE \/ B46PTR are also made; the manual text gives no separate propane input, p.5\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFlame and heat adjustment\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTempered heat-resistant glass\u003c\/strong\u003e: brochure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard safety barrier\u003c\/strong\u003e: included and required (manual)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic IPI ignition with CPI mode and 7-day timer\u003c\/strong\u003e: manual chapter 7.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMillivolt version available\u003c\/strong\u003e: no external electricity needed (manual chapter 8.0)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery back-up control\u003c\/strong\u003e: 4 AA batteries keep it lighting in a power failure (brochure; manual chapter 5.2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional remote controls\u003c\/strong\u003e: F45 on\/off or F60 thermostatic remote (2026 price book)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional AUB blower\u003c\/strong\u003e: variable speed and thermostatic control (2026 price book)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional LHAD hot air distribution kit\u003c\/strong\u003e: with GA-72 hot air exhaust kit and GA-70 5 ft extension (2026 price book)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDecorative fronts and trims\u003c\/strong\u003e: H46F Heritage or Z46F Zen black decorative front; BT46K 3\" black 4-sided bevelled trim\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDecorative panels\u003c\/strong\u003e: PRPB46 MIRRO-FLAME black porcelain reflective panels; DBPB46WH Westminster herringbone or DBPB46WS Westminster standard brick panels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedia enhancement kits\u003c\/strong\u003e: BFKS beach fire log set, SFKM shore fire kit, WLKM woodland kit, MRKM mineral rocks (with RR42 media support bracket), W361-0239-BULK ambient-glow embers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop or rear direct venting\u003c\/strong\u003e: 4\" \/ 7\"; 20 ft horizontal \/ 40 ft vertical (manual chapter 2.0)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExisting-chimney option\u003c\/strong\u003e: 3\" co-linear liner, 10-40 ft (manual chapter 4.4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproved for bathrooms, bedrooms and mobile homes\u003c\/strong\u003e: manual chapter 1.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField convertible\u003c\/strong\u003e: W175-0418 (electronic) or W175-0420 (millivolt) conversion kit (2026 price book)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified to CSA 2.22 \/ ANSI Z21.50\u003c\/strong\u003e: manual cover\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePresident's Limited Lifetime Warranty\u003c\/strong\u003e: section 18.0\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel \/ MPN\u003c\/th\u003e\n\u003ctd\u003eB46NTRE (natural gas, electronic) and B46NTR (natural gas, millivolt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMax input\u003c\/th\u003e\n\u003ctd\u003eNatural gas 22,000 BTU\/h at 0-4,500 ft; propane versions B46PTRE \/ B46PTR are also made; the manual text gives no separate propane input, p.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNG 4.5\" w.c. min \/ 7\" max; LP 11\" w.c. min \/ 13\" max (manual chapter 1.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManifold pressure\u003c\/th\u003e\n\u003ctd\u003eNG 3.5\" w.c.; LP 10\" w.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2\" supply with flex connector (3\/8\" without) (manual chapter 6.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003e115 V, 60 Hz, under 12 A (rating plate); battery back-up with 4 AA batteries and the supplied 6 V pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eDirect vent, 4\" exhaust \/ 7\" intake, top or rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFireplace dimensions\u003c\/th\u003e\n\u003ctd\u003e46\" W x 34 5\/8\" H x 18 5\/16\" D (manual chapter 1.5; brochure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum rough framing\u003c\/th\u003e\n\u003ctd\u003e46 1\/2\" W x 18 9\/16\" D based on 1\/2\" finishing (manual chapter 3.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum enclosure height\u003c\/th\u003e\n\u003ctd\u003e50 1\/2\" (top vent) \/ 41 5\/8\" (rear vent) (manual chapter 3.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHigh altitude\u003c\/th\u003e\n\u003ctd\u003eAbove 4,500 ft reduce input 4% per 1,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eCSA 2.22 \/ ANSI Z21.50, vented decorative gas appliance; indoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eBTU figures are gas input ratings. The installation manual (W415-2370) is the authority for framing, clearances and venting.\u003c\/p\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFireplace: 46\" W x 34 5\/8\" H x 18 5\/16\" D (manual chapter 1.5)\u003c\/li\u003e\n\u003cli\u003eMinimum rough framing: 46 1\/2\" W x 18 9\/16\" D; minimum enclosure height 50 1\/2\" (top vent) \/ 41 5\/8\" (rear vent) (manual chapters 3.1-3.2)\u003c\/li\u003e\n\u003cli\u003eHorizontal vent pipe: 1\" at the bottom and sides, 3\" at the top (1\" with at least 38\" of vertical rise off the collar)\u003c\/li\u003e\n\u003cli\u003eVertical vent: 1\" all round (manual chapter 3.1)\u003c\/li\u003e\n\u003cli\u003eFraming must not be notched around the standoffs; non-combustible facing (tile, marble, non-combustible board) is required where the manual specifies it, never wood or drywall; brick or stone finishes may go to 0\" when non-combustible (manual chapters 3.0, 10.3)\u003c\/li\u003e\n\u003cli\u003eMantels: follow the mantel clearance chart in the manual (chapter 10.4); high heat can damage a TV or decorations above the fireplace, so respect the clearances\u003c\/li\u003e\n\u003cli\u003eFloor: over carpet, vinyl or other combustible flooring (other than wood), install on a metal or wood panel the full width and depth of the unit\u003c\/li\u003e\n\u003cli\u003eKeep furniture and other objects at least 48\" from the front\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAscent 46 direct vent firebox with tempered glass door\u003c\/li\u003e\n\u003cli\u003eGL-706 hand-painted oak log set (napoleon.com lists it as included)\u003c\/li\u003e\n\u003cli\u003eGlowing embers and charcoal embers\u003c\/li\u003e\n\u003cli\u003eStandard safety barrier\u003c\/li\u003e\n\u003cli\u003eStandoffs and nailing tabs\u003c\/li\u003e\n\u003cli\u003e6 V battery pack (4 AA batteries not supplied)\u003c\/li\u003e\n\u003cli\u003eLogo\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4\" \/ 7\" direct vent system from one approved manufacturer: Wolf Steel, Metal-Fab SureSeal, Simpson DuraVent Direct Vent Pro, BDM Pro-Form or Selkirk Direct Temp; never mix systems\u003c\/li\u003e\n\u003cli\u003eStarter adaptor where the vent brand needs one: 4DNA (Metal-Fab), W175-0053 (DuraVent), DVR6-STA7 (BDM) or 4DT-AAN (Selkirk)\u003c\/li\u003e\n\u003cli\u003eA Wolf Steel termination: wall terminal GD-222, GD-222R or ST47U; roof terminal GD-110 (1\/12-7\/12), GD-111 (8\/12-12\/12) or GD-112 (flat); or periscope GD-201\u003c\/li\u003e\n\u003cli\u003eFirestops where the vent passes through walls, floors or ceilings: W010-3440 or 4DHFSN (horizontal), W500-0292 or 4DFS (vertical); vent supports every 3 ft (W010-0067)\u003c\/li\u003e\n\u003cli\u003eFloor panel where installed over carpet or vinyl\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eH46F Heritage or Z46F Zen black decorative front\u003c\/li\u003e\n\u003cli\u003eBT46K 3\" black 4-sided bevelled trim\u003c\/li\u003e\n\u003cli\u003ePRPB46 MIRRO-FLAME black porcelain reflective panels; DBPB46WH Westminster herringbone or DBPB46WS Westminster standard brick panels\u003c\/li\u003e\n\u003cli\u003eBFKS beach fire log set, SFKM shore fire kit, WLKM woodland kit, MRKM mineral rocks (with RR42 media support bracket), W361-0239-BULK ambient-glow embers\u003c\/li\u003e\n\u003cli\u003eF45 remote control, on\/off with digital screen\u003c\/li\u003e\n\u003cli\u003eF60 thermostatic remote control with digital screen\u003c\/li\u003e\n\u003cli\u003eW660-0081 wall mount digital thermostat\u003c\/li\u003e\n\u003cli\u003eAUB blower kit, variable speed and thermostatic control\u003c\/li\u003e\n\u003cli\u003eLHAD hot air distribution kit, GA-72 hot air exhaust kit, GA-70 5 ft flex extension\u003c\/li\u003e\n\u003cli\u003eW175-0418 (electronic) or W175-0420 (millivolt) natural gas to propane conversion kit\u003c\/li\u003e\n\u003cli\u003eGD-220 (5 ft) or GD-330 (10 ft) flexible vent kits\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.napoleon.com\/sites\/default\/files\/fireplaces_products\/Ascent%2046%20Installation%20and%20Operation%20Manual%20-%20%0AW415-2370_4ae43cbe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAscent 46 installation and operation manual (W415-2370 rev. D, 12.09.20)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.napoleon.com\/sites\/default\/files\/fireplaces_products\/Ascent%2046%20Specification%20Sheet%20-%20%0AW415-1892_ac5f10b3.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.napoleon.com\/sites\/default\/files\/fireplaces_products\/ADBRN1-ASCENT%20-%20Ascent%20DIGITAL_8e92b7b3.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAscent series brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/images.salsify.com\/image\/upload\/s--ivGVl9Ac--\/u78xby1949nr9a4prtko.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAscent fuel conversion kit instructions, electronic ignition (W415-1547)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/images.salsify.com\/image\/upload\/s--O9jatvOK--\/ea96uvwzdlyky96rdqsm.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAUB \/ GX600KT blower installation (W415-1680)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/images.salsify.com\/image\/upload\/s--LvmaaS60--\/pxmd1rjenettzpkmtxvx.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAscent series nailing bracket instructions (W415-1621)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eProduct video\u003c\/h3\u003e\u003cdiv class=\"uf-desc-video\" style=\"position:relative;width:100%;max-width:960px;aspect-ratio:16\/9;margin:0 0 16px\"\u003e\u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/xs_biP4Zxeg?rel=0\" title=\"Napoleon Ascent Series Gas Fireplaces\" loading=\"lazy\" style=\"position:absolute;inset:0;width:100%;height:100%;border:0;border-radius:4px\" allow=\"accelerometer; encrypted-media; gyroscope; picture-in-picture; fullscreen\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e Improper installation, adjustment, service or maintenance can cause fire, explosion or carbon-monoxide exposure. This appliance must be installed and serviced by a qualified professional following Napoleon's installation manual. The glass gets very hot, so keep children, pets and furniture away and always use the safety barrier.\u003c\/p\u003e\u003ch4\u003eGeneral information (manual chapter 1.0)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eInstall and service by a qualified installer, service agency or gas supplier; indoor use only.\u003c\/li\u003e\n\u003cli\u003eCertified to CSA 2.22 \/ ANSI Z21.50; approved for bathrooms, bedrooms and bed-sitting rooms, and for mobile and permanently located manufactured homes where local codes allow.\u003c\/li\u003e\n\u003cli\u003eMassachusetts: licensed plumber or gas fitter, T-handle gas shut-off, flex connector no longer than 36\" and a CO detector are required; bedroom or bathroom use only as a direct-vent sealed-combustion appliance.\u003c\/li\u003e\n\u003cli\u003eRated 0-4,500 ft; above 4,500 ft reduce input 4% per 1,000 ft.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eVenting (manual chapters 2.0 and 4.0)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e4\" \/ 7\" vent, top or rear; up to 20 ft horizontal and 40 ft vertical; at most two horizontal or three vertical flex connections.\u003c\/li\u003e\n\u003cli\u003eSupport the vent every 3 ft; seal joints with red high-temperature RTV (W573-0002) and the collar with black Mill Pac (W573-0007).\u003c\/li\u003e\n\u003cli\u003eTerminal clearances include 12\" above grade, 7 ft above public walkways, 16\" above the roof and 3 ft from gas meters and regulators.\u003c\/li\u003e\n\u003cli\u003ePeriscope GD-201: bottom air slot at least 12\" above grade, maximum 10 ft of vent on a fireplace.\u003c\/li\u003e\n\u003cli\u003eExisting masonry chimney: 3\" co-linear aluminium flex the full chimney height, 10 to 40 ft, only in a non-combustible chimney.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eRough framing and clearances (manual chapter 3.0)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMinimum framing 46 1\/2\" W x 18 9\/16\" D and enclosure height 50 1\/2\" (top vent) \/ 41 5\/8\" (rear vent).\u003c\/li\u003e\n\u003cli\u003eKeep the vent pipe clearances above; do not notch framing around the standoffs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eElectrical and gas (manual chapters 5.0-6.0)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eElectronic models: 115 V supply with 4 AA battery back-up; never wire 110 V to the valve or wall switch.\u003c\/li\u003e\n\u003cli\u003eOptional wall switch or millivolt thermostat: maximum lead 100 ft (14 AWG), 60 ft (16 AWG) or 40 ft (18 AWG).\u003c\/li\u003e\n\u003cli\u003e1\/2\" gas supply with flex connector (3\/8\" without); leak-test with soap solution, never a flame; disconnect the appliance for tests above 1\/2 psig.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFinishing (manual chapters 9.0-10.0)\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUse non-combustible facing where specified and follow the mantel clearance chart.\u003c\/li\u003e\n\u003cli\u003eInstall the safety barrier; it is required. Never run the fireplace with the glass removed, cracked or broken.\u003c\/li\u003e\n\u003cli\u003ePlace the logs and embers exactly as shown in the log placement section.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eOperation and maintenance\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDo not burn wood or other materials, and do not modify the appliance; use only certified parts and accessories.\u003c\/li\u003e\n\u003cli\u003eHave the fireplace and vent inspected by a qualified technician every year; clean the glass only when cool.\u003c\/li\u003e\n\u003cli\u003eDo not use the fireplace if any part has been under water; keep children and pets away from the hot glass and fit a CO detector nearby.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eUS: local codes, or where none apply the latest \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\" target=\"_blank\" rel=\"noopener\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eCanada: CSA B149.1 Natural Gas and Propane Installation Code and CSA C22.1 Canadian Electrical Code (\u003ca href=\"https:\/\/www.csagroup.org\" target=\"_blank\" rel=\"noopener\"\u003eCSA Group\u003c\/a\u003e).\u003c\/li\u003e\n\u003cli\u003eElectrical (US): \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\" target=\"_blank\" rel=\"noopener\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eManufactured \/ mobile homes: \u003ca href=\"https:\/\/www.ecfr.gov\/current\/title-24\/subtitle-B\/chapter-XX\/part-3280\" target=\"_blank\" rel=\"noopener\"\u003eHUD 24 CFR Part 3280\u003c\/a\u003e (or ANSI\/NFPA 501A where 3280 does not apply); Canada CAN\/CSA Z240 MH.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNapoleon President's Limited Lifetime Warranty (Ascent 46 installation and operation manual W415-2370, section 18.0).\u003c\/li\u003e\n\u003cli\u003eLifetime, for as long as the original purchaser owns it: combustion chamber, heat exchanger, steel burner, PHAZER logs and embers, rocks, ceramic glass (thermal breakage only), gold-plated parts (tarnish), porcelain enamel components and aluminum extrusion trim.\u003c\/li\u003e\n\u003cli\u003eElectrical (110 V and millivolt) components and wear parts (blowers, gas valves, thermal switches, switches, wiring, remote controls, igniters, gaskets, pilot assemblies): replacement parts free in the first year.\u003c\/li\u003e\n\u003cli\u003eLabour for warranty repairs: free in the first year, with prior approval through an authorized dealer, at Napoleon's set rate schedule (gas log sets excluded).\u003c\/li\u003e\n\u003cli\u003eYears 1 to 10: defective lifetime-covered parts repaired or replaced free at Napoleon's discretion; from 10 years on, replacement parts at 50% of the current retail price.\u003c\/li\u003e\n\u003cli\u003eWho is covered: the original purchaser, bought through an authorized Napoleon dealer and installed by a licensed, authorized technician per the instructions and local codes; non-transferable; starts at original installation; proof of purchase with model and serial number needed.\u003c\/li\u003e\n\u003cli\u003eKey exclusions: misuse, neglect, lack of maintenance, accidents, alteration, other makers' parts, heat or chemical damage to finishes, chipped porcelain, mechanical breakage of PHAZER logs, overfiring, downdrafts, venting or negative-pressure problems, water, weather or condensation damage; shipping, travel and diagnostic charges.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e","brand":"Napoleon","offers":[{"title":"Electronic","offer_id":50593569013922,"sku":"B46NTRE","price":3149.0,"currency_code":"USD","in_stock":true},{"title":"Millivolt","offer_id":50593569046690,"sku":"B46NTR","price":3149.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/napoleon-8ac5ad5b25f70624a1c4.jpg?v=1791689415","url":"https:\/\/unitedfireplaces.com\/products\/napoleon-b46","provider":"United Fireplaces","version":"1.0","type":"link"}