{"product_id":"majestic-quartz-platinum-32-gas-fireplace-tbsc32x","title":"Majestic Quartz Platinum 32\" Gas Fireplace TBSC32X","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Majestic Quartz Platinum 32\" (TBSC32X) is the premium version of the redesigned Quartz direct vent gas fireplace. It comes with the IFT-RC400 touchscreen remote, a GFK-160A variable-speed blower, LED illuminated embers and clear ceramic glass, so the remote and fan are already in the box.\u003c\/p\u003e\u003cp\u003eThe fireplace is sold as a firebox. Majestic requires a front and a log set, plus interior panels to complete it, all sold separately: choose the Contemporary Rectangular Door (Black or New Bronze) or the Decorative Black Mesh front, and the Traditional or Birch log set. The Platinum also needs one set of interior panels: reflective black glass or Tavern Brown brick.\u003c\/p\u003e\u003cp\u003eInput is 14,500-27,500 BTU\/h on natural gas and 13,000-25,000 BTU\/h on propane.\u003c\/p\u003e\u003cp\u003eIt vents through the top with SLP or SLP-Flex pipe or through the rear with DVP pipe, and it is approved for the PVLP-SLP, PVI-SLP-B and PVV-SLP power vents with the power vent wire harness and IFT-RC400 remote.\u003c\/p\u003e\u003cp\u003eThe Quartz series comes in 32, 36 and 42 in. sizes, each in a standard and a Platinum version.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect vent\u003c\/strong\u003e: Sealed combustion uses outside air and vents outdoors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelliFire Touch ignition\u003c\/strong\u003e: With battery backup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTouchscreen remote included\u003c\/strong\u003e: IFT-RC400 with dock (includes the AUX module).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-speed fan included\u003c\/strong\u003e: GFK-160A blower.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED illuminated embers and ceramic glass\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo front styles\u003c\/strong\u003e: Contemporary Rectangular Door (Black or New Bronze) or Decorative Black Mesh, sold separately and required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo log sets\u003c\/strong\u003e: Traditional or Birch, sold separately and required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterior panels (required)\u003c\/strong\u003e: Reflective black glass or Tavern Brown brick.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop or rear venting\u003c\/strong\u003e: SLP or SLP-Flex top, DVP rear; power vent approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrim kits\u003c\/strong\u003e: 3-sided or 4-sided black trim kits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat management\u003c\/strong\u003e: Heat-Zone and Heat-Out kits available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Thermostat\u003c\/strong\u003e: Majestic lists Dynamic Thermostat, which lowers the flame as the room warms, for the Quartz series.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eTBSC32XN (natural gas) \/ TBSC32XL (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eDirect vent gas fireplace, top or rear vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas\u003c\/th\u003e\n\u003ctd\u003e14,500-27,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane\u003c\/th\u003e\n\u003ctd\u003e13,000-25,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eIntelliFire Touch, battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eCeramic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEmbers\u003c\/th\u003e\n\u003ctd\u003eLED illuminated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e27-3\/16 x 18-1\/16 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVent collars\u003c\/th\u003e\n\u003ctd\u003e4 x 6-5\/8 in. top, 5 x 8 in. rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eSLP or SLP-Flex (top), DVP (rear); PVLP-SLP, PVI-SLP-B, PVV-SLP power vents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003eUnswitched 110-120 VAC circuit, minimum 14-2 AWG with ground; 6 V IntelliFire valve powered by the 6 V transformer or 4 AA batteries (not included); junction box included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas pressure, natural gas\u003c\/th\u003e\n\u003ctd\u003eInlet 5.0 in. w.c. minimum, 10.0 in. w.c. maximum; manifold 3.5 in. w.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas pressure, propane\u003c\/th\u003e\n\u003ctd\u003eInlet 11.0 in. w.c. minimum, 13.0 in. w.c. maximum; manifold 10.0 in. w.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eListed by Underwriters Laboratories (UL) as a direct vent heater to CSA\/ANSI Z21.88-2019 \/ CSA 2.33-2019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverall width\u003c\/th\u003e\n\u003ctd\u003e36 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming width\u003c\/th\u003e\n\u003ctd\u003e37 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming height\u003c\/th\u003e\n\u003ctd\u003e34-3\/4 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming depth\u003c\/th\u003e\n\u003ctd\u003e16-1\/4 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eViewing area 27-3\/16 x 18-1\/16 in.; framing width 37 in.; framing height 34-3\/4 in.; framing depth 16-1\/4 in. (Majestic Quartz Series specifications; installation manual 2641-980 Rev N, same-size Quartz 32; the Platinum 36 manual 2643-980 shows the same figures as the standard 36, Fig. 3.4).\u003c\/li\u003e\n\u003cli\u003eOverall width 36 in. (installation manual 2641-980 Rev N, same-size Quartz 32; the Platinum 36 manual 2643-980 shows the same figures as the standard 36, Fig. 3.1).\u003c\/li\u003e\n\u003cli\u003eExterior chase: at least 42-3\/4 in. from the bottom of the fireplace to a combustible surface above (installation manual 2641-980 Rev N, same-size Quartz 32; the Platinum 36 manual 2643-980 shows the same figures as the standard 36).\u003c\/li\u003e\n\u003cli\u003eCombustible flooring may not be more than 1 in. above the base of the fireplace. Set the fireplace on a hard metal or wood surface that runs its full width and depth.\u003c\/li\u003e\n\u003cli\u003eVent pipe clearance to combustibles: 3 in. above horizontal runs, 1 in. at the bottom and sides.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eQuartz Platinum 32 firebox with IntelliFire Touch ignition system\u003c\/li\u003e\n\u003cli\u003eIFT-RC400 touchscreen remote\u003c\/li\u003e\n\u003cli\u003eGFK-160A variable-speed blower\u003c\/li\u003e\n\u003cli\u003eCeramic glass\u003c\/li\u003e\n\u003cli\u003eLED illuminated embers\u003c\/li\u003e\n\u003cli\u003eExternal air shutter adjustment\u003c\/li\u003e\n\u003cli\u003eBattery backup\u003c\/li\u003e\n\u003cli\u003eGas flex connector with shut-off valve\u003c\/li\u003e\n\u003cli\u003eJunction box\u003c\/li\u003e\n\u003cli\u003e4 x 6-5\/8 in. top vent collar and 5 x 8 in. rear vent collar\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFront: Contemporary Rectangular Door (Black or New Bronze) or Decorative Black Mesh\u003c\/li\u003e\n\u003cli\u003eLog set: Traditional or Birch\u003c\/li\u003e\n\u003cli\u003eInterior panels: reflective black glass or Tavern Brown brick\u003c\/li\u003e\n\u003cli\u003eQuartz Platinum 32 requires a direct vent (SLP top vent or DVP rear vent) venting system, not included with purchase.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIFT-RC150 wireless wall switch\u003c\/li\u003e\n\u003cli\u003eIFT-WFM Wi-Fi module for the IntelliFire app\u003c\/li\u003e\n\u003cli\u003eBattery backup wall switch kit\u003c\/li\u003e\n\u003cli\u003e3-sided or 4-sided black trim kit\u003c\/li\u003e\n\u003cli\u003eHeat-Zone kit (up to two) or Heat-Out kit\u003c\/li\u003e\n\u003cli\u003eExterior Heat-Zone brick extension kit\u003c\/li\u003e\n\u003cli\u003ePVLP-SLP, PVI-SLP-B or PVV-SLP power vent\u003c\/li\u003e\n\u003cli\u003eMajestic flush mantels and mantel shelves sized for the Quartz 32\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/2643_980_QUARTZPLA36_INSTALL.pdf\"\u003eQuartz Platinum 36 installation manual 2643-980 Rev J (earlier QUARTZPLA36 model; shared Platinum data)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/2641_980_QUARTZ323642IFT_INSTALL.pdf\"\u003eQuartz 32\/36\/42 installation manual 2641-980 Rev N (earlier QUARTZ IFT models; same-size dimensions and framing)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.majesticproducts.com\/fireplaces\/gas\/quartz-series-direct-vent-gas-fireplace\"\u003eMajestic Quartz Series product page and specifications (majesticproducts.com)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/brochures\/FSF-1016U_Mantels.pdf\"\u003eMantels, shelves and surrounds brochure FSF-1016U\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/InstallManuals\/Addendums\/2196_902_PVI-SLP-B_Power_Vent_Inline.pdf\"\u003eInline power vent PVI-SLP-B instructions 2196-902 Rev Y (lists the Quartz TBSC models)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/Addendums\/4071_900_PVV-SLP_Installation_Instructions.pdf\"\u003eVertical power vent PVV-SLP instructions 4071-900 Rev O (lists the Quartz TBSC models)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Have it installed and serviced by a qualified installer, service agency or gas supplier, following the Majestic installation manual and local codes. If you ever smell gas, do not light any appliance, do not use electrical switches or phones in the building, leave the building and call your gas supplier from a neighbor's phone.\u003c\/p\u003e\u003ch4\u003eSite and installation requirements\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOrder the model that matches your fuel: N = natural gas, L = propane.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFront, logs and panels\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMajestic lists the front and the log set and the interior panels as required to complete the fireplace; all are sold separately.\u003c\/li\u003e\n\u003cli\u003eNever operate the fireplace without its decorative front installed; the front prevents contact with the hot glass (installation manual 2643-980).\u003c\/li\u003e\n\u003cli\u003eHigh altitude: in the U.S., reduce input 4% for each 1,000 ft above 2,000 ft; in Canada the ratings apply without reduction up to 4,500 ft (installation manual 2643-980, Sec. 1.D).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eTermination location \u0026amp; vent information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eTop venting uses Hearth \u0026amp; Home SLP or SLP-Flex pipe; rear venting uses DVP pipe (Majestic price book, venting notes).\u003c\/li\u003e\n\u003cli\u003eApproved power vents: PVLP-SLP, PVI-SLP-B and PVV-SLP, each with the power vent wire harness and the IFT-RC400 remote (ordered separately; the IFT-RC400 is included with the Platinum).\u003c\/li\u003e\n\u003cli\u003eWith the PVV-SLP vertical power vent, the Quartz needs at least 5 ft of straight pipe between the fireplace and the power vent (HHT instructions 4071-900 Rev O, Table 2.1).\u003c\/li\u003e\n\u003cli\u003eTop vent: up to 60 ft straight vertical; the total vent run (vertical plus horizontal) may not exceed 40 ft; an exhaust restrictor may be needed when the total vertical is 15-60 ft (installation manual 2643-980, Sec. 4).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eGas installation: follow local codes or, where none apply, the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e (U.S.) or the \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1 Natural Gas and Propane Installation Code\u003c\/a\u003e (Canada)\u003c\/li\u003e\n\u003cli\u003eElectrical: wire and ground to local codes or, where none apply, the \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e (U.S.) or the \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (Canada)\u003c\/li\u003e\n\u003cli\u003eMassachusetts: installation by a licensed plumber or gas fitter under the \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003eMassachusetts fuel gas code (248 CMR)\u003c\/a\u003e; side-wall vents under 7 ft need a hard-wired CO detector with battery backup meeting \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034\u003c\/li\u003e\n\u003cli\u003eNon-combustible materials are defined by ASTM E136 (published by ASTM International)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Hearth \u0026amp; Home Technologies (HHT) limited warranty; Majestic is an HHT brand.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product and the fuels used to operate this product (liquid propane or natural gas), and the products of combustion of such fuels, can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e","brand":"Majestic","offers":[{"title":"Propane \/ Electronic Ignition - Top\/Rear Direct Vent Fireplace","offer_id":50959440019618,"sku":"TBSC32XL","price":2939.0,"currency_code":"USD","in_stock":true},{"title":"Natural Gas \/ Electronic Ignition - Top\/Rear Direct Vent Fireplace","offer_id":50959440052386,"sku":"TBSC32XN","price":2939.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/unitedfireplaces.com\/products\/majestic-quartz-platinum-32-gas-fireplace-tbsc32x","provider":"United Fireplaces","version":"1.0","type":"link"}