{"product_id":"majestic-echelon-ii-72-fireplace-with-intellifire-plus-ignition-echel72in-c","title":"Majestic Products 72\" Echelon II Natural Gas \/ Electronic Ignition Linear Direct Vent Fireplace  ECHEL72IN-C","description":"\u003ch3\u003eProduct overview\u003c\/h3\u003e\u003cp\u003eMajestic Products 72\" Echelon II Natural Gas Linear Direct Vent Fireplace  ECHEL72IN-C is a single-sided linear direct-vent gas appliance with LED-lit media and IntelliFire Touch controls. The exact model’s appliance classification and fuel conversion requirements are listed below.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIlluminated glass fire bed with model-approved interior choices.\u003c\/li\u003e\n\u003cli\u003eSealed direct-vent combustion system.\u003c\/li\u003e\n\u003cli\u003eTouchscreen control and emergency battery operation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ca href=\"https:\/\/www.youtube.com\/embed\/2ZQmVEE47Xk\"\u003eProduct video\u003c\/a\u003e\u003ch3\u003eIncluded components\u003c\/h3\u003e\u003cp\u003eThe Echelon includes its approved glass-media kit, LED ember-bed lighting, ceramic glass assembly and IntelliFire Touch controls with RC400 remote.\u003c\/p\u003e\u003ch3\u003eRequired components\u003c\/h3\u003e\u003cp\u003eA compatible decorative barrier front must be ordered separately and installed before operation. Approved direct venting, correct fuel supply, electrical supply and the specified non-combustible facing are required installation provisions. Do not operate with a barrier or fixed glass assembly removed.\u003c\/p\u003e\u003ch3\u003eOptional accessories\u003c\/h3\u003e\u003cp\u003eDriftwood logs, stones, reflective glass panels and alternative approved glass-media colors are optional. The included media already provides the standard fire bed; an optional replacement-media package is not a second mandatory base purchase. The manual limits this model to 7 bags of installed glass media. Follow the selected kit’s own quantity and placement instructions when combining logs or stones. Use only HHT-approved media, keep the pilot-lighting area clear and never exceed the specified layer or quantity. If logs and media are chosen together, the manual directs installation of logs first.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eExact model\u003c\/th\u003e\n\u003ctd\u003eECHEL72IN-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing configuration\u003c\/th\u003e\n\u003ctd\u003eSingle-sided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFactory fuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas; propane requires a certified model-specific conversion kit and qualified conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNatural-gas input\u003c\/th\u003e\n\u003ctd\u003e30,000 to 58,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApproved propane-converted input\u003c\/th\u003e\n\u003ctd\u003e25,000 to 45,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eIntelliFire Touch intermittent pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded remote\u003c\/th\u003e\n\u003ctd\u003eFactory-paired RC400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass\u003c\/th\u003e\n\u003ctd\u003e5 mm ceramic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard rough opening\u003c\/th\u003e\n\u003ctd\u003e84-1\/4 inches W x 48 inches H x 18-1\/4 inches D; adjust for sheathing and selected heat-management system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum installed glass media\u003c\/th\u003e\n\u003ctd\u003e7 bags; approved media kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired venting\u003c\/th\u003e\n\u003ctd\u003eHearth \u0026amp; Home Technologies DVP direct vent; separate vent for this appliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum vertical rise before an elbow\u003c\/th\u003e\n\u003ctd\u003e30 inches; full route must meet the model-specific vent diagram\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical supply\u003c\/th\u003e\n\u003ctd\u003eUnswitched 110-120 VAC, minimum 14-2 AWG with ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAppliance classification\u003c\/th\u003e\n\u003ctd\u003eDirect vent heater for supplemental heat; not a primary heat source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAppliance Width\u003c\/th\u003e\n\u003ctd\u003e82\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAppliance Height\u003c\/th\u003e\n\u003ctd\u003e47-3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAppliance Depth\u003c\/th\u003e\n\u003ctd\u003e17-1\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAppliance Rear Width\u003c\/th\u003e\n\u003ctd\u003e82\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eViewing Area\u003c\/th\u003e\n\u003ctd\u003e71-1\/2 x 12-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\u003cp\u003eThis sealed direct-vent system draws combustion air from outdoors and exhausts outdoors. Use the approved DVP system and listed termination components; do not mix manufacturers’ pipes or share the vent with another appliance. The required initial vertical rise is only one part of the vent design: elbow count, horizontal length, total run, termination clearance, firestops and supports must all match the installation diagrams. Optional power venting and heat-management systems have their own compatibility and installation instructions.\u003c\/p\u003e\u003cp\u003eChoose the decorative front and finishing method before framing. Clean Face Trim and Picture Frame styles have different finishing details. Maintain access for service, the required non-combustible finishing areas and all mantel\/ceiling clearances. Optional Passive Heat can change framing and ceiling requirements; do not apply the standard table to a Passive Heat installation without its kit instructions. Have a qualified installer design and install the system under the manufacturer manuals and applicable codes.\u003c\/p\u003e\u003cp\u003eThe factory battery tray accepts four AA batteries for emergency power-outage operation. Batteries are not the normal long-term power source. Lights, fans and other functions requiring household AC power are unavailable on battery backup. Do not connect line voltage directly to the low-voltage ignition module or wall switch. Arrange professional inspection before use and at least annually. Clean cooled glass seasonally with the specified non-abrasive fireplace-glass cleaner, inspect the vent termination and replace any protective barrier removed for service before operation.\u003c\/p\u003e\u003ch3\u003eWarranty summary\u003c\/h3\u003e\u003cp\u003eThe current owner manual contains HHT’s component-specific limited warranty. Coverage depends on the component, authorized purchase, installation location and compliance with installation and maintenance requirements. Read the full schedule and exclusions rather than treating every part as lifetime-covered.\u003c\/p\u003e\u003ch3\u003eExact-model manuals and downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/2608_980_ECHEL36486072-C_INSTALL.pdf\"\u003eEchelon-C installation manual — Rev Z, November 2025\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/installManuals\/2608_981_ECHEL36486072-C_OWNER.pdf\"\u003eEchelon-C owner, maintenance and warranty manual — Rev X, March 2026\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/downloads.hearthnhome.com\/brochures\/MAJ-0011U_EchelonII_broc_2-page.pdf\"\u003eEchelon II manufacturer brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Majestic","offers":[{"title":"Default Title","offer_id":50593310998690,"sku":"ECHEL72IN-C","price":10979.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/5846\/8770\/files\/Majestic-Echelon-II-72-Fireplace-with-IntelliFire-Plus-Ignition-ECHEL72IN-C_2111__34738.1786626179.1280.1280.jpg?v=1791682181","url":"https:\/\/unitedfireplaces.com\/products\/majestic-echelon-ii-72-fireplace-with-intellifire-plus-ignition-echel72in-c","provider":"United Fireplaces","version":"1.0","type":"link"}