{"product_id":"majestic-quartz-42-direct-vent-gas-fireplace-tbsc42","title":"Majestic Quartz 42\" Direct Vent Gas Fireplace TBSC42","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eThe Majestic Quartz 42\" (TBSC42) is the redesigned Quartz direct vent gas fireplace: a slim, budget-friendly traditional fireplace with glowing embers behind tempered glass and IntelliFire Touch ignition with battery backup.\u003c\/p\u003e\u003cp\u003eThe fireplace is sold as a firebox. Majestic requires a front and a log set to complete it, all sold separately: choose the Contemporary Rectangular Door (Black or New Bronze) or the Decorative Black Mesh front, and the Traditional or Birch log set. Reflective black glass or Tavern Brown brick interior panels are optional.\u003c\/p\u003e\u003cp\u003eInput is 15,500-30,000 BTU\/h on natural gas and 14,500-30,000 BTU\/h on propane.\u003c\/p\u003e\u003cp\u003eIt vents through the top with SLP or SLP-Flex pipe or through the rear with DVP pipe, and it is approved for the PVLP-SLP, PVI-SLP-B and PVV-SLP power vents with the power vent wire harness and IFT-RC400 remote.\u003c\/p\u003e\u003cp\u003eThe Quartz series comes in 32, 36 and 42 in. sizes; the Quartz Platinum version adds the touchscreen remote, variable-speed fan, LED embers and ceramic glass as standard.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect vent\u003c\/strong\u003e: Sealed combustion uses outside air and vents outdoors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelliFire Touch ignition\u003c\/strong\u003e: With battery backup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional controls\u003c\/strong\u003e: IFT-RC400 touchscreen remote, IFT-RC150 wireless wall switch, IFT-WFM Wi-Fi module, BATTERY-WSK wall switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional fan\u003c\/strong\u003e: 160 CFM fan kit, fan only or with rheostat and temperature sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlowing embers and tempered glass\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo front styles\u003c\/strong\u003e: Contemporary Rectangular Door (Black or New Bronze) or Decorative Black Mesh, sold separately and required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo log sets\u003c\/strong\u003e: Traditional or Birch, sold separately and required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterior options\u003c\/strong\u003e: Reflective black glass or Tavern Brown brick panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop or rear venting\u003c\/strong\u003e: SLP or SLP-Flex top, DVP rear; power vent approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat management\u003c\/strong\u003e: Heat-Zone and Heat-Out kits available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Thermostat\u003c\/strong\u003e: Majestic lists Dynamic Thermostat, which lowers the flame as the room warms, for the Quartz series.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eTBSC42N (natural gas) \/ TBSC42L (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eDirect vent gas fireplace, top or rear vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, natural gas\u003c\/th\u003e\n\u003ctd\u003e15,500-30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput, propane\u003c\/th\u003e\n\u003ctd\u003e14,500-30,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eIntelliFire Touch, battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003eTempered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEmbers\u003c\/th\u003e\n\u003ctd\u003eGlowing embers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing area\u003c\/th\u003e\n\u003ctd\u003e39-1\/16 x 23-9\/16 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVent collars\u003c\/th\u003e\n\u003ctd\u003e4 x 6-5\/8 in. top, 5 x 8 in. rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVenting\u003c\/th\u003e\n\u003ctd\u003eSLP or SLP-Flex (top), DVP (rear); PVLP-SLP, PVI-SLP-B, PVV-SLP power vents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003eUnswitched 110-120 VAC circuit, minimum 14-2 AWG with ground; 6 V IntelliFire valve powered by the 6 V transformer or 4 AA batteries (not included); junction box included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas pressure, natural gas\u003c\/th\u003e\n\u003ctd\u003eInlet 5.0 in. w.c. minimum, 10.0 in. w.c. maximum; manifold 3.5 in. w.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas pressure, propane\u003c\/th\u003e\n\u003ctd\u003eInlet 11.0 in. w.c. minimum, 13.0 in. w.c. maximum; manifold 10.0 in. w.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eListed by Underwriters Laboratories (UL) as a direct vent heater to CSA\/ANSI Z21.88-2019 \/ CSA 2.33-2019; certified for bedroom or bedsitting-room installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverall width\u003c\/th\u003e\n\u003ctd\u003e48 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming width\u003c\/th\u003e\n\u003ctd\u003e49 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming height\u003c\/th\u003e\n\u003ctd\u003e40-1\/4 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFraming depth\u003c\/th\u003e\n\u003ctd\u003e16-1\/4 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eViewing area 39-1\/16 x 23-9\/16 in.; framing width 49 in.; framing height 40-1\/4 in.; framing depth 16-1\/4 in. (Majestic Quartz Series specifications; installation manual 2641-980, Fig. 3.4).\u003c\/li\u003e\n\u003cli\u003eOverall width 48 in. (installation manual 2641-980, Fig. 3.1).\u003c\/li\u003e\n\u003cli\u003eExterior chase: at least 48-1\/4 in. from the bottom of the fireplace to a combustible surface above (installation manual 2641-980).\u003c\/li\u003e\n\u003cli\u003eCombustible flooring may not be more than 1 in. above the base of the fireplace. Set the fireplace on a hard metal or wood surface that runs its full width and depth.\u003c\/li\u003e\n\u003cli\u003eVent pipe clearance to combustibles: 3 in. above horizontal runs, 1 in. at the bottom and sides.\u003c\/li\u003e\n\u003cli\u003eCombustible materials above the fireplace: at least 15 in. above the top of the unit, or at least 12 in. with the elbow heat shield installed (installation manual 2641-980, Sec. 6.A).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eQuartz 42 firebox with IntelliFire Touch ignition system\u003c\/li\u003e\n\u003cli\u003eTempered glass\u003c\/li\u003e\n\u003cli\u003eGlowing embers\u003c\/li\u003e\n\u003cli\u003eExternal air shutter adjustment\u003c\/li\u003e\n\u003cli\u003e12 ft control wire\u003c\/li\u003e\n\u003cli\u003eBattery backup\u003c\/li\u003e\n\u003cli\u003eGas flex connector with shut-off valve\u003c\/li\u003e\n\u003cli\u003eJunction box\u003c\/li\u003e\n\u003cli\u003e4 x 6-5\/8 in. top vent collar and 5 x 8 in. rear vent collar\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFront: Contemporary Rectangular Door (Black or New Bronze) or Decorative Black Mesh\u003c\/li\u003e\n\u003cli\u003eLog set: Traditional or Birch\u003c\/li\u003e\n\u003cli\u003eQuartz 42 requires a direct vent (SLP top vent or DVP rear vent) venting system, not included with purchase.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eReflective black glass or Tavern Brown brick interior panels\u003c\/li\u003e\n\u003cli\u003e160 CFM fan kit (fan only, or with rheostat and temperature sensor)\u003c\/li\u003e\n\u003cli\u003eIFT-RC400 touchscreen remote\u003c\/li\u003e\n\u003cli\u003eIFT-RC150 wireless wall switch\u003c\/li\u003e\n\u003cli\u003eIFT-WFM Wi-Fi module for the IntelliFire app\u003c\/li\u003e\n\u003cli\u003eBattery backup wall switch kit\u003c\/li\u003e\n\u003cli\u003eIFT-ACM AUX module (only needed for a fan, lights or power vent run from the Wi-Fi module without an IFT-RC400)\u003c\/li\u003e\n\u003cli\u003eHeat-Zone kit (up to two) or Heat-Out kit\u003c\/li\u003e\n\u003cli\u003ePVLP-SLP, PVI-SLP-B or PVV-SLP power vent\u003c\/li\u003e\n\u003cli\u003eMajestic flush mantels and mantel shelves sized for the Quartz 42\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/2641_980_QUARTZ323642IFT_INSTALL.pdf\"\u003eQuartz 32\/36\/42 installation manual 2641-980 Rev N (written for the earlier QUARTZ IFT models; clearances, electrical, gas and venting data)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.majesticproducts.com\/fireplaces\/gas\/quartz-series-direct-vent-gas-fireplace\"\u003eMajestic Quartz Series product page and specifications (majesticproducts.com)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/brochures\/FSF-1016U_Mantels.pdf\"\u003eMantels, shelves and surrounds brochure FSF-1016U\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/InstallManuals\/Addendums\/2196_902_PVI-SLP-B_Power_Vent_Inline.pdf\"\u003eInline power vent PVI-SLP-B instructions 2196-902 Rev Y (lists the Quartz TBSC models)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/Addendums\/4071_900_PVV-SLP_Installation_Instructions.pdf\"\u003eVertical power vent PVV-SLP instructions 4071-900 Rev O (lists the Quartz TBSC models)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e⚠ Important:\u003c\/strong\u003e this is a gas appliance. Improper installation, adjustment, service or maintenance can cause a fire, an explosion or carbon-monoxide exposure. Have it installed and serviced by a qualified installer, service agency or gas supplier, following the Majestic installation manual and local codes. If you ever smell gas, do not light any appliance, do not use electrical switches or phones in the building, leave the building and call your gas supplier from a neighbor's phone.\u003c\/p\u003e\u003ch4\u003eSite and installation requirements\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eOrder the model that matches your fuel: N = natural gas, L = propane.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFront, logs and panels\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eMajestic lists the front and the log set as required to complete the fireplace; all are sold separately.\u003c\/li\u003e\n\u003cli\u003eNever operate the fireplace without its decorative front installed; the front prevents contact with the hot glass (installation manual 2641-980, p.65).\u003c\/li\u003e\n\u003cli\u003eHigh altitude: in the U.S., reduce input 4% for each 1,000 ft above 2,000 ft; in Canada the ratings apply without reduction up to 4,500 ft (installation manual 2641-980, Sec. 1.D).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eTermination location \u0026amp; vent information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eTop venting uses Hearth \u0026amp; Home SLP or SLP-Flex pipe; rear venting uses DVP pipe (Majestic price book, venting notes).\u003c\/li\u003e\n\u003cli\u003eApproved power vents: PVLP-SLP, PVI-SLP-B and PVV-SLP, each with the power vent wire harness and the IFT-RC400 remote (ordered separately).\u003c\/li\u003e\n\u003cli\u003eWith the PVV-SLP vertical power vent, the Quartz needs at least 5 ft of straight pipe between the fireplace and the power vent (HHT instructions 4071-900 Rev O, Table 2.1).\u003c\/li\u003e\n\u003cli\u003eTop vent: up to 60 ft straight vertical; the total vent run (vertical plus horizontal) may not exceed 40 ft; an exhaust restrictor may be needed when the total vertical is 15-60 ft (installation manual 2641-980, Sec. 4).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eBuilding code information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eGas installation: follow local codes or, where none apply, the current \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-54-standard-development\/54\"\u003eNational Fuel Gas Code, ANSI Z223.1\/NFPA 54\u003c\/a\u003e (U.S.) or the \u003ca href=\"https:\/\/www.csagroup.org\/store\/natural-gas-and-propane-installation-code\/\"\u003eCSA B149.1 Natural Gas and Propane Installation Code\u003c\/a\u003e (Canada)\u003c\/li\u003e\n\u003cli\u003eElectrical: wire and ground to local codes or, where none apply, the \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\"\u003eNational Electrical Code, ANSI\/NFPA 70\u003c\/a\u003e (U.S.) or the \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA_C22.1%3A24_PACKAGE\/\"\u003eCSA C22.1 Canadian Electrical Code\u003c\/a\u003e (Canada)\u003c\/li\u003e\n\u003cli\u003eMassachusetts: installation by a licensed plumber or gas fitter under the \u003ca href=\"https:\/\/www.mass.gov\/regulations\/248-CMR-500-mass-fuel-gas-code\"\u003eMassachusetts fuel gas code (248 CMR)\u003c\/a\u003e; side-wall vents under 7 ft need a hard-wired CO detector with battery backup meeting \u003ca href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-720-standard-development\/720\"\u003eNFPA 720\u003c\/a\u003e and ANSI\/UL 2034\u003c\/li\u003e\n\u003cli\u003eNon-combustible materials are defined by ASTM E136 (published by ASTM International)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Hearth \u0026amp; Home Technologies (HHT) limited warranty; Majestic is an HHT brand.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product and the fuels used to operate this product (liquid propane or natural gas), and the products of combustion of such fuels, can expose you to chemicals including benzene, which is known to the State of California to cause cancer and reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFlames and flame colors on the website may appear differently in real life.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003ePlease follow the manufacturer's installation instructions exactly. Improper installation can cause fire, property damage or injury. United Fireplaces recommends that every appliance be installed by a qualified professional installer.\u003c\/p\u003e","brand":"Majestic","offers":[{"title":"Natural Gas \/ Electronic Ignition - Top\/Rear Direct Vent Fireplace","offer_id":50593311326370,"sku":"TBSC42N","price":2329.0,"currency_code":"USD","in_stock":true},{"title":"Propane \/ Electronic Ignition - Top\/Rear Direct Vent Fireplace","offer_id":50593311359138,"sku":"TBSC42L","price":2329.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Screenshot_2026-08-19_122807__86321.1787163608.1280.1280.jpg?v=1791817422","url":"https:\/\/unitedfireplaces.com\/products\/majestic-quartz-42-direct-vent-gas-fireplace-tbsc42","provider":"United Fireplaces","version":"1.0","type":"link"}